Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Jan 2025
Closing Date3 Feb 2025
Tender Amount₹ 26,47,903
Costs
EMD
₹ 53,000Document Cost
₹ 1,100Tender Fee
Refer Documents
Summary
Restoration Upgradation Of Defunct Electric System ( Cabling , Pannels, Fixtures , Wirirng Etc.) Pf Sanat Ghar Buuilding Bemina Srinagar
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWDJK_270664_1Tender No
NIT NO.168/2024/25 dt/18/01/2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring for inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.( excluding the cost of conduit) sample to be approved by EIC.
450
137
61650
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5-10 A modular socket outlet and 2 nos. 5-10 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make/equivalent make as directed by engineer incharge. )sample to be approved by EIC.
40
680
27200
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make/equivalent make as directed by engineer incharge. )
40
477
19080
... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, "C" curve including connections, painting etc. as required.
5
727
3635
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Polycab/ Fenolex/ Anchor make.), single core cable in surface/ recessed (excluding the cost of conduit) medium class PVC conduit as required.
-
-
-
... More
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
350
95
33250
... More
(e ) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
60
472
28320
... More
(f ) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
60
710
42600
... More
Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, complete
-
-
-
... More
(a) 25mm
650
145
94250
... More
(b) 32mm
250
184
46000
... More
Supply installation testing and commissioning of 12 W-15W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Wipro/Trilux/ L T make ( sample to be approved before installation)
50
1250
62500
... More
Supply installation testing and commissioning of 7 W-9W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Wipro/Trilux / L T make ( sample to be approved before installation)
50
850
42500
... More
S/F testing and comm. Of surface mounted LED Batten 20 watt-22 watt +- 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. Philips/ Trulux /Wipro/ LT make. sample to be approved before installation.
12
750
9000
... More
S/F testing and comm. Of MCB's ( 10K) of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ L&T ./ABB/equivalent make as directed by engineer incharge.
-
-
-
... More
a) 6-32 Amp SP MCB
50
245
12250
... More
b) 40-63amp DP MCB
30
1250
37500
... More
c) 40-63amp TPN MCB
50
2350
117500
... More
Engaging of highly skilled labour / Electrician for Dismentling of old damaged materials like wires in scraps, fixtures switches-sockets complete as directed by the engineer at site and stacking and handing over to concerned department including carrying out repairing works etc.
15
1050
15750
... More
Supply installation testing and comm. Of 200-250mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
31
1750
54250
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA Striker /Havells Oyster matalic/Crompton aura make ( sample to be approved before installation) 3 star
10
2200
22000
... More
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make/equivalent make as directed by engineer incharge. )
10
320
3200
... More
Supplying and fixing following way,Triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/ABB make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
-
-
-
... More
6 way, Double door ( 18+4)
2
4974
9948
... More
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block.
20
48
960
... More
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board/ floor panels by 10 SWG copper wire with 1/2" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
1
10500
10500
... More
Supply installation testing and comm. of flood light/ street light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Trulux /Wipro make.
15
8500
127500
... More
Supply installation testing and comm. of 100 Amp TPN MCCB 25 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make.
7
9500
66500
... More
Supply installation testing and comm. of Digital A/V meters set for panels
40
3500
140000
... More
Supply installation testing and comm. of LED Panel indicators
40
150
6000
... More
S/L , testing and commissioning of PVC XLPE insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
-
-
-
... More
a) 16 sq.mm 4 core
450
410
184500
... More
b) 35 sq. mm 3.5 core
350
495
173250
... More
c)70 sq.mm 3.5 core
159
915
145485
... More
d)95 sq.mm 3.5 core
185
1143
211455
... More
e)120 sq.mm 3.5 core
185
1350
249750
... More
Supply and fabrication of angle iron stand of Structural steel work in built up sections, and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
650
106
68900
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) including bends, Tees, cross members and allied accessories with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
-
-
-
... More
200 mm width X 50 mm depth X 1.6 mm thickness
185
720
133200
... More
450 mm width X 50 mm depth X 2.0 mm thickness
90
1300
117000
... More
600 mm width X 50 mm depth X 2.0 mm thickness
90
1700
153000
Evaluation Notes How It Works ?