Public Works Department Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Feb 2025
Closing Soon27 Feb 2025
Tender Amount₹ 41,25,875 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Group‐B (Primary point )

65

1182

76830

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit (partially laid), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Polycab /Havells / Finolex (wire)/Schneider /ABB /L&T /Honeywell (switches)/Eqt. as per IS Standard.

-

-

-

... More
Group‐B (Primary point )

115

885

101775

... More
Wiring for group controled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent Switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Polycab /Havells / Finolex (wire)/Schneider /ABB /L&T /Honeywell (switches)/Eqt. as per IS Standard.

-

-

-

... More
Group‐B

60

753

45180

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.Schneider /ABB /L&T /Honeywell/Eqt.make as per IS standard

20

40

800

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

55

477

26235

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

25

676

16900

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.Schneider /ABB /L&T /Honeywell/Eqt.make as per IS standard

105

586

61530

... More
Bed Head Panel

-

-

-

... More
SITC of Electrical Bed Head Panel complying ISO 7396-1 certification and latest international standards NFPA 99 / EN / HTM 2022 / HTI 2020 / DIN standards complete in all respects. It should have bottom railing design. a)The material should be mild steel powder coated colour / aluminium alloy having thickness of 2mm (min). b) It must have provision for Modular switch and socket with base plate and cover plate complete c) It must have provision for screw-mount / snap-fit mount d) It should be made of Thermoset Plastic providing high degree of protection against melting / catching fire on heating. 125 mm × 60 mm

30

1400

42000

... More
Supplying & fixing following modular type Switch / Socket on the existing modular plate / Bed Head Panel / Channel trunking and switch box including connection but excluding modular plate / Bed Head Panel / Channel trunking etc. as required

-

-

-

... More
3 pin 5/6 A socket outlet

90

69

6210

... More
2 way 5/6 A switch

90

64

5760

... More
3 pin 16 A socket outlet

30

197

5910

... More
2 way 16 A switch

30

156

4680

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required Polycab /Havells / Finolex/Eqt. as per IS Standard.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

100

233

23300

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

400

275

110000

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire For 16A Power Circuit Point

1150

334

384100

... More
2 X 6 sq. mm +1 X 6 sq. mm earth wire(in minimum 25mm)

350

439

153650

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire For DB Submain wire

95

1005

95475

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire For DB Submain wire

95

1365

129675

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 X 10 sq. mm (25 mm)

12

269

3228

... More
4 X 16 sq. mm (28mm)

12

309

3708

... More
Supplying and fixing following size/ modules, Gl box alongwith modular base &cover plate for modular switches in recess etc. as required

-

-

-

... More
3 Module (100 mmX75 mm)

2

327

654

... More
4 Module (125 mmX75 mm)

2

343

686

... More
12 Module (200mmX150mm)

2

547

1094

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

8

103

824

... More
15/16 A switch

8

156

1248

... More
3 pin 5/6 A socket outlet

8

122

976

... More
6 pin 15/16 A socket outlet

8

197

1576

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.Legrand / Siemens/ ABB /Schneider /L&T/Eqt. as per IS Standard.

10

727

7270

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Legrand / Siemens/ ABB /Schneider /L&T/Eqt. as per IS Standard.

30

369

11070

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

90

100

9000

50

145

7250

50

150

7500

30

190

5700

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.

10

727

7270

... More
Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required.

6

99

594

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door

5

7512

37560

... More
8 way (4 + 24), Double door

4

10165

40660

... More
12 way (4 + 36), Double door

4

12833

51332

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)

-

-

-

... More
6 way (4 + 18), Double door

4

4974

19896

... More
8 way (4 + 24), Double door

4

5967

23868

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

90

256

23040

... More
Triple pole

6

1007

6042

... More
Supplying and fixing 63 A TP rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

6

1650

9900

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

18

13

234

... More
Supplying and fixing following rating, double pole, 240 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

6

656

3936

12

902

10824

... More
Supplying and fixing following rating, four pole, 415 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

2

2400

4800

12

2700

32400

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

5

1700

8500

7

1800

12600

7

2100

14700

... More
Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required.

-

-

-

... More
For 8 way, Double door SPN MCBDB

8

832

6656

... More
For 10 way, Double door SPN MCBDB

8

810

6480

... More
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

8

1170

9360

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

8

1592

12736

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

1621

8105

... More
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

4107

20535

... More
Earthing with G.l. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

3

6855

20565

... More
Supplying and laying 6 SWG G.l. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required.

90

51

4590

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

89

144

12816

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.l. Wire in 15 mm dia G.l. pipe from earth electrode including connection with G.l. thimble excavation and re‐filling as required.

90

287

25830

... More
Rubber Mats for Electrical Control Rooms: Material: 6mm High-quality rubber (usually natural rubber or synthetic rubber blends) that meets relevant standards for electrical insulation (such as ASTM D178 or IEC 61111).

1

2711

2711

... More
SUB-HEAD-V:CABLE TRAY & RACEWAY

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
450 mm width X 50 mm depth X 2.0 mm thickness

15

1325

19875

... More
300 mm width X 50 mm depth X 1.6 mm thickness

10

963

9630

... More
150 mm width X 50 mm depth X 1.6 mm thickness

10

716

7160

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
450 mm width X 50 mm depth X 2.0 mm thickness

2

2683

5366

... More
300 mm width X 50 mm depth X 1.6 mm thickness

1

1852

1852

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

1270

1270

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

1

2156

2156

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

1383

1383

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

1

2823

2823

... More
Supply & Laying of following sizes of Power Cables Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part 1) 1988 with upto date amendments laying in the existing RCC/ HUME/ METAL pipe/Cable tray as required.(Cable tray & RCC Hume pipe & Metal Pipe Should be seperatly Paid as per tender items)

-

-

-

... More
3.5 x 95 sq.mm.

30

887

26610

... More
3.5 x 120 sq.mm.

46

1250

57500

... More
3.5 x 300 sq.mm.(Assumed From Existing Sub-Station To Proposed Building )

90

2330

209700

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required

-

-

-

... More
4C X 25 sq. mm (28mm)

6

315

1890

... More
3½ X 50 sq. mm (35mm)

4

413

1652

... More
3½ X 70 sq. mm (38mm)

4

468

1872

... More
3½ X 95 sq. mm (45mm)

2

588

1176

... More
3½ X 120 sq. mm (45mm)

2

613

1226

... More
3½ X 300 sq. mm (70mm) .(Assumed From Existing Sub-Station To Proposed Building )

2

1195

2390

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

15

247

3705

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

15

668

10020

... More
SUB-HEAD-VII: SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LIGHT FIXTURES AND FANS

-

-

-

... More
Note:-The model numbers specified below are only for references for Shape of the product requirement. The product shall supplied, must match the technical specifications. The technical data sheets shall be arranged before the material dispatch and got approved from engineer-in- charge.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Surface Mount Round Led Downlighter consuming a system wattage of 12-15W (±10%) & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Die Cast Aluminium. IP20 , Optics: PMMA/Polysterene Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard.

7

1300

9100

... More
Supply, Installation, Testing and Commissioning of Surface Mount Round Led Downlighter consuming a system wattage of 18-22W (±10%) & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Die Cast Aluminium. IP20 , Optics: PMMA/Polysterene Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard.

17

1588

26996

... More
Supply, Installation, Testing and Commissioning of 4ft Linear LED luminaire delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. The luminaire Housing shall be made of CRCA & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.

35

675

23625

... More
Supply of Bulk Head Luminare delivering an initial system lumen of 700 lumens & the luminaire shall be with system efficacy ≥ 70 lm / W. Housing: Die Cast Aluminium. IP65 , Diffuser : OPAL Polycarbonate. The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.

2

954

1908

... More
Supply, Installation, Testing and Commissioning of 2ft Linear LED luminaire delivering an initial system lumen of 903 lumens & the luminaire shall be with system efficacy ≥ 90 lm / W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (Similar to Wipro Cat No.: LL20-111-XXX-65-NE or equivalent as per approved list of make)

8

656

5248

... More
Supply, Installation, Testing and Commissioning of Recess mounted LED 2'x2' luminaire delivering an initial system lumen of 3300 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: CRCA, Rim: Engneering plastic / CRCA. Optics: polycarbonate/PMMA/Polysterene, IP20 Protection. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.

129

2500

322500

... More
Supply, Installation, Testing and Commissioning of 3W LED Unidirectional Exit Signage Light with inbuilt 2 hours battery back up .

8

3900

31200

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required..

38

2730

103740

... More
Supply, Installation, Testing and Commissioning of 300mm dia sweep PVC body, 900±10% RPM Exhaust fan with guard and mounting arrangement.

18

1776

31968

... More
Supply, installation, testing and commissioning UPS of 60 kVA/ 48kW ( Input 3Phase / output 3 Phase) Floor Mount Type, Compact & modulat design, Conforming to IEC EN 62040 (All Parts), ISO 9001 certified, True On-Line, double conversion, IGBT on the input and output with multiple digital signal processor controlled for Rectifier/ charger, Battery, 2 Level IGBT Inverter, Static Switch, with parallel redundent, compatible with 0.7 lagging to 0.7 leading PF loads without deration, power factor 0.8, THDi 3-5%, Input voltage 380-415V, Output voltage 415V, 50Hz frequency, efficiency 95%, 0-40 deg C, with inbuilt overload, short circuit, Input low voltage, output over voltage, battery over charging, battery over discharging protections, Parallel kit, 30 min battery back-up with 12 V Maintenance Free Sealed Lead Acid batteries alongwith Powder Coated M.S. Rack with unidirectional wheels for housing the Batteries alongwith all accessories including interconnecting cables, lugs, Base Frames, Battery Rack & Battery Circuit breaker complete as required. Continue Below....

1

920000

920000

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e),(f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with CONTINUED in NEXT Cell

-

-

-

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e),(f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also becarried out. (h) only outer surface area on all sides shall be measured & panel to be fabricatedonly from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. CONTINUED in NEXT Cell

-

-

-

... More
Generator Incomer •250 Ampers, 415V MCCB, microprocessor based50 KA, with short circuit earth fault & overcurrent relay, incoming from DG set, Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. Quantity = 1 Nos •400 Amp TPN Bus Bar (Aluminium IEC 60105 / Copper IEC 60028), fitted with SMC/DMC insulators, high-tensile nuts, bolts, and spring washers. Includes bending, cutting to size, and colour coding with heat shrinkable PVC sleeves. (Quantity: 1 set.) • (0-500 A) Digital Ammeter with selector switch & 500/5 A CTs = 4 sets • (0-500 V) Digital Volt meter with selector switch = 4 Sets • RYB indication lamps with MCB = 4 sets Changeover Switch 400 A CONTINUED in NEXT Cell

-

-

-

... More
MAIN PANEL Supplying, installation, testing & commissioning of AMF cum load management Panel Totally Type Tested (TTA) compartmentalized type cubicle board, made of 2 mm thick CRCA sheet steel providing with suitable size angle iron and channel supported with suitable size of base channel for floor mounted dust & vermin proof duly phosphatized & powder coated, inclusive of suitable size and length. The panel shall be suitable for incoming bus ducting and outgoing cables from top and bottom both sides, providing inter earthing and inter-connection with PVC insulated copper conductor cable, solid copper conductor of suitable sizes and lugs on both ends of each cable and making electrical mechanical interlocking in incomings and bus coupler and providing all meters with backup fuses & selector switches etc. I/O providing and fixing below noted accessories. Normal Incoming • 400 Ampers, 415V MCCB microprocessor based, 50 KA, with short circuit earth fault & overcurrent relay, Make: Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. Quantity = 1 Nos • 600 Amp TPN Bus Bar (Aluminium IEC 60105 / Copper IEC 60028), fitted with SMC/DMC insulators, high-tensile nuts, bolts, and spring washers. Includes bending, cutting to size, and colour coding with heat shrinkable PVC sleeves. (Quantity: 1 set.) • (0-400A) Digital Ammeter with selector switch & 630/5 A CTs = 4 sets • (0-500 V) Digital Volt meter with selector switch = 4 Sets • RYB indication lamps with MCB = 4 sets Generator Incomer •250 Ampers, 415V MCCB, microprocessor based50 KA, with short circuit earth fault & overcurrent relay, incoming from DG set, Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. Quantity = 1 Nos •400 Amp TPN Bus Bar (Aluminium IEC 60105 / Copper IEC 60028), fitted with SMC/DMC insulators, high-tensile nuts, bolts, and spring washers. Includes bending, cutting to size, and colour coding with heat shrinkable PVC sleeves. (Quantity: 1 set.) • (0-500 A) Digital Ammeter with selector switch & 500/5 A CTs = 4 sets • (0-500 V) Digital Volt meter with selector switch = 4 Sets • RYB indication lamps with MCB = 4 sets Approved Makes: CONTINUED in NEXT Cell

1

490000

490000

... More
Changeover Switch 400 A Outgoing Devices: (MCCBs) • 160 A, 4 Pole, MCCB , 25 kA, Overload & Short Circuit, Microprocessor Based Trip Unit Micrologic Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. Quantity: 4 nos. • 125 A, 4 Pole, MCCB , 25 kA, Overload & Short Circuit, Microprocessor Based Trip Unit Micrologic 2 Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. Quantity= 4 nos. • 100 Amps 4 pole MCCB with a breaking capacity of 25kA, thermo-magnetic adjustable, ICU=ICS=ICW. Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. Quantity: 4 nos. • 63 Amps 4 Pole MCCB with breaking capacity of 16 kA, thermo-magnetic adjustable, ICU=ICS=ICW. Make: Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. (Quantity: 4 nos.) MCBs (Miniature Circuit Breakers): • 63 Amps TPN MCB (16 kA) for lighting. Make: Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. (Quantity: 3 nos.) • 40 Amps TPN MCB (16 kA) for lighting. Make: Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. (Quantity: 3 nos.) • 32/40 Amps Double Pole MCB (10 kA). Make: Legrand / Siemens / ABB / Schneider / L&T / Havells / Equivalent to IS Standard. (Quantity: 4 nos.) • Extra Provision should be made for 1 No. 400 MCCB with 600A Aluminium Bus Testing and Approval: • The contractor shall submit test certificates for the main switchgear and detailed drawings of the panel showing clear dimensions and spacing as per IE Standards. Drawings and test certificates must be approved by the Engineer In Charge before manufacturing. Any concerns may be referred to a third party for approval. • The panel must be as per IEC 61439 TTA type from any India based test laboratory (CPRI/ERDA etc.) for protection against short circuit/ temperature rise /internal arc / degree of

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.