Public Works Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date21 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 18,33,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

130

275

35750

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.

-

-

-

... More
1 x 1.5 sq. mm

60

45

2700

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

50

145

7250

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

6

103

618

... More
3 pin 5/6 A socket outlet

6

122

732

... More
15/16 A switch

2

156

312

... More
6 pin 15/16 A socket outlet

2

197

394

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

3

477

1431

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections as required.

6

586

3516

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

2

369

738

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

6

40

240

... More
Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.

-

-

-

... More
6 way (Double door)

1

2206

2206

... More
12 way (Double door)

1

2315

2315

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm

12

600

7200

... More
LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency 100 lumens/watt P.F .90 .

2

400

800

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

12

256

3072

... More
Single pole and neutral 40 Amp

1

750

750

... More
Single pole and neutral 63 Amp

1

850

850

... More
Supplying and fixing of following electrical items with complete connection as required.

-

-

-

... More
Fan Sheet

2

35

70

... More
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.

-

-

-

... More
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. 1200 mm Sweep BEE 3 Star rated (service value =5.0 to 5.5 )

2

2400

4800

... More
Exhaust fan 300 mm size (metalic)

6

1800

10800

... More
Supplying and fixing of 9 watt LED Mirror light fitting complete with connections etc.as required.

2

800

1600

... More
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)

-

-

-

... More
10 sq. mm 2 core

50

143

7150

... More
16 sq mm 2 core

60

189

11340

... More
Supply, installation, testing and commissioning of 9 Watt recess/surface mounted LED Bulk Head having Aluminum Body, minimum lumens 100 Im/w, the luminaire housing should be crca/aluminium and the luminair optics shall have a high efficency with transmittance, average life of 50000 hrs operating temperature -10 ºC to + 45 ºC incl. making of necessary connections. (Samples are to be approved by Engineer Incharge before execuation after submission of data sheet on OEM Letter Pad or third party to be nominated by department if required.

4

750

3000

... More
Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 Nos. long tubular batteries 150 AH and trolly of suitable size.

1

55000

55000

... More
Supplying and fixing of (70 + 5) watt LED Street Light complete with M.S/GI pipe bracket duly embeded along the parapet /wall including complete connections as required.

2

7500

15000

... More
Design, manufacture and supply of outdoor type of three phase 415 volt LT unbalanced 10 KVA servo controlled automatic voltage stabilizer copper wound oil cooled type designed for input voltage 160 V to 450 V phase to phase and output voltage 415 V ± 1% phase to phase and 230 volt ± 1% phase to neutral and frequency 50 HZ +/- 3%. The no load current shall not be more than 5% of the rated output current. The stabilizer shall be totally powder coated from outside to have aesthetic outlook and inside of tank should be zinc chromate painted. Panel should be screen-printed. The unit shall be housed in sheet steel of 14 gauge thickness having wheels with sturdy construction to withstand the rigorous shifting movement, repair works and handling. The unit shall be supplied with first filling of fresh filtered transformer oil having dielectric strength and shall be suitable for unbalanced input voltage and unbalanced output load. PROTECTIONS - Under voltage , over voltage , short circuit, overload and surge protection through suitable capacity MCCB BYPASS ARRANGEMENT - Bypass arrangement shall be provided through suitable capacity bypass switch and complete with cement concrete platform of required size as per instruction of Engineer in-charge and RiTES/CEIL (Tested) Certificate in this respect to be submitted. The job includes CAMC for 2 Years after DLP of 1 Year.

1

90000

90000

... More
Supply , Installation of Hot Dip Galvanised 11 mtr High Mast for LED flood lights with motorised carriage of aproved makes with its accessories. Mast shall be in One or two sections hot dip galvanised and suitable for wind velocity as per IS:875 (i.e 55 m/sec) with min overlap of 300m or 1.5 times dia at penetration with min 360mm Botton and 150 mm Top Dia. and thickness of 3 mm and 3 mm respectively. It should also include acessories of the high mast including head frame, steel wire rope 6mm (Dia 7/19 construction), Trailing cable, double drum winch, galvanised luminaire Carriage suitable for required luminaries symmetrically or asymetrically as shown in the lighting design and its control gear boxes, lighting final. The mast shall have integral power tool installed in the base compartment for its operation including one Set ( 8 No ) of foundation bolts of min T.S of 650 N/sq.mm manufactured from special steel along with nuts , washers, anchor plates and templates. Make Valmont, Transrail, Bajaj, CG, Havells. Note :- for the conection between 8 no high mast flood lights to be installed at the ring and main distribution panel contractor has to use 3 core 2.5 sq.mm flexible cable as per requirement at site (no extra cost will be provided to the contractor for the same). Providing reinforced cement concrete foundation of size and design/drawing as per Mast Manufacturer i.e OEM foundation of size and design as per Mast.Erection of 11mtr height metallic pole in cement concrete 1:3:6 stone aggregate 40mm nominal size foundation including excavation and refilling etc as required.

-

-

-

... More
Providing reinforced cement conrete foundation of size and design/drawing as per Mast Manufacturer i.e. OEM foundation of size and design as per Mast.

4

185500

742000

... More
SITC of 200 W LED flood lights with min 120 lumens /watt with min IP 65 protection.Make : philips/ Bajaj/ CG/ Lumen /Havels

16

16000

256000

... More
SITC of the main control panel double door outdoor type cubical of size (LxBxH) (2'x1'x2.5') with four legs and 1 feet above ground level, 16 SWG sheet steel powder coated including , MCCB 63 a 1 no., 1 no., ammeter and 1 no. , Ammeter AND 1NO. Voltmeter 6 no. single pole mcb, 1no. SPN 63 A, phase indicators, Digital timer along with locking arrangement , provided with 1kva servo of make:- power control electric/electric field/Jaima marked and all the accessories are made up of make:- schinder electric, L&T Legrand. And writing words/alphabets with synthetic enamel paint (As per direction of Engineer Incharge)

4

40000

160000

... More
Supplying, Testing, Laying and making indoor end termination with aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 16 Sq. mm 4 core)

165

210

34650

... More
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode shall be tested from CPRI. The earthing pit should be covered with PVC cover.

4

9000

36000

... More
Providing and laying of 25 x 5 mm G.I strip from G.I rod upto the main panel.

5

206

1030

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

5

70

350

... More
Supply, unloading, placing on foundation, installation, erection, testing and commissioning of 25 kva, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Copper wound), and with LV Cable Box having detachable Aluminium Gland plate.

1

73608

73608

... More
11 kV Gapless Surge Arrestor, 9 kV, 10 kV, LA with polymer housing, stn. Type

1

5200

5200

... More
11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical type

1

7280

7280

... More
11 KV Horn Gap Fuse Set 3 Phase 200 A

1

4936

4936

... More
25 mm² (1 Ckt for 25 kVA), single core Cable, 1.1kV Grade, XLPE insulated stranded Conductor FRLS type (44mtr for 1 ckt)

44

47

2068

... More
9 Mtr. Long Pole, (ST-410 SP33)

2

13158

26316

... More
11kV Polymeric composite Disc Insulator 12 kV, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

422

1266

... More
GI Channel/Angle/Flat of sizes including clamps

250

109

27250

... More
Galvinized Nuts and Bolts

8

115

920

... More
Earthing of Substation Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement material and earth Chamber made of brick masonary with RCC slab cover. (Transformer)

3

2287

6861

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

9

252

2268

... More
LT Distribution Box for 25 kVA DTR with MCCB 4P (50KA) adjustable 1 No. for incomer & SFU's for outgoing circuit

1

19028

19028

... More
Galvanised stay set with 50x8mm stay clamp, guy insulator (2 Nos.) anchor plate (200 x 200 x6)mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete.

2

3904

7808

... More
Wedge Connectors/PG Clamps

6

451

2706

... More
Danger Plates with Clamps

1

154

154

... More
GI Basrbed Wires for Anti Climbing

10

140

1400

... More
Cement Bottoming 1:2:4 mix as per Standards 0.5 cum/ pole

2

1936

3872

... More
Painting of poles Red Oxide

2

307

614

... More
Painting of poles Aluminium Paint

2

512

1024

... More
Sundry items like Aluminium lugs, Jumpers, Binding Tape

1

1076

1076

... More
32/63 Amps TPN Switch Disconnector fuse unit

1

1842

1842

... More
SITC of Labour Charges for Normal Terrain and Labour Charges for Hilly Terrain/Congested area and are stoarge and handling, safety equipments

1

43447

43447

... More
Supplying and Installation of 3 Phase Prodigy Meter

1

35000

35000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.