Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Civil And Construction
Electrical Goods and Equipments
Building Construction
Electrical and Electronics
Eprocure
Opening Date13 Jan 2025
Closing Date28 Jan 2025
Tender Amount₹ 16,26,042
Costs
EMD
₹ 32,520Document Cost
₹ 800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWDJK_270185_1Tender No
NIT NO.158/2024/25 dt/11/01/2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.) SAmple to be approved by EIC.
20
670
13400
... More
Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent)
-
-
-
... More
i.3 pin 5A - 10A socket.
10
122
1220
... More
ii. indicator.
10
100
1000
... More
Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/
Finolex/KEI/RR or equivalent) incl. cost of conduit
200
275
55000
... More
Supply, installation, testing and commissioning of 12 - 15 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
(Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series.
84
1250
105000
... More
Supply, installation, testing and commissioning of 3 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of
necessary connections.
20
2250
45000
... More
Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular
plate etc. as reqd.
20
369
7380
... More
Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/
windows as per site and necessary connections. (Havells/ Philips/ Crompton).
3
1950
5850
... More
Supply, installation, testing and commissioning of 100Watt LED Flood lighting luminaries having aluminum body, minimum 100lm/w, the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature -10`C to +45`C. LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending
department. (Havells/ Philips/ Crompton/ Jaguar/Wipro).
5
5500
27500
... More
Supplying and fixing of modular blanking plates on existing modular plate and
switch box ,excluding modular plate as required.
40
40
1600
... More
Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, incl. cost of conduits(Havells/ Polycab/ Finolex/
Anchor/KEI/RR or equivalent).
-
-
-
... More
2 x 2.5 sq.mm + 1x 2.5 sq. mm earth wire
150
275
41250
... More
2 x 6 sq.mm + 1x 6 sq. mm earth wire
90
439
39510
... More
4 x 10 sq.mm + 2x 6 sq. mm earth wire
90
1005
90450
... More
Supply and installation of 32A modular plug/socket with 32A DP MCB for ACs
4
1850
7400
... More
Supply and fixing of 8 way (4 + 24) Double door surface/ recess mounting , Vertical/ Horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of
MCBs and Incomer. .
4
5967
23868
... More
Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary
connections.
72
256
18432
... More
Supply, installation, testing and commissioning of 32 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB
distribution board complete with necessary connections.
8
1250
10000
... More
Supply, installation, testing and commissioning of 63 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB
distribution board complete with necessary connections.
4
1650
6600
... More
Supply, installation, testing and commissioning of 63A TP&N rating 240/ 415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in
the MCB distribution board complete with necessary connections.
4
3144
12576
... More
Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick.
1
2000
2000
... More
Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 3 mtr. Long GI earthing electrode, 80 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical
compound.
4
10500
42000
... More
Supply, installation , testing and commissioning of 20 KVA, 3-Phase, 415V,LT, Unbalanced AVR of Essentials, KE, ALBA, Chinar, Cosco make, operating from input voltage of L-L=155-460V & L-N=90-265V, thereby producing the output voltage of 415V +_2% Phase to Phase and 230V +_2% Phase to Neutral. The AVR should have inbuilt Over voltage protection, Under voltage protection & Over loading with TDR. The stabilizer shall be servo controlled automatic, ONAN cooled and provided with first filling of fresh filtered transformer oil having required di-electric strength. The stabilizer shall be capable of smooth operation up to 10% un-balanced in the load currents complete with servo bye pass system consisting of 100A four pole manual type change over switch, 100A four pole MCCB 01 no. and required bus bar. The supplier has to give guarantee for any manufacturing defect with three servicing of the equipment for two years reckoned from successful commissioning. The job also includes
all applicable taxes, carriages, loading and unloading.
1
155000
155000
... More
Supply, installation, testing and commissioning of 2KVA (2000VA) Power Inverter (Pure Sine Wave type) having generator compatible & provided and fitted with 2 no. 12V, 180 Ah, tall tubular batteries of Exide make and PVC trolley for resting/ housing of batteries. The job also includes terminal connections of batteries, input/ output leads of required size and length,
carriage and applicable taxes.
1
65000
65000
... More
Supply, laying, connecting and commissioning of 150 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT
cable , incl. cost of required al. thimbles duly crimped. ( under ground).
100
1650
165000
... More
Supplying and laying of DWC HDPE (Double Wall Corrugated High Density Polyethylene) pipe, 200 mm dia.(OD – 200 mm & ID – 175 mm) ISI marked along with all accessories like sockets, bends, couplers, etc. with fitting and cutting, jointing, etc. (under ground), including excavation and refilling the
trench after laying the pipes.(complete job)
90
668
60120
... More
Supply and fixing of fan deep made of heavy gauge sheet in RCC slabs.
20
140
2800
... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point
(a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base
M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure. (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear
c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar ( 125).
(d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates
to be submitted) All as per pre approved by Engineer in charge.
20
2200
44000
... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)
-
-
-
... More
Normal Incoming
-
-
-
... More
250 Amp, 36 KA, FP MCCB
1
17510
17510
... More
Aluminum Bus Bar 500 Amp set of 4 strips
1
8500
8500
... More
ON Load Change Over Switch FP 160 amp. (Front operated)
1
20500
20500
... More
Aluminum Bus Bar 300 Amp set of 4 strips
1
6500
6500
... More
Digital Metering devices, comprising of Voltmeter, Ammeter, Selector
Switch, Indicating Lamp, etc.
2
5000
10000
... More
Outgoing
-
-
-
... More
63 Amp, TPN MCB 10KA
4
3144
12576
... More
63 Amp, 10 KA, DP MCB
4
1650
6600
... More
Space for 16 way MCBs
1
4000
4000
... More
Supply, installation , testing and commissioning of 3 star rating 1.5 Ton Hot and Cold Inverter type split Air Conditioners suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector internal unit with one indoor and one outdoor unit. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle iron stand fitted with nut/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrile foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC insulated copper cable and a battery operated wireless remote unit. The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of
successful commissioning. (Daikin/ Blue Star/ LG).
4
62000
248000
... More
Supply, installation , testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90-260Volt thereby producing output voltage of 230volts +_ 3%. (4 KVA)
4
8500
34000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%