Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Eprocure
Opening Date5 Feb 2025
Closing Date17 Feb 2025
Tender Amount₹ 6,13,551 
Notes
Download

Costs

Summary

Supply, Installtion, Testing And Commissing Of 30 Kva Capacity 3 Phase Servo Stablizer With Allied Works Uphc Harwan

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply/Laying/Testing and Commissioning of 3.5 Core 70 mm sq. Al armored XLPE Insulated,PVC cable Havells/KEI/RR Kabel/Paramount Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (100 cm below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. (For Main Supply)

15

1275

19125

... More
Supply/Laying/Testing and Commissioning of 3.5 Core 35 mm sq. Al armored XLPE Insulated,PVC cableHavells/KEI/RR Kabel/Paramount Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench whether required of standard make as approved.The cable shall include end termination lugs with its crimping /taping. (For Generator)

55

450

24750

... More
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.

2

10500

21000

... More
Design/Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) LT feeder panel (3+1) Al. bus bar of cubical type vermin proof,Sloped Roof Double door lockable outdoor type fabricated out of 14/16 SWG MS Sheets powder coated weather proof, dust proof with IP 65 protection with 4 legs stand of 2.5 feet height/ground clearance properly grouted in Cement Concrete base b.w.o raising the concrete jacketing (01x01) ft below & Above ground level and 08 inch of dia in 1:3:4 ratio, filter with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects complete in all respects with following :- Incoming: 1) 3-Phase,4-Pole 200A MCCB,36 kA C-CURVE MCCB with extended terminals (Adjustable Thermal & Fixed Magnetic) of Havells/L&T/Legrand/Schneide rmake as approved-01 No. & RY/B indicator set. 2) 3-Phase, Four Pole 100 Amp,415V Ac,50Hz offload Manual Changeover Switch side handle in enclosure Havells/L &T/ABB Make including S/F/Crimping of Suitable Size of thimbles for connections as per site requirement for bypassing 50 KVA AVR. as approved. Outgoing: 200 Amp Suitable Al. Bus bar

1

35000

35000

... More
Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel outdoor type with slopped roof compartmentalized with D-Fast Geyser Bolts & nuts , 415 volts TPN MCCB Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming 160 Amp TPN MCCB with breaking capacity of 36 KAwith extended thimbles of Legrand/Siemens/ ABB/Havells /LK make = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set Volt meter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1set (2) Generator Incomer 100 Amp Four Pole Change over switch of Havells/Siemens/ ABB /Schinder /L&T make = 1 no 100 Amp TPN Bus bar Al Strips = 1 Set,phase indicators =1set & 100 Amp TPN Bus bar Al Strips = 1 Set Outgoing (1) 100 Amps TPN MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 02 No for X-Ray Machine (2) 63 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 03 No for Sub main Heating (3) 40 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 03 No for Sub main lighting The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing

1

110000

110000

... More
Supply/Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Wipro/H.G/Jaguar/Bajaj Make.(To be installed on existing lighting points)

45

1650

74250

... More
Supply/Laying/Connecting of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.

4

1551

6204



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.