Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Jul 2024
Closing Date11 Jul 2024
Tender Amount₹ 2,72,000
Costs
EMD
₹ 5,440Document Cost
₹ 600Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_252037_1Bid Award Id
ViewTender No
Fresh e-NIT No.EDJ/36 of 2024-2025 Dated 03-07-2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://jkpwdrb.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of Veterinary Hospital For First Aid Center (FAC) Raika Labana Electrical part. (2nd Call)
BOQ Items
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
-
-
-
... More
1 x 1.5 sq. mm
80
3600
45
... More
2 x 1.5 sq. mm + 1x 1.5 sq. mm earth wire
50
4750
95
... More
2 x 2.5 sq. mm + 1x 2.5 sq. mm earth wire
150
20550
137
... More
4 x 6 sq. mm + 2 x 6 sq. mm earth wire
10
5980
598
... More
Supplying and fixing following modular switch/ socket on the
existing modular plate & switch box including connections but
excluding modular plate etc. as required.
-
-
-
... More
5/6 amp switch
60
6180
103
... More
3 pin 5/6 amp socket outlet
10
1220
122
... More
15/16 amp switch
10
1560
156
... More
6 pin 15/16 amp socket outlet
10
1970
197
... More
Supplying and fixing following size/ modules, GI box in recess etc as required.
-
-
-
... More
1 or 2 Module (75mm X 75mm)
2
330
165
... More
3 Module (100mm X 75mm)
5
880
176
... More
4 Module (125mm X 75mm)
5
925
185
... More
6 Module (200mm X 75mm)
6
1320
220
... More
8 Module (125mm X 125mm)
2
486
243
... More
12 Module (200mm X 150mm)
10
2750
275
... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
-
-
-
... More
1 or 2 Module
2
266
133
... More
3 Module
5
755
151
... More
4 Module
5
790
158
... More
6 Module
6
1092
182
... More
8 Module
2
422
211
... More
12 Module
6
1632
272
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB / RCCB / Isolator). 6 way (4 + 24), Double door
1
4974
4974
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 KA"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,
testing and commissioning etc. as required.
-
-
-
... More
Single Pole
16
4096
256
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
13838
13838
... More
Providing and fixing 20 mm X 3 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
3
2850
950
... More
Providing and fixing 20 mm X 3 mm copper strip on surface or in inrecess for connections etc. as required.
10
6970
697
... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
5
775
155
... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar ( 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
5
11000
2200
... More
Providing and fixing following rating and breaking capacity and
pole MCCB with thermomagnetic release and terminal
spreaders in existing cubicle panel board including drilling holes
in cubicle panel, making connections, etc. as required.
-
-
-
... More
MCCB FP 100 Amp. 30 KA icu=ics=100% (Adjustable)
1
7723
7723
... More
On Load Change over switch 100 Amp front operated
1
7100
7100
... More
Aluminium Bus Bar 200 Amp set of 4 strips
2
1600
800
... More
Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Busbar, Indicating Lamp, CT Set etc as required.
2
10000
5000
... More
Supplying & laying PVC insulated and PVC Sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling of trench etc. as required.
-
-
-
... More
35 sq. mm x 3.5 core Armoured
30
11070
369
... More
Supplying & fixing of following electrical items.
-
-
-
... More
Angle / Button Holder
2
70
35
... More
Triple pole and neutral 63 Amp
2
3700
1850
... More
Fan sheet
8
200
25
... More
Phenolic laminated Round sheet 4" dia
60
600
10
... More
Supply, installation, testing and commissioning of (15-18 watt) LED recess/surface mounted Down lighters having CRCA /Aluminum Body, minimum lumens 100 Im/w, the luminaire housing should be crca/aluminium and the luminair optics shall have a high efficency with transmittance, average life of 50000 hrs operating temperature -10 ºC to + 45 ºC incl. making of necessary connections. (Samples are to be approved by Engineer Incharge before execuation after submission of data sheet on OEM Letter Pad or third party to be nominated by department if required.
10
13000
1300
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
6
2214
369
... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
12
480
40
... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit
protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than
the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by
Engineer in charge.
20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm
20
12000
600
... More
Supplying & fixing of following size and type of fans suitable for operating on 240 Volt, AC, 50HZ supply inculding of making complete connections as required.
-
-
-
... More
Ceiling fan 1200 mm sweep alongwith rod upto 1'-6" long
(Cromption High Speed, Havells Velocity, Orient PSPO or Equivalent)
6
16200
2700
... More
Exhaust fan 300 mm size (Metalic) heavy duty (Crompton Trans air or Equivalent)
2
5200
2600
... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4
KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.
LED Street Light fixture with Minimum lumen output 11225 lm
4
30000
7500
Evaluation Notes How It Works ?