Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Eprocure
Opening Date20 Jun 2024
Closing Date28 Jun 2024
Tender Amount₹ 15,29,350 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for 6Amp Plug with(P+N+E) 3 x 2.5 sq.mm FRLS PVC ,Polycab/Havells/Finolex/eqt make as approved by site engineer) Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit along with 1 x 2.5 sq.mm FRLS,Polycab/Havells/Finolex/eqt make as approved by site engineer) PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. with ,2No.6Amp .Modular switch(Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), 2, 2NO. Modular 6 Amp. 5-PIN Socket ,6-8 Module Modular gride plate, cover and suitable GI box etc (Excld. G.I Box laid earlier )as required (wire shall be approved before execution of wok by SITE In-charge Engineer strictly , connections etc. as required.) complete excluding cost of Conduits

65

84500

1300

... More
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. (wire shall be approved before execution of wok by SITE In-charge Engineer strictly .

250

36500

146

... More
2X 10sq. MM+ 1 X 10 sq. MM (Phase +N+E) Power point Sub main in One runFrom Main Panel to .Distribution boards(Polycab/Havells/Finolex/eqt make )

135

64800

480

... More
2 X 6SQ.MM + 1 X 6. SQ.MM [Phase +N+E) For Lighting/Inverter Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/eqt make)

135

36450

270

... More
2 X 4SQ.MM + 1 X 4. SQ.MM [Phase +N+E) For AC, Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/eqt make)

135

25650

190

... More
Supplying and fixing of 32Amp Rating ,240v, *C* Curve Miniature Circuit Breaker suitable for inductive load of following poles in existing DB . Complete with connections ,testing and commissioning etc as required Legrand /Havells or L&T /Schneider/ABB

18

16200

900

... More
SINGLE POLE (6-32Amp) Legrand /Havells or L&T /Schneider/ABB

50

16000

320

... More
Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve Residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.

-

-

-

... More
40Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens

4

6400

1600

... More
63Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens

8

17600

2200

... More
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way, Double door

4

22800

5700

... More
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job

1

12000

12000

... More
Supply installation testing and commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havel's or Wipro or Jaguar or Surya or Veto or Panasonic or H.G or LUKEER make

112

134400

1200

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/ LUKER USA

35

73500

2100

... More
Supply,Installation,Testing and Commissioning 320 Cu.m/Hr. AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. Compt 225-250mm Shutter Typed

10

19000

1900

... More
Description of work/items Supply, Installation .Testing and Commissioning of Main Controlling Panel ,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel. The switch are adjustable type made of L&T / ABB / Legrand / Siemens make and change over switch should be of havells / L&T make (1) Normal income : 100 Amps TPN MCCB With adequate breaking capacity = 1 No 200 Amps TPN Al. Bus Bar Set = 1 set Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator set (3) Inverter Incomer 100-125Amps DP MCB = 1 No 200 Amps Al. Bus Bar Set = 1 set Outgoing : (1 ) Normal outgoing for heating /Lighting etc load . 40-63 A DP MCBs=8= 8 No's as per site requirement.

1

110000

110000

... More
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required

100

3200

32

... More
Supply, laying, Connecting and Commissioning of 70sq mm 3.5 core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havel’s /with required size of thimbles dully crimped with hydraulic crimping tool including p/ fixing of saddles /clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench

60

66000

1100

... More
Supply, installation, testing& Commissioning of Bulk Head Fittings of Havel's RUGBY Model HAVEL'S BULK HEAD Fittings with 12watt LED Bulb of Philips or Havel’s /wipro make sample to be approved before installation

10

9500

950

... More
Supply, Laying, testing and commissioning of 25 mm dia. High class PVC conduit Heavy Duty, Unbreakable conduits to be laid in RCC Slab and downs in walls including cutting the wall and making good the same with 1:6 mix cement plaster in case of recessed conduit as required etc including cost of accessories like bends and ‘heavy Gauge Sheet Steel Deep Junction boxes of approved make .(Before laying of conduit the same to be approved by site Engineer) . Preferred make: Ravindera /Anchor/Alba/Polycab make.

1100

159500

145

... More
Supply, Laying, testing and commissioning of 32 mm dia. High class PVC conduit Heavy Duty Unbreakable conduits to be laid in RCC Slab as sub-main pipes and downs in walls including cutting the wall and making good the same with 1:6 mix cement plaster in case of recessed conduit as required etc including cost of accessories like bends and ‘heavy Gauge Sheet Steel Deep Junction boxes of approved make .(Before laying of conduit the same to be approved by site Engineer) . Preferred make: Ravindera /Anchor/Alba/Polycab make.

250

41250

165

... More
Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires

1

8000

8000

... More
Supply installation testing and commissioning of Sine Wave Inverter Capacity 10KVA, Rated Power 8400 W,Supports Four battery,24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Inverter should run heavy loads like AC, Geyser, Photocopiers, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes ,MCB for protection from Input mains,Bypass switch for supplying output directly from grid in case of Home UPS fault.Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status, etc.Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep-discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70%.Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF).praffered make Luminous/ Microtek/Exide.the job also includes 2 No. trollies for housing 4 No battries and inverter.

1

60000

60000

... More
Supplying, Installation, Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified

6

30000

5000

... More
Providing and Laying of shock proof rubber mats of 2mm*1mm*12mm thick insize of standard make

1

1200

1200

... More
Supply ,installation ,testing , &commissioning of 20 KVA 3 -Phase SERVO controlled VOLTAGE Stabilizer of Approved brand with following SPECIFICATIONS : (1). INPUT VOLTAGE: 156 Volt -450 Volts P-P (90V-260V N-P) (2). OUT PUT VOLTAGE : 400Volts+ 1%(230VAC) (3).Winding Material Insulation : 99.97% PURE COPPER WOUND FIBER GLASS (4). IN DOOR TYPE (5). COOLING :OIL 1S 335 (6).MICRO CONTROLLED TRUE RMS Based LCD display (7). Protections are Over Load COPPER wound of /Chinar / Electric Field /Alba /AE /Cosco etc ISI/1SO certified for smooth functioning/ constant voltage supply having Technical Specifications : Input voltage= 90-260 volts & output voltage=220 volts+ - 2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL ,High cut/Low Cut /Time delay / Over Cut through Micro Control and Spike Protection including ,Carriages ,installation charges , testing & taxes complete job

1

210000

210000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.