Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Oct 2024
Closing Date25 Oct 2024
Tender Amount₹ 17,45,008
Costs
EMD
₹ 34,900Document Cost
₹ 800Tender Fee
Refer Documents
Summary
Construction Of Indoor Sports Comlex/stadium At Gurez B.w.o Electrical Work
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_261170_1Bid Award Id
ViewTender No
NIT NO.57/2024/25 dt/18/10/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor Make) & shall be approved before execution of work.
-
-
-
2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
70
500
35000
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/ISub main From Main Panel to Distribution Boards.
70
350
24500
2x4 sq.mm+ 1x4 sq.mm (P+N+E) for Inverter Sub main in One run from Main Panel to Distribution Boards.
70
334
23380
2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Inverter Circuit in One run from switch boards to Distribution Boards.
200
275
55000
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating ,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of Single Pole (SP) in existing MCB . DB Complete with connections.(Havells/L&T/Siemens/Legrand/Schneider Make)
38
256
9728
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (Havells/L&T/Siemens/Legrand/Schneider Make)
-
-
-
32-40Amp.
8
1250
10000
63Amp.
4
1850
7400
Supplying and Fixing of MCB 8-Way(6+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 451V/240V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required.(Havells/L&T/Siemens/Legrand/ /Schneider Make)
2
8000
16000
Supplying and Fixing of MCB 12-Way horizontal typed , sheet steel, Double Door Distribution Board, SPN 240V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required.(Havells/L&T/Siemens/Legrand /Schneider Make)
2
2400
4800
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM
Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
1
10500
10500
Supply/Installation/Testing and Commissioning of 18 W+ LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen effiency of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havells/Wipro/Jaguar Make.
58
1650
95700
Supply/Installation/Testing and Commissioning of upto 450 mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Polycab/LUKER USA Make.
16
1900
30400
Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.
8
3500
28000
Supply/Installation/Testing and Commissioning of 150Watt Next generation, energy saving, environment friendly & robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system effiency upto 150 Im/W of Item Code SAUCERGENXADVPROHBP150WLED857PWBBORL Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The Job Includes Supply/Fixing of Suspension Kit for hanging of light.The job further includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havells/Wipro/Jaguar Make.
12
17500
210000
Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall / floor mounted) compartmentalized , 415 volts TPN MCCB Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices
(1) Normal Incoming
160 Amp TPN MCCB with breaking capacity of 50 KA thermo magnetic adjustable based of Legrand
/ Siemens/ ABB /Schinder /L&T make = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set
Volt meter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1set
,Selector Switch = 1 No.
(2) Generator Incomer
100 Amp Four Pole Change over switch of Havels / Siemens/ /Schinder /L&T make = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set
Volt meter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1set ,Selector Switch = 1 No.
/ = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set
(3) Invertor /Solar Incomer
32 Amp Double Pole MCB (10 KA) of Legrand / Siemens/ /Schinder /L&T make = 3 no, 200 Amp P&N Bus bar Al Strips = 1 Set
Outgoing .
(1) 40-63 Amps DP MCB MCB (10 KA) of Legrand / Siemens/ /Schinder /L&T make = 6 No for normal lighting/Heating sub main/ Sub main invertor
The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing
1
110000
110000
Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires
2
6500
13000
Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified.
4
4500
18000
Supply/Laying/Connecting and Commissioning of 70 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench.
360
630
226800
Supply/Laying of 25/32/38mm Dia PVC Conduit of Anchor/Ravinder/Polypack/Finolex Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Tile with same Colour/Paint etc where required.
150
110
16500
Supply/Installation/Testing & Commissioning of 1-phase 15 KVA,50 Hz Oil cooled unbalanced type Voltage Stabilizer SERVO control of Approved brand COPPER wound of Chinar/AE/Cosco Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications :
Input voltage(Ph-N) ranging from 90 Volts to 240 Volts and a balanced output Voltage of 230 Volts, ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Controller and Spike Protection having 01 No. 63 Amp 2-Pole from input side & 63 Amp DP from output side Complete job.& includes CMC (reckoned from date of successful commissioning) for a period of Two years.etc
1
115000
115000
Supply/Installation/Testing and Commissioning of 3-Phase, Four Pole 100 Amp,415V Ac,50Hz offload Manual Changeover Switch side handle in enclosure Havells/L &T/ABB Make including S/F/Crimping of Suitable Size of thimbles for connections as per site requirement for bypassing 20 KVA AVR. as approved.
1
12000
12000
Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make.
1
800
800
Part-B (Solar-Inverter)
-
-
-
Supply/Installation/Testing/Commissioning of BIS Certified 05KVA/120V Solar Inverter Pro PCU inbuilt MPPT Technology(with 2-Year Warranty), 10 No. of 200Ah,12V Tubular battery (with 05 Years Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc Havells/Luminious/EXIDE/ AMRON Make.The job includes CMC (reckoned from date of successful commissioning) for a period of Two years.
1
210000
210000
Supply/Installation/Testing/Commissioning of BIS Certified Mono PERC Half Cut Panel of 550Wp (with 12-Years Product Warranty & 25 Years Performance Warranty) of Havells/Luminious/EXIDE Make.The job includes CMC (reckoned from date of successful commissioning) for a period of Two years.
9
30500
274500
Supply/Installation/Testing/Commissioning of Earthing with SPDs(P+N+E) for both Input & Output for solar inverter, Earthing Copper Wire and other Miscellaneous items & the job includes CMC (reckoned from date of successful commissioning) for a period of Two years.etc
1
9000
9000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements