Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Nov 2024
Closing Soon6 Dec 2024
Tender Amount₹ 3,77,999
Costs
EMD
₹ 7,560Document Cost
₹ 200Tender Fee
Refer Documents
Summary
Construction Of School Building At Gms Pinglana B.w.o Electrification
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_264707_1Tender No
NIT NO.90/2024/25 dt/14/11/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit ( excluding cost of conduit)
150
189
28350
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( ABB Tvisha/Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.)
6
486
2916
Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit,( excluding cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
380
130
49400
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5-10 A modular socket outlet and 2 nos. 5-10 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( ABB Tvisha/Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.)
12
590
7080
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
12
401
4812
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/ equivalent as directed by engineer incharge.), single core cable in surface/ recessed medium class PVC conduit( Including cost of conduit) as required.
-
-
-
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
150
220
33000
( d )2 X 10 sq. mm + 1 X 6 sq. mm earth wire ( Lighting submain/ three phase points)
40
510
20400
Supplying and fixing of following sizes of medium class PVC conduit/ duct ( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete
-
-
-
25mm
150
120
18000
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
12
40
480
Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.)
12
85
1020
Sub Head-2 - Fixtures and Fittings
-
-
-
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block. And 15 watt LED Lamp, Philips/ Havel's /Wipro make / sample to be approved before installation..
55
295
16225
S/F testing and comm. Of surface mounted LED Batten 20 watt-22 watt +- 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. Philips/Trulux /Wipro make. sample to be approved before installation.
20
450
9000
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA /Havells /Crompton make, sample to be approved before installation.. (3 Star)
15
2250
33750
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tivsha/schneider Livia /Havell Coral make.
15
320
4800
Supply installation testing and comm. Of 250mm -300mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
3
1850
5550
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way (4 + 24), Double door
2
5968
11936
S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABB ./equivalent make as directed by engineer incharge.
-
-
-
a) 6-32 Amp SP MCB
20
256
5120
b) 40-63amp DP MCB
4
1250
5000
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by8- 10 SWG G.I wire with 1/2" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
1
10500
10500
Supply/Laying ( Partly overhead/ partly underground) , testing and commissioning of PVC XLPE insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
-
-
-
b)25 sq.mm 2 core
35
286
10010
Supply installation testing and comm. Of control pannel outdoor type duly manufactured from (CPRI approved panel manufacturers) sheet steel 16SWG powder coated phosphatised having angle iron stand/ wall mounted fitted with following accessories to be grouted in the cement concrete, complete job (As per approved Design)
-
-
-
a) 200 amp 2 strip bus 2 No.
-
-
-
b) A/V meters set/indicators
-
-
-
c) space for 6 way MCB's
-
-
-
d) 100 amp DP MCCB 25K Legrand/ Shinider/ L&T make. 1 NO.
1
17500
17500
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%