Public Works Department Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Feb 2025
Closing Date22 Feb 2025
Tender Amount₹ 19,88,000 
Notes
Download

Costs

Summary

Restoration/upgradation At Joint Director Poultary Cum Llp By Way Of Electric Works At Hariparbat Srinagar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/salzer/ anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.)

1050

285

299250

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make.)

85

450

38250

... More
Wiring for 6- 10 amp power plug/ lighting ckt with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/salzer/ anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

950

220

209000

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make.)

20

550

11000

... More
Supplying and fixing following modular switch/ socket ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make.) with modular plate and cover including switch box and connections etc. as required.

-

-

-

... More
5/10 amps switch

18

120

2160

... More
15/16 amp switch

7

185

1295

... More
3 pin 5/10 amp socket outlet

7

148

1036

... More
6 pin 15/20 amp socket outlet

7

215

1505

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/salzer/ anchor/ equivalent as directed by engineer incharge.)equivalent as directed by engineer incharge.), single core cable in surface/ recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit as required.

-

-

-

... More
(a) 2 X 1.5 sq. mm

550

110

60500

... More
(d)2 X 6 sq. mm + 1 X 6 sq. mm earth wire

230

350

80500

... More
( b )2 X 10 sq. mm + 1 X 6 sq. mm earth wire

230

510

117300

... More
Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, complete

-

-

-

90

95

8550

... More
Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends.

110

35

3850

... More
Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux /Wipro make / sample to be approved before installation..

5

1350

6750

... More
S/F testing and comm. Of 36 W + 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD10%.( commercial series) CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux /Wipro make / sample to be approved before installation..

15

750

11250

... More
Supply installation testing and comm. of flood light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.

4

6500

26000

... More
S/F testing and comm. Of MCB's of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ L&T ./equivalent make as directed by engineer incharge.

-

-

-

... More
a) 6-32 Amp SP MCB

150

256

38400

... More
b) 40-63amp DP MCB

20

1015

20300

... More
c) 20-32amp DP MCB

12

950

11400

... More
Supply installation testing and commissioning of 400mm wall fan crompton /Usha/ havell make

2

2850

5700

... More
Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates.

30

24

720

... More
Supply installation testing and comm. Of 450mm sweep exhaust fan industrial type Heavy Duty metallic of havell /Bajaj/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.

22

8500

187000

... More
Supply installation testing and comm. Of 300mm sweep exhaust fan industrial type Heavy Duty metallic of havell /Bajaj/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.

19

7900

150100

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board ( legrand/ Shinider/ABB make), 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
16 way, Double door ( 14+2)

8

2850

22800

... More
10 way, Double door ( 8+2)

8

2050

16400

... More
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block.

267

48

12816

... More
Supply fixing testing and comm. Of LED lamp 15 Watt ( warm type) Philips/ Havell /Wipro make.

266

250

66500

... More
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.

4

10200

40800

... More
Supply laying ( Partly Over head/ Partly underground) , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.

-

-

-

... More
c) 50 sq.mm 3.5core

185

650

120250

... More
Engaging of Highly Skilled Labour/Electrician for carrying out desmentaling of damaged/Defunct wiring system, fixtures, conduits and other allied works as required at site. As directed by the engineer at site.

3

6500

19500

... More
Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel , duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement)

12

2150

25800

... More
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.

-

-

-

... More
Normal INCOMING:

-

-

-

... More
(a) 160 amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.

1

12500

12500

... More
b) 4 No. of Aluminium Bus Bar of 300 Amp.

1

3358

3358

... More
c)Digital meters and phase indicators -1 set.

1

6500

6500

... More
d) onload Change over switch 100 Amp for generator.Front operated.

1

4500

4500

... More
e) 4 No. of Aluminium Bus Bar of 200 Amp.

1

3250

3250

... More
c)Digital meters and phase indicators -1 set.

1

6500

6500

... More
Inverter Incommer

-

-

-

... More
(a) 100 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.

1

4500

4500

... More
(b) 200 Amp 2 strip bus bar

1

1350

1350

... More
c)Digital meters and phase indicators -1 set.

1

6500

6500

... More
OUTGOING:

-

-

-

... More
c) 40-63amp DP MCB

9

1050

9450

... More
c) space for 12 way MCB's

1

900

900

... More
Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel , duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement)

12

2150

25800

... More
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.

-

-

-

... More
Normal INCOMING:

-

-

-

... More
(a) 160 amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.

1

12500

12500

... More
b) 4 No. of Aluminium Bus Bar of 300 Amp.

1

3250

3250

... More
c)Digital meters and phase indicators -1 set.

1

6500

6500

... More
d) onload Change over switch 100 Amp for generator.Front operated.

1

4500

4500

... More
e) 4 No. of Aluminium Bus Bar of 200 Amp.

1

3250

3250

... More
c)Digital meters and phase indicators -1 set.

1

6500

6500

... More
Inverter Incommer

-

-

-

... More
(a) 100 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.

1

4500

4500

... More
(b) 200 Amp 2 strip bus bar

1

1350

1350

... More
c)Digital meters and phase indicators -1 set.

1

6500

6500

... More
OUTGOING:

-

-

-

... More
c) 40-63amp DP MCB

10

1050

10500

... More
c) space for 12 way MCB's

1

900

900



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.