Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Nov 2024
Closing Soon2 Dec 2024
Tender Amount₹ 29,34,681 
Notes
Download

Costs

Summary

Improvement / Up-gradation Of Existing Electric Network By Way Replacing Of Overhead Lt Power Cables, Installation Of Main Control Panel , Strengthening Of Sub-main/ Circuit Wires With Allied Accessories At Ddc Office Building Budgam.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2 x 16 Sq.mm + 1 x 16 Sq.mm

290

730

211700

... More
2 x 10 Sq.mm + 1 x 10 Sq.mm

290

540

156600

... More
2 x 6 Sq.mm + 1 x 6 Sq.mm

290

270

78300

... More
2 x 4 Sq.mm + 1 x 4 Sq.mm

550

190

104500

... More
3 X 2.5 Sq.mm

950

120

114000

... More
3 X 1.5 Sq.mm

550

80

44000

... More
Supply and fixing of 4-6 Sq.mm Copper thimbles to be crimped rolling of colour coded tape

48

28

1344

... More
Supply and fixing of 10-16 Sq.mm Copper thimbles to be crimped rolling of colour coded tape

40

35

1400

... More
Supply and fixing of 50-95 Sq.mm Aluminium thimbles thimbles to be crimped rolling of colour coded tape

12

70

840

... More
Supply and fixing of 95-185 Sq.mm Aluminium thimbles thimbles to be crimped rolling of colour coded tape

12

90

1080

... More
Supply,Laying,Testing & Commissioning of 185 Sq.mm XLPE /PVC insulated LT Power cables of standard make dully isi mraked .The cable is laid partially through walls with necessay cliffs saddles and partially laid underground incl digging and refilling ,Incl cost of p/f of Al thimbles on both sides dully crimped with hydraulic crimping tool and making of necessary connections to be laid as per site requirement and as directed at site

100

1850

185000

... More
Supply,Laying,Testing & Commissioning of 50 Sq.mm XLPE /PVC insulated LT Power cables of standard make dully isi mraked.The cable is laid partially through walls with necessay cliffs saddles and partially laid underground incl digging and refilling ,Incl cost of p/f of Al thimbles on both sides dully crimped with hydraulic crimping tool and making of necessary connectionsto be laid as per site requirement and as directed at site

35

750

26250

... More
Proving of earthlings with Chemical Earthing with G I to G I electrode, 50 mm dia and 2 Mts long Pipe incl cost of boring and refilling of same with chemicals with man hole at the top with 19 x 3 mm G I Strip from Earthings terminal seperately to D G Set Body ,& neutral, and Servo Stabilizer Body and Neutral etc..The job includes providing and fixing of main hole PVC chamber

3

8500

25500

... More
Supply , Installation ,testing and commissioning of 100 Amp DP MCB (10 KA) of Legrend /L&T /ABB / Simens make ,isi marked incl making of necessary connections.

4

3450

13800

... More
Supply , Installation ,testing and commissioning of 125 Amp DP MCB (10 KA) of Legrend /L&T /ABB / Simens make ,isi marked incl making of necessary connections.

4

4250

17000

... More
Supply , Installation ,testing and commissioning of 63 Amp DP MCB (10 KA) of Legrend /L&T /ABB / Simens make ,isi marked incl making of necessary connections.

10

1850

18500

... More
Supply , Installation ,testing and commissioning of 40 Amp DP MCB (10 KA) of Legrend /L&T /ABB / Simens make ,isi marked incl making of necessary connections.

8

1250

10000

... More
Supply , Installation ,testing and commissioning of 100 Amps FP Change over Switch Havels /Standard /HPL Make incl making of necessary connections.

1

7500

7500

... More
Supplying and fixing of 6-10-16 -20- Amps S Pole rating 240/415 volts MCB of Legrend /L&T /ABB /Simens make dully isi marked complete with connections.

58

260

15080

... More
Supply ,installation ,testing and commissioning of Double door MCB Box fabricated out of sheet steel dully company coated paint ofstandard make dully isi marked incl fixing on walls complete job of Legrend /L&T /ABB /Simens make

24

190

4560

... More
Supplying and fixing of 2 mm thick medium class PVC conduit/double lock channel along with accessories in surface/recess including cutting the wall and making good the same (pop/wall putty) in case of recessed conduit as required 19/25 mm

360

86

30960

... More
Supply and fixing of 19/25 mm decorative wood channel

65

125

8125

... More
Point wiring for switch controlled primary light points with 3 x 1.5 Sq.mm PVC Insulated multistrandedcopper wire of Polycab/HPL/Paramount make (To be approved before laying) in recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of approved quality with moulded cover plate of Anti bacteria Series of Legrend /L&T /ABB Make and including cost of circuit wiring in 3 x 2.5 Sq.mm ( from DB to first switch in the sub circuit) complete as per specification and as required ( Excl cost Of conduiting)

40

900

36000

... More
Point wiring for 16 Amp Socket out lets with 3x4 sq mm Sq.mm PVC Insulated multistrandedcopper wire of of Polycab /Anchor /Finolex /Havels/Salzar make (To be approved before laying) in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of Anti bacteria Series of Legrend /L&T /ABB Make with inter connection complete as per specifications and as required.( Excl cost of conduiting )

12

1750

21000

... More
Point wiring for 6 Amp Socket out lets with 3x2.5 sq mm Sq.mm PVC Insulated multistrandedcopper wire of Polycab /Anchor /Finolex /Havels/Salzar make(To be approved before laying)s in recessed or surface conducting system incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp 5 pin combined shuttered socket out let along with 6 Amp control Switch of Anti bacteria Series of Legrend /L&T /ABB Make with moulded cover plate and inter connections and including cost of loop earthing with 2.5 sq mm PVC Insulated multistranded copper wire for circuit wiring( from DB to first switch in the sub circuit) complete as per specification and as required volt grade flexible stranded copper conductor wires complete as per specifications and as required.( Excl cost of conduiting )

12

1450

17400

... More
Supply and fixing of 12-15 Watts LED surface /recess (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing should made of pressure die-cast aluminium. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. Approved make Philips / Lighting techology / Trilux /Wipro make (to be approved before installation)

30

1450

43500

... More
Supply and fixing of 18 Watts LED surface /recess (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing should made of pressure die-cast aluminium. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. Approved make Philips / Lighting techology / Trilux /Wipro make (to be approved before installation)

6

1750

10500

... More
Supplying and fixing following modular switch/ socket with modular plate & including connections & modular plate of required size etc. as required. Of Anti bacteria Series of Legrend /L&T /ABB Make

-

-

-

... More
5/6 A switch

6

103

618

... More
15/16 A switch

6

156

936

... More
3 pin 5/6 A socket outlet

6

122

732

... More
6 pin 15/16 A socket outlet

6

197

1182

... More
Telephone socket outlet

2

148

296

... More
Bell push

2

140

280

... More
Supply. Installation, testing and commissioning of 200-250 mm sq Shutter Type Exhaust fans of Crompton Greaves / Havel's/Usha make

1

2150

2150

... More
Supply,Installation .Testing and Commissioning of Controlling Panel ,fabricated out of heavy guage sheet steel ,dully Painted with powder coated paint ,dust protected ,including of 02 sets of Al. Bus bar ,earth terminal fitted on epoxy cleats,volt meter & Ammeter of AE make with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits.The switchs are connected with bus bars inside panel.The switch are adjustable type made of of Legrend /L&T /ABB /Simens /Schinder (Acti -9 series ) make (1) Normal incomer 125 Amps TPN MCCB With breaking capacity of 26 KA thermo magnetic adjustable based of Legrend /Simens /L&T / ABB make with extended rotory handle and phase spreaders on i/p and o/p side = 1 no (1B) 200 Amp TPN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT's of ratio 630 A/5A ,CL 1.0 ,15VA . (1D) 3 No's (3 No's) phase indication lamps and 3 No.'s status indication lamp for ON / OFF /TRIP with Control SP MCB (2) Generator Incomer Outgoing (1) Normal outgoing for heating load 125 Amps DP MCB (10KA) of Legrend /Simens /L&T / ABB make = 3 No (2) Normal outgoing for lighting load 63 Amps DP MCB (10KA) of Legrend /Simens /L&T / ABB make = 3 No (3) invertor outgoing for lighting load 40 Amps DP MCB (10KA) of Legrend /Simens /L&T / ABB make = 6 No's The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel.

1

65000

65000

... More
Supply , Installation ,testing and commissioning of 630 Amps Aluminium Bus Bar Chambers Chambers complete Job including making of necessary connections etc or Angle iron stand whos legs are to be grouted on cement concrete including cost of civil materials if fitted fitted on ground.(to be installed as per instructionof site incharge)

1

16500

16500

... More
Providing and fixing of 200 mm width X 50 mm depth X 1.6 mm thickness cable trys made of heavy guage sheet steel.incl. welding,jointing & properly levelling etc .The Job includes sheet steel rain proof cover complete job

16

1150

18400

... More
Supply ,fabrication ,fixing of Angle iron of sizes for supporting stucture of cable trys.The job includes supply and applying of one coat of red oxide paint and two coats of Aluminium painting

80

100

8000

... More
Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 25/4Ox3mm MS flat clamp)

100

140

14000

... More
Dismentling of Existing LED Lighting fixtures / ceiling fans / Exhaust fans carefully stacking of same at safer places and then reinstallation of same after proper cleaning with cleaning agents after relaying of wires including testing and commissioning complete job.

96

88

8448

... More
Supply,Installation,Testing & Commissioning of 5 KVA Power Invertor (pure sine wave type) having generator compitability and provided & fitted with 4 No's of 12 Volts ,180 AH Tall tubular batteries of exide make and battery rack to be fabricated of Angle iron (As per approved drawing ) for resting of batteries (complete job including cost of invertor ,batteries and angle iron rack ) .The specification are envisaged thereof. 1. Capacity of power invertor : 5 KVA 2. Output waveform : Pure Sine wave 3. operating input voltage ± 10V : 100V to 280V 4. input frequency :- 40 HZ to 60 HZ 5.Protection : Short circuit trip ,overload trip , Battery low & over charging protection ,over tempt. protection ,AC Fuse trip/MCB Trip protection ,phase reverse protection 6. Display :- Tri colour LCD Display ,which shows main input voltage ,Battery voltage ,applied load in percentage ,Battery chrging /Charged ,Battery Low / over chrge ,short circuit ,overload ,over temperture. 7. Total hormonic distoration @ linear load : 3% 8. output freqency :- 50HZ ± 1HZ 9.Batter voltage & AH :- 12 Volts /180 AH Tall tubular type 10. No. of batteries per invertor :- 4 No's Complete job including terminal connections of batteries ,carriage and applicable taxes .The job further includes AMC of invertor and batteries for a period of three years reckoned from date of sucessful commission (Which includes replcement of defective items of UPS's /Batteries by fresh on during AMC period)

1

155000

155000

... More
Labour Charges for Proper dressing of wires of sizes in the attic ,including dismentling of same and relaying through pvc conduits complete job.(Excluding cost of conduits)

1

5500

5500

... More
Supply,Installation,Testing & Commissioning of Buck-Boost type 160 KVA,3-Phase,415V, , L.T,Unbalanced Servo voltage stabilizer (OUT DOOR type) .that must take a load of 200 KVA at the Following Specifications No. of Phases = 3 No Input Voltage (L-L)= 208-460 Volts Output Voltage =415 volts ±1%(Phase to phase) & 230 volts±1%(Phase to neutral) Protection =Over voltage, under voltage & Overloading with TDR & Neutral failure protection . Buck-Boost The Stabilizer shall be servo-controlled automatic ,ONAN cooled and provided with first filling of fresh filtered transformer oil having required dielectric strength .The Stabilizer shall be capable of smooth operation upto 10 % un-balanced in the load currents.The contractor /supplier has to give guarantee for any manufacturing defect with three servicing of the equipment for two year reckoned from commissioning.Inclusive of all applicapable taxes (Electrified /Automatic electric / Chinar / Alba / Casco make) The contractor has to faciltate testing of stabilizer at manufacturing site to departmental representative before despatching to site of work. The Job further includes CMC for a period of three years reckoned from date of sucessful commissioning (The comphrensive maintenance contract includes operation and maintenanace of stabilizer including replacement of damaged /burnt out accessories /equipments (what so ever reason) both mechanical as well as electrical completly by fresh one besides carrying timely servicing ) The complete inspection of Stabilizer shall be carried out by departmental representative not less than the rank of SDO at manufacturing site before assembling of stabilizer and contractor has to faciltate in all aspects the departmental representative uto manufacturing plant.

1

680000

680000

... More
Supply,Installation,,Testing & Commissioning of 400 Amps 4-Pole Bypass Changeover Switch of Havells /Eq. make ,with Angle iron stand whose legs are grouted on cement concreate block including cost of civil materials

1

41500

41500

... More
Supply ,Installation ,Testinmg and Commissioning of 5-6KVA On-Line UPS System , having LCD display with isolation transformer , 0.9 pf, 1 phase input and 1 phase output, built in OVCD, wide input voltage window, generator compatible .The job further includes providing and fixing of Amaron make 20 nos. 12V/42AH SMF-VRLA Batteries for 60 minutes back up including MS battery rack for resting of batteruies , battery link set, installation complete as per site requirements. The job includes Annual maintenance contract for a period of two years reckoned from date of sucessful commissioning with onsite replacement guarantee of  3 years UPS & Batteries of Eaton /APC Scheinder / Vertiv make

1

210000

210000

... More
Supply ,laying ,testing and commissioning of 63 Amps F.Pole Change over Switch with allied sheet steel enclosure of Havels /Standard / HPL make ,inc;luding making of necessary connections

2

7500

15000

... More
Supplying and fixing of following 8- way prewired double door MCB distribution Boards of sheet steel of standard make dully isi marked Double door on surface / recess complete with refacing of walls.

2

1850

3700



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.