Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Dec 2024
Closing Date26 Dec 2024
Tender Amount₹ 2,48,228 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for Lighting circuit/ inverter circuit/6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed ( Excluding the cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

90

210

18900

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /Simens/schneider Zencelo /Crabtree athena make.) Sample to be approved by EIC.

5

590

2950

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

2

401

802

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/ equivalent as directed by engineer incharge.), single core cable in surface/ recessed medium class PVC conduit as required.( Excluding the cost of conduit)

-

-

-

... More
(f) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire

30

588

17640

... More
Supplying and fixing of following sizes of medium class PVC conduit/ channel( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete

-

-

-

180

125

22500

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

5

40

200

... More
Supply installation testing and commissioning of 15 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux /Wipro/ Eq. standard make as directed by the engineer incharge.

5

1250

6250

... More
S/F testing and comm. Of 20 - 22 Watt + 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.( commercial series)The LED with Useful life of 50000 Hrs at L70, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux/Wipro make / sample to be approved before installation..

20

650

13000

... More
S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ L&T ./equivalent make as directed by engineer incharge.

-

-

-

... More
a) 6-32 Amp SP MCB

18

256

4608

... More
b) 40-63amp DP MCB

2

1250

2500

... More
Supply installation testing and comm. Of 200-250mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.

1

1750

1750

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA /Havells /Crompton/equivalent make as directed by engineer incharge. 3 star

3

2200

6600

... More
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma urban/SSK NV/ equivalent make as directed by engineer incharge.

3

320

960

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( Indo Asian/ legrand/ Shinider/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
8 way, Double door ( 24+4)

1

5500

5500

... More
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block.

4

48

192

... More
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.

1

10000

10000

... More
Supply installation testing and comm. of flood light 50 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell ( JETA QUANTO PLUS MONO 50 W) /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.

1

3500

3500

... More
Supply, laying ( partly uderground/partly overhead) , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.

-

-

-

... More
b) 25 sq.mm 2 core

30

320

9600

... More
Supply installation testing and comm. Of control pannel outdoor type duly manufactured from (CPRI approved panel manufacturers) sheet steel 16SWG powder coated phosphatised having angle iron stand/ wall mounted fitted with following accessories to be grouted in the cement concrete, complete job (As per approved Design)

-

-

-

... More
a) 200 amp 2 strip bus 1 No.

-

-

-

... More
b) A/V meters set/indicators

-

-

-

... More
c) space for 6 way MCB's

-

-

-

... More
d) 100 amp DP MCCB 25K Legrand/ Shinider/ L&T make. 1 NO.

1

16500

16500

... More
Supply installation testing and commissioning of , rating 1.5 Ton inverter type split Air Conditioning system suitable for operation on AC supply single phase 220 V . The indoor unit fitted on wall by employing suitable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning.( Voltas/LG/Toshiba/Equivalent standard make)

1

50000

50000

... More
Supply, Installation, testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90-260 Volts thereby producing output voltage of 230 volts +/- 3 % ( Vguard/ Livgaurd/LG make)

1

7500

7500

... More
Supply installation tesyting and commsiioning of 32 A Modular plug/Socket with 32 A DP MCB for AC.( Legrand/SSK/Heager make)

1

850

850



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.