Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Electrical and Electronics
Eprocure
Opening Date20 Jul 2021
Closing Date30 Jul 2021
Tender Amount₹ 55,60,000
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_PWDJK_131108_1Bid Award Id
ViewTender No
e-NIT No.EDJ/68 of 2021-22 Dated 16-07-2021Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://jkpwdrb.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supplying, Installation,Testing and Commissioning of VRV/VRF Air Conditioning of Examination Hall at PSC Building at Reshamgarh Jammu.
BOQ Items
INDOOR UNITS Supply, installtion,testing & commissioning of Round Flow Type cassette units with builtin drain pump with decorative panel(Nominal Capacity)
-
-
-
4 way-Round Flow Cassette Type Unit - 4.0 TR
5
-
-
4 way-Round Flow Cassette Type Unit - 3.0 TR
11
-
-
Hi- Wall unit 2.0TR Minimum
2
-
-
Remote Controller Installation , testing and commissioning of corded remote controller suitable for Indoor units and suitable to work on single phase 230 volt (+)(-) 10% 50 Hz AC supply.
18
-
-
Refrigerant Joints/ Headers Installation , testing and commissioning of imported Y-joints fittings and header to all indoor units at all floors including alignments of joints complete as required.
19
-
-
Hi - Wall Split Units Supply,Installation, testing & Commissioning of Split air conditioning unit with heat pump of2.0ton capacity in copper condensor in 3STAR rating
4
-
-
Refrigerant Piping Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported /fixed with suitable size of clamps /M.S hanger and all exterinal /exposed to sun piping shall run in M.S.painted cable tray with cover at site.
-
-
-
41.2 mm O.D. (insulation : 19mm)
110
-
-
38.1mm O.D. (insulation : 19mm)
110
-
-
34.9 mm O.D. (insulation : 19mm)
100
-
-
31.7 mm O.D. (insulation : 19mm)
125
-
-
28.6 mm O.D. (insulation : 19 mm)
85
-
-
25.4 mm O.D. (insulation : 19 mm)
170
-
-
22.2 mm O.D. (insulation : 13 mm)
130
-
-
19.1 mm O.D. (insulation : 13 mm)
125
-
-
15.9 mm O.D. (insulation : 13 mm)
130
-
-
12.7 mm O.D. (insulation :13 mm)
130
-
-
9.53mm O.D. (insulation : 13 mm)
270
-
-
6.4 mm O.D. (insulation : 13 mm)
100
-
-
CABLE TRAY Supplying and installing following size G.I cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including bolts & nuts, painting suspenders etc as required.
-
-
-
150 mm width X 50 mm depth X 1.6 mm thickness
50
-
-
300 mm width X 50 mm depth X 1.6 mm thickness
120
-
-
DRAIN PIPE Providing and fixing rigid CPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
-
-
-
32 mm dia
170
-
-
25 mm dia
50
-
-
Control & Transmission Wiring Providing & fixing control wiring of 2 core x 1.5 sqmm copper in PVC conduit pipe of 25mm dia including providing & fixing support @1.5mt distance C/C where it is not recessed between indoor units and their wired remote.
792.5
-
-
Providing & fixing control wiring of 2 core x 1.0 sqmm copper in PVC conduit pipe of 25mm dia including providing & fixing support @1.5mt distance C/C where it is not recessed between indoor units and their wired remote.
500
-
-
MAIN ELECTRICAL PANNEL Fabrication, supplying, installation testing and commissioning of following pannel CPRI approved made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly p0wder coated with provision for fixing of 1 no incomer MCCB, outgoing MCB's, , required number of sets of Aluminium Bus Bar, providing & fixing . strips for housing MCB's and other allied accessories etc. as required.(Make as per annex). Main and Sub main Panel = 25Cft.(APPROX)
25
-
-
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
-
-
-
MCCB FP 400 Amp. 36 KA Microprocessor type (main incomer) complete with spreader links. All MCCB's shall have rotary handle and ICU=ICS =100%.
1
-
-
TPN FP 40 Amp. 25 KA
4
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing panel. 40A
4
-
-
Aluminium Bus Bar suitable for 500 Amp. 4 Strips of suitable length
1
-
-
CT Set of suitable rating 200/5 A 1.15 VA burden
1
-
-
Indicating Lamp(Led Type)
1
-
-
Selector Switch
1
-
-
Voltmeter (0-500) Volts Digital type
1
-
-
Ammeter (0-500) Amps. Digital type
1
-
-
MCCB FP 160 Amp. 36 KA Microprocessor type complete with spreader links All MCCB's shall have rotary handle and ICU=ICS =100%.
1
-
-
Aluminium Bus Bar suitable for 300 Amp. 4 Strips of suitable length
3
-
-
MCB Strip for 18 Nos. MCB's
6
-
-
MCB SPN 16 AMP 10KA C-SERIES
18
-
-
Supply, installation, testing & commissioning CPRI Approvedof GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode and providing and laying of 2 Nos. of 25 x 5 mm G.I strip from G.I rod upto the panel. The earthing pit should be covered with PVC cover.
1
-
-
Supply and laying of 1.1kV grade , XLPE insulated, Aluminium conductor, Heavy Duty , Armoured cables of ratings 3.5 x150sqmm as per IS : 7098 Part-1 with latest amendments.
150
-
-
Power wiring in PVC conduit of 3C x 2.5MM sq copper for each IDU from main panel to IDU
300
-
-
Power wiring in PVC conduit of 4C x 10MM sq Copper for each ODU from main panel
150
-
-
Supply, Installation, Testing and commissioning of 175kVA Automatic Servo Voltage Stabilizer oil cooled, outdoor type, suitable for operation on 3 phase 50Hz, 415V system with input voltage correction range of 160V to 460V, output 415V +/-1%, unbalanced input , unbalanced load, first filling of oil, overvoltage, undervoltage, overcurrent, short ciruit, protections and complete with by pass system. The servo shall be CPRI TESTED and certificate of test report shall be submitte to the department.
1
-
-
CAMC for 2 year after Expiry of Defect liability period of 1 years.
2
-
-