Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date9 Oct 2024
Closing Date18 Oct 2024
Tender Amount₹ 10,45,000
Costs
EMD
₹ 20,900Document Cost
₹ 600Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_258890_1Bid Award Id
ViewTender No
56 of 2024-2025 dated 09-10-2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
(a) Columns: - Required numbers of main columns of SHS 100x100x4mm and ht.3.0m av. long column size. Each column shall have Base MS plate of size 250 x 250mmx10mm thick with 04 Nos hole of dia 18mm for fixing of 16mm dia 300mm long foundation bolts with nuts for fixing with RCC Beam foundation & top gusset plate of size 250 x 250mm 10mm thick with 04 Nos hole of dia 16 mm dia for fixing with truss by using 10mm dia bolt and nut 100mm long. The columns will be provided along shorter span of the structure at an equal interval c/c as per drg. The columns will be painted with 01 coat of red oxide primer Make: - TATA/SAIL/RINL/JINDAL or Equivalent as per the Directions of EIC
-
-
-
... More
(b) Verandah Columns: - Required numbers of main columns of RHS size 96x48x3.2mm thick and ht 2.90 m av. long( Each column shall have bottom plate of size 250 x 250mmx10mm thick with 04 No.s hole of dia 18mm for fixing of 16mm dia 300mm long foundation bolts for fixing with RCC Beam foundation & top plate of size 250 x 250mm 10mm thick with 04 Nos hole of dia 16 mm dia for fixing with truss by using 16 mm dia bolt and nut 100mm long. The columns will be provided along shorter span of the structure at an equal interval c/c as per drg. The columns will be painted with 01 coat of red oxide primer Make :- TATA/SAIL/RINL/JINDAL or Equivalent as per the Directions of EIC
-
-
-
... More
(7) Trusses/Rafter and Purlins: Required numbers of Trusses made up of size RHS 61x122X2.9mm thick & Bracing RHS 60x40x2mm thick. The purlins made up of size RHS 80 x 40 x 2.60mm thick will be provided at spacing as per design/drawing/or as per the Directions of EIC. Each rafter/purlin shall be welded at both ends with 6.0 mm thick MS plate cleat with suitable drilled holes to enable joint with each other using suitable Nut & Bolt. The purlins and Trusses / Rafter will be painted with 01 coat of red oxide primer Make: - TATA/SAIL/RINL/JINDAL or Equivalent as per the Directions of EIC
(8) (a) Roof : - The roof shall be in slope 1:4 approximately. The roofing shall be done with Pre-coated, pre-coloured, profiled sheet 0.63 mm thickness. These profile sheets are laid over a frame work of trusses, columns and purlins fixed using self-tapping screw with bitumen washers/washers (Roofing must be fully water-proof). Make: - TATA/SAIL/RINL/JINDAL or Equivalent as per the Directions of EIC (b) Ridge. Ridge shall be provided with 600mm wide and 0.63mm thick pre-coated, pre coloured plain sheet fixed with self-tapping screws. Make :- TATA/SAIL/RINL/JINDAL or Equivalent as per the Directions of EIC
-
-
-
... More
Roof Projection. The Roof shall have minimum projection of 0.45m from the eaves wall and 0.30m from the gable walls. Purlins will also be provided on the roof at the eaves and at gable roof extension. False Ceiling: - PVC laminated colour Gypsum false ceiling panel size 595 x 595 mm x 9 mm thick with water proofing film on back side along with powder coated aluminium snap grid framework with suitable ‘T’ and ‘L’ section. The false ceiling panels are placed onto a suspended grid frame of size 600 x 600 mm made of Aluminium ‘L’ & ‘T’ sections of 0.60mm conforming to IS. The false ceiling grid is suspended from the roof framework with the help of galvanized wire of 3.0mm dia. MAKE: SAINT GOBAIN (GYPROC) or Equivalent as per the Directions of EIC.
-
-
-
... More
Windows (04 no.s -size as per requirement/drawing/design) and 02 no. Ventilators for toilets :- Aluminium profile sliding window with all fitments complete will be provided and fixed in position by the contractor as directed by EIC. The Window shutter will be of two leaves of which one shall be provided with moveable glazing of 5 mm glass and one leave will be provided with fixed fly proofing using stainless steel mesh of 1.5 mm aperture. Doors :- (05 no.s -size as per requirement/drawing/design) doors will be provided in each room/toilet and one for main entrance fixed in position by the contractor as directed by EIC. Door Shutter and Frame will be Provided with Suitable Gauge Aluminium Profile Sections.Door Shutters will be Provided with 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling for lower portion of door and Glazing-5mm thick for upper portion of doors inclusive of all fittings etc. complete.The Doors shall be Provided with built in Locking system of make Godrej/Harrison or equivalent. Two number Aluminium Tower Bolt of 200mm size from inside and one Sliding bolt 300mm long and one bolt handle 150mm size to be provided on both in and outside of each shutter. All door Shutters shall be provided with hydraulic door closers.
-
-
-
... More
Miscellaneous items
(a) Sun Shade : - Sun Shades (Arch) shall be( provided for each window) made of coloured PPGI sheet 0.63mm thick sheet width 750 mm and length to extend 150 mm on either side of windows and doors with arch. Sun shades should be fitted with M S frame and minimum half feet above the top of the windows/doors. These will be given suitable stiffening and fixing arrangements.
-
-
-
... More
(b) Blinds: - Zebra Blinds for window sizes mentioned above. Before supply of material, sample should be approved by the EIC.
-
-
-
... More
Toilet : 01 no. Attached toilet as per drawing with office room will consist of providing and fixing of all modern Sanitary and plumbing fittings and fixtures like European type Water Closet one piece( with all necesaary attachments) , Towel Ring, Pedestal type wash basin, Wash basin mixer, Superior quality looking Mirror,PVC and UPVC pipes of required Dia. for waste water and water supply respectively etc. and other necessary items as per Directions of Engineer-in-Charge. Complete job in all aspects.
-
-
-
... More
Finishes - (A.) Flooring (Office-Rooms and Verandah/corridor): - Vitrified Tile flooring , floor tiles of size 600 x 600 mm, over 20 mm thick cement screed (1:6) over 40 mm thick leveling course in PCC 1:2:4 using 20 mm graded stone aggregate over 75 mm thick PCC (1:4:8) and providing, laying & ramming in layers Sand/Cinder for remaining level difference as per the Directions of EIC. Providing and fixing of Chequerred precast cement concrete tiles in approach stairs. Make: - KAJARIA/SOMANY or Equivalent as per the Directions of EIC.
-
-
-
... More
Electrical items:
(a) 1100 V grade PVC insulated PVC Armoured cable sheathed Aluminium Stranded conductor 3.5 core size 16.00 sqmm in service connection as per requirement at Site. (b) House service bracket (hook type) complete with 3 M long GI pipe 40 mm dia med grade, MS hooks and stay rod or guy. Nos 02 . LED panel ceiling light 2’x2’ recess type, 36 W 90-230 V, 50 Hz. Nos 08, 04 no.s wall mounted fans 400 MM , 09 no. power points which include 09 no. 16 amp. modular sockets and 16amp. modular switches with board and modular plates. The modular switches and sockets compatible with Modular PVC box. as per the required installation of the points be fixed with complete fixtures including wires of1.0mm,1.50mm,2.50mm and 4.0mm dia. as per the required load and as per the directions of the Engineer-In-Charge. ,LED flood light 10W with complete accessory. Nos 03, PVC Ceiling Rose 6 AMP. Nos 08 no.s MCB 10/16 AMP with SPN, 240 V, DP in two way steel sheet with enclosure box Nos 02, Main Switch 63 AMP with SPN, DP in two way steel sheet enclosre box. Nos 01 , Exhaust Fan: - Exhaust Fan size 300 mm heavy duties with louvers. Nos 02 , 02 no. instant gyser with all necessary fittings. All the electric material will be used of Havells/Anchor or equivalent Make. Before, supply of store sample should be approved.
-
-
-
... More
Split AC 1.5 Ton with wall hanging voltage stabilizer Nos 02
Industrial MCB: - 32 Amp MCB dual pole with enclosure box. Nos 02 along with supply by using wire of 6.0MM dia. from Main supply board to MCB point.
Earthing Set with complete accessories. Set 01
Lighting Arrester System: - Prefabricated Shelter gel earthing electrode with fitted accessories. Set 01, Earthing Material: Earthing material for one set shall be provided. NOTE:- a)The whole structure include Architectural drawings, vetted structural drawings by IIT/NIT/DIQC etc. by taking in consideration the specification mention above before start of the work.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements