Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Healthcare and Medicine
Eprocure
Opening Date29 Nov 2024
Closing Soon9 Dec 2024
Tender Amount₹ 1,11,81,000
Costs
EMD
₹ 2,24,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_266359_1Tender No
MHDJ/e-NIT 154 of 2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://jkpwdrb.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
WALLANDCEILINGPANELINSTALLATION
Labour, material installation on site ,etc
1
-
-
ANTI-STATIC VINYLFLOORINGWITHCONDUCTING.
1) Antistatic Vinyl Flooring provides high protection against static charges making it the ideal choice for control rooms, laboratories information technology centers, semi conductor and electronics industries. Conductive performance is permanent and does not depend on air humidity or temperature conditions. 2) Seamless anti static conductive flooring with the thickness=1mm, with perfectly curved flashing covings, all joints are welded as per the colours & patterns. 3) The tiles are laid on the smooth sub-floor, done with a suitable self-leveling compound. 4) These material is conductive enough to dissipate the static electricity; without engendering personnel from the static electric shocks. 5) Shades of the antistatic vinyl flooring will always according with the client choice & as well as to see with the ground purpose.
470
-
-
ANTISTATICVINYLFLOORINGINSTALLATION
Antistatic flooring/labour/route, etc. Antistatic Vinyl flooring provides high protection against static charges making the ideal choice for control rooms, laboratories, information technology centers, semiconductor and electronics industries. Conductive performance is permanent and does not depend on air humidity or temperature conditions.
1
-
-
ALUMINIUMCOVING
1) Aluminum or PVC Dimensions 65 mm radius x 4000 mm MaterialsAluminium6063backingangle.PVCfacingFixingBackinganglefixedwith screws and coving clips into place Sealing Coving can be sealed at either edge with proprietary sealant. 2) Coving provides a way to eliminate 90 degree angles within the clean room environment .Supplied in 2 parts, the coving provided a rounded ,flush and easy to clean corner. Welded aluminium internal and external corners available.
123
-
-
VINYLCOVING
1) Vinyl coving Dimensions 65 mm radius x 4000 mm Materials STEEL6063 backing angle facing Fixing Backing angle fixed with screws and coving clips into place Sealing Coving can be sealed at either edge with proprietary sealant. 2) Coving provides a way to eliminate 90degree angles within the clean room environment. Supplied in 2 parts, the coving provides a rounded, flush and easy to clean corner. Welded aluminum internal and external corner is available.
83
-
-
CEILING SUSPENDED AHU CUM LAMINAR DUCTLESS AIR FLOW SYSTEM (CEILING AHU): PPCS-5TR.
Aluminum composite panel double skin acoustic panel body with aluminium profile and thermal break aluminum body of air handling unit to maintain the sound level to 60db which as per to NABH Guideline. The Ductless Air Handling Unit has following Features: 1) AHU Capacity - 5 TR as per the site requirement. 2) Has fresh air damper in the unit to get desired level of fresh air and to maintain positive pressure. 3) 20 air cycle per hour to keep room air more sterile and less load on air conditioning. 4) 5TR outdoor unit is given for air conditioner to get desired temperature 21 +/- 3 degree cooling in room. 5) 1500 CFM to get minimum 20 to 30 air cycle/hours to minimize biological burden and suffocation. 6) Has climate controlsystemtogetdesiredtemperatureinroomwhenoutsidetemperatureis low. 7) U.V. light do not allow fungus to grow in cooling coils in PPCS to ensure sterile air, Air particle count will not be more than class IV (1000-10000 ppm) in any corner of the room. Level of pre filters 5 and 10 microns each. HEPA FILTER of 0.3 micron. Necessary dampers for fresh air than supply chamber. DX cooling coils as per the cooling requirement of the room (18-21 degree). Based upon the room volume to support 20 to 30 air changes the necessary CFM of the AHU. It has dehumidifier circuits with necessary reverse valve and all other standard accessories for mounting theAHU.
1
-
-
AHUACCESSORIES (COPPERPIPING,ACCESSORIES,GRILLS AND DAMPERS INSTALLATION)
1) Supply and erection of the hard drawn copper piping controlcablingbetweenIDU&ODUwiththenitrilerubberinstallationasperthe standards. 2) Supply and erections of the service valves ,thermostatic expansion valves, charging of the refrigerants, drierwith the shut off balls valves etc. 3) Supply and fixing of the extruded aluminium grills including necessary accessories
1
-
-
CEILINGSUSPENDEDAHUCUMLAMINARAIRFLOW INSTALLATION
Labour, installation, time material, etc
1
-
-
LEDPERIPHERALLIGHT
Infallceiling2'X1'withlightIntensity50000Lux
12
-
-
SURGEON'S CONTROL PANEL
The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. The room Surgeon’s control panel should be modifiable with changing technology & equipment in operating environments. Control Pane lwill be user friendly & ease of operating & maintaining purpose. The panel should be “Membrane” type; configured t o incorporate all theservicesthatoperationroomstaffrequired.Thefasciashouldbemadewith superior quality UV resistance membrane with sterilization feature. The Panel should contain 6 or 9 service tiles as below: 1.TimeDayClock.2.TimeElapseDayClock.3.GeneralLightingSystem. 4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller. 7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clock shaving high brightness characters. Temperature indicator shouldindicatetheroomtemperaturewhichshouldbeconnectedtothelocalpressure switches of Air-Conditioning System. Indicators should be digital type & clocks having high brightness characters, not less than30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. System inside the theatre. The medical gas alarm should indicate High, Normal & Low gas Pressureforeachgasservicepresentintheoperatingsystem&shouldhaveanaudible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures. A hand free set Telephone System should be incorporated in the panel with memorytype card. The control panel should be designed for front- access only. All internal wires should be marked with plastic Ferrule type cable markers for ease of identification.
1
-
-
SS Pass Box:- SS 304 pass box having double door with interlock, Solid door with electrical interlocking, Window with tempered glass, UV lamp for sterilization.
Storage Unit Providing and fixing Storage unit of size 1800 X 1200 X 250mm having three
Shelves made of SS 304 grade, 5mm thick, Heat strengthens anti-microbial coating glass shutters.
Writing Board flush mounted with sterile jointing systems, 1.50 MM thick white laminate board, bended to a 02 MM steel sheet for the additional rigidity.
Modular stainless surgical scrub station or sink specially designed for the use in Operation Theater. It should be easy and conveniently foot operated & sensors based for hand free operation. It should be designed for the use of minimum two surgeons simultaneously. Job also includes dismantling of existing sanitary fittings, plugging of all the leakages and providing/laying of scrub station with latest facilities with all fittings, accessories and complete new civil works.
1
-
-
Provision for Audio Video conferencing system with professional 65” LED screen along with all the allied works for executing complete setup of live display of Surgeries/Procedures..
1
-
-
Modular Operation Theater LED Lights having 02 No of Lights each having minimum intensity of 160000 Lux, Depth illumination of minimum 10 cm, suitable spot diameter especially required for precision surgeries, having both manual and remote controlled facility and operating on 220 V/50 Hz AC.
1
-
-
X-RAY VIEW BOX CONCEALED
X-Ray view box is the necessary equipment in hospitals, medical institutes, and nursing homes. This single film X-ray view box is excellent in functioning and ensures optimal viewing quality due to the LED-based viewing. 1)Body: Powder coated mscabinet with metal frame. 2) Sheet: Acrylicsheet.3)Power: 12v,50-60hz. 4)Bulb: Highglossy LED bulbs. 5)Parts: Heavy duty switch and socket used. 6) Safety: Shock proof mechanism. 7) Holding: Plastics clips for x-ray film holding. 8)Handling: Light weight & portable. 9) Dimmer: Dimmer to adjust the brightness of screen.
1
-
-
PRESSURERELEASEDAMPER
All operation rooms should be supplied with multi bladed damper specifically designed to control room air pressures and protection the Doors should be provided within the modular panel. Each stabilizer comprises of a matching slip over rear flange coated in white color and exterior grille. The pressure dampers will contain four grade 304 SS Blades which pivot upon sealed for life bearing assemblies. It should have CE compliance under Class 1 Medical devices directive.
1
-
-
A) HERMATICALLY SEALED AUTOMATIC SLIDING DOOR.
Hermatically sealed Automatic sliding door in OT. The Door shall be designed to fit flush into the wall panel systems. Door shall have. fabricated panel systems on both side. doors shall be fabricated from the PPGI sheets standard 30mm-50mm panel shall have frame width of 50mm & shutter width of 45 mm.
The following accessories shall be the part of the door:
1.Shutter thickness 45mm
2. Stainless steel d type of handles on pull side.
3.Standard type door cloure.
4. View panel along with self adh-tape and the silicon sealent.
5.Single side key operated locking arrangement.
6.automatic door bottom sealed
7.Stainless steel kick plates.
8.Flush mounted with sterile joining systems.
9.It’s a 1.50 mm thick white laminate board
10. Bended to a 2mm steel sheet for the additional rigidity.
The job includes providing and fitting of 01 No internal Hermatically sealed single leaf door to be fitted inside the OT.
1
-
-
OZONE GENERATOR (SOLUTION FOR FUMIGATION)
1) Magical air disinfection without any chemicals. 2) Ozone generator kills all types of bacteria ,fungus ,virus, molds. Functions: 1) Formaldehyde treatment after house fitment Peculiar smell removing, bleaching, decolorizing of restroom. 2) Peculiar smell elimination for cabinet, refrigerator , lampblack, rubbish. 3) Poisonous gas decomposing such as toluene, ethanol, carbon monoxide, sulfur dioxide. 4) Deodorization of chifforobe, shoes cabinet. 5) With ozone water have a bath to possess to bleach and the effect such as cosmetology and health protection.
1
-
-
Upgradation of Surgical OT No-7 size 22’4’’X18.6’’X9’.10’ (Say 22’5’’X18.5’’X10’’) at GMCH Jammu PPGIWALLPANEL
Pre-fabricated PPGI on both sides Puff panel with 50 mm thickness wall panels. PPGI Sheet of 0.8mm thick Panel filled with hard puff inside so became soundproof & with anti bacterial & antifungal properties Low heat transmission with GI profile for joining two panels with filling of all joints and cavities with medical grade silicon epoxy filler
830
-
-
PPGIFALLCEILING
Pre-fabricatedPPGIonbothsidesPuffpanelwith50mmthicknessfall ceiling panels. PPGI Sheet of 0.8mm thick Panel filled with hard puff inside so became soundproof & with anti bacterial & antifungal properties Low heat transmission with GI profile for joining two panels with filling of all joints and cavities with medical grade silicon epoxy filler.
400
-
-
WALLANDCEILINGPANELACCESSORIES (PPGI)
Supply and fixing of the accessories for the panel installation supply of ancillaries like l-angle, c flashing, screw, t-section support with supporting like thread rod etc. upto half meter.
1
-
-
WALLANDCEILINGPANELINSTALLATION
Labour, material installation onsite, etc
1
-
-
ANTI-STATIC VINYLFLOORINGWITHCONDUCTING.
1) Antistatic Vinyl Flooring provides high protection against static charges making it the ideal choice for control rooms, laboratories, information technology centers, semiconductor and electronics industries. Conductive performance is permanent and does not depend on air humidity or temperature conditions. 2) Seamless antistatic conductive flooring with the thickness=1mm, with perfectly curved flashing covings, all joints are welded as per the colours & patterns. 3) The tiles are laid on the smooth sub-floor, done with a suitable self-leveling compound. 4) These materiall is conductive enough to dissipate the static electricity; without engendering personne lfrom the static electric shocks. 5) Shades of the antistatic vinyl flooring will always according with the client choice & as well as to see with the ground purpose.
470
-
-
ANTISTATICVINYLFLOORINGINSTALLATION
Antistatic flooring/labour/route, etc. Antistatic Vinyl flooring provides high protection against static charges making it the ideal choice for control rooms, laboratories, information technology centers, semiconductor and electronics industries. Conductive performance is permanent and does not depend on air humidity or temperature conditions.
1
-
-
ALUMINIUMCOVING
1) Aluminum or PVC Dimensions 65 mm radius x 4000 mm MaterialsAluminium6063backingangle.PVCfacingFixingBackinganglefixedwith screws and coving clips into place Sealing Coving can be sealedat either edge with proprietary sealant. 2) Coving provides a way toeliminate90degreeangleswithintheclean room environment. Supplied in 2 parts, the coving provides arounded, flush and easy to clean corner. Welded aluminium internal and external corners available.
123
-
-
VINYLCOVING
1) Vinyl coving Dimensions 65 mm radius x 4000 mm Materials STEEL6063 backing angle facing Fixing Backing angle fixed with screws and coving clips into place Sealing Coving can be sealed at either edge with proprietary sealant. 2) Coving provides a way to eliminate 90degree angles within the clean room environment. Supplied in 2 parts, the coving provides arounded, flush and easy to clean corner. Welded aluminium internal and external corners available.
83
-
-
CEILINGSUSPENDEDAHUCUMLAMINAR DUCTLESS AIRFLOWSYSTEM (CEILINGAHU):PPCS-5TR.
Aluminum composite panel double skin acoustic panel body with aluminium profile and thermal break aluminum body of ductless air handling unit to maintain the sound level to 60db which as per to NABHGuideline. Air Handling Unit has following Features: 1) AHU Capacity - 5 TR as per the site requirement. 2) Has fresh air damper in the unit to get desired level of fresh air and to maintain positive pressure. 3) 20 air cycle per hour to keep room air more sterile and less load on air conditioning. 4) 5TR outdoor unit is given for air conditioner to get desired temperature 21 +/- 3 degree cooling in room. 5) 1500 CFM to get minimum 20 to 30 air cycle/hours to minimize biological burden and suffocation. 6) Has climate controlsystemtogetdesiredtemperatureinroomwhenoutsidetemperatureis low. 7) U.V. light do not allow fungus to grow in cooling coils in PPCS to ensure sterile air, Air particle count will not be more than class IV (1000-10000 ppm) in any corner of the room. Level of pre filters 5 and 10 microns each. HEPA FILTER of 0.3 micron. Necessary dampers for fresh air than supply chamber. DX cooling coils as perthe cooling requirement of the room (18-21 degree). Based upon the room volume to support 20 to 30 air changes the necessary CFM of the AHU. It has dehumidifier circuits with necessary reverse valve and all other standard accessories for mounting the AHU.
1
-
-
AHU ACCESSORIES (COPPERPIPING,ACCESSORIES,GRILLS AND DAMPERS INSTALLATION)
1) Supply and erection of the hard drawn copper piping control cabling between IDU&ODU with the nitrile rubber installation as per the standards. 2) Supply and erections of the service valves, thermostatic expansion valves, charging of the refrigerants, drier with the shut off balls valves etc. 3) Supply and fixing of the extruded aluminium grills including necessary accessories.
1
-
-
CEILING SUSPENDED AHU CUM LAMINAR AIR FLOW INSTALLATION
Labour ,installation ,time material ,etc.
1
-
-
LEDPERIPHERALLIGHT
In fall ceiling 2'X1 'with light Intensity 50000 Lux
12
-
-
SURGEON'S CONTROL PANEL
The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. The room Surgeon’s control panel should be modifiable with changing technology & equipment in operating environments. Control Panel will be user friendly & ease of operating & maintaining purpose. The panel should be “Membrane” type; configured t o incorporate all the services that operation room staff required .The fascia should be made with superior quality UV resistance membrane with sterilization feature. The Panel should contain 6 or 9 service tiles as below: 1.Time Day Clock.2.Time Elapse Day Clock .3.General Lighting System. 4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller. 7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time da y clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clocks having high brightness characters. Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digital type & clocks having high brightness characters, not less than30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. System inside the theatre. The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures. A hand free set Telephone System should be incorporated in the panel with memory type card. The control panel should be designed for front- access only. All internal wires should be marked with plastic Ferrule type cable markers for ease of identification
1
-
-
SS Pass Box:- SS 304 pass box having double door with interlock, Solid door with electrical interlocking, Window with tempered glass, UV lamp for sterilization.
Storage Unit Providing and fixing Storage unit of size 1800 X 1200 X 250mm having three Shelves made of SS 304 grade, 5mm thick, Heat strengthens anti-microbial coating glass shutters. Writing Board flush mounted with sterile jointing systems, 1.50 MM thick white laminate board, bended to a 02 MM steel sheet for the additional rigidity. Modular stainless surgical scrub station or sink specially designed for the use in Operation Theater. It should be easy and conveniently foot operated & sensors based for hand free operation. It should be designed for the use of minimum two surgeons simultaneously. Job also includes dismantling of existing sanitary fittings and providing/laying of scrub station with latest facilities with all fittings, accessories and civil works
1
-
-
Provision for Audio Video conferencing system with professional 65” LED screen along with allied works for executing complete setup of live display of Surgeries/Procedures.
1
-
-
Modular Operation Theater LED Lights having 02 No of Lights each having minimum intensity of 160000 Lux, Depth illumination of minimum 10 cm, suitable spot diameter especially required for precision surgeries, having both manual and remote controlled facility and operating on 220 V/50 Hz AC.
1
-
-
X-RAY VIEW BOX CONCEALED
X-Ray view box is the necessary equipment in hospitals, medical institutes, and nursing homes. This single film X-ray view box is excellent in functioning and ensures optimal viewing quality due to the LED –based viewing. 1) Body: Powder coated ms cabinet with metal frame. 2) Sheet: Acrylic sheet.3) Power: 12v,50-60hz. 4) Bulb: High glossy LED bulbs. 5) Parts: Heavy duty switch and socket used. 6) Safety: Shock proof mechanism. 7) Holding: Plastics clips for x-ray film holding. 8) Handling: Light weight & portable. 9) Dimmer: Dimmer to adjust the brightness of screen.
1
-
-
PRESSURE RELEASE DAMPER
All operation rooms should be supplied with multi bladed damper specifically designed to control room air pressures and protection the Doors should be provided within the modular panel. Each stabilizer comprises of a matching slip over rear flange coated in white color and exterior grille. The pressure dampers will contain four grade 304 SS Blades which pivot upon sealed for life bearing assemblies. It should have CE compliance under Class 1 Medical devices directive.
1
-
-
1) HERMATICALLY SEALED AUTOMATIC SLIDING DOOR. Hermatically sealed clean room door in OT. The Doors shall be designed to fit flush into the wall panel systems. Doors shall have fabricated panel systems on both sides. Doors shall be fabricated from the PPGI sheets standard 30mm-50mm panel shall have frame width of 50mm & shutter width of 45 mm.
The following accessories shall be the part of the door:
1.Shutter thickness 45mm
2. Stainless steel d type of handles on pull side.
3.Standard type door closure.
4. View panel along with self adh-tape and the silicon sealent.
5.Single side key operated locking arrangement.
6.automatic door bottom sealed
7.Stainless steel kick plates.
8.Flush mounted with sterile joining systems.
9.It’s a 1.50 mm thick white laminate board
10. Bended to a 2mm steel sheet for the additional rigidity.
The job also includes Providing and Fitting of 01 No internal Hermatically sealed single leaf manual door having same specifications as above
1
-
-
OZONE GENERATOR (SOLUTION FOR FUMIGATION)
1) Magical air disinfection without any chemicals. 2) Ozone generator kills all types of bacteria ,fungus, virus, molds. Functions: 1) Formaldehyde treatment after house fitment Peculiar smell removing, bleaching, decolorizing of restroom. 2) Peculiar smell elimination for cabinet, refrigeratory, lampblack, rubbish. 3) Poisonous gas decomposing such as toluene, ethanol, carbon monoxide, sulfur dioxide. 4) Deodorization of chifforobe, shoes cabinet. 5) With ozone water have a bath to possess to bleach and the effect such as cosmetology and health protection.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%