Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 11,95,135 
Notes
Download

Costs

Summary

Construction Of 10 Roomed Double Storey Building At Ghss Goshbugh Bwo Electrification

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells/Legrand/Anchor/Schneider Make & shall be approved before execution of work.

32

586

18752

... More
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed inlc cost of Conduit. Conduit (Havells/Polycab/Finolex Make)

360

369

132840

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor/Schneider Make & shall be approved before execution of work.

24

680

16320

... More
Supply and Fixing of Modular blanking plates on existing Modular Plates.

10

24

240

... More
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor Make) & shall be approved before execution of work. inlc cost of Conduit.

-

-

-

... More
2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.

50

570

28500

... More
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/ Sub main in One run from Main Panel to Distribution Boards.

50

439

21950

... More
2x4 sq.mm+ 1x4 sq.mm (P+N+E) for Inverter Sub main in One run from Main Panel to Distribution Boards.

50

334

16700

... More
2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Inverter Circuit in One run from switch boards to Distribution Boards.

110

275

30250

... More
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand /Havells Make)

65

256

16640

... More
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand//HavellsMake)

-

-

-

... More
32Amp.

4

656

2624

... More
40Amp.

4

1250

5000

... More
63Amp.

4

1850

7400

... More
Supplying and Fixing of MCB 6way (4 + 18), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/Schneider Make)

4

4091

16364

... More
Supply/Installation/Testing and Commissioning of 18W + LED Conceal (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/HG Make.

130

1850

240500

... More
Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.

4

3200

12800

... More
Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells Make.3 Star

42

2200

92400

... More
Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/ Make. 3 Star

4

1950

7800

... More
Supply/Laying/Connecting and Commissioning of 95 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)

50

1450

72500

... More
Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make. (1) Normal Incomer: a) 200 Amp-4-Pole ,36kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved=01 No. b) 400 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set. (2) Inverter Incomer(Lighting & Computer Points): a) 100 Amp Single Phase Euroload (On-Load) Change over switch panel mounted = 01 No. b) 200 Amps TPN Al. Bus Bar Set = 01 Set & Phase indicator Set. Outgoing: (1) Normal outgoing for Heating/AC/Lighting/Inverter etc load (a) 32-Amp DP MCB = 04 No. as per site requirement) (b) 40-Amp DP MCB = 04 No. as per site requirement) (c) 63-Amp DP MCB = 04 No. as per site requirement)

1

85000

85000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.