Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Electrical and Electronics
Eprocure
Opening Date10 Jan 2025
Closing Date22 Jan 2025
Tender Amount₹ 4,05,349
Costs
EMD
₹ 8,110Document Cost
₹ 200Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWDJK_270068_1Tender No
NIT NO.154/2024/25 dt/08/01/2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing & Fixing of M.S Ceiling Fan Fastener to be laid in Slab where required of Standard Make.
5
120
600
... More
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor Make)
160
334
53440
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Livia) Make & shall be approved before execution of work.
7
586
4102
... More
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor Make)
120
275
33000
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Livia) Make & shall be approved before execution of work.
5
680
3400
... More
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor Make) & shall be approved before execution of work.
-
-
-
... More
2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
20
570
11400
... More
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards.
20
439
8780
... More
2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards.
100
275
27500
... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Livia) Make Make
2
18
36
... More
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider Make)
12
256
3072
... More
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB/Schneider Make)
-
-
-
... More
32Amp.
1
656
656
... More
40Amp.
1
1250
1250
... More
63Amp.
1
1850
1850
... More
Supplying and Fixing of MCB 8-Way (4+18) horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider Make)
1
5100
5100
... More
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM
Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
2
10500
21000
... More
Supply/Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Wipro/H.G/Jaguar/Bajaj Make.
32
1650
52800
... More
Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.
4
3200
12800
... More
Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/Orient Make.(5-Star)
5
2730
13650
... More
Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Havells/Polycab/Orient Make.(Min 3-Star)
5
2000
10000
... More
Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified.
1
4500
4500
... More
Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires.
1
8500
8500
... More
Supply/Laying of 25/32mm Dia PVC Conduit of Anchor/Ravinder/Polypack/Finolex Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Tile with same Colour/Paint etc.
150
120
18000
... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.Havells/ Legrand/Panasonic/Anchor/Schneider Make
5
87
435
... More
Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall / floor mounted) compartmentalized , 415 volts TPN MCCB Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices
(1) Normal Incoming
125 Amp DP MCCB with breaking capacity of 36 KAwith extended thimbles of Legrand/Siemens/ ABB/Havells /LK make = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set
Volt meter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1set Outgoing .
(1) 63 Amps DP MCB MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 02 No for normal heating sub main
(2) 40 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 02 No for Sub main lighting/invertor
(3) 32 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 02 No for Sub main invertor
The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing
1
45000
45000
... More
Supply, Laying. testing & Commissioning of 35 sq.mm 2-core Steel armoured Cable Al. Cable XLPE /PVC insulated and sheathed duly to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade Main SERVICE Line from Nearby L.T pole to Panel.
50
350
17500
Evaluation Notes How It Works ?