Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Dec 2024
Closing Soon26 Dec 2024
Tender Amount₹ 75,26,130 
Notes
Download

Costs

Summary

Construction Of New Degree College Building At Larnoo Phase 1st By Way Of Internal Electrification

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.)

60

670

40200

... More
Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent)

-

-

-

... More
i.3 pin 5A - 10A socket.

50

122

6100

... More
ii. indicator.

50

100

5000

... More
Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Havells/ Polycab/ Anchor/ Finolex/KEI/RR make in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl. cost of conduit

600

130

78000

... More
Supply, installation, testing and commissioning of 12-15 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100im/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series.

600

1250

750000

... More
Supply, installation, testing and commissioning of 18 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100im/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series.

100

1650

165000

... More
Supply, installation, testing and commissioning of 20 Watt (4 feet long) LED wall mounted batten ( tube lights) having aluminum housing, minimum 100im/w, average life 50000 hours (Commercial series) The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of one year reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro).

50

1250

62500

... More
Supply, installation, testing and commissioning of 3 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of necessary connections.

160

2200

352000

... More
Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd.

160

369

59040

... More
Supply, installation, testing and commissioning of 250-300 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton).

20

1950

39000

... More
Supply, installation, testing and commissioning of 400mm sweep wall fans, incl. cost of ceiling rose and making of and necessary connections. (Havells/ Philips/ Crompton/ Anchor).

4

3250

13000

... More
Supply, installation, testing and commissioning of 100Watt LED Flood lighting luminaries having aluminum body, minimum 100im/w, the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.

10

8500

85000

... More
Supply, installation, testing and commissioning of 600 mm sweep industrial type exhaust fans (Sample to be got approved), incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections.

6

5500

33000

... More
Supplying and fixing of modular blanking plates on existing modular plate and switch box ,excluding modular plate as required.

100

40

4000

... More
Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excl. cost of conduits(Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent).

-

-

-

... More
2 x 1.5 sq.mm + 1x 1.5 sq. mm earth wire

800

88

70400

... More
2 x 2.5 sq.mm + 1x 2.5 sq. mm earth wire

800

130

104000

... More
2 x 4 sq.mm + 1x 4 sq. mm earth wire

600

189

113400

... More
2 x 6 sq.mm + 1x 6 sq. mm earth wire

600

294

176400

... More
4 x 10 sq.mm + 2x 6 sq. mm earth wire

600

860

516000

... More
4 x 16 sq.mm + 2x 6 sq. mm earth wire

600

1150

690000

... More
Supply and fixing of following sizes of medium class PVC conduits along with accessories, recessed in walls, including cutting of walls and making good the same.

-

-

-

... More
A. 25 mm dia.

800

145

116000

... More
B. 32 mm dia.

200

184

36800

... More
Supply and installation of 32A modular plug/socket with 32A DP MCB for ACs

6

1450

8700

... More
Supply and drawing 1 run of UTP 4 pair CAT 6 LAN cable of solid copper conductors in the existing conduit.

2000

57

114000

... More
Supply and fixing of 1 or 2 module GI box (75 mm x 75 mm) along with modular base and cover plate for modular switches (for internet)

240

298

71520

... More
Supply and fixing of RJ 45 modular sockets.

120

693

83160

... More
Supply and fixing of modular telephone socket outlet on the existing modular plate and switch box including connections.

115

148

17020

... More
Supply and drawing 2 pair 0.5 mm dia. FRLS PVC insulated copper conductor, unarmored telephone cable in the existing conduit.

1000

38

38000

... More
Supplying and fixing following size of perforated painted with powder coating M S cable trays with perforation not more than17.5% in convenient sections, joined with connectors, suspended from the ceiling with M S suspenders including bolts and nuts, painting suspenders etc. as required.

-

-

-

... More
i. 200mm x 50mm x 1.6mm

100

689

68900

... More
ii. 300mm x 50mm x1.6mm

80

777

62160

... More
iii. 375mm x 50mm x2.0mm

80

1015

81200

... More
Supply and fixing of Double door surface/ recess mounting , Vertical/ Horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. .

-

-

-

... More
i. 6 Way (4 +18) .

12

4974

59688

... More
ii. 8 Way (4 +24)

12

5967

71604

... More
Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.

270

256

69120

... More
Supply, installation, testing and commissioning of 40/63 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.

12

1134

13608

... More
Supply, installation, testing and commissioning of 40/ 63A TP&N rating 240/ 415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.

12

2450

29400

... More
Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick in size.

3

2500

7500

... More
Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 3 mtr. Long GI earthing electrode, 80 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound.

4

11500

46000

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar ( 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.

48

2200

105600

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)

-

-

-

... More
Normal Incoming

-

-

-

... More
630 Amp, 50 KA, FP MCCB incl. Spreader links

1

45000

45000

... More
ON Load Change Over Switch FP 400 amp. (Front operated)

1

42500

42500

... More
Aluminum Bus Bar 1000 Amp set of 4 strips

1

12500

12500

... More
Aluminum Bus Bar 1000 Amp set of 4 strips

1

10200

10200

... More
Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set, 2 Nos, etc.

2

8500

17000

... More
Outgoing

-

-

-

... More
250 Amp, 36 KA, FP MCCB incl. Spreader links

4

28500

114000

... More
200 Amp, 36 KA, FP MCCB incl. Spreader links

4

22500

90000

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar ( 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. (TWO PANELS FOR GROUND/FIRST FLOOR)

48

2200

105600

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) (TWO PANELS FOR GROUND/FIRST FLOOR)

-

-

-

... More
Normal Incoming

-

-

-

... More
250 Amp, 36 KA, FP MCCB incl. Spreader links (1no. x 2 panel)

2

28500

57000

... More
Aluminum Bus Bar 600 Amp set of 4 strips (1set. x 2 panel)

2

6500

13000

... More
200 Amp, 36 KA, FP MCCB incl. Spreader links (1no. x 2 panel)

2

22500

45000

... More
Aluminum Bus Bar 400 Amp set of 4 strips (1 set. x 2 panel)

2

10200

20400

... More
Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, etc. (2 set. x 2 panel)

4

7500

30000

... More
Outgoing

-

-

-

... More
100 Amp, 50 KA, FP MCCB incl. Spreader links (5no. x 2 panel)

10

19500

195000

... More
63 Amp, 50 KA, FP MCCB incl. Spreader links (5no. x 2 panel)

10

17500

175000

... More
Space for 24 way MCBs (1job. x 2 panel)

2

4500

9000

... More
Supply, laying, connecting and commissioning of 300 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped. ( under ground).

100

3250

325000

... More
Supply, laying, connecting and commissioning of 185 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped. ( under ground).

70

2095

146650

... More
Supply, laying, connecting and commissioning of 95 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped.

50

1050

52500

... More
Supply, laying, connecting and commissioning of 70 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped.

50

850

42500

... More
Supplying and laying of DWC HDPE (Double Wall Corrugated High Density Polyethylene) pipe, 200 mm dia.(OD – 200 mm & ID – 175 mm) ISI marked along with all accessories like sockets, bends, couplers, etc. with fitting and cutting, jointing, etc. (under ground), including excavation and refilling the trench after laying the pipes.(complete job)

150

668

100200

... More
Supply, installation , testing and commissioning of 3 star rating 1.5 Ton Inverter type split Air Conditioners suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector internal unit with one indoor and one outdoor unit. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle iron stand fitted with nut/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC insulated copper cable and a battery operated wireless remote unit. The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. (Daikin/ Blue Star/ LG).

6

65000

390000

... More
Supply, installation , testing and commissioning of relay type voltage stabilizer suitable for 2 Ton AC operating from input voltage 90-260Volt thereby producing output voltage of 230volts +_ 3%. (4 KVA)

6

8500

51000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.