Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date14 Nov 2024
Closing Soon5 Dec 2024
Tender Amount₹ 8,41,166 
Notes
Download

Costs

Summary

Construction Of Govt. Medical College For 100 Admissions At Ang. B W O Electrification Of Laboratory Block ( 2nd And 3rd Floor) At Gmc Ananatnag

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
i.4 module

10

343

3430

... More
ii. 6 module

15

402

6030

... More
iii.8 module

32

454

14528

... More
Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider/Legrand or equivalent) sample to be approved by EIC

-

-

-

... More
i.3 pin 5A - 10A socket.

40

122

4880

... More
ii. indicator.

20

100

2000

... More
iii.6 pin 15/16A socket.

46

197

9062

... More
iv. 15/16A switch.

46

156

7176

... More
v. 5A - 10A switch.

40

103

4120

... More
Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Havells/ Polycab/ Anchor/ Finolex/KEI/RR make in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl. cost of conduit

300

137

41100

... More
Supply, installation, testing and commissioning of 18 Watt LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100im/w, average life 50000 hours, Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). (commercial series)

25

1450

36250

... More
Supply, installation, testing and commissioning of (2feet x2feet)36 Watt LED recessed/mounted (square) Down lighters having aluminum body, minimum 100im/w, average life 50000 hours, Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). (commercial series)

50

3200

160000

... More
Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton/ Anchor).

5

1950

9750

... More
Supplying and fixing of modular blanking plates on existing modular plate and switch box ,excluding modular plate as required.

60

40

2400

... More
Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excl. cost of conduits(Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent).

-

-

-

... More
2 x 2.5 sq.mm + 1x 2.5 sq. mm Normal Lighting Circuit

200

137

27400

... More
2 x 6.0 sq.mm + 1x 6.0 sq. mm Lighting Sub main

100

304

30400

... More
4 x 10.0 sq.mm + 1x 6.0 sq. mm Heating Sub main

100

820

82000

... More
Supply, installation, testing and commissioning of 1200 mm sweep ceiling fans of Havells/ Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of ceiling rose, extension of Gi pipe/rod , iron clips (if required) and making of necessary connections. (3 Star)

30

2200

66000

... More
Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd.

30

369

11070

... More
Supply and fixing of 6 way (4 + 18), Double door surface/ recess mounting , vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer.

6

4974

29844

... More
Supply and fixing of 16 way , Double door surface/ recess mounting , Horizontal type, 240 V, SP&N MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer.

6

3141

18846

... More
Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.

130

256

33280

... More
Supply, installation, testing and commissioning of 32A/40A double pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.

6

1250

7500

... More
Supply, installation, testing and commissioning of 63A double pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.

6

1650

9900

... More
Supply, installation, testing and commissioning of 63A TPN MCB rating 240/415V, 10 KA “C” curve MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ Indo Asian/ Schneider).

6

2850

17100

... More
Supply and fixing of 25 mm dia. Medium class PVC conduit along with accessories in surface / recess, incl. cutting the wall and making good the same or fixed with nails/screws with rawlplugs or as required.

200

145

29000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.