Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Solid Waste Management
Eprocure
Opening Date16 Dec 2024
Closing Soon2 Jan 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Establishment Of Pasteurized Compost Making Unit (capacity 35t) At Verinag

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
UNDERDECK INSULATION:Providing and fixing thermal insulation with XPS material density of minimum 38-40 kg/m3, 50 mm thick .as per Technical Specifications complete as per directions of Engineer-in-charge. The edge profiles shall be straight-edged, shiplap, or tongue-and-groove for reduced thermal bridging and surface finish shall be smooth or embossed for better adhesion with other materials like adhesives or plaster

90

-

-

... More
Insulation (For Walls, Doors and Ceiling) for Tunnel:SITC of Prefabricated EPG puff wall panel and ceiling Panel (50mm thickness) and minimum density of 40 kg/m3 as per tender technical specification enclosed. fixed to walls, ceiling with screws, rawl plugs and washers and held in position etc. complete as per directions of Engineer-in-charge. :

250

-

-

... More
Providing and laying of dia 100 mm PVC pipes class C with fittings and acessories along with reducer type spigots (at every 400 mm) as pe technical specifications all along the length of the pipe– 12 Nos of length 75 ft for circulation of air inside the bunkers with spigots.

1

-

-

... More
Providing and laying of dia 160 mm PVC pipes class C – 4 Nos of length 20 ft for circulation of air inside the bunkers & Tunnel.

1

-

-

... More
GSS Ducting:‐ Supplying fabrication installation testing and commissioning of GI. Sheet metal ducting. Zinc coated. Complete with all Standard Accessories, G.I.. Hardware, Self Adhesive elastomeric foam gasket, Support etc as per SMACNA specification. 22 gauge , Sheet Thickness - 0.8 mm-1.00 mm

20

-

-

... More
Air-outlets and Dampers: Aluminium/volume control dampers as required.

2

-

-

... More
Air-outlets and Dampers: Louvers but without volume control dampers complete as required.

2

-

-

... More
Providing thermal insulation to supply air ducting with 50mm.thickness Glass wool Insulation with 0.6 mm Al Cladding.

20

-

-

... More
HOT WATER GENERATOR: Providing, Installation, Testing and Commissioning Steam generator of capacity (200 kg/hr) - 01 no. (Vertical type, Oil fired Boiler, pressure 3 to 6 bar, water pump 1 hp, fully automatic, water level controller, dual pressure controller,Temperture monitoring system, safety valve and float valve). The Job also including the (GI Pipes with epoxy painting) , Control valves ( for automatic operation) and Nozzles of suitable pressure rating along with all allied fittings for the Distribution of the Steam inside the Bulk Chamber / Tunnel. The job includes for MS Day tank of 200 litre capacity of 3mm thickness complete with pipes,valves & level indicators. The Job also includes Chimney with ladder, base plate, nuts & bolts, template for foundation etc painted with heat resistant alumunium paint with Flue gas ducting wa;l dupporting, 6 metre Height with diamter of 150 mm and thickness of 5/6 mm and 3 metres connecting ducts. Complete job including hardwares, electric fitting required for the successful completion of the job. The complete job includes cost of material, labour, tools and tackles reqd for completion of job and taxes. Any other electrical item required for the completion of job shall be in the scope of the firm/ contractor

1

-

-

... More
Supply, Installation and testing and commissioning of Water Softner including all pipes and fittings for the Water Tank.

1

-

-

... More
ELECTRICAL WORKS:Electrical fitting by way of Providing and fitting of 06 no. 20 watt LED light, 04 nos. 20W Tubelight, 1 no. ceiling fans, 1 no. exhaust fan 18”dia and 100 W LED outdoor/flood lights-8 nos. Job also includes Providing of laying of main service line 16 sq. mm from main pole to MCB box inside the shed,32A MCB. It also includes providing of 2.5 sq.mm pvc wire, Modular switches and sheet, Modular 5A Socket, Modular 15A socket, conduit,, MCB and other allied items The job includes material cost , tools and tackles, labour cost and taxes. Any other electrical item required for the completion of job shall be in the scope of the firm/ contractor

1

-

-

... More
Control panel comprising of Bus bar MCCBs, contactors, relays, single phase preventers, earth fault relays, changeover switches, for Air Blower units and pumps including cables etc. with following specifications. Incomer: 1. Incomer : MCCB 150 Ampere 4 pole 36KA 2. Aluminum 4 Pole Bus Bar –02 set 3. Digital Voltmeter with Selector Switch 4. Digital Ammeter with Selector Switch & CT’s 5. Phase Indicator Set and Single Phase preventer. Outgoing feeders: a) Feeder with MCCB and other protective devices suitable for 20 HP Blowers b) Feeder with MCCB and other protective devices suitable for 05 HP Blower c) Feeder with MCCB and other protective devices suitable for 1.5 HP / 2 HP Pumps (03 Nos). d) Feeder for Cabin Lighting and other loads.

1

-

-

... More
WATER TANKS AND ASSOCIATED PUMPS: Providing and fitting of triple layer HDPE storage tank with cover and suitable locking arrangement and making necessary holes for inlet and outlet pipes including overflow pipes having capacity of 10,000 ltr (5000 litrs x 2 Nos) with foundation of Suitable size as per requirement, fittings, pipes required and base support and interconnecting pipes between the Tanks along with valves. The job further includes p/f of 1 hp mono block self primer water pump along with 3/4 inch GI B Class piping (50 metres), PVC hose pipes & Sprinklers complete accessories and fittings including electrical fittings. The complete job includes cost of material, labour, tools and tackles and taxes thereof.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.