Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date21 Nov 2024
Closing Soon9 Dec 2024
Tender Amount₹ 5,09,892
Costs
EMD
₹ 10,198Document Cost
₹ 300Tender Fee
Refer Documents
Summary
Construction Of Subcentre At Harwan, Sopore B W O Electric Work
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_265390_1Tender No
NIT NO.91/2024/25 dt/20/11/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in
surface/Recessed Conduit (Havells/Polycab/ Make) inlc , cost of conduit
225
334
75150
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor roma plus/Schneider Make & shall be approved before execution of work by EIC.
15
586
8790
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable
in surface/Recessed Conduit (Havells/Polycab/Anchor Make) Inlc. Cost of Conduit.
225
275
61875
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor roma plus/Schneider Make & shall be approved before execution of work.
15
680
10200
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of
Havells/Legrand/ Panasonic/Anchor/Schneider Make
20
18
360
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/ Make) & shall be approved before execution of work by EIC. inlc cost of conduit.
-
-
-
2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One
run from Main Panel to Distribution Boards.
35
570
19950
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/ Sub main in One run
from Main Panel to Distribution Boards.
20
439
8780
2x4 sq.mm+ 1x4 sq.mm (P+N+E) for Inverter Sub main in One run from
Main Panel to Distribution Boards.
20
334
6680
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with
connections.(L&T/Siemens/Legrand/Schneider Make)
22
256
5632
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens
/Legrand/Schneider Make)
-
-
-
32 Amp
1
1050
1050
40Amp.
1
1250
1250
63Amp.
2
1850
3700
Supplying and Fixing of MCB 8-Way horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider Make)
1
5900
5900
Supply/Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Bajaj/HG Make. SAmple to be approved by EIC before execution.
18
1650
29700
Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR:- High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.
6
3200
19200
Supply/Installation/Testing and Commissioning of 4 feet long LED Tube light with minimum system lumen efficacy of 100 lm/W with metal body and P.F.0.95 ,THD15% ,CCT 6500K, CRI 80.
Philips/Havell's/Wipro/Bajaj/HG Make for inverter purpose
10
1100
11000
Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells Make.(3-Star)
5
2200
11000
Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/ Make.(Min 1-Star)
3
1900
5700
Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall nounted compartmentalized , Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices
(1) Normal Incoming
100 Amp DP MCB with thermo magnetic adjustable based of Legrand
/ Siemens/ ABB /Schinder /L&T make = 1 no 160 Amp TPN Bus bar Al Strips = 1 Set Volt meter =1 no, Ammeter = 1 no ,phase indicators =1set
Outgoing:
1) 40 Amp = 1 No. for Lighting Circuits
2) 63 Amp = 2 No. for Heating Circuits
3) 32 Amp = 1 No. for inverter of Legrand/Havells/L&T/Schineider/ABB make
1
22000
22000
Supply/Laying/Connecting and Commissioning of 50 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
50
550
27500
Supply installation testing and commissioning of Sine Wave Inverter Capacity 3.5 KVA, Rated Power 2940 W,Supports Four battery, 24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Inverter should run heavy loads like AC, Geyser, Photocopiers, Auto over- Ioad handling capacity lnstallation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes,MCB
for protection from input mains, Bypass switch for supplying output directly from grid in case of Home UPS fault. Noiseless Operations with the help of low harmonic distortion, intiutive display to easily understand status of mains availability, battery status etc. Comprehensive protection against short-circuit, reverse polarity, battery charging and enhances battery life by around 70%. Supports a wide battery range, i,e. Flat plate, Tubular & VRLA (SMF)-preffered make Luminous/Microtek/Exide. The job also includes 2 no. trollies for housing 4 No. batteries and inverter.
1
39500
39500
Supply installation testing and comm. of Inverter battery 180 AH/12 V Exide invatubular/eq. standard make as directed by engineer incharge.
3
22500
67500
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM
Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above.
Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
1
11000
11000
Supply/Laying of 25/32/38mm Dia and 2mm thick PVC Conduit/Lockable Channel of Anchor/Ravindra Blue/Finolex Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint etc.
100
120
12000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%