Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Civil And Construction
Construction Material
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Soon22 Nov 2024
Tender Amount₹ 3,86,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1 x 1.5 sq. mm

4800

45

216000

... More
3 x 1.5 sq. mm

3200

95

304000

... More
3 x 2.5 sq. mm

1050

137

143850

... More
3 x 4 sq. mm

14500

206

2987000

... More
6 x 6 sq. mm

320

598

191360

... More
4 x 10 sq. mm + 2 x 6 sq. mm earth wire

720

777

559440

... More
4 x 16 sq. mm + 2 x 6 sq. mm earth wire

720

1137

818640

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25 mm

10500

145

1522500

... More
40 mm

1800

228

410400

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

1107

103

114021

... More
3 pin 5/6 A socket outlet

977

122

119194

... More
2 pin socket outlet 5 Amp.

150

100

15000

... More
15/16 A switch

525

156

81900

... More
6 pin 15/16 A socket outlet

525

197

103425

... More
Bell push

40

140

5600

... More
SITC of Electrical Bed Head Panel complying ISO 7396-1 certification and latest international standards NFPA 99 / EN / HTM 2022 / HTI 2020 / DIN standards complete in all respects. It should have bottom railing design. a)The material should be mild steel powder coated colour / aluminium alloy having thickness of 2mm (min). b) It must have provision for Modular switch and socket with base plate and cover plate complete c) It must have provision for screw-mount / snap-fit mount d) It should be made of Thermoset Plastic providing high degree of protection against melting / catching fire on heating. 125 mm × 60 mm

100

1400

140000

... More
Supplying & fixing following modular type Switch / Socket on the existing modular plate / Bed Head Panel / Channel trunking and switch box including connection but excluding modular plate / Bed Head Panel / Channel trunking etc. as required

-

-

-

... More
3 pin 5/6 A socket outlet

75

122

9150

... More
2 way 5/6 A switch

75

103

7725

... More
15/16 A switch

75

156

11700

... More
6 pin 15/16 A socket outlet

75

197

14775

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

210

40

8400

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required

30

586

17580

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

30

676

20280

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C"curve including connections, painting etc. as required.

150

727

109050

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

40

133

5320

... More
3 Module

205

151

30955

... More
4 Module

10

158

1580

... More
6 Module

350

182

63700

... More
8 Module

160

211

33760

... More
12 Module

12

272

3264

... More
18 Module

5

352

1760

... More
Supplying and fixing following size/ modules, GI box in recess etc as required.

-

-

-

... More
1 or 2 Module (75mm X 75mm)

40

165

6600

... More
3 Module (100mm X 75mm)

205

176

36080

... More
4 Module (125mm X 75mm)

10

185

1850

... More
6 Module (200mm X 75mm)

350

220

77000

... More
8 Module (125mm X 125mm)

160

243

38880

... More
12 Module (200mm X 150mm)

12

275

3300

... More
18 Module

5

317

1585

... More
Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.

-

-

-

... More
4 way (Double door)

8

1510

12080

... More
12 way (Double door)

11

2315

25465

... More
16 way (Double door)

6

3141

18846

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB /Isolator)

-

-

-

... More
12 way (4 +36), (Double door)

38

7950

302100

... More
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole 6/10/16/32 Amp

1010

256

258560

... More
Single pole and neutral 32 Amp

50

599

29950

... More
SPN 40

150

750

112500

... More
Triple pole and neutral 40 Amp

76

1750

133000

... More
Triple pole and neutral 63 Amp

76

1850

140600

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
25 A

15

2028

30420

... More
40 A

15

2642

39630

... More
63 A

15

2722

40830

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm

240

600

144000

... More
Supply Installation testing and commissioning of 2x2 Recess Led Panel 595mmX595mm 36 W+/- 1W, Recess mounted fixture with HET PMMA diffuser  with minimum system lumen efficacy of 110 lm/W and minimum 3900 lumens with CRCA housing with APFC constant Current driver for proper driving of LEDs and P.F.0.95 with THD10% ,CRI 80.The LED with life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700K- 6500K with CRI of minimum 80. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 3kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.

720

2200

1584000

... More
Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power (15-18 watt) LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency 85% . System Lumen efficacy of ≥ 110 lm / watt, THD 10 % , Pf.≥0.95, CRI 80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per approved by Engineer in charge.

170

1300

221000

... More
Supplying and fixingof Mirror light LED fitting with 9/11W LED lamp

60

900

54000

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

240

369

88560

... More
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.

-

-

-

... More
BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. 1200 mm Sweep BEE 3 Star rated (service value =5.0 to 5.5 )

240

2400

576000

... More
300mm/12" sweep exhust fan with louver type

72

1900

136800

... More
450 mm/18" Heavy duty

8

6800

54400

... More
400 mm sweep wall fan

40

2900

116000

... More
Supplying, installation, testing and commissioning of 150/150 Liters of water Cooler having full stainless steel body, cooling capacity 150 ltr/hour and storage capacity 150 ltr alongwith PVC connecting pipes as required. .

5

65000

325000

... More
Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.

-

-

-

... More
(RO + UV + UF mineral control with TDS control )

1

19500

19500

... More
UV purifier for water cooler (Commercial type)

5

13500

67500

... More
Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.

-

-

-

... More
4 KVA

5

9000

45000

... More
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)

-

-

-

... More
300 sq. mm 3.5 core (3 run) x2

600

2271

1362600

... More
185 sq. mm 3.5 core (3 run) x2

600

1466

879600

... More
150 sq. mm 3.5 core

30

1158

34740

... More
120 sq. mm 3.5 core

135

995

134325

... More
95 sq. mm 3.5 core

135

800

108000

... More
50 sq. mm 3.5 core

100

476

47600

... More
35 sq. mm 3.5 core

100

359

35900

... More
25 sq. mm 4 core

50

288

14400

... More
16 sq. mm 2 core

150

164

24600

... More
10 sq. mm 4 core

50

187

9350

... More
Supplying & laying of PVC insulated Copper power cable of 1.1 KV grade of following size on surfaces etc as required. (Un-armoured cable) 70 mm sq. single core

40

1500

60000

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required

-

-

-

... More
3½ X 35 sq. mm

8

369

2952

... More
3½ X 95 sq. mm (38mm)

8

588

4704

... More
3½ X 120 sq. mm (45 mm)

8

613

4904

... More
3½ X 185 sq. mm (57mm)

12

875

10500

... More
3½ X 300 sq. mm

12

1195

14340

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

50

247

12350

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

50

368

18400

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)

50

481

24050

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

300

669

200700

... More
150 mm width X 50 mm depth X 1.6 mm thickness

100

716

71600

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

5

1159

5795

... More
150 mm width X 50 mm depth X 1.6 mm thickness

5

1270

6350

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

5

1327

6635

... More
150 mm width X 50 mm depth X 1.6 mm thickness

5

1383

6915

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

5

1327

6635

... More
150 mm width X 50 mm depth X 1.6 mm thickness

5

1383

6915

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

5

1655

8275

... More
150 mm width X 50 mm depth X 1.6 mm thickness

5

1921

9605

... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow trace ability/ authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. LED Street Light fixture with Minimum lumen output 8700 lm

28

5500

154000

... More
SITC of Spike Earthing through GI Rod Electrode of 2.5 mtr length (Complete Job)

40

1600

64000

... More
Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. The work also includes cement concrete foundation. 8 Mtr.

15

15141

227115

... More
Providing installation, testing and commissioning of Double Door type main panel made of CRCA Sheet outdoor type, cubical feeder panel with 1.6 mm thick sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment. MCCB FP 63 amp 25 KA = 1 No. Metering and Indication Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set, MCB strips for required Nos. of MCB etc. = 1 set Aluminum Busbar High conductive electrolytic grade aluminium busbar of 240 Amp, TPN, with heat shrinkable sleeve, duly colour coded. =1 Set Timer Switch a) Timer Switch = 1 No. b) MCB 6 amp to 32 amp = 8 Nos. c) 1 x 1.5 sq. mm = 10 Mtrs.

2

28000

56000

... More
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.

15

15000

225000

... More
Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.

150

1162

174300

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

300

155

46500

... More
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.

15

12000

180000

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

150

244

36600

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

300

70

21000

... More
Supply, installation, testing, and commissioning of 225 mm (w) x 38 mm (h) 3 compartment GI underflood raceway

100

2340

234000

... More
Supply, installation, testing, and commissioning of Galvanised steel junction Box of size 225mm x 225mm suitable for 225mm(w) x 38mm (h) 3 compartment GI underfloor raceway

15

5250

78750

... More
Supply, installation, testing and commissioning of Galvanised steel riser along with coupler for joining with raceway of size 300mmx 300mm suitable for 225mm(w) x 38mm (h) 3 compartment GI underfloor raceway.

15

2700

40500

... More
SITC of ESE Stormaster type Lightening protection complete with the Lightning Air terminal configured as a spheroid which is comprised of separate electrically isolated 4 panels surrounding an earthed central finial. The insulation material used to electrically isolate the panels (anodisied aluminium) shall be comprised of a base polymer which provides high Ozone & UV resistance with a di-electric strength of 24.38 KV/mm tested as per NFC 17-102 & IEC 60-1:1989. As per NF C 17 – 102, the ESE air terminal shall be tested with the “Switching impulse Voltage” of 700 KV and “Direct Voltage” of 70 KV and certified by an international testing laboratory. The early streamer emission terminal shall be tested & certified by CPRI (Central Power Research institute) Govt. of India for the impulse current of 45 KA (8/20 micro sec) with 5 positive & 5 negative impulse. The ESE Stormaster terminal shall be recommended fr from DGMS (Director General of Mines Safety), Govt. of India. The ESE terminal shall not have any electronic circuit or any batteries inside to operate and it shall not depend on wind or solar to operate. The ESE terminal shall be tested and certified by any international laboratory as per IEC 60-1:1989 for an impulse current (8/20 micro sec) of more than 160 KA. The serial number displayed on the ESE lightning arrester shall be duly supported with the “certificate of country of origin” issued and duly sealed by the respective country (exported) “Chamber of Commerce & industry” indicating the serial number of the product supplied. The ESE terminal Shall offer protection radius of 68 mtrs at level 1/High protection and preferably to be mounted on the roof top & centre. (50-68 mtrs (Level I/ High Protection)

1

154568

154568

... More
SITC of Mast (G.I. pipe of 5 mtrs height) for mounting the terminal & adaptor with the stormaster ESE Air terminal alongwith supporting stray wires, etc.

1

14834

14834

... More
SITC of down conductor of 70 sq.mm single core insulated flexible copper cable with necessary accessories etc

100

876

87600

... More
SITC of Lightning strike recorder 6 digits mechanical display to record the lightning current in an IP 67 enclosure with the minimum sensitivity of 1500A & maximum capacity of 220 KA (8/20 micro second waveform). The recorder shall be of non-resettable type with the electro mechanical display No. LCD Screen is used as it may depend upon the battery life to energize the LCD. The lightning strike recorder shall be duly tested & certified inline with the ESE lightning arrester in an international laboratory of an impulse current (8/20 micro sec) more than 160 KVA as per IEC 60-1:1989 standard.

1

31473

31473

... More
SITC of advance maintenance free chemical gel earthing of Dual pipe technology (GI) of 3 mtr long, 80mm dia of outer shall (MS) with the 50mm dia of inner shall (MS) with 80-100 microns galvanized JK CHEMRODE filled with highly conducting metallic compounds with the permanent sealing at the both the ends with the lead terminal of 0 x 10 mm size at the top along with 50 kgs of RESLOW (mixture of Sulphate, Silica, Alumina, Iron Oxide, Titanium Oxide, Calcium Oxide, Potassium Oxide, Chloride, Magnesium Oxide, Sodium Oxide, Zinc Oxide etc.) Resistance lowering Grounding minerals. The loss on ignition by mass of the chemical compound RESLOW is less than 20%. The chemical compound RESLOW is tested and certified by any international accredited and BIS (Bureau of Indian Standards) accredited laboratory. The testing laboratory is an ISO 9001 & ISO 14001 certified. The JK-CHEMRODE shall be duly tested & certified by CPRI (Central Power Research Institute) Govt. of India for a minimum Short Circuit current of 30 KA rms. The Chemical earthing electrode manufacturer shall be an ISO 9001:2008 & ISOO 14001: 2004 certified organization.

4

21542

86168

... More
SITC of Test link Joint Kit in a IP 55 weather proof enclosure of suitable dimension.

1

4476

4476

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type with rotatory handle)

-

-

-

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.

-

-

-

... More
[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ). (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be

-

-

-

... More
Supplying, installation, testing & commissioning of AMF cum load management Panel compartmentalized type cubicle board, made of 2 mm thick CRCA sheet steel providing with suitable size angle iron and channel supported with suitable size of base channel for floor mounted dust & vermin proof duly phosphatized & powder coated, inclusive of suitable size 4 strip Aluminium busbar covered with heat shrinkable sleeves suitable size and length. The panel shall be suitable for incoming bus ducting and outgoing cables from top and bottom both sides, providing inter earthing and inter-connection with PVC insulated copper conductor cable, solid copper conductor of suitable sizes and lugs on both ends of each cable and making electrical mechanical interlocking in incomings and bus coupler and providing all meters with backup fuses & selector switches etc. I/O providing and fixing below noted accessories.

-

-

-

... More
Incoming:- Section-I 800 Amp 415 V FP ACB (EDO Draw- out type) having breaking capacity-50 KA, with short circuit earth fault & over-current relay - 1 No. (incoming from Transformer-1) (0-800 A) Digital Ammeter with selector switch & 800/5 C.T's - 4 set (0-500) Volt Voltmeter Digital type with selector switch- 4 sets RYB indication lamps with MCB- 4 set of three 800 Amp 415 V FP ACB (EDO Draw- out type) having breaking capacity- 50 KA, with short circuit, earth fault & over-current relay- 4 Np. (Incoming from Transformer-2) (0-800 A) Digital Ammeter with selector switch & 1000/5 C.T's - 4 set (0-500) Volt Voltmeter Digital type with selector switch - 4 sets RYB Indication lamps with MCB- 4 set of three Bus Couplers - 1 800 Amp 415 V FP ACB (EDO Draw- out type) having breaking capacity-50 KA, with short circuit, earth fault & over-current relay- 1 No. Electrical interlocking-electrical interlocking through contractors.

-

-

-

... More
Section-2 Incoming:- 500/400 Amp 415 V FP MCCB (EDO Draw- out type) having breaking capacity- 36 KA, with short circuit, earth fault & over- current relay- 1 No. (Incoming from DG1) (0-1600A) Digital Ammeter with selector switch & 1600/5 C.T.'s (0-500) volt Voltmeter Digital type with selector switch - 1 sets RYB indication lamps with MCB- 1 set of three 500/400 Amp 415 V FP MCCB (EDO Draw- out type ) having breaking capacity - 36KA with short circuit, earth fault & over-current relay- 1 No. (Incoming D/G-2) (0-1000 A) Digital Ammeter with selector switch & 1000/5 C.T's - 1 set (0-500) volt Voltmeter Digital type with selector switch - 1 set RYB Indication lamps with MBB - 1 Set of three Bus Couplers-2 500/400 Amp 415 V FP MCCB(EDO Draw- out type) having breaking capacity-36 KA with short circuit earth fault & over- current relay - 3 No. Electrical interlocking-electrical interlocking through contractors.

-

-

-

... More
Outgoing devices (MCCB's) 630 Amp, 50 KA, FP MCCB ICU = 100% ICS (1 No.)

-

-

-

... More
400 Amp, 36 KA, FP MCCB overload & short circuit, Microprocessor Based trip unit Micrologic (2 No.)

-

-

-

... More
250 Amp, 36KA, FP overload & short circuit, Microprocessor Based trip unit Micrologic (1 No.)

-

-

-

... More
200 Amp, 36 KA, FP overload & short circuit, Microprocessor Based trip unit Micrologic (1 No.)

-

-

-

... More
100 Amp, 30 KA, FP MCCB overload & short circuit, Microprocessor Based trip unit Micrologic (1 No.)

-

-

-

... More
160 Amp, 36 KA, FP MCCB overload & short circuit, Microprocessor Based trip unit Micrologic (6 Nos.)

-

-

-

... More
125 Amp, 36 KA, FP MCCB overload & short circuit, Microprocessor Based trip unit Micrologic (6 Nos.)

-

-

-

... More
1 No 32 Bit Microprocessor based PLC with MMI for auto load management, auto load sharing and synchronisation of all DG sets, sensing and signalling AMF logic to synchronising relay light Woodward/DIEF/Deepsea/PCCM/Equivalent, mounted on essential panel, selection of master DG sets, operation (opening/closing) of breakers like bus couplers, normal supply incoming and DG incomers, ACBs interlocking between ACBs etc. as required and complete with inter facing with DG set controller. PLC should have internal battery backup of 30 minutes. In case of failure of synchronising relay, there shall be provision t6o switch ON/OFF. In manual mode, all incoming breakers for transformers, DG sets and Bus coupler operation. Required wiring with necessary required accessories for manual mode operation shall be carried out by the contractors.

-

-

-

... More
Testing and Approval: • The contractor shall submit test certificates for the main switchgear and detailed drawings of the panel showing clear dimensions and spacing as per IE Standards. Drawings and test certificates must be approved by the Engineer In Charge before manufacturing. Any concerns may be referred to a third party for approval. • The panel must be as per IEC 61439 TTA type from any India based test laboratory (CPRI/ERDA etc.) for protection against short circuit/ temperature rise /internal arc / degree of protection. Additional Requirements: • Ensure compliance with local electrical codes and regulations. • Provide clear documentation and labelling inside the panel. • Ensure accessibility for maintenance and operation. • Securely mount and properly connect all components as per manufacturer guidelines. • Effectively ground the panel and include necessary safety features. • All MCCBs shall be of adjustable type and equipped with a rotary handle.

1

1700000

1700000

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar ( 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. Panel- 2 UPS Panel 2 Nos.) 1 UPS Panel = 8 CFT

16

2200

35200

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board (DB's/VTPNDB's) including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type with rotatory handle)

-

-

-

... More
100 Amp, 30 KA, FP MCCB ICU = 100% ICS

2

7723

15446

... More
Aluminium Bus Bar 300 Amp set of 4 strips

2

1000

2000

... More
TPN 63

10

1850

18500

... More
TPN 40

20

1750

35000

... More
Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set for required Nos. of MCB etc.

2

5000

10000

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar ( 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. Panel-3 (4 Nos. Floor panel) 1 floor panel = 18 CFT & X-ray panel

82

2200

180400

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type with rotatory handle)

-

-

-

... More
63 Amp, 25 KA, FP MCCB ICU = 100% ICS

5

6500

32500

... More
100 Amp, 30 KA, FP MCCB ICU = 100% ICS

5

7723

38615

... More
125 Amp, 36 KA, FP MCCB ICU = 100% ICS

4

8209

32836

... More
160 Amp, 36 KA, FP MCCB ICU = 100% ICS

4

13500

54000

... More
200 Amp, 36 KA, FP MCCB ICU = 100% ICS

2

15206

30412

... More
Aluminium Bus Bar 400 Amp set of 4 strips

4

1200

4800

... More
Aluminium Bus Bar 300 Amp set of 4 strips

4

1000

4000

... More
Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set for required Nos. of MCB etc.

8

5000

40000

... More
Capacitor Panel-1 (185 KVAR) INCOMER 1 No. 315Amps TPN MCCB METERING & INDICATION 1 set of phase indicating lamps 1 No. Microprocessor APFC controller/Relay shall continuously monitor all three phases and LCD displays for various Electrical Parameters like voltage, input current, capacitive current, KVA demand,KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232 C port. Controller should mounted on the front side of the panel. BUS-BAR 1 Set of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 1 No.of MCCB 100 TP MCCB with suitable AC -3 duty contactor 3 Nos.of 63A TP MCCB with suitable AC -3 duty contactor 2 Nos.of 25A TP MCCB with suitable AC -3 duty contactor

-

-

-

... More
2 Nos.of 20A TP MCCB with suitable AC -3 duty contactor 2 Nos.of 16A TP MCCB with suitable AC -3 duty contactor 1 No. 50 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 3 Nos. 25 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 3 Nos. 15 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 2 Nos. 10 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. 2 Nos. 5 KVAR capacitor Bank each with 7% harmonic & discharge resistor suitable capacity to carry expected current continuosly. Note:The capacitor panel shall also stipulate the following (i) All the capacitors shall be suitable for 525 V (ii) Necessary control and firing card with proper wiring and lugs of the required rating to be provided.

-

-

-

... More
(iii) Heavy duty exhaust fans to be provided for cooling (iv) LED indication for number of capacitor banks ‘ON & Power Factor lagging or leading. (v) The APFC shall be protected from following * over-voltage & voltage unbalance * Over temperature-system should be in standby mode and automatically restart after above condition restored. * Total Harmonic Distortion Supplying,Receiving, fixing, testing & commissioning of Capacitor panel as described above of Capacitor panel as described above

2

365000

730000

... More
Supply testing & commissioning of 60KVA True Online, DSP controlled online UPS with 3 phase AC input and 3 phase AC output with SMF battery bank for minimum 60 minutes battery backup with MS rack & accessories (min. VAH required for battery bank = 90000 VAH), The UPS should be with 3 level IGBT based rectifier & inverter technology with inbuilt/external 60 KVA Galvanic isolation transformer of same OEM make and with touch screen LCD/LED display for monitoring of its status. UPS should have following features: UPS power factor: Input PF should be 0.99 and output PF = unity, efficiency: overall efficiency (upto 96% without isolation transformer), communication interface : RS 232/USB port and optional SNMP port for remote monitoring, Audible Alarm: Mains failure/low battery/UPS Warning/ Overload/ Fault & Bypass Mode, CERTIFICATIONS & standard: ISO certification, EN/IEC 62040-2, EN/IEC 62040-3 compliance & CE/UE certification, compatibility with DG Genset, built in Automatic & maintenance bypass switch, with emergency power (EPO) feature, parallel mode. Warranty: 2 years on UPS 2 years on batteries battery make: Exide/Amaron-Quanta/Panasonic Make only with flexibility in no. of batteries ie UPS VDC flexibility Approved Brand: APC-Schneider/Emerson-Vertiv/Legrand-Numeric/Mitsubishi. The job further includes AMC of 60KVA UPS and batteries for a period of three years reckoned from date of successful commission (Which includes replacement of defective items of UP's/Batteries by fresh on during AMC Period.

1

2114697

2114697

... More
Supply, intastallation, testing & commissioning of 250 KVA Capacity Liquid Cooled turbo changed DG Set with suitable capacity engine directly coupled with alternator for 415 volt, 3 phase, 50 Hz, 4 wire, generation system complete with accessories, fuel oil tank & control panel etc as required and sound proof acquastic enclosure for the DG SET, including supply, fixing of antivibration pads suitable for 250 KVA DG Set as per standards of Engine manufacture, provision of conrol cable from engine to control panel to engine. Provision of pipe fuel pipe line of suitable size fron fuel tank to engine and over flow pipe engine to fuel tank complete gate valve and fitting leader maker etc. Supply , Intallation of starting batteries of suitable AH as recommended by manufacterer Heavy duty complete as required at site complete with stand and battery charger residentials sylencer sutaible for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all as required and as directed by engineer incharge. a) DIESEL ENGINE (CPCB-4 NORMS COMPLANT) 4 Stroke, Radiaotr Coolled, Diesel Engine Model Having Following Arrangement :- Flywheel with Starter Ring for Generating Set Air Filter , Lube Oil Cooler Assembly with accessories. Exhaust air manifold

-

-

-

... More
Exhaust Bellow Fuel Fiter Lube Oil Filter Exhaust Gas Turbocharger with after Coller Day tank for fuel with markings ECP Panel mounted on a separate frame. Radiator with Pusher Type Fan, With Fan Guard, Coolant Pump 24V Electrical Starting System with Starter Motor and Battery Charging Alternator Engine Mounting Supports Make Engine:- Cummins, Kirloskar & Volvo b) ALTERNATOR Rated at 250 KVA, 415 Volts, 3 Phase, 4 Wire, 0.8 P.F (lag), 50HZ, 1500 RPM, IN Accordance with IS 4722 as per following Specification Rating: Suitable for an over-load of 10% for 1 hour in every 12 hours operation. Voltage Regulation: Provided with fast response thyristor type electronic automatic voltage regulator, which holds output voltage within desired limits. (+/- 1%). Excitation: Self excited-self regulated.

-

-

-

... More
Alternator Loading: Suitable for taking rated load immediately after machine reaches rated voltage and speed. Vibration: Suitable for direct coupling with Engine and mounted on common M.S. Channel base frame. Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. Cooling: Air Cooled type with radial fan mounted on Rotor. Winding and Insulation: Insulation class H as defined in IS – 4722. ACCESSORIES :- MS Base Frame Suitable for Mounting of the Offered Engine and Alternator. Day Fuel Tank of Standard Capacity Complete Fuel Gauge, Inlet/Outlet Connections, Drains Plug, Etc 2 Nos 12 Volts DC Battery of SUITABLE Capacity with Leads 1 Set of AVM Pads Fitted in Base Frame.

-

-

-

... More
AMF Panel with standard acessoriesetc as required at site complete with Supply, intastallation, testing & commissioning of Supply, installation, testing & commissioning of AMF Panel with Microprocessor control /POWER DISTRIBUTION Panel consisting of 250 A 4 pole MCCB with O/L SC & ELR protection for EB mains Alternator with BYPASS SWITCH Floor mounting by means of dash fasteners as per the on-site requirements & as directed and also including of 03 Nos. earthing of the with required GI/Cu wires from the nearest point.

1

3250000

3250000

... More
Supplying and fixing of exhaust gas piping of 150mm dia. for 250 kVA rating D.G. Set welded black MS, 'B' Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, the work include necessary cladding of exhaust pipe work using wiremesh, 50mm thick Loosely bound resin(LBR)mattress / mineral wool/ Rockwool, density not less than 150kg/m and aluminium cladding (0.6mm thick min.) for temperature up to 450°C, complete portion complete as required as per specifications. Note- Contractor / Vendor to check the diaMeter of the exhaust pipes w.r.t. back pressure calculations & confirm the exhaust pipe sizes & suggest changes if required. This is to be done before supply of material / at the time of tendering. The contractor to measure actual pipe lengths as per site conditions & then confirm the suitability of pipe dia Meters supported by back pressure calculations.

20

2750

55000

... More
Supplying and fixing of insulation around the silencer including necessary cladding work using wiremesh, 50mm thick Loosely bound resin(LBR)mattress / mineral wool/ Rockwool, density not less than 150kg/m and aluminium cladding (0.6mm thick min.) for temperature up to 450°C, complete portion complete as required as per specifications.

1

12540

12540

... More
Supplying & fixing of Stainless Steel Expansion Joints, Corrugated bellow of following dia meter to fit in exhaust pipe.

1

12523

12523

... More
Providing, febrication & fixing for MS support structure including civil foundation for exhaust fume pipes upto 11m high from ground level and from DG Sets (Exhaust pipe to be measured and paid for separately) along horizontal and vertical runs as per soil testing as per the soil test report and monkey ladder upto the height (In case of when exhaust pipe far from the building) including cutting, welding etc and applying two coats of red oxide and two coats of synthetic enamelled paint of colour and shade as directed by Engineer/ Client/ Authority. The design of the support structure shall be done by the D.G. Manufecture/contractor and shall be as per CPCB norms-II including 300MM Long lightning arrestor on top, 20x3 mm G.I. down strips mount on insulator and aviation light including wiring and connections from near by D.B.. Design shall be got approved from the Engineer/ Client/ Authority before execution as required.

1500

109

163500

... More
Construction of PCC Platform for laying of DG set (Complete Job.) as per size and instruction of Engineer in Charge

1

50000

50000

... More
Supply Installation Testing and Commisioning of 4CX 2.5 sqmm FRLS Power Cable along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. (for DG)

60

210

12600

... More
Design, manufacture and supply of indoor/outdoor type of three phase 415 volt LT unbalanced 630 KVA servo controlled automatic voltage stabilizer copper wound oil cooled type designed for input voltage 190 V to 450 V phase to phase and output voltage 415 V ± 1% phase to phase and 230 volt ± 1% phase to neutral and frequency 50 HZ +/- 3%. The no load current shall not be more than 5% of the rated output current. The stabilizer shall be totally powder coated from outside to have aesthetic outlook and inside of tank should be zinc chromate painted. Panel should be screen-printed. The unit shall be housed in sheet steel of 14 gauge thickness having wheels with sturdy construction to withstand the rigorous shifting movement, repair works and handling. The unit shall be supplied with first filling of fresh filtered transformer oil having proper dielectric strength and shall be suitable for unbalanced input voltage and unbalanced output load . PROTECTIONS - Under voltage , over voltage , short circuit, overload and surge protection through suitable capacity MCCB BYPASS ARRANGEMENT - Bypass arrangement shall be provided through suitable capacity bypass switch and complete with cement concrete platform of required size as per instruction of Engineer in-charge and RiTES/CEIL (Tested) Certificate in this respect to be submitted. The job includes CAMC for 2 Years after DLP of 1 Year.

2

1690000

3380000

... More
Supply Installation Testing and Commissioning of 5MP or better Indoor Bullet camera with 5MP resolution (2592 x 1944) @30fps,motorisedvari focal lens, H.265/H.264/MJPEG Video Bit Rate 64 Kbps-5 Mbps, Audio Compression G.711/G.711U/ADPCM, Audio Bit Rate 64 Kbps-5 Mbps, Image Sensor 1/2.9" CMOS, Signal System PAL/NTSC, Min. Illumination Color: 0.02Lux@ (F2.0, ACG ON), B/W: 0Lux with IR, Shutter Time 1s to 1/100,000s, Day & Night Dual IR Cut Filter with Auto Switch, Wide Dynamic Range 120dB, Angle Adjustment Bracket, pan: 0° to 360°, tilt: 0° to 75°, rotate: 0° to 360°, Lens type - Fixed, Focus 4mm, Lens Mount M12, Aperture F2.0, Fixed FOV Horizontal field of view: 82.1° (4mm), IR LEDs 2, IR Range Up to 50m, Wavelength 850nm, Alarm Trigger-Motion Detection, Mask Alarm, IP Address Conflict, Protocols TCP/IP, HTTP, FTP, DHCP, DNS, DDNS, MULTICAST, IPV4, NTP, UDP, Telnet. Operating temperature -30°C~600C, 0-95% RH.System Compatibility ONVIF (PROFILE S/G), Protection IP67, Lightning protection, surge protection IR=50 mtrs, SNR 70 dB, Quad Stream, SD Card Support: Up to 512GB.

64

15840

1013760

... More
SITC of 2MP IP PTZ Camera, with PoE, motorisedvari focal lens for 30x zoom, Minimum Illumination Color: 0.005 lux@F1.6 B/W: 0.0005 lux@F1.6 0 lux@F1.6 (IR light on), S/N Ratio ≥55Db, Effective Pixels 1920(H) x 1080(V), Image Sensor 1/2.8” 2MP PS CMOS (0.9071 centimeters), RAM/ROM 512MB/ 256MB, Electronic Shutter Speed 1/1s~1/30,000s, Focal Length 4.8mm~120mm Focus Control Auto; Semi-auto; Manual White Balance Auto; indoor; outdoor; tracking; manual; sodium lamp; natural light; street lamp Close Focus Distance 1.5 m, Resolution 1080P (1920 × 1080); 1.3MP (1280 × 960); 720P (1280 × 720); D1 (704 × 576/704 × 480); CIF (352 × 288/352 × 240) IVS and face detection support, Weather Proof Standard IP66; TVS 6000 V lightning proof; surge protection; voltage transient protection, Certificates are required ISO 9001, ISO 14001, ISO 27001, CMMI 5, BIS, GDPR and Cyber Security Built-in IR illuminator with 150m viewing distance etc complete as reqd.

3

95000

285000

... More
Supply Installation Testing and Commissioning of 32 Ch Embedded Network Video Recorder with Video Input 64-ch, Max Resolution 12MP Two-way Audio Input 1-ch, 3.5mm, Bandwidth Income 320Mbps; Outgoing 320Mbps. HDMI/VGA Output -HDMI 2 ch, 3840×2160, 2560×1600, 2560×1440, 1920×1080, 1440×900, 1366×768, 1280×800, 1280×720,1024×768, 800×600 ,VGA 2-ch, 1920×1080, 1440×900, 1366×768, 1280×800, 1280×720, 1024×768, 800×600.Decoding Format IH+265/H.265/H.264, 8 SATA interfaces for 8 HDDs ,capacity Up to 10TB for each HDD, 1eSATA interface, Array Type JBOD, RAID0/1/5/6/10, USB Interface 2xUSB 2.0, 1xUSB 3.0, Protocols- TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, PPPoE, NTP, UPnP, SMTP, I GMP, QoS, IPV4, IPV6, Multicast, ARP, UDP, SNMP, SSL, Telnet, RTMP, NFS, System Compatibility ONVIF (PROFILE S/T), operating temperature -10°C~55°C, 10%~90% RH.

2

165000

330000

... More
Supply, Installation, Testing and comissioning of 8 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link

8

12200

97600

... More
Supply, Installation, Testing and comissioning of 16 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 16 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link

1

19200

19200

... More
Supply, Installation, Testing and comissioning of 24 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 24 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link

1

36000

36000

... More
Supply, Installation, Testing and Commissioning of 8-Ports 10/100/1000Mbps PoE + 2-Ports SFP 100/1000Mbps Smart Managed Switch, 130Watts,Switch Should Support 8 x 10BASE-T/100BASE-TX/1000BASE-T POE Ports, 2 100/1000 Mbps SFP ports, auto- negotiatiation ports, 130 Watts Power Budget.Switch Should Support Min. 20Gbps Switching Capacity and Maximum 64 Byte Packet.Forwarding Rate is 14.88Mpps, MAC Address Table: 8K and 4.1 MBits Packet Buffer, 256 Static MAC Entries.Switch Should support Time based POE & CPU Protection.Power Saving (Green) EEE 802.3az Energy Efficient Ethernet (EEE). Switch Should Support 4 Queues per port, Traffic Prioritization 802.1p, Strict Priority, Bandwidth Control: Port-based (Ingress/Egress, min granularity 10/100/1000 is 16 Kbps),Switch Should Support Access Control List based on: 802.1p priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles / Rules: 50 / 768,Switch Should Support 802.1X Authentication, Max. 128 entries when using local database, IPv6 RADIUS server, MD5 authentication,Switch Should Support DoS attack prevention, Port Security: Max. 64 MAC Addresses per Port, Broadcast/Multicast/Unicast Storm Control, DHCP Server Screening, Support 2 IP Interface & IPv6 Neighbour Discovery (ND), Traffic segmentation,Switch Should Have FCC Class A,CE Class A,IC Class A, UL Certifications.Make: HP, CISCO, DLINK, EXTREME

1

22836

22836

... More
Supply, Installation, Testing and Commissioning of 24 Ports 10/100/1000Mbps PoE + 4 Ports 10G SFP+ Smart Managed Switch(370Watt, surge 6KV),Switch with at least 24 X 10/100/1000 Mbps PoE Ports and 4 x 10G SFP+ Ports. 1 x RJ-45 Console Port.Switch Should Support Link status detection, Port and LED shut-off, System hibernation, Time-based PoE (PoE models only),Switching capacity should be 128Gbps or higher or non-blocking architecture,Switch packet forwarding rate should be 95.24 Mpps or higher or non-blocking architecture,Switch Should Support IEEE 802.3af & at compliance (for PoE ports) and 370W Power Budget,Switch MAC table should be at least 16K or higher.Support for the Energy Efficient Ethernet (IEEE 802.3az) standard.Switch Should Support Access Control List based on (ACL's) 802.1p priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles / Rules: 50 / 768,Switch should support IEEE 802.1Q VLAN tagging for Ethernet frames,Different type of VLAN like Port based, Auto Surveillance, Auto Voice, Asymmetric Vlan etc. should be available for configuration,Switch should support QoS (quality of service) IEEE 802.1P for traffic prioritization. 8 queues per port. Should have SSH and SSL for IPv4 and IPv6,Require prevention of DoS attacks, Should have option to check the status of copper cables using the cable-diagnostics time domain reflectometer (TDR).Should have dual Image support to reduced down time for the switches.Switch should support dynamic host configuration protocol (DHCP) auto configuration of multiple switches through a boot server eases switch deployment.

1

65000

65000

... More
Supply, Installation, Testing and Commissioning of 16-Ports 10/100/1000Mbps PoE + 2-Ports SFP 100/1000Mbps Smart Managed Switch, 130Watts,Switch Should Support 8 x 10BASE-T/100BASE-TX/1000BASE-T POE Ports, 2 100/1000 Mbps SFP ports, auto- negotiatiation ports, 130 Watts Power Budget.Switch Should Support Min. 20Gbps Switching Capacity and Maximum 64 Byte Packet.Forwarding Rate is 14.88Mpps, MAC Address Table: 8K and 4.1 MBits Packet Buffer, 256 Static MAC Entries.Switch Should support Time based POE & CPU Protection.Power Saving (Green) EEE 802.3az Energy Efficient Ethernet (EEE). Switch Should Support 4 Queues per port, Traffic Prioritization 802.1p, Strict Priority, Bandwidth Control: Port-based (Ingress/Egress, min granularity 10/100/1000 is 16 Kbps),Switch Should Support Access Control List based on: 802.1p priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles / Rules: 50 / 768,Switch Should Support 802.1X Authentication, Max. 128 entries when using local database, IPv6 RADIUS server, MD5 authentication,Switch Should Support DoS attack prevention, Port Security: Max. 64 MAC Addresses per Port, Broadcast/Multicast/Unicast Storm Control, DHCP Server Screening, Support 2 IP Interface & IPv6 Neighbour Discovery (ND), Traffic segmentation,Switch Should Have FCC Class A,CE Class A,IC Class A, UL Certifications.Make: HP, CISCO, DLINK, EXTREME

1

45000

45000

... More
Supply Installation Testing and Commissioning of Enterprise Surveillance HDD of 6TB .

4

17500

70000

... More
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as pre approved by Engineer in charge.

3300

57

188100

... More
Supply Installation Testing and Commissioning of Category 6 RJ-45 Connector.

50

38

1900

... More
Supply Installation Testing and Commissioning of Category 6 UTP Patch Panel Blank Punch Down 24 Port.

4

4350

17400

... More
Supply Installation Testing and Commissioning of 55" Screen 4k Industrial Grade 24/7 operation display with HDMI and HDMI cable.

2

75000

150000

... More
Supplying and fixing of following sizes of 25 MM PVC conduit(Medium Duty ISI) along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-.

3000

145

435000

... More
Supply Installation Testing and Commisioning of 3X 2.5 sqmm FRLS Power Cable along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.

650

160

104000

... More
Supply Installation Testing and Commisioning of 4K Hdmi Cable with all accessories as required with length of 10 Mtr.

2

4520

9040

... More
Supply Installation Testing and Commissioning of 6U Front Glass Door Single Section Wall Mount Cabinet Loaded with all Accessories like PDU , Cable Manager, Mounting Kit.Make- Duranet, Netrack, Dlink, APW, Rittal

7

7000

49000

... More
Supply Installation Testing and Commissioning of 4U Front Glass Door Single Section Wall Mount Cabinet Loaded with all Accessories like PDU , Cable Manager, Mounting Kit.

7

6000

42000

... More
Supply Installation Testing and Commissioning of 15U Front Glass Door Cabinet Loaded with all Accessories like PDU , Cable Manager, Mounting Kit.

2

15700

31400

... More
Supply Installation testing and commissioning of 3 KVA True Online , DSP Controlled online UPS with 1 phase AC input 50Hz and 1 phase AC output with 60 minutes backup on 12V SMF batteries Bank with Rack along with inter connecting battery cables and cable from UPS to Battery bank. The UPS should be with IGBT Based Rectifier and Inverter and with LCD/LED display for monitoring of its status along with inbuilt Galvonic Isolation Transformer. UPS should have following Features: UPS power factor : Input PF should be 0.99 AND output PF not less than 0.9 , Efficiency: up to 97% without Isolation ,Communication interface :RS232/USB port and optional SNMP compatibility for remote Monitoring , Audible Alarm : Mains Failure/Low battery /UPS Warning /Overload/Fault & Bypass Mode , THDI: not more than 5% , Noise Level less than 70db ,CERTIFICATIONS & Standard : ISO-9001-14001 Certified ,Compatibility with DG Genset , Built in Automatic & Maintenance Bypass Switch , Warranty : 2 Years on UPS as well as on Batteries,

2

165200

330400

... More
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge. Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord

-

-

-

... More
1 Mtr

90

223

20070

... More
3 Mtr

75

358

26850

... More
Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, G.I/PVC Box, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.

100

650

65000

... More
Supply and Installation of 8 Port Switch Networking Switch

6

3000

18000

... More
SITC of Single Phase SPN MCB type Surge Protection Devices 40 KA

8

8500

68000

... More
CAMC for CCTV 03 years after Defect liability period of 01 year

1

150000

150000

... More
Supplying, installation, testing and commissioning of ABC Type (MAP 90) 4 Kg Capacity. Specification ABC Type (MAP 90) 4 Kg Capacity Stored Pressure 6 minutes that's all the time a spark takes to grow into a raging fire and get out of control. That's also all the time you get fight the flames and stop the fire from spreading. Ceasefire's ABC extinguishers are built for speed, power and reliability when it come to fighting class A, B, C and electric fires. A simple two-step activation mechanism allows you to fight the fire within seconds. The best Mono Ammonium Phosphate maximizes the fire fighting power available to you. And stringent quality control and multiple point testing systems ensure that these extinguishers will deliver. IS 15683 Rating: 144B EN Rating: 144B Certification: LPCB BIS & EUROCERT Gross Weight: 6.71 to 6.87 kg Net Weight: 3.92 to 4.08 Kg Warranty: 6yrs, Make: Cease Fire, Safex, Minimax

8

9274

74192

... More
Supplying, installation, testing and commissioning of Co2 Based Extinguisher 4.5 Kg. Specification Co2 Based Extinguisher 4.5 Kg. flammable liquids such as petrol and oil (Class B) are highly combustible in nature. A single spark of fire can lead to an explosive fire incidence, Which in no time can turn into and inferno. Ceasefire's range of CO2 extinguishers are very effective in putting out larger fires. Being sturdier and lighter, these extinguishers save the time involved in carrying the extinguishers save the time involved in carrying the extinguisher to the fire. Packed with tremendous power. Ceasefire's CO2 extinguishers cut off the oxygen supply and bring the temperature down drastically stopping the fire in seconds. IS15683 ratings: 55B EN Rating: 55 B Certification : LPCB BIS & EUROCERT Gross Weight: 17.80 to 19.20 kg Net Weight: 4.275 to 4.275 kg Warranty 10 yrs. Make: Cease Fire, Safex, Minimax

4

17700

70800

... More
Supply and Erection of MS angle iron bucket stand which include 6 Nos. fire bucket with 9 ltr. Capacity with sand filling including cost of fabrication, welding and painting of complete stand & buckets with one coat of red oxide and two coats of approve paint of red color written with fire on the buckets as per fire protection with all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work.

2

15165

30330

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 3mm thick, suitable for 11 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .

10

2275

22750

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 2mm thick, suitable upto 3.3 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .

12

1896

22752

... More
Supply and fixing in position approved shock treatment chart written in English, Hindi and local language. These charts shall be framed in wooden frame and covered with clear glass.

4

5055

20220

... More
Supply of First aid box as approved by St. John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963.

4

5365

21460

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

6

2698

16188

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

292

1168

... More
Supplying of Rubber gloves of 11 KV grade as per IS 4770-68.

4

1192

4768

... More
Supplying and fixing of MS sheet board of size 500mm x 300mm of 16 SWG with 'Entry Restricted to Authorised Person Only" near the main entrance of the Sub- Station. The lettering shall be black painted on yellow base or as approved by engineer incharge.

4

632

2528

... More
Supply and fixing safety instruction chart both in Hindi & English duly framed with 3 mm thick glass as required. (approximate front area 1.00 sq. Meter)

4

5308

21232

... More
Supply, unloading, placing on foundation, installation, erection, testing and commissioning of 630 kva, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Copper wound), and with LV Cable Box having detachable Aluminium Gland plate. (1 No.) 11 kV Gapless Surge Arrestor, 9 kV, 10 kV, LA with polymer housing, stn. Type (1set) 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical type (1 set) 11 KV Horn Gap Fuse Set 3 Phase 200 A (1 set) 400 mm² (2 Ckt for 630 kVA), single core Cable, 1.1kV Grade, XLPE insulated stranded Conductor FRLS type (44mtr for 1 ckt) (132 Mtrs.) 9 Mtr. Long Pole, (ST-410 SP33) (2 No.) 11kV Polymeric composite Disc Insulator 12 kV, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm (3 Nos.) GI Channel/Angle/Flat of sizes including clamps (150 KG) Galvinized Nuts and Bolts (6 KG)

-

-

-

... More
Earthing of Substation Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement material and earth Chamber made of brick masonary with RCC slab cover. (Transformer) (3 Nos.) Transformer Pad/G.I Channel Bedding (300 KG) 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm (3 Nos.) Galvanised stay set with 50x8mm stay clamp, guy insulator (2 Nos.) anchor plate (200 x 200 x6)mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete. (2 Set) Wedge Connectors/PG Clamps (6 Nos.) Danger Plates with Clamps (1 No.) GI Basrbed Wires for Anti Climbing (15 KG) 3 Phase 4-wire Trivector Meter with CT (1 No.) Cement Bottoming 1:2:4 mix as per Standards 0.5 cum/ pole (4 Nos.) Painting of poles Red Oxide (2 Ltr) Painting of poles Aluminium Paint (1 Ltr) Sundry items like Aluminium lugs, Jumpers, Binding Tape 1 (L.S)

2

1650000

3300000

... More
Supplying, installation, testing & commissioning of tapping point on 9 mtr steel tubular pole with all accessories as required.

1

100000

100000

... More
Supplying, installation, testing & commissioning of oil cooled CT/PT of suitable ratio as per load alongwith trivector meter. (Complete Job)

1

120000

120000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.