Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date20 Nov 2024
Closing Soon29 Nov 2024
Tender Amount₹ 21,93,000 
Notes
Download

Costs

Summary

Upgradation Of District Social Welfare Office Jammu By Way Of Repair/renovation Of Residential School For Specially Abled Students At Roop Nagar Jammu Electrical Part.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

59

369

21771

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

20

40

800

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

45

676

30420

... More
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.

-

-

-

... More
2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire

375

233

87375

... More
2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire

900

275

247500

... More
2 x 4 sq. mm + 1 x 4 sq. mm earth wire

750

334

250500

... More
2 x 6 sq. mm + 1 x 6 sqmm earth wire

20

439

8780

... More
4 x 6 sq. mm + 2 x 6 sq. mm earth wire

100

570

57000

... More
4 x 10 sq. mm + 2 x 6 sq. mm earth wire

80

1005

80400

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.

-

-

-

... More
1 x 1.5 sq. mm

600

45

27000

... More
Supplying and fixing of ceiling fan of followingsweep with 2.25 mfd condenser and 1'-6" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire.

-

-

-

... More
1200 mm sweep (Crompton High Speed, Havells Velocity, Orient PSPO or Equivalent)

57

2700

153900

... More
Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type) on wall with necessary connection as required.

5

2900

14500

... More
Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.

-

-

-

... More
300mm/12" sweep exhust fan

11

1900

20900

... More
Supplying and fixing of fan hook (U hook) on celiling with 2 nos. of anchor fastener on both ends with necessary bolts and nuts and mansonry work as required.

4

250

1000

... More
Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required.

-

-

-

... More
4 Way (4+12), (Double door )

2

4091

8182

... More
6 way ( 4+ 18), (Double door)

6

4974

29844

... More
8 way ( 4+24), (Double door)

1

5967

5967

... More
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.

2

9000

18000

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

20

244

4880

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

10

70

700

... More
Supply, installation, testing & commissioning of maintenance free copper earthing system with 2 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.

2

11500

23000

... More
Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.

20

1162

23240

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

20

155

3100

... More
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make).

-

-

-

... More
25 mm

450

145

65250

... More
Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire.

-

-

-

... More
IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm

117

600

70200

... More
Decorative LED Hanging Light for officer table as apporved by site Engineer

1

3500

3500

... More
2x2 Recess Led Panel 595mmX595mm 36 W+/- 1W, Recess mounted fixture with HET PMMA diffuser  with minimum system lumen efficacy of 110 lm/W and minimum 3900 lumens with CRCA housing with APFC constant Current driver for proper driving of LEDs and P.F.0.95 with THD10% ,CRI 80.The LED with life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700K- 6500K with CRI of minimum 80. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 3kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.

57

2200

125400

... More
Providing & fixing of following accessories.

-

-

-

... More
15/16 Amp 3 pin top

16

95

1520

... More
Insulation Tape (ISI brand)

2

10

20

... More
Celing Rose

86

65

5590

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.

-

-

-

... More
1 or 2 Module (75mm x 75mm)

1

298

298

... More
3 Module (100mm x 75mm)

1

327

327

... More
4 Module (125mm x 75mm)

1

343

343

... More
6 Module (200mm x 75mm)

1

402

402

... More
8 Module (125mm x125mm)

1

454

454

... More
12 Module ( 200mm x 150mm)

1

547

547

... More
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required.

-

-

-

... More
5/6 amps switch

30

103

3090

... More
15/16 amp switch

30

156

4680

... More
3 pin 5/6 amp socket outlet

10

122

1220

... More
6 pin 15/16 socket outlet

10

197

1970

... More
Supplying and fixing of following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole upto 32 amp.

135

256

34560

... More
Single pole 40 amp.

16

325

5200

... More
Single pole and neutral 32 amp. (Modular)

2

650

1300

... More
SPN 63 Amp

1

850

850

... More
TPN 40 Amp

8

1750

14000

... More
TPN 63 Amp

8

1850

14800

... More
Supplying and fixing single pole blanking plate in the existing MCB DB Complete etc. as required

20

13

260

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar ( 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.

24

2200

52800

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)

-

-

-

... More
100 Amp, 30 KA, FP MCCB ICU = 100% ICS

1

7723

7723

... More
125 Amp, 36 KA, FP MCCB ICU = 100% ICS

1

8209

8209

... More
250 Amp, 36 KA, FP MCCB ICU = 100% ICS

1

17510

17510

... More
ON Load Change Over Switch FP 250 amp. (Front operated)

1

28500

28500

... More
Aluminium Bus Bar 400 Amp set of 4 strips

2

1200

2400

... More
Aluminium Bus Bar 500 Amp set of 4 strips

2

1300

2600

... More
Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.

1

5000

5000

... More
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)

-

-

-

... More
70 sq. mm 3.5 core

30

640

19200

... More
185 sq. mm 3.5 core

30

1466

43980

... More
Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten).

-

-

-

... More
Casing Caping 1"

50

65

3250

... More
Supplying and fixing of Phenolic Laminated Sheet 9" x 11" including cutting the space for switches/socket etc.

2

100

200

... More
Supplying and fixing of Phenolic Laminated Sheet 9" x 6" including cutting the space for switches/socket etc.

2

80

160

... More
Supplying and fixing of Phenolic Laminated Sheet 4" x 4" including cutting the space for switches/socket etc.

2

40

80

... More
Supplying and fixing of Phenolic Laminated Sheet 11" x 13" including cutting the space for switches/socket etc.

2

120

240

... More
Supplying and fixing of Phenolic Laminated Sheet 6" x 3" including cutting the space for switches/socket etc.

2

65

130

... More
Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Cold type of minimum capacity following Specification as detailed below. 1. Should be of inverter type 2. Cooling capacity (in Tr): 1.5 3. BEE Star rating: 5 4. Maximum local temperature: 52 C 5. Rated cooling capacity (BTU/hr.): 19000 or above 6. Condensing coil: 100% Copper with grooved copper tubes 7. Electrical input, 220 V ± 30/50Hz/Single Phase 8. Noise level (indoor unit): = close to 35 dB 9. Compressor type: rotary or any other suitable technology 10. Refrigerant type: R-32 11. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent 12. Compressor Warranty: 10 years 13. PCB Warranty: 5 year 14. Total System Warranty: 1 year 15. Minimum noise level of the indoor unit should be around 28 dB (A)

-

-

-

... More
16. Should have air filtering mechanism for removing dust 17. Supplier has to include brochure of the quoted model Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.

3

47000

141000

... More
Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.

-

-

-

... More
4 KVA

3

9000

27000

... More
Supplying & fixing of M.S Wall Stand duly powder coated for outdoor unit of Split AC

3

950

2850

... More
Supplying & fixing of drain pipe for indoor unit 1"

20

120

2400

... More
Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC

15

1150

17250

... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. LED Street Light fixture with Minimum lumen output 11225 lm

12

7500

90000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.