Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Nov 2024
Closing Soon19 Dec 2024
Tender Amount₹ 56,24,572
Costs
EMD
₹ 1,12,500Document Cost
₹ 1,600Tender Fee
Refer Documents
Summary
Providing Internal Electrification To New Degree College At Eidgah Srinagar (phase- Ist).
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_266170_1Tender No
NIT NO.105/2024/25 dt/27/11/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make.)
111
486
53946
Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit,( excluding the cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
2550
230
586500
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5-10 A modular socket outlet and 2 nos. 5-10 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make.)
121
590
71390
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
30
401
12030
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, "C" curve including connections, painting etc. as required.
10
639
6390
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Polycab/ Fenolex/ Anchor make.), single core cable in surface/ recessed medium class PVC conduit as required.( excluding the cost of conduit)
-
-
-
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
250
170
42500
( c ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire ( for emergency circuit)
380
410
155800
( d )4 X 10 sq. mm + 2 X 6 sq. mm earth wire ( Lighting submain/ three phase points)
380
910
345800
(e) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire ( Heating Submain)
380
1050
399000
Supplying and fixing of following sizes of medium class PVC conduit/ Channel as required.( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster,wall putty, paint complete.
-
-
-
25mm
2750
145
398750
32mm
350
170
59500
40mm
350
210
73500
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) including bends, Tees, cross members and allied accessories with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
-
-
-
225 mm width X 50 mm depth X 1.6 mm thickness
150
950
142500
Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux/Wipro make / sample to be approved before installation..
375
1450
543750
S/F testing and comm. Of surface mounted LED Batten 20 watt-22 watt +- 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. Philips/ Trulux /Wipro make. sample to be approved before installation.
267
450
120150
S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ L&T ./ABB/equivalent make as directed by engineer incharge.
-
-
-
a) 6-32 Amp SP MCB
410
245
100450
b) 40-63amp DP MCB
6
1150
6900
c) 40-63amp TPN MCB
12
2550
30600
Supply installation testing and comm. Of 250mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
10
1850
18500
Supply installation testing and comm. Of 300mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
7
1950
13650
Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates.
150
24
3600
Supply, Installation, Testing and Commissioning of decorative 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA Striker galaxy/Havells Oyster matalic/CromptonAura/equivalent make as directed by engineer incharge.
174
2750
478500
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make as directed by engineer incharge.
174
310
53940
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way (4 + 24), Double door
12
5900
70800
6 way (4 + 18), Double door
6
4974
29844
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block.
45
48
2160
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
2
10500
21000
S/L , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
-
-
-
b)185 sq.mm 3.5 core ( armoured) .
104
1850
192400
c)95 sq.mm 3.5 core ( armoured)
32
1143
36576
d)70 sq.mm 3.5 core ( armoured)
32
915
29280
Main Panel
-
-
-
Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement)
25
2250
56250
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
-
-
-
Normal INCOMING:
-
-
-
MCCB630 A F.P 50 Ka with Adj.T.M.R With Icu=Ics=100% Legrand/ Shinider/Semiens make.( sample to be approved)
1
39500
39500
b) 4 No. of Aluminium Bus Bar of 800 Amp.
1
5500
5500
c)Digital meters and phase indicators -1 set.
1
1200
1200
d) onload Change over switch 250 Amp for generator.Front operated.
1
22500
22500
e) 4 No. of Aluminium Bus Bar of 600 Amp.
1
4500
4500
c)Digital meters and phase indicators -1 set.
1
1260
1260
OUTGOING:
-
-
-
MCCB 200 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100% Legrand/ Shinider/Semiens make.( sample to be approved)
2
19500
39000
MCCB160 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100% Legrand/ Shinider/Semiens make.( sample to be approved)
2
14500
29000
c) 40-63amp TPN MCB 10 KA Legrand/ Shinider/ABB/L&T sample to be approved before installation..
6
2550
15300
c) space for 20 way MCB's
1
850
850
(First floor Panel)Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement)
12
2250
27000
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
-
-
-
Normal INCOMING:
-
-
-
MCCB 200 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100% Legrand/ Shinider/Semiens make.( sample to be approved)
1
19400
19400
b) 4 No. of Aluminium Bus Bar of 300 Amp.
1
3500
3500
c)Digital meters and phase indicators -1 set.
1
1200
1200
MCCB 160 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100% Legrand/ Shinider/Semiens make.( sample to be approved)
1
14500
14500
b) 4 No. of Aluminium Bus Bar of 200 Amp.
1
2948
2948
c)Digital meters and phase indicators -1 set.
1
1200
1200
OUTGOING:
-
-
-
c) 40-63amp TPN MCB 10 KA Legrand/ Shinider/ABB/L&T sample to be approved before installation..
6
2568
15408
c) space for 12 way MCB's
1
850
850
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%