Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date30 Jan 2025
Closing Soon10 Feb 2025
Tender Amount₹ 7,29,723
Costs
EMD
₹ 15,595Document Cost
₹ 200Tender Fee
Refer Documents
Summary
Up Gradation Renovation Of Guest House Of Regional Institute Of Health And Family Welfare (rih And Fw) At Dobiwan Baramulla (strengthening Of Newly Taken Over School Buildings By Health Department And Upgradation Of Existing Health Institutions.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWDJK_271356_1Tender No
NIT NO.179/2024/25 dt/29/01/2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Schneider /Havells/ Legrand/Anchor roma plus/Make & shall be approved before execution of work.
11
586
6446
... More
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor Make) (including cost of conduit)
150
275
41250
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Schneider /Havells/ Legrand/Anchor roma plus/Make & shall be approved before execution of work.
10
680
6800
... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Schneider /Havells/ Legrand/Anchor roma plus Make
20
18
360
... More
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor Make) including cost of Conduits with other accessories like bends etc complete to be laid in wall/ceiling(Slab) & shall be approved before execution of work.
-
-
-
... More
2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
30
500
15000
... More
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting Sub main From Main Panel to Distribution Boards.
30
350
10500
... More
2x4 sq.mm+ 1x4 sq.mm (P+N+E) for Inverter Sub main From Main Panel to Distribution Boards.
30
280
8400
... More
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for AC Sub main From Main Panel to AC Box.
130
280
36400
... More
2x2.5 Sqmm + 1x2.5 Sqmm (P+N+E) for Lighting/Inverter Circuit from DB to switch Board
200
275
55000
... More
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/Schneider Make)
22
256
5632
... More
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Schneider Make)
-
-
-
... More
40 Amp.
2
1250
2500
... More
63 Amp.
2
1850
3700
... More
Supplying and Fixing of MCB 4-Way(4+12) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider Make)
2
4091
8182
... More
Supply/Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Trulux Make.
37
1650
61050
... More
Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.
3
3250
9750
... More
Desgin/Supply/ installation/testing and commissioning of CPRI (IS/IEC:61439) Approved panel Wall / floor mounted) compartmentalized , 415 volts TPN MCCB Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices
(1) Normal Incoming
125 Amp TPN MCCB with breaking capacity of 35 KA thermo magnetic adjustable based of Legrand
/ Siemens/ ABB /Schinder /L&T make = 1 no 250 Amp P&N Bus bar Al Strips = 1 Set
Volt meter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1set
,Selector Switch = 1 No.
100 Amp Four Pole Change-over to bypass the AVR
Outgoing .
(1) 63 Amps Double Pole MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 2 No for Heating Sub main
(2) 40 Amps Double Pole MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 4 No for normal lighting and AC's
(3) 32 Amps Double Pole MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 4 No Spare. The Panel manufacturing unit should be CPRI Registered (IS/IEC:61439) and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) which is to be approved by Engineer Incharge before manufacturing.
1
90000
90000
... More
Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB including connection etc USHA/Havells/Orient/Polycab Make.(Min 1-Star)
4
2000
8000
... More
Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/Orient Make.(3 Star)
7
2200
15400
... More
Supply/Laying/Connecting and Commissioning of 50 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Anchor Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
30
630
18900
... More
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM
Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
1
10500
10500
... More
Supply Installation Testing & Commissioning of 3 Star rating 1.5 TON inverter type split Air Conditioning system suntable for operation on AC supply single phase 220 V The indoor unit fitted on wall by employing suntable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. ‹ Mitsubishi/Toshiba/O-General make) including cost of 4KVA Digital Auto control VOLTAGE Stabilizer for ACs of Approved brand for smooth functioning/ constant voltage supply having etc Input voltage= 90-220 volts & output voltage=220 volt & stand Copper piping ete & all other allied accessories. installation charges.GST, income tax, Carnage ete Complete job The job includes CMC (reckoned from date of successful commissioning) for a period of Two years.
2
85000
170000
... More
Supply & fixing of Modular AC box with 32 AMP Single pole MCB of Havells/Legrand/Schneider/L&T make
2
1650
3300
... More
Supply and fixing of wooden channel/ casing made from Kashmiri budloowood having 2.6"-3" width suitable for carrying out wiring for different circuits.
80
250
20000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%