Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Electrical and Electronics
Eprocure
Opening Date20 Jul 2021
Closing Date30 Jul 2021
Tender Amount₹ 55,60,000 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supplying, Installation,Testing and Commissioning of VRV/VRF Air Conditioning of Examination Hall at PSC Building at Reshamgarh Jammu.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
INDOOR UNITS Supply, installtion,testing & commissioning of Round Flow Type cassette units with builtin drain pump with decorative panel(Nominal Capacity)

-

-

-

... More
4 way-Round Flow Cassette Type Unit - 4.0 TR

5

-

-

... More
4 way-Round Flow Cassette Type Unit - 3.0 TR

11

-

-

... More
Hi- Wall unit 2.0TR Minimum

2

-

-

... More
Remote Controller Installation , testing and commissioning of corded remote controller suitable for Indoor units and suitable to work on single phase 230 volt (+)(-) 10% 50 Hz AC supply.

18

-

-

... More
Refrigerant Joints/ Headers Installation , testing and commissioning of imported Y-joints fittings and header to all indoor units at all floors including alignments of joints complete as required.

19

-

-

... More
Hi - Wall Split Units Supply,Installation, testing & Commissioning of Split air conditioning unit with heat pump of2.0ton capacity in copper condensor in 3STAR rating

4

-

-

... More
Refrigerant Piping Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported /fixed with suitable size of clamps /M.S hanger and all exterinal /exposed to sun piping shall run in M.S.painted cable tray with cover at site.

-

-

-

... More
41.2 mm O.D. (insulation : 19mm)

110

-

-

... More
38.1mm O.D. (insulation : 19mm)

110

-

-

... More
34.9 mm O.D. (insulation : 19mm)

100

-

-

... More
31.7 mm O.D. (insulation : 19mm)

125

-

-

... More
28.6 mm O.D. (insulation : 19 mm)

85

-

-

... More
25.4 mm O.D. (insulation : 19 mm)

170

-

-

... More
22.2 mm O.D. (insulation : 13 mm)

130

-

-

... More
19.1 mm O.D. (insulation : 13 mm)

125

-

-

... More
15.9 mm O.D. (insulation : 13 mm)

130

-

-

... More
12.7 mm O.D. (insulation :13 mm)

130

-

-

... More
9.53mm O.D. (insulation : 13 mm)

270

-

-

... More
6.4 mm O.D. (insulation : 13 mm)

100

-

-

... More
CABLE TRAY Supplying and installing following size G.I cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

120

-

-

... More
DRAIN PIPE Providing and fixing rigid CPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.

-

-

-

... More
32 mm dia

170

-

-

... More
25 mm dia

50

-

-

... More
Control & Transmission Wiring Providing & fixing control wiring of 2 core x 1.5 sqmm copper in PVC conduit pipe of 25mm dia including providing & fixing support @1.5mt distance C/C where it is not recessed between indoor units and their wired remote.

792.5

-

-

... More
Providing & fixing control wiring of 2 core x 1.0 sqmm copper in PVC conduit pipe of 25mm dia including providing & fixing support @1.5mt distance C/C where it is not recessed between indoor units and their wired remote.

500

-

-

... More
MAIN ELECTRICAL PANNEL Fabrication, supplying, installation testing and commissioning of following pannel CPRI approved made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly p0wder coated with provision for fixing of 1 no incomer MCCB, outgoing MCB's, , required number of sets of Aluminium Bus Bar, providing & fixing . strips for housing MCB's and other allied accessories etc. as required.(Make as per annex). Main and Sub main Panel = 25Cft.(APPROX)

25

-

-

... More
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.

-

-

-

... More
MCCB FP 400 Amp. 36 KA Microprocessor type (main incomer) complete with spreader links. All MCCB's shall have rotary handle and ICU=ICS =100%.

1

-

-

... More
TPN FP 40 Amp. 25 KA

4

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing panel. 40A

4

-

-

... More
Aluminium Bus Bar suitable for 500 Amp. 4 Strips of suitable length

1

-

-

... More
CT Set of suitable rating 200/5 A 1.15 VA burden

1

-

-

... More
Indicating Lamp(Led Type)

1

-

-

... More
Selector Switch

1

-

-

... More
Voltmeter (0-500) Volts Digital type

1

-

-

... More
Ammeter (0-500) Amps. Digital type

1

-

-

... More
MCCB FP 160 Amp. 36 KA Microprocessor type complete with spreader links All MCCB's shall have rotary handle and ICU=ICS =100%.

1

-

-

... More
Aluminium Bus Bar suitable for 300 Amp. 4 Strips of suitable length

3

-

-

... More
MCB Strip for 18 Nos. MCB's

6

-

-

... More
MCB SPN 16 AMP 10KA C-SERIES

18

-

-

... More
Supply, installation, testing & commissioning CPRI Approvedof GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode and providing and laying of 2 Nos. of 25 x 5 mm G.I strip from G.I rod upto the panel. The earthing pit should be covered with PVC cover.

1

-

-

... More
Supply and laying of 1.1kV grade , XLPE insulated, Aluminium conductor, Heavy Duty , Armoured cables of ratings 3.5 x150sqmm as per IS : 7098 Part-1 with latest amendments.

150

-

-

... More
Power wiring in PVC conduit of 3C x 2.5MM sq copper for each IDU from main panel to IDU

300

-

-

... More
Power wiring in PVC conduit of 4C x 10MM sq Copper for each ODU from main panel

150

-

-

... More
Supply, Installation, Testing and commissioning of 175kVA Automatic Servo Voltage Stabilizer oil cooled, outdoor type, suitable for operation on 3 phase 50Hz, 415V system with input voltage correction range of 160V to 460V, output 415V +/-1%, unbalanced input , unbalanced load, first filling of oil, overvoltage, undervoltage, overcurrent, short ciruit, protections and complete with by pass system. The servo shall be CPRI TESTED and certificate of test report shall be submitte to the department.

1

-

-

... More
CAMC for 2 year after Expiry of Defect liability period of 1 years.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.