Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Oct 2024
Closing Date19 Nov 2024
Tender Amount₹ 1,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

1

1562

1562

... More
Providing & fixing of fresh lighting point (5-6 amp) exposed,using double locked PVC channel 25x2 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire (P+N+E) complete with P/F of switch 5/6 amps F/T to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point.

1

893

893

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in Surface/recessed pvc conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

1

233

233

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1

275

275

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

1

334

334

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

1

439

439

... More
2 X 10 sq. mm + 1 X 6 sq. mm earth wire

1

570

570

... More
2 X 16 sq. mm + 1 X 6 sq. mm earth wire

1

712

712

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

1

410

410

... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire

1

537

537

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

1

754

754

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

1

754

754

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

1

1005

1005

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.

1

574

574

... More
Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.

1

894

894

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/recessed steel/ PVC conduit.

-

-

-

... More
1 x 1.5 sq. mm

1

45

45

... More
2 x 1.5 sq. mm

1

70

70

... More
3 x 1.5 sq. mm

1

95

95

... More
4 x 1.5 sq. mm

1

120

120

... More
5 x 1.5 sq. mm

1

155

155

... More
6 x 1.5 sq. mm

1

181

181

... More
7 x 1.5 sq. mm

1

216

216

... More
8 x 1.5 sq. mm

1

241

241

... More
9 x 1.5 sq. mm

1

285

285

... More
10 x 1.5 sq. mm

1

311

311

... More
2 x 2.5 sq. mm

1

98

98

... More
3 x 2.5 sq. mm

1

137

137

... More
4 x 2.5 sq. mm

1

177

177

... More
5 x 2.5 sq. mm

1

226

226

... More
6 x 2.5 sq. mm

1

265

265

... More
7 x 2.5 sq. mm

1

314

314

... More
8 x 2.5 sq. mm

1

353

353

... More
9 x 2.5 sq. mm

1

412

412

... More
10 x 2.5 sq. mm

1

451

451

... More
2 x 4 sq. mm

1

147

147

... More
3 x 4 sq. mm

1

206

206

... More
4 x 4 sq. mm

1

275

275

... More
5 x 4 sq. mm

1

337

337

... More
6 x 4 sq. mm

1

396

396

... More
7 x 4 sq. mm

1

457

457

... More
8 x 4 sq. mm

1

516

516

... More
9 x 4 sq. mm

1

579

579

... More
10 x 4 sq. mm

1

648

648

... More
2 x 6 sq. mm

1

216

216

... More
3 x 6 sq. mm

1

304

304

... More
4 x 6 sq. mm

1

402

402

... More
5 x 6 sq. mm

1

491

491

... More
6 x 6 sq. mm

1

598

598

... More
7 x 6 sq. mm

1

687

687

... More
8 x 6 sq. mm

1

785

785

... More
9 x 6 sq. mm

1

874

874

... More
10 x 6 sq. mm

1

967

967

... More
1 x 10 sq. mm

1

162

162.56

... More
1 x 16 sq. mm

1

255

255.33

... More
2 x 25 sq. mm

1

411

411.31

... More
3 x 35 sq. mm

1

567

567.3

... More
4 x 50 sq. mm

1

816

816.88

... More
1 x 70 sq. mm

1

1165

1165.8

... More
1 x 95 sq. mm

1

1536

1536.88

... More
Supplying and fixing of following sizes of medium class PVC conduit 2mm thick along with accessories in surface/recessed manner .the job also includes the cost of cutting the wall , rough plastering and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

1

128

128

... More
25 mm

1

145

145

... More
32 mm

1

184

184

... More
40 mm

1

228

228

... More
50 mm

1

284

284

... More
Supplying and Fixing 25 mm Double Locked PVC Channel 2 mm thick

1

41

41

... More
Supplying and Fixing DLP PVC Trunking compartment along with accessories divider, extra cover, end caps, internal angles external angles, flat angles etc.25 mm Double Locked PVC Channel 2 mm thick

-

-

-

... More
50x80

1

1402

1402.3

... More
50x105

1

1795

1795.84

... More
50x130

1

2466

2466.09

... More
50x145

1

3183

3183.15

... More
50x180

1

3504

3504.45

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.

-

-

-

... More
75 mm X 75 mm X 60 mm deep

1

178

178

... More
100 mm X 100 mm X 60 mm deep

1

209

209

... More
150 mm X 75 mm X 60 mm deep

1

216

216

... More
150 mm X 150 mm X 60 mm deep

1

311

311

... More
180 mm X 100 mm X 60 mm deep

1

245

245

... More
200 mm X 125 mm X 60 mm deep

1

323

323

... More
200 mm X 150 mm X 60 mm deep

1

355

355

... More
200 mm X 150 mm X 75 mm deep

1

363

363

... More
200 mm X 250 mm X 60 mm deep

1

468

468

... More
200 mm X 250 mm X 75 mm deep

1

488

488

... More
200 mm X 150 mm X 100 mm deep

1

412

412

... More
200 mm X 250 mm X 100 mm deep

1

506

506

... More
200 mm X 300 mm X 60 mm deep

1

525

525

... More
200 mm X 300 mm X 100 mm deep

1

561

561

... More
250 mm X 300 mm X 60 mm deep

1

607

607

... More
250 mm X 300 mm X 100 mm deep

1

653

653

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required

-

-

-

... More
5/6 amps switch

1

52

52

... More
2 way 5/6 A switch

1

64

64

... More
15/16 A switch

1

121

121

... More
3 pin 5/6 A socket outlet

1

69

69

... More
6 pin 15/16 A socket outlet

1

137

137

... More
5/6A 2 PinTOP

1

34

34.26

... More
5/6A 3 PinTOP

1

91

91.35

... More
16 A TOP

1

124

124.34

... More
15 A switch Socket Combine with out box

1

203

203.01

... More
15 A switch socket combine with box

1

294

294.36

... More
Fan Regulator Stepped type 1 Module

1

285

285.48

... More
Fan Regulator Stepped type 2 Module

1

386

386.98

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

1

103

103

... More
2 way 5/6 A switch

1

148

148

... More
15/16 A switch

1

156

156

... More
3 pin 5/6 A socket outlet

1

122

122

... More
6 pin 15/16 A socket outlet

1

197

197

... More
Bell push

1

140

140

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

1

369

369

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

1

40

40

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular Switches in recess etc. as required.

-

-

-

... More
1 or 2 Module (75mmX75mm)

1

298

298

... More
3 Module (100mmX75mm)

1

327

327

... More
4 Module (125mmX75mm)

1

343

343

... More
6 Module (200mmX75mm)

1

402

402

... More
8 Module (125mmX125mm)

1

454

454

... More
12 Module (200mmX150mm)

1

547

547

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

1

133

133

... More
3 Module

1

151

151

... More
4 Module

1

158

158

... More
6 Module

1

182

182

... More
8 Module

1

211

211

... More
12 Module

1

272

272

... More
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.

1

358

358

... More
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.

1

488

488

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

1

477

477

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

1

586

586

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including Connections etc. as required.

1

87

87

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

1

730

730

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

1

727

727

... More
Providing and fixing following rating adjustable type and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
100A , 16 KA , DPMCCB

1

3197

3197

... More
100 A, 16 KA,TPMCCB

1

3777

3777

... More
125 A, 16 KA,TPMCCB

1

4821

4821

... More
150 A, 16 KA,TPMCCB

1

5992

5992

... More
200 A, 16 KA,TPMCCB

1

7691

7691

... More
200 A, 25 KA,TPMCCB

1

11016

11016

... More
250 A, 25 KA,TPMCCB

1

12984

12984

... More
250 A, 35 KA,TPMCCB

1

13881

13881

... More
315 A, 35 KA,TPMCCB

1

21586

21586

... More
400 A, 35 KA,TPMCCB

1

21586

21586

... More
500 A, 35 KA,TPMCCB

1

25554

25554

... More
630 A, 50 KA,TPMCCB

1

27860

27860

... More
800 A, 50 KA,TPMCCB

1

36160

36160

... More
63A , 16 KA , FPMCCB

1

5266

5266

... More
100 A,30KA,FPMCCB

1

7723

7723

... More
125 A,36KA,FPMCCB

1

8209

8209

... More
160A , 36KA , FPMCCB

1

15836

15836

... More
200 A,36KA,FPMCCB

1

15206

15206

... More
250 A,36KA,FPMCCB

1

17510

17510

... More
400 A,36KA,FPMCCB

1

38880

38880

... More
400 A,50KA,FPMCCB

1

42665

42665

... More
630 A,50KA,FPMCCB

1

43092

43092

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way , Double door

1

2206

2206

... More
8 way , Double door

1

2573

2573

... More
12 way , Double door

1

2315

2315

... More
16 way, Double door

1

3141

3141

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
4 way (4 + 12), Double door

1

4091

4091

... More
6 way (4 + 18), Double door

1

4974

4974

... More
8 way (4 + 24), Double door

1

5967

5967

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door

1

7512

7512

... More
8 way (4 + 24), Double door

1

10165

10165

... More
12 way (4 + 36), Double door

1

12833

12833

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

1

256

256

... More
Single pole and neutral

1

599

599

... More
Double pole

1

656

656

... More
Triple pole

1

1007

1007

... More
Triple pole and neutral

1

1228

1228

... More
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
a)40A TPN

1

2732

2732.54

... More
b)63A TPN

1

2774

2774.63

... More
c)40A TP

1

2076

2076.05

... More
d)63A TP

1

2174

2174.57

... More
e)40A DP

1

1404

1404.33

... More
f)63A DP

1

1522

1522.55

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

1

14

14

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

1

1169

1169

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess each 848 along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required

1

1592

1592

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required

1

1621

1621

... More
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

2590

2590

... More
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

4107

4107

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

269

269

... More
Replacement/supply and fixing of following accessories

-

-

-

... More
a)      LED Lamp 9 watt with minimum lumens 900

1

288

288

... More
b) LED Lamp 12 watt with minimum lumens 1200

1

261

261

... More
Replacement/supply and fixing of following luminaries as specified below.

-

-

-

... More
Surface type LED luminaries 12-16 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1000 with burning hours greater than 40000 Hourshaving system lumens =90 lm/watt

1

850

850.09

... More
Surface type LED luminaries 15-20 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1200 with burning hours greater than 40000 Hours having system lumens =90 lm/watt

1

1209

1209.16

... More
Hanging light (fancy type light) with min 8Watts LED lamp

1

1642

1642.57

... More
10-12 Watt LED Bulkhead luminaire with burning hours = 50000 Hours.

1

1221

1221.48

... More
Recessed type LED luminaries 12-16 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1000 with burning hours = 50000 Hours having system lumens =90 lm/watt

1

943

943.39

... More
Recessed type LED luminaries 15-20 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1200 with burning hours = 50000 Hours having system lumens =90 lm/watt

1

1164

1164.75

... More
4 feet long LED batten 6000/6500k Light with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 4000 and maximum wattage24 including connection with multistrand copper conductor 3 core cable etc as required at site with burning hours = 50000 Hours having system lumens 110 Lm/watt.

1

1256

1256.11

... More
4 feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 2000 and maximum wattage 20 including connection with multistrand copper conductor 3 core cable etc as required at sitewith burning hours = 50000 Hours having system lumens 110 Lm/watt.

1

1074

1074.74

... More
2 feet long LED batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 1000 and maximum wattage 15 including connection with multistrand copper conductor 3 core cable etc as required at site with burning hours = 50000 Hours having system lumens 110 Lm/watt.

1

746

746.35

... More
2'x2', 36-40W LED light fixture suitbale for ceiling recessed applications. The fixture has a power consumption of 36-40W and producing a system lumen output of minimum 3600 lumen. The fixture is designed for 50, 000 hrs of operational life Housing made of Metallic CRCA powder coated body Withstands 440Volt fast transit & Surge Protection 2KV. system Luminous efficieny 110 lm/ W, CRI 80. The fixture has an operating voltage range 220-240V AC 50 Hz ,withstand 300Volt input for continuous operation & driver designed to withstand casing temperature of 85 degree C.

1

3283

3283.79

... More
Providing and Fixing of 4x1 LED light panel with max 36-40 wattage lu/watt 100

1

3731

3731.6

... More
Providing fixing well glass lights 30 Watt 6000/6500k having high pressure diecast aluminum housing with poly carbonate antiglare diffuser including connection complete as required at site. (Surface Type)

1

2963

2963.31

... More
Providing & Fixing 20W Spot Light Al. Housing Lu/W = 100 Surface type

1

3736

3736.08

... More
Dismantling and repair of led batten by way repairing/replacing led driver and refitting the same in position after cleaning.

1

274

274

... More
P/f of Phenolic Laminated Sheet 3 mm thick .

1

205

205

... More
P/f of fibers sheet of following thickness.

-

-

-

... More
a)  6 mm

1

795

795

... More
b)  8 mm

1

1003

1003

... More
c)  12 mm

1

1258

1258

... More
P/f of Acrylic milky sheets of following thickness.

1

38

38

... More
a)  2 mm

1

397

397

... More
b)  3 mm

1

513

513

... More
P/laying of 3 core flexible copper wire 2.5 mm sq.

1

234

234

... More
P/laying of 3 core flexible copper wire 4 mm sq.

1

354

354

... More
Supply and Fixing including making of connections complete job of 3P Contactor AC1 160A, AC3 130A, 240/440Volt.

1

24873

24873

... More
Supply and Fixing including making of connections complete job of Contactor AC1 165A, AC3 130A, 240/440Volt.

1

25493

25493

... More
Providing and fixing following rating of Four pole onload front operated Changeover Swicth in cubicle panel, making connections, etc. as required..

-

-

-

... More
40 A

1

6451

6451

... More
63 A

1

6873

6873

... More
100 A

1

8661

8661

... More
125A

1

12988

12988

... More
160 A

1

13833

13833

... More
200 A

1

15935

15935

... More
250 A

1

22038

22038

... More
320A

1

24972

24972

... More
400A

1

33916

33916

... More
630A

1

39248

39248

... More
800A

1

59233

59233

... More
1000A

1

107961

107961

... More
Providing and fixing pf Spreader links for MCCB's

-

-

-

... More
a)  4 links set for 125-200 A

1

450

450

... More
c)  4 links set for 250A

1

820

820

... More
d)  4 links set for 400A

1

1804

1804

... More
d)  4 links set for 630A

1

1955

1955

... More
P/F of MCB boxes (pvc) with strip

-

-

-

... More
a)   2 way

1

109

109

... More
b)   4 way

1

164

164

... More
P/F of below mentioned Geyser accessories as per site requirements

-

-

-

... More
a) P/f of connection pipes for Geysers of various sizes

-

-

-

... More
12''

1

235

235

... More
18''

1

268

268

... More
24''

1

295

295

... More
30''

1

355

355

... More
36''

1

372

372

... More
b) Foundation nut bolts.

1

23

23

... More
c) Geysers indicator.

1

32

32

... More
c) Vocal copper tube.

1

571

571

... More
d) Element copper glass.

1

455

455

... More
e) Flung washer.

1

57

57

... More
Replacement/Supplying and fixing of Geyser element 1500/2000 watts (power pack/prince/Theeta make)

-

-

-

... More
a) Coil type (long)

1

389

389

... More
b) Coil type (short)

1

397

397

... More
c) Triangular type.

1

513

513

... More
d) Round type.

1

463

463

... More
e) Thermostat Geyser.(Long/short)(insertion type)

1

165

165

... More
e) Thermostat Geyser.( Capillary type)

1

511

511

... More
Replacement of Geyser element Coil type 2000 watts (for Venus magma Geysers)

1

869

869

... More
Replacement of Geyser element Coil type 3000 watts .

1

1143

1143

... More
Replacement of Geyser element Coil type 6000 watts .

1

2285

2285

... More
SITC of Electric Heater / Geyser of capacities as mentioned below with following parameters . 1.Energy saving. 5 Star Certification by BEE 2. Provision of Temperature regulation by means of external Knob 3. Power Rating:- 220/ 230V, 50 Hz, Single Phase. 4. Maximum Rated Pressure.= 8 bar 5. Installation Type Vertical / Horizontal mounted as per site requirement 6. Body Type:- Rust, water proof and Shock Proof outer body with attractive looks and corrosion resistant inner tank made of cold rolled steel ,resistant to hard water. 7. Element Type:- glass coated heating element to prevent from corrosion and hard water. 8.Safety Valve maximum pressure =8 bar maximum 9. Energy efficiency feature:- Should have high density PUF insulation for energy Saving 10. Anti syphon system to prevent back flow of water. 11. Should have Indicating Lamps for ON & CUTT OFF. 12. Confirming to :IS 2082:2018 , IS 302-1, IS 302-2-21

-

-

-

... More
a)  25 litre (2KW)

1

12746

12746

... More
b)  35 litre (2KW)

1

15882

15882

... More
c)  50 litre (2KW)

1

18977

18977

... More
d) 100 litre (3KW)

1

33108

33108

... More
a) Repairing of Blowers (heat Convectors) by way of changing internal wiring,screw, complete.

1

140

140

... More
b) Wall mount Blowers Electronic Type by changing internal wiring and relays etc

1

224

224

... More
i) P/f heating coil 3 way, 4 way, 5 way.

1

199

199

... More
ii) P/f of motor complete

1

224

224

... More
iii) P/f of thermostat blower

1

57

57

... More
iv) P/f of knob

1

75

75

... More
v) Blower Switch

1

111

111

... More
vi) Blower Fan

1

44

44

... More
Suplying of wall mount heat convectors/ blower 230volt 50HZ Single phase 2000 watt with adjustable 3 heat setting, ,Auto thermal Cut ,Twin fan blade: 50degree, well balanced Copper conductors ,with a swing stand PVC Sheathed cord, 15A, 3 pin moulded plug

1

8583

8583

... More
Rewinding of fans

-

-

-

... More
a) Wall mount fan 400 mm

1

432

432

... More
b) Ceiling fan

-

-

-

... More
i) 1200 mm

1

513

513

... More
ii) 1400 mm

1

580

580

... More
Rewinding of exhaust fans of various sizes.

-

-

-

... More
a) 9”

1

456

456

... More
b) 12”

1

513

513

... More
c) 15”

1

687

687

... More
d) 24”

1

1080

1080

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

1

181

181

... More
Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required.

1

282

282

... More
P/f of accessories for various types of fans.

-

-

-

... More
a)  Ball bearing set

1

165

165

... More
b)  Capacitor/condenser.

1

91

91

... More
c)  Top lead.

1

116

116

... More
d)  Rubber bush.

1

33

33

... More
e)  Resistance.

1

66

66

... More
f)   Blades for all types of fans.

1

397

397

... More
g)  Gear griller.

1

78

78

... More
h)  Switch plate of wall mount fan.

1

171

171

... More
i)   Nut bolts.

1

16

16

... More
j)   Ceiling fan rod.

1

77

77

... More
k)  Ceiling fan clip.

1

40

40

... More
l)    Wall mount fan cover net.

1

339

339

... More
Supply installation testing and commissioning of following sizes of metallic type exhaust fans with Bird guard to protect fan in running condition ,Double ball bearing with Heavy duty motor .

-

-

-

... More
i)  9"

1

1821

1821

... More
ii) 12"

1

3146

3146

... More
iii) 15"

1

4336

4336

... More
ii) 18"

1

5357

5357

... More
iii) 24"

1

12323

12323

... More
Supply installation testing and commissioning of following sizes of plastic body exhaust fans shutter type with Heavy duty motor Rated speed = 1400 RPM . RAte voltage -220 to 240 Volts .

-

-

-

... More
i)  150 mm

1

1516

1516

... More
ii) 200 mm

1

1722

1722

... More
ii) 225 mm

1

1722

1722

... More
iii) 250 mm

1

1836

1836

... More
iv) 300 mm

1

2098

2098

... More
Making of holes for installing of exhaust fans and P/F of wooden frames of various sizes. Complete with civil work in all respects.

-

-

-

... More
i)  12”

1

352

352

... More
ii)  15”

1

528

528

... More
iii) 18”

1

674

674

... More
iv) 24”

1

806

806

... More
P/f of fan hooks of various types S type, U type, J type.

1

108

108

... More
SITC of Wall mount fans 400 mm with Plastic Body as specified below 1.Motor AC 2.Governing standard I.S.2997 (Latest) 3.Power Consumption: Approx. 100 Watts 4.Power supply Single phase AC 230V, 50Hz 5.Speed: 1200 -1400 rpm with regulator 6.Sweep: 400 mm 7.Air Flow: 72-80 m3/min. 8..motor protection through thermal 9.overload protection device 10.It should have minimum 3 levels of speed control. Features:Suitable for mounting on walls with easy mounting system, Noise level shall be within limits adjustable upward and downward tilt mechanism

1

3197

3197

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, Ceiling fan, BLDC type class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019),THD less than 10% and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

1

3402

3402

... More
Installation testing & commissioning of fans copper wound heavy duty.

-

-

-

... More
a)  Wall mount fans 400/300 mm

1

162

162

... More
b)  Ceiling fans 1200 mm

1

219

219

... More
c)  Exhaust fans double ball bearing

-

-

-

... More
i)   9”

1

216

216

... More
ii) 12”

1

270

270

... More
iii) 15”

1

324

324

... More
iv) 18”

1

378

378

... More
v) 24”

1

432

432

... More
Supplying and Fixing Snap On PVC Trunking compartment along with accessories divider, extra cover, end caps, internal angles external angles, flat angles etc.

-

-

-

... More
50x80mm

1

1647

1647

... More
50x105mm

1

2095

2095

... More
Supplying of timber KD/Fir or equalent

1

1639

1639

... More
External Electric Network (Part B)

-

-

-

... More
Earthing

-

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

1

7403

7403

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.

1

6756

6756

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.

1

13632

13632

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

14945

14945

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

1

55

55

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

1

1050

1050

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

1

156

156

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

1

1675

1675

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

1

762

762

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

1

1255

1255

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

1

264

264

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
a)Upto 35 sq. mm

1

418

418

... More
b)Above 35 sq. mm and upto 95 sq. mm

1

437

437

... More
c)Above 95 sq. mm and upto 185 sq. mm

1

456

456

... More
d)Above 185 sq. mm and upto 400 sq. mm

1

512

512

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
a)Upto 35 sq. mm

1

291

291

... More
b) Above 35 sq. mm and upto 95 sq. mm

1

309

309

... More
c)Above 95 sq. mm and upto 185 sq. mm

1

328

328

... More
d)Above 185 sq. mm and upto 400 sq. mm

1

384

384

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
a)Upto 35 sq. mm

1

216

216

... More
b) Above 35 sq. mm and upto 95 sq. mm

1

234

234

... More
c)Above 95 sq. mm and upto 185 sq. mm

1

253

253

... More
d)Above 185 sq. mm and upto 400 sq. mm

1

310

310

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
a)Upto 35 sq. mm

1

136

136

... More
b)Above 35 sq. mm and upto 95 sq. mm

1

154

154

... More
c) Above 95 sq. mm and upto 185 sq. mm

1

174

174

... More
d)Above 185 sq. mm and upto 400 sq. mm

1

230

230

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
a)Upto 35 sq. mm

1

40

40

... More
b) Above 35 sq. mm and upto 95 sq. mm

1

62

62

... More
c) Above 95 sq. mm and upto 185 sq. mm

1

83

83

... More
d)Above 185 sq. mm and upto 400 sq. mm

1

145

145

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.

-

-

-

... More
a)Upto 35 sq. mm

1

30

30

... More
b)Above 35 sq. mm and upto 95 sq. mm

1

49

49

... More
c)Above 95 sq. mm and upto 185 sq. mm

1

68

68

... More
d)Above 185 sq. mm and upto 400 sq. mm

1

124

124

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
a)Upto 35 sq. mm (clamped with 1mm thick saddle)

1

59

59

... More
b)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1

140

140

... More
c)Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

1

165

165

... More
d)Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

1

244

244

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
a)Upto 35 sq. mm (clamped with 1mm thick saddle)

1

49

49

... More
b)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1

99

99

... More
c)Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

1

124

124

... More
d)Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

1

200

200

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

1

632

632

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

1

549

549

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
a) Upto 120 sq. mm

1

567

567

... More
b) Above 120 sq. mm and upto 400 sq. mm

1

623

623

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
a) Upto 120 sq. mm

1

391

391

... More
b) Above 120 sq. mm and upto 400 sq. mm

1

448

448

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/HUME/ METAL pipe as required.

-

-

-

... More
a) Upto 120 sq. mm

1

83

83

... More
b) Above 120 sq. mm and upto 400 sq. mm

1

145

145

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.

-

-

-

... More
a) Upto 120 sq. mm

1

68

68

... More
b) Above 120 sq. mm and upto 400 sq. mm

1

124

124

... More
Laying of one number XLPE power cable of 33 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
a) Upto 120 sq. mm

1

572

572

... More
b) Above 120 sq. mm and upto 400 sq. mm

1

629

629

... More
Laying of one number additional XLPE power cable of 33 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
a) Upto 120 sq. mm

1

397

397

... More
b) Above 120 sq. mm and upto 400 sq. mm

1

454

454

... More
Laying of one number XLPE power cable of 33 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
a) Upto 120 sq. mm

1

89

89

... More
b) Above 120 sq. mm and upto 400 sq. mm

1

150

150

... More
Laying of one number XLPE power cable of 33 KV grade of following size in the existing masonry open duct as required.

-

-

-

... More
a) Upto 120 sq. mm

1

73

73

... More
b) Above 120 sq. mm and upto 400 sq. mm

1

130

130

... More
Disconnecting and extraction of following sizes existing LT cables PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade from existing masonry open duct,cable tray /cable hungers as required.

-

-

-

... More
a) Upto 35 sq. mm

1

22

22

... More
b) Above 35 sq. mm and upto 95 sq. mm

1

32

32

... More
c) Above 95 sq. mm and upto 185 sq. mm

1

54

54

... More
d) Above 185 sq. mm and upto 400 sq. mm

1

86

86

... More
Excavation of existing cable trench for locating of cable fault by way of excavation , extractionremoving of cable from cable trench .the job includes cost of refilling the trench after rectifiying the cable fault.

-

-

-

... More
a) Upto 35 sq. mm

1

22

22

... More
b) Above 35 sq. mm and upto 95 sq. mm

1

32

32

... More
c) Above 95 sq. mm and upto 185 sq. mm

1

54

54

... More
d) Above 185 sq. mm and upto 400 sq. mm

1

86

86

... More
LV CABLE JOINTING & END TERMINATION

-

-

-

... More
Supplying and making end termination with and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
2 X 6 sq. mm (19mm)

1

214

214

... More
2 X 10 sq. mm (19mm)

1

214

214

... More
2 X 16 sq. mm (22mm)

1

229

229

... More
2 X 25 sq. mm (22mm)

1

229

229

... More
2 X 35 sq. mm (25mm)

1

274

274

... More
2 X 50 sq. mm (28mm)

1

305

305

... More
3 X 10 sq. mm (22mm)

1

228

228

... More
3 X 16 sq. mm (25mm)

1

240

240

... More
3 X 25 sq. mm (25mm)

1

240

240

... More
3 X 35 sq. mm (28mm)

1

306

306

... More
3 X 50 sq. mm (32mm)

1

326

326

... More
3 X 70 sq. mm (35mm)

1

366

366

... More
3 X 95 sq. mm (38mm)

1

467

467

... More
3 X 120 sq. mm (45mm)

1

518

518

... More
3 X 150 sq. mm (50mm)

1

589

589

... More
3 X 185 sq. mm (57mm)

1

746

746

... More
3 X 225 sq. mm (62mm)

1

841

841

... More
3 X 240 sq. mm (62mm)

1

859

859

... More
3 X 300 sq. mm (70mm)

1

989

989

... More
3½ X 25 sq. mm (28mm)

1

270

270

... More
3½ X 35 sq. mm (32mm)

1

324

324

... More
3½ X 50 sq. mm (35mm)

1

355

355

... More
3½ X 70 sq. mm (38mm)

1

397

397

... More
3½ X 95 sq. mm (45mm)

1

511

511

... More
3½ X 120 sq. mm (45mm)

1

528

528

... More
3½ X 150 sq. mm (50mm)

1

599

599

... More
3½ X 185 sq. mm (57mm)

1

758

758

... More
3½ X 225 sq. mm (62mm)

1

856

856

... More
3½ X 240 sq. mm (62mm)

1

874

874

... More
3½ X 300 sq. mm (70mm)

1

1011

1011

... More
3½ X 400 sq. mm (82mm)

1

1306

1306

... More
4 X 10 sq. mm (25mm)

1

237

237

... More
4 X 16 sq. mm (28mm)

1

270

270

... More
4 X 25 sq. mm (28mm)

1

270

270

... More
4 X 35 sq. mm (32mm)

1

326

326

... More
4 X 50 sq. mm (35mm)

1

359

359

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
2 X 16 sq. mm

1

2341

2341

... More
2 X 25 sq. mm

1

2676

2676

... More
2 X 35 sq. mm

1

2676

2676

... More
2 X 50 sq. mm

1

2676

2676

... More
3 X 16 sq. mm

1

2341

2341

... More
3 X 25 sq. mm

1

2676

2676

... More
3 X 35 sq. mm

1

2676

2676

... More
3 X 50 sq. mm

1

2676

2676

... More
3 X 70 sq. mm

1

3632

3632

... More
3 X 95 sq. mm

1

3798

3798

... More
3 X 120 sq. mm

1

4901

4901

... More
3 X 150 sq. mm

1

4901

4901

... More
3 X 185 sq. mm

1

4901

4901

... More
3 X 225 sq. mm

1

5313

5313

... More
3 X 240 sq. mm

1

5313

5313

... More
3 X 300 sq. mm

1

6596

6596

... More
3½ X 25 sq. mm

1

2676

2676

... More
3½ X 35 sq. mm

1

2676

2676

... More
3½ X 50 sq. mm

1

2676

2676

... More
3½ X 70 sq. mm

1

3632

3632

... More
3½ X 95 sq. mm

1

3798

3798

... More
3½ X 120 sq. mm

1

4901

4901

... More
3½ X 150 sq. mm

1

4901

4901

... More
3½ X 185 sq. mm

1

4901

4901

... More
3½ X 225 sq. mm

1

5313

5313

... More
3½ X 240 sq. mm

1

5313

5313

... More
3½ X 300 sq. mm

1

6596

6596

... More
3½ X 400 sq. mm

1

8603

8603

... More
4 X 16 sq. mm

1

2341

2341

... More
4 X 25 sq. mm

1

2676

2676

... More
4 X 35 sq. mm

1

3632

3632

... More
4 X 50 sq. mm

1

3632

3632

... More
Providing and laying of spans of 3 ½ core/2 core XLPE Al. cable Armored of various sizes as mentioned below in place of damaged/burnt out / fresh ones of 1.1KV as per IS 7098/ II/ 85 with latest amendements

-

-

-

... More
10 mm sq 2-core

1

216

216

... More
16 mm sq. 2-core

1

246

246

... More
25 mm sq. 2-core

1

278

278

... More
25 mm sq. 3 ½ core

1

404

404

... More
35 mm sq. 3 ½ core

1

499

499

... More
50 mm sq. 3 ½ core

1

662

662

... More
70 mm sq. 3 ½ core

1

889

889

... More
95 mm sq. 3 ½ core

1

1110

1110

... More
120 mm sq. 3 ½ core

1

1382

1382

... More
150mmsq. 3.5 core

1

1608

1608

... More
185mmsq 3.5 core

1

2036

2036

... More
240 mm sq. 3 ½ core

1

2592

2592

... More
300 mm sq. 3 ½ core

1

2891

2891

... More
400 mm sq. 3 ½ core

1

3720

3720

... More
500 mm sq. 3 ½ core

1

4771

4771

... More
630 mm sq. 3 ½ core

1

6505

6505

... More
HV CABLE JOINTING & END TERMINATION

-

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
70 - 95 sq. mm

1

13155

13155

... More
120 - 185 sq. mm

1

16165

16165

... More
240 -300 sq. mm

1

17549

17549

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE alum conductor cable of 11 KV grade as required :

-

-

-

... More
70 - 95 sq. mm

1

19708

19708

... More
120 - 185 sq. mm

1

21708

21708

... More
240 -300 sq. mm

1

24619

24619

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
70 - 95 sq. mm

1

31472

31472

... More
120 - 185 sq. mm

1

41130

41130

... More
240 -300 sq. mm

1

45243

45243

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required :

-

-

-

... More
70 - 95 sq. mm

1

21427

21427

... More
120 - 185 sq. mm

1

32493

32493

... More
240 -300 sq. mm

1

36953

36953

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required :

-

-

-

... More
70 - 95 sq. mm

1

34088

34088

... More
120 - 185 sq. mm

1

44500

44500

... More
240 -300 sq. mm

1

77376

77376

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required

-

-

-

... More
70 - 95 sq. mm

1

59228

59228

... More
120 - 185 sq. mm

1

75198

75198

... More
240 -300 sq. mm

1

106512

106512

... More
POLE ERECTION

-

-

-

... More
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.

1

9367

9367

... More
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)

1

7386

7386

... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.

-

-

-

... More
a) 32 mm dia

1

567

567

... More
b) 40 mm dia

1

636

636

... More
LV OVER HEAD LINE WORK

-

-

-

... More
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.

1

292

292

... More
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required.

1

322

322

... More
Erection of galvanised 'D' iron clamps and insulator on pole as required.

1

83

83

... More
Fixing of MV lightning arrestor as required.

1

181

181

... More
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) Bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.

1

1595

1595

... More
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres Length along the pole for protection of under ground cable as required.

1

2769

2769

... More
Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.

1

3894

3894

... More
Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.

1

5300

5300

... More
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.

1

2875

2875

... More
HV OVER HEAD LINE WORK

-

-

-

... More
Supply and erection of 75mm x 40mm x 6mm/100mmx50mmx 6mm channel iron cross-Arms including drilling holes for insulator pins & nuts and bolts and painting one coat of red Oxide and minimum two coats of Paint as required at site.( To be fabricated as per drawing /requirement at site)

1

140

140

... More
Supply erection of angle iron of all sizes for structures/cross-Arms of sizes including drilling holes for insulator pins & nuts and bolts and painting one coat of red Oxide and minimum two coats of Paint as required at site.( To be fabricated as per drawing /requirement at site)

1

140

140

... More
P/f of P.G clamp

-

-

-

... More
a)0.05/0.05

1

199

199

... More
b)0.1/0.1

1

656

656

... More
Opening and dismantling cable/from change over switches or ACB’s from L.T panel after necessary repairing. Such new cable end terminals, dressing of cables, changing of rusty nut bolts cable gland, if found damaged/broken.

1

2886

2886

... More
P/f of bus bar chamber (of appropriate size) TPN factory fabricated complete with lockable, hinged type door with Almunium busbar earthing nut bolt and painting powder coated, Heavy Duty

-

-

-

... More
a)100 A 4 way

1

10259

10259

... More
b) 200 A 8 ways

1

18127

18127

... More
c) 250 A ---do---

1

41800

41800

... More
d) 400 A ---do---

1

45480

45480

... More
Supply and laying of following sizes of XLPE/ PVC insulated copper wire Unarmoured, overall PVC sheathed 1.1 KV grade cables

-

-

-

... More
a) 25 mm sq single core

1

671

671

... More
b) 35 mm sq single core

1

910

910

... More
c) 50 mm sq single core

1

1315

1315

... More
Opening, repairing, maintenance & general overhauling of servo stabilizer by way of de-taching the core (by way of using chain block pulley), removing of sledge from dimmer stat coils and other submerged parts reinforcing the insulation wherever necessary. The job also includes servicing of servo mechanism checking and rectification of gear synchronizes system, automotive voltage regulator circuits, motorizing units and other allied electrical components. Replacement of damaged electrical and mechanical parts complete servicing and over hauling ( to be provided seperately). The job includes draining of T-oil and re-filling of the same.

-

-

-

... More
a) 750 KVA

1

7185

7185

... More
b) 600 KVA

1

6418

6418

... More
c) 400 KVA

1

4535

4535

... More
d) 250/200 KVA

1

3804

3804

... More
e)  100 KVA

1

3226

3226

... More
Supplying and Replacement Reparing of damaged electrical and mechanical parts,complete servicing and over hauling for above stabilizers

-

-

-

... More
a)Ammeter selector switch

1

630

630

... More
b)Input/out put selector switch

1

630

630

... More
c)Electronic Control card complete for AC voltage stabilizers

1

3974

3974

... More
d)Electro magnetic relay 24 Volt DC

1

1358

1358

... More
e)Carbon brushes

1

307

307

... More
f)Brush arm

1

679

679

... More
g)Commutator tube and plug assembly

1

795

795

... More
j)Bakalite core guide

1

969

969

... More
h)Brass slip ring

1

456

456

... More
i)Core guide assembly

1

1159

1159

... More
j)Complete terminal stud. Assembly

1

662

662

... More
k)Mica red fiber other insulating material

1

397

397

... More
l)Brush arm assembly

1

1176

1176

... More
m)Aluminum clamping assembly

1

630

630

... More
n)Hand wheel

1

910

910

... More
o)Limit switch lower with push button

1

571

571

... More
p)Limit switch higher with push button

1

577

577

... More
q)E-point plates

1

339

339

... More
r)Dimmer base fiber plates for coils

1

456

456

... More
s)Insulator Dimmer spacers

1

56

56

... More
t)Terminal Brush

1

679

679

... More
u) P/f of 10 kg torque 220 volt AC servo motor for stabilizers

1

5713

5713

... More
Providing, fabrication and fixing of checkered M.S.Iron Plate of following thickness.

-

-

-

... More
6mm thick

1

165

165

... More
P/f of CT of following ratings with tapings (AE/Kappa make) Resin cast for LT Panels

-

-

-

... More
a) 200/5A

1

1460

1460

... More
b) 250/5A

1

1460

1460

... More
c) 400/5A

1

1460

1460

... More
d) 600/5A

1

1623

1623

... More
e) 1000/5A

1

2567

2567

... More
a) P/f of Digital voltmeter 0-500 volt

1

2511

2511

... More
b) P/f of Digital Am-meter of 0-500 A

1

2511

2511

... More
Providing of below mentioned items for maintenance of electric equipments

-

-

-

... More
a) Petroleum Jelly

1

513

513

... More
b) Carbon tetrachloride CCl4

1

332

332

... More
Repairing of transformer by way of changing Bush rods, bushes etc on H.T/L.T side.and cleaning The job includes providing and fixing of insulated gaskets, rubberized cork washers, nuts and bolts etc. after draining of oil from the transformer and re-filling of the same after complete inspection.(For 630/1000 KVA)

1

7036

7036

... More
Providing and fixing of full threaded nuts and bolts of various sizes.

1

174

174

... More
Providing/ fixing of Pad clamps for 630 KVA

1

1325

1325

... More
Providing/ fixing of Pad clamps for 1000 KVA

1

2484

2484

... More
Providing/filling of Xmer oil filtered

1

171

171

... More
Filtration of T.oil with transportation

1

51

51

... More
Providing/filling of Silica gel in the breather

1

1159

1159

... More
Providing of LT porcelain bushes with bush cups.for 630 KVA

1

232

232

... More
Providing of LT bush rods for 630 KVA X-mers.

1

2070

2070

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
a)150 mm dia

1

646

646

... More
b)250 mm dia

1

757

757

... More
c)300mm dia

1

922

922

... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.

-

-

-

... More
c)40mm

1

397

397

... More
b)50mm

1

507

507

... More
c)100mm

1

1378

1378

... More
d)150mm

1

2100

2100

... More
Providing and laying of PVC pipe B-class of following size.

-

-

-

... More
50mm dia

1

350

350

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

1

118

118

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

1

161

161

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

1

259

259

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)

1

387

387

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

1

538

538

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

1

226

226

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

1

269

269

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

1

368

368

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)

1

495

495

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

1

646

646

... More
33KV VCB

-

-

-

... More
Rectification,Re-Alignment,setting right the electrical section of 33 kv breakers which includes replacement of damaged parts. 33KV C & R Panel

1

3623

3623

... More
Rectification,Re-Alignment,setting right the mechanical section of 33 kv breakers which includes replacement of damaged parts. 33KV C & R Panel

1

4697

4697

... More
Replacement of damaged clamps ( Bi-metallic ) confirming to IS :1285 standards for 33KV VCB , 33KV LA ,33KV Isolator

1

537

537

... More
Replacement of damaged equipments ( 33 kv VCB bushes complete assembly ) confirming to IS:2099 standards.

1

12680

12680

... More
Replacement of damaged equipments ( 33 kv HV bushes of transformers complete assembly ) confirming to IS:2099 standards.

1

3623

3623

... More
Replacement of damaged equipments ( 11 kv LV bushes of transformers complete assembly ) confirming to IS:2099 standards.

1

2349

2349

... More
Replacement of damaged equipments ( 33 kv P.T bushes of transformers complete assembly ) confirming to IS:2099 standards.

1

3623

3623

... More
Replacement of damaged equipments ( 33 kv C.T bushes of transformers complete assembly ) confirming to IS:2099 standards.

1

3254

3254

... More
Repairing of following electric 33 KV Gang operating switch by way of cleaning, mopping with petroleum jelly, changing of rusty nut bolts, link pieces, rods, clips etc. as per site requirement.

1

7583

7583

... More
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm X 60 cm ), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required

1

5891

5891

... More
Providing and Fixing of Guy wire 7/14 SWG

1

270

270

... More
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30KV(rms) and nominal discharge current rating of 10 KA (Station class ) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.

1

18651

18651

... More
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.

1

2838

2838

... More
Supplying and erection of three piece nonlinear resistor type lightning arrestor (Station Type) suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 10 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.

1

5940

5940

... More
Supplying and erection of 200A 11KV Dropout fuse unit with 80 amp fuses, galvanised channel , Post type insulator, tinned copper contacts complete in all respects (post type)

1

9109

9109

... More
Providing and Fixing of 33 KV pin insulator

1

745

745

... More
Providind and Fixing of 33 KV pin with washers/nuts (Galvanized)

1

497

497

... More
Supply and erection of 33 KV,3 pole, Horizontal mounting type Isolator double break with post type insulators with earth switch (assembled) confirming to IS 9921( pt 1:5) & other relevent IS with latest ammendements with galvanised channels post type insulators , tinned copper contacts , arching horns, GI operating Handle with locking arrangements etc. complete as required at site.

1

52559

52559

... More
Supplying & installing 11 KV 3 phase, 200 Amp. Vertical type gang operated switch with hot dip galvanised channels post type, insulator, tinned copper contacts, arcing horns, GI pipe gang operating handle, limit switch etc. locking arrangements etc. complete in all respects.

1

17141

17141

... More
Supply mechanical and manual transportation and erection of following size ST pole complete with base plate & top cap conforming to IS 2713 with upto date ammendments complete with red oxide coat and aluminium paint coat .the job includes cost of stone pad along with cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required as per REC standard 0.4 cum for 7 mtr , 0.5 cum for 9 mtr pole and 0.7 cm for 13 mtr pole 0.4 cm for 7 mtr pole . the job includes cost of 3 mtr long 40 mm Dia GI pipe strip of size 25 x 3 mm for pole earthing

-

-

-

... More
410 SP15 ST poles 8 mtr Long

1

22715

22715

... More
410 SP33 ST poles 9 mtr Long

1

32266

32266

... More
410 SP56 ST poles 13 mtr Long

1

55173

55173

... More
Supply & Erection of flange mounted 6mtrs long hot dip galvanized Octangonal Pole of following height made from 3 mm thick HT Steel plate, having top dia-70mm & bottom dia of 130 mm complete with average coating thickness of atleast 65 micron. The galvanizing shall be done in single dipping. There shall not be any circumferential welding. Pole shall have door of approximate 300 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. Pole shall have galvanized base plate of size 220 mm x 220mm x 12 mm thick with provision of holes for 4 no. 20mm dia bolt. including supplying and fixing the following in the window box provided for cable termination a) Supplying and fixing 6mm thick laminated mounted sheet inside the window mounted and including Earthing complete by G.I Pipe 40mm or G.I Rod 20mm 2.5 Mtr long through G.I Strip. b) Supplying and fixing 63 Amps terminal block, suitable for 10 sq.mm conductor- 04 nos & shorting links- 05 nos. on DIN Channel including providing and fixing DIN Channel of suitable length- 01 nos on the existing laminated sheet. c) Supplying and fixing 6 Amps, SP MCB, “C” curve 10 KA- 02 nos, Earth stud 02 nos, welded at suitable height, washers, springs washers & nuts.

1

16740

16740

... More
Supply fixing of galvanized pole bracket (arms) of approved design suitable for above mentioned /existing pole completed in all respects with proper fabrication for installation of above street lighting fittings on the top of steel tubular poles. a) Double arm 1 meter long with an angle as per requirement. (Arm)

1

1620

1620

... More
b) Single arm 1 meter long with an angle as per requirement. (Arm)

1

1080

1080

... More
Providing, installation, testing and commissioning of LED Street light luminaire as per following specification:- 1. Input voltage : 150 V to 270 V 2. LDE lamp efficiency : Min 95 to 110 lumens/watt 3. Power factor : 0.90 4. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 70-80 W 7. Luminous flux : 7000 to 8000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): 15% with test certificate 11. Colour rendering index : Ra 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture

1

4860

4860

... More
Providing & making RCC foundation of 1300mm(H)X600mmX600mm size with 1:2:4(1Cement, 2 coarse, 4 Stone aggregate) complete with 12mm dia. M.S. bar for reinforcement along with centering & shuttering i/c supplying & fixing 600mm long , 16mm dia J type G.I, coated foundation bolt/ Anchor bolt with template suitable for ornamental / 6.0mtr octogonal Pole.The job includes cost of 100mm dia 600mm length corgated pipe complete with excavation the soil & refilling, ramming, curing etc. as reqd. For 06 meter Octogonal Galvanized Pole

1

7560

7560

... More
Providing, installation, testing and commissioning of LED Street light luminaire as per following specification:- 1. Input voltage : 150 V to 270 V 2. System efficiency : Min 100 to 110 lumens/watt 3. Power factor : 0.90 4. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 40-50 W 7. Luminous flux : 4000 to 5000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): 15% with test certificate 11. Colour rendering index : Ra 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture

1

3780

3780

... More
Supply, installation, testing and commisioning of LED flood light luminariesin place of existing non functional High mask Lights as per following specification 1. Input voltage : 150 V to 270 V 2.Lumens : Min 10500 3. Power factor : 0.90 4. Life expecting : more than 40,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 110-120W 7. Luminous flux : 10500 to 12000 lumens 8. Colour Temperature : 5,500 to 6,500 K with test certificate 9. Ingress protection : IP 65/IP 66 as per IS/IEC60529-2001 with test certificate. 10. Total harmonic distortion (THD): 15% with test certificate 11. Colour rendering index : Ra 80 12. Working Temperature : 0 deg to 50 deg 13. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture

1

8100

8100

... More
Repairing/maintenance of electrical fittings of various types by way of opening /dismantling and changing of led Driver refitting after making necessary complete as per site requirement. From steel poles of height

-

-

-

... More
upto 4.5 metre

1

864

864

... More
Above 4.5 metre and upto 7 metre

1

1188

1188

... More
Above 7 metre and upto 9 metre

1

1296

1296

... More
Repairing/maintenance of electrical fittings by way of opening /dismantling, changing of led Driver refitting after making necessary complete as per site requirement.

-

-

-

... More
High mast led fittings from High mask pole 60-80 Watt

1

2160

2160

... More
High mast led fittings from High mask pole 100 -120 watt

1

1944

1944

... More
MISC.CIVIL ITEMS

-

-

-

... More
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:

-

-

-

... More
All kinds of soil :

-

-

-

... More
1 meter from cutting edge

1

471

471

... More
25 meter beyond 1 m from cutting edge

1

566

566

... More
50 meter beyond 1m from cutting edge

1

662

662

... More
Ordinary Rock

-

-

-

... More
1 meter from cutting edge

1

1045

1045

... More
25 meter beyond 1 m from cutting edge

1

996

996

... More
50 meter beyond 1m from cutting edge

1

1083

1083

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

1

215

215

... More
Deduct for not consolidation by ramming and watering while re-filling with sand and or good soil in cable/ pipe laying.

1

131

131

... More
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:

-

-

-

... More
1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)

1

7155

7155

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1

6347

6347

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

1

6317

6317

... More
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1

5338

5338

... More
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)

1

5301

5301

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

1

4774

4774

... More
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

1

4351

4351

... More
Centering and shuttering including strutting, propping etc. and removal of form work for: 4.6.1 Foundations, footings, bases for columns

1

283

283

... More
REINFORCED CEMENT CONCRETE Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

7659

7659

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1

6852

6852

... More
CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix:

-

-

-

... More
1 : 4 ( 1 cement : 4 fine sand)

1

281

281

... More
1 : 6 ( 1 cement : 6 fine sand)

1

261

261

... More
DG Sets Part C

-

-

-

... More
Dismantling, opening and repair of 24 volt self starters from 320 KVA DG sets for checking of damaged parts etc. This job includes its transportation loading un loading including refixing at site. (Cummins make DG sets)

1

1944

1944

... More
Replacement of below mentioned parts by new one in place of existing out of order and non functional.

-

-

-

... More
1. Armature long size (Hypo/Locust make).

1

8316

8316

... More
2. Main coils

1

1836

1836

... More
3. Auxiliary coils

1

1512

1512

... More
4. Carbon brush’s

1

517

517.32

... More
5. Brush holder

1

756

756

... More
6. Celey(killi) bush

1

120

120.96

... More
7. Big bush.

1

162

162

... More
8. Contacts male and female

1

594

594

... More
9. Clutch Plate

1

48

48.6

... More
10. Main gear

1

723

723.6

... More
11. Solenoid switch.

1

7614

7614

... More
12. Connection bolts in let and out let

1

84

84.24

... More
13. Complete rewinding of commutater and armature.

1

4212

4212

... More
Tappet setting of different DG sets of various models and make, the job includes repairing and setting right of rocker arms nuts and bolts, exhaust intake and injectors nuts and bolts (adjusting screws). The job also includes replacement of rocker arm gaskets and tappet cover gaskets with “O” rings including dismantling and refixing at site of below mentions DG sets.

-

-

-

... More
320 KVA DG set.

1

3624

3624.48

... More
380 KVA DG set.

1

4485

4485.24

... More
600 KVA DG set.

1

5940

5940

... More
Repairing of different capacity DG set PT pumps including replacement of all worn out /out of order/non -functional parts by new one in place of existing out of order parts. The job includes dismantling and refixing at site providing and fixing of new gaskets including setting right of timing between engine and pumps of below mention DG sets.

-

-

-

... More
320 KVA DG set.

1

39013

39013.92

... More
380 KVA DG set.

1

43632

43632

... More
600 KVA DG set.

1

48816

48816

... More
Repairing of different capacity DG set injectors(Cumminsmake) by way of replacement of all parts by new one in place of existing out of order parts, the job includes dismantling and refixing of these injectors of below mentioned DG sets.

-

-

-

... More
320 KVA DG set.

1

5598

5598.72

... More
380 KVA DG set.

1

6415

6415.2

... More
600 KVA DG set.

1

7776

7776

... More
Repairing of different capacity DG sets Electronic Activator including replacement of all parts by new one in place of existing out of order parts. The job includes dismantling and refixing at site providing and fixing of new gasket of below mention DG sets Cummins make Activator of below mention DG sets.

-

-

-

... More
1.      320 KVA DG set

1

1941

1941.84

... More
2.      380 KVA DG set

1

3236

3236.76

... More
3 600 KVA DG set

1

3726

3726

... More
Repairing of Turbo chargers of different models and capacity Cummins make DG sets by way of complete opening and refixing of minor/major new kits in place of existing out of order and non functional parts on below mention DG sets as under.

-

-

-

... More
320 KVA

-

-

-

... More
Minor Kit

1

7767

7767.36

... More
Major kit

1

11653

11653.2

... More
380 KVA

-

-

-

... More
Minor kit

1

7767

7767.36

... More
Major kit

1

14240

14240.88

... More
600 KVA

-

-

-

... More
Minor kit

1

9212

9212.4

... More
Major kit

1

19278

19278

... More
Cleaning of exhaust pipes silencers with using of chemicals and cleaning of exhaust smoke from inner sides of pipes for avoiding of over heating of DG sets. The job includes dismantling of fluntch nuts and bolts including replacement of gaskets etc of below mention DG sets.

-

-

-

... More
320 KVA

1

2849

2849.04

... More
380 KVA

1

3201

3201.12

... More
600 KVA

1

4050

4050

... More
Repairing, cleaning of different capacities of below mentioned DG set radiators by way of using chemical and radiwash AX1013358 for DG Sets etc. The job includes repairing of damaged tubes by way of using soldering etc including replacement of upper and lower gaskets at site, also refixing the same on existing foundation of below mention DG sets.

-

-

-

... More
320 KVA

1

9914

9914.4

... More
380 KVA

1

9914

9914.4

... More
600 KVA

1

13500

13500

... More
Repairing of Cylinder heads of 320/380 KVA D.G Set (Cummins Make) by way of dismantalling and refixing at site after repairing at workshop .The job includes valve griding incuding its transportation and loading and unloading .

1

3780

3780

... More
Replacement of following items of Cylinder heads

-

-

-

... More
320 KVA DG set

-

-

-

... More
a) Valve intake and Exhaust

1

3780

3780

... More
b) Guide valve

1

540

540

... More
c) Head Gasket Set (Complete set )

1

5940

5940

... More
380 KVA

-

-

-

... More
a) Valve intake and Exhaust

1

5940

5940

... More
b) Guide valve

1

810

810

... More
c) Head Gasket Set (Complete set )

1

7020

7020

... More
Opening & Repairing of DC 24 volt Dynamo by way of replacement of below mentioned parts by new one in place of existing out of order parts at work shop. The job includes cost of refixing .

1

777

777.6

... More
Repairing of armature

1

2845

2845.8

... More
Carbon brushes set

1

205

205.2

... More
Belt Dynamo

1

388

388.8

... More
Brush holder

1

70

70.2

... More
Bearings

1

259

259.2

... More
Opening & Repairing of self starters of 380 KVA DG set, 320 KVA DG sets (Cummins make ) by way of complete dismantling checking repairing refixing including transportation up to work shop for checking of damaged parts. The job includes replacement of below mention parts by new one as under.

1

2327

2327.4

... More
Solenoid switch

1

7767

7767.36

... More
Carbon brushes

1

1941

1941.84

... More
Self Bendix

1

1941

1941.84

... More
Repairing of comutator

1

5566

5566.32

... More
Brush holder

1

2071

2071.44

... More
Main coils

1

1293

1293.84

... More
Bush (3 nos)

1

1049

1049.76

... More
Kelly boush

1

205

205.2

... More
Belt B-62

1

699

699.84

... More
Servicing/checking of Stanford/Kirloskar/Caterpillar alternator 380/320 KVA DG’s set by way of complete checking of starter and field coils, in let and out let connections. The job includes filling of greasing to the bearings, two coats of recommended varnishing to the coils with the help of skilled persons.

-

-

-

... More
320KVA

1

20628

20628

... More
380KVA

1

22680

22680

... More
600KVA

1

25380

25380

... More
Repairing of AMF panel of 380 KVA DG set by way of checking of all AC and DC wiring connections with the help of skilled persons the job includes replacement of below mentioned items by new one as under.

1

4142

4142.88

... More
AC Relay MSP 4P 240 A (saizer make)

1

1049

1049.76

... More
DC Relay Omron My 2N -24 DC

1

1049

1049.76

... More
Bakelite HRC fuses 6 AMP

1

140

140.4

... More
HRC fuse RT-14-20-500V 1690W 2A

1

145

145.8

... More
HRC fuse RT-14-20-500V 1690W10A

1

151

151.2

... More
Earth fault relay 230 Vac (Teknik make)

1

1699

1699.92

... More
Delay time relay (Teknik make)

1

1620

1620

... More
Repair of 24/48 volt boost and trickle type battery charger by of way replacement of below mentioned new one in place non -functional ones.The job includes handling transportation loading and un loading as required

-

-

-

... More
a) Diode

1

540

540

... More
b) Rotary switch

1

864

864

... More
c) voltmeter

1

648

648

... More
d) ammeter

1

648

648

... More
e) Battery Terminal (PVC Type )

1

324

324

... More
f) Kit Kat 63Amp

1

270

270

... More
g) Indicator Lamp

1

162

162

... More
h) Mcb Single pole

1

226

226.8

... More
i) Boost and trickle Switch

1

216

216

... More
e) rewinding of coil Ac/DC

1

216

216

... More
Supply, fixing testing and commissioning of IEVR 3 pieces and 1 piece for below mentioned DG sets by new one in place of existing out of order. The job includes dismantling of existing one and refixing of new with the help of skilled persons at site.

-

-

-

... More
200 KVA DG set IVER

1

18241

18241.2

... More
320 KVA DG set IVER

1

21362

21362.4

... More
380 KVA –d0-

1

21362

21362.4

... More
600 KVA –d0-

1

22680

22680

... More
Carrying out M. Oil changing of different capacity of DG sets by way of draining of exhaust M oil from oil chamber, filters etc including cleaning all parts by way of filling of new M oil after complete cleaning all related parts at site of below mentioned DG sets by way of fixing of new filters as under.

-

-

-

... More
Service Charges for 320 KVA as described above

1

3780

3780

... More
M oil filter with ‘O’ ring

1

486

486

... More
D oil filter with ‘O’ ring

1

540

540

... More
By pass filter with ‘O’ ring

1

810

810

... More
Air cleaner filter (inner and outer)

1

7128

7128

... More
Service Charges for 380 KVA as described above

1

3780

3780

... More
Kit super bye pass filter element part no. KIT3879488

1

1188

1188

... More
Element lube oil filter kit part no. KIT3401544

1

3672

3672

... More
Element coolant part no. KIT4104821

1

486

486

... More
filter fuel part no. KIT4962810

1

1620

1620

... More
Kit air cleaner element part no. KIT3238358

1

7128

7128

... More
Belt V Ribbed P 3289124

1

1620

1620

... More
Service Charges for 600KVA as described above (Caterpillar Make)

1

5400

5400

... More
oil filter part No. 1R1808

1

6480

6480

... More
Diesel oil filter part No. 1R0749

1

7560

7560

... More
Air cleaner filter (Element AS-P )

1

48600

48600

... More
Filter GP (Water Seperator )

1

8100

8100

... More
Supply handling transportation loading and un loading of below mentioned items for various capacities for smooth running of Dg sets of below mentioned items. (Caterpillar make DG)

-

-

-

... More
Engine Oil (Cat DEO Cl4 15W-40 )

1

518

518.4

... More
Coolant (ELC Premix )

1

432

432

... More
Supply handling transportation loading and un loading of below mentioned items for various capacities for smooth running of Dg sets of below mentioned items. (Cummins make DG)

-

-

-

... More
a) 12 volt 25 plate 180 AMP hour service free battery

1

22680

22680

... More
b) M oil Volvo CF4 15 W 40 API/ M oil GTX 15 W 40 GTD

1

388

388.8

... More
c) M.oil premium Blue 15 W 40 CH4 API (P50000006)

1

453

453.6

... More
d) K.oil super (P 82-030-10-0-20)

1

394

394.2

... More
e) Distil water

1

32

32.4

... More
f) Sulphuric acid (concentrated)

1

64

64.8

... More
g) Inhibiter corrosion Coolent

1

410

410.4

... More
h) Dhoti cloth 90x200 Cm

1

37

37.8

... More
Replacement of in let hose pipe with clamp

1

777

777.6

... More
Replacement of Out let turbo charger hose with clamp

1

518

518.4

... More
Replacement of M oil in let pipe

1

699

699.84

... More
Replacement of M oil out let pipe

1

1229

1229.04

... More
Supply and fixing of Rubber packing of 1pieces for coupler of DG set Alternator and Engine as per site requirement

1

1080

1080

... More
Supply and fixing of Bolts for coupler

1

194

194.4

... More
Repairing of HSD/water pipe in the all DG sets by way of replacement of below mention parts by new one in place of existing out of order as under by way of P/F of G.I fittings C-class

-

-

-

... More
a)      Elbow with dia ½” / ¾”

1

37

37.8

... More
b)      Tee with dia ½” / ¾”

1

59

59.4

... More
c)      Socket with dia ½” / ¾”

1

32

32.4

... More
d)     Union with dia ½” / ¾”

1

118

118.8

... More
e)      Nipple with length 2” /4” /6” (with dia 1/2”)

1

32

32.4

... More
f)       Nipple with length 2” 4” 6” (with dia 3/4”)

1

59

59.4

... More
g)   Dead plug ½” / ¾”

1

21

21.6

... More
h)      Ball value ½”

1

432

432

... More
i)        Ball value ¾”

1

540

540

... More
P/l of G.I pipes B-class 20’ long

-

-

-

... More
a)      ½” pipe 20’ long

1

1134

1134

... More
b)      ¾” pipe 20’ long

1

1620

1620

... More
P/F of C.P accessories

-

-

-

... More
a)      Angle value

1

864

864

... More
b)      Bib cock

1

810

810

... More
Repairing of rolling shutters long/short by way repairing of rolling drum , side plates ,safety cover refixing including welding/nut bolt and greasing and checking of damaged parts.

1

1296

1296

... More
lifting spring of suitable size

1

972

972

... More
Lifting gear box compete upper and lower

1

3780

3780

... More
Side channels as per site

1

162

162

... More
Lifting handle

1

864

864

... More
Lifting gear rod as per site

1

540

540

... More
Repairing/complete rewinding of (1 HP) self priming motor the job includes dismantling refixing including transportation to w/shop and vise verse.

1

2165

2165.4

... More
Supply, Fixing, Testing and commissioning of complete synthetic hose / rubber kit high pressure for 320/380 DG sets. The job includes fixing of suitable clamps as per the site requirement.

-

-

-

... More
long size

1

2886

2886.84

... More
short size

1

1553

1553.04

... More
Supply/ fixing, testing and commissioning of electronic control panel for 380 KVA DG set ( Cummins Make ). The job includes checking of DC circuit with fuses etc. (Part No: 4083935)

1

61498

61498.44

... More
Supply, laying, testing and commissioning of 20 mm² ACSR Conductor (Squirrel)

1

26

26.32

... More
Supply, laying, testing and commissioning of 30 mm² ACSR Conductor (Weasel)

1

50

50.22

... More
Supply, laying, testing and commissioning of 50 mm² ACSR Conductor (Rabbit)

1

82

82.54

... More
Supply, laying, testing and commissioning of 100 mm² ACSR Conductor (Dog)

1

161

161.78

... More
Supply, laying, testing and commissioning of 150 mm² ACSR Conductor (Wolf)

1

268

268.07

... More
Supply, laying, testing and commissioning of 200 mm² ACSR Conductor (Panther)

1

349

349.02

... More
Supply, laying, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

1

272

272

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

1

748

748

... More
Pipe-Type Chemical earthing which includes digging a suitablesized pit in which a 3 Metre long copper pipe is inserted vertically and the pit is back-filled by a mixture of charcoal, salt, and bentonite in a ratio so as to achieve earth value of less thhan 2 ohms.

1

11000

11000

... More
Suppy, installation, testing and commissioning of 11 kV Isolator Double Break, 3-pole, 630 Amps, Horizontal Mounting Type , with earth switch

1

39092

39092

... More
Providing of Wireman

1

926

926.9

... More
Providing of Lineman

1

926

926.9

... More
Providing of Electrician

1

926

926.9

... More
Providing of Technician

1

926

926.9

... More
Providing of Cable Jointer

1

926

926.9

... More
Providing of Fitter, Grade 1

1

926

926.9

... More
Providing of Painter

1

844

844.1

... More
Providing of Khallasi

1

762

762.45

... More
Providing of Beldar / Coolie

1

762

762.45

... More
Solder Jointing

1

13

13.8

... More
Hire Charges for Truck (5 Ton)

1

4600

4600

... More
Providing of Engineer

1

1725

1725

... More
Providing of Software Engineer

1

2415

2415

... More
Supply, installation, testing and commissioning of 12V, 75Ah Sealed Lead Acid Battery

1

8900

8900

... More
Supply, installation, testing and commissioning of 12V, 100Ah Sealed Lead Acid Battery

1

10500

10500

... More
Supply, installation, testing and commissioning of 12V, 42Ah Sealed Lead Acid Battery

1

7500

7500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.