Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Security and Emergency Services
Eprocure
Opening Date24 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 1,03,76,000
Costs
EMD
₹ 2,07,520Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_268876_1Tender No
MDJ/Tech/e-NIT/2024-25/104Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://jkpwdrb.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
b) 150 mm dia
370
-
-
... More
c) 100 mm dia
150
-
-
... More
d) 80 mm dia
160
-
-
... More
e) 65 mm dia
10
-
-
... More
Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with Stainless Steel cap and chain as required: Single Headed Stainless Steel (Grade 304)
19
-
-
... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single Headed Stainless Steel (Grade 304)
5
-
-
... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30m
17
-
-
... More
Supplying and fixing 63 mm dia, 15 mtr. long RRL hose pipe with 63 mm dia. male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless Steel (Grade 304)
48
-
-
... More
Supplying & fixing 63 mm dia short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
24
-
-
... More
Supplying and fixing of Fire Man's Axe with heavy insulated rubber tested upto 20 KV and confirming to IS :926.
15
-
-
... More
Providing and fixing Weather proof hose cabinets for yard hydrant fabricated from 16 g MS sheet with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 nos.15m long hose, 1 No branch pipe and one fireman's axe. The cabinet shall be painted with one coat of primer and finished stove enameled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required.
24
-
-
... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. a) 150mm dia
7
-
-
... More
b) 100 mm dia
2
-
-
... More
c) 80 mm dia
27
-
-
... More
SITC of following accessories: a)Providing and fixing gunmetal single acting air release valve with screwed inlet 25 mm dia.(MR)
3
-
-
... More
b) Dial type pressure gauge with isolation cock and copper pipe at hydrant station. Dial diameter 100 mm calibration 0-15 kg/ sq.cm
17
-
-
... More
c) Pressure Switch
3
-
-
... More
d) 25 mm dia ball valve
2
-
-
... More
SITC of cast iron double flanged ISI marked Non Return Valve NRV confirming to IS: 5312 complete with rubber insertion, nuts, bolts, washers etc. of following sizes: a) 200 mm dia
2
-
-
... More
b) 150 mm dia
5
-
-
... More
c) 100 mm dia
1
-
-
... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm dia (DSR-18.15)
2
-
-
... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :- a) 2 way-100 mm dia M.S. Pipe
1
-
-
... More
b) 4 way - 150 mm dia M.S. Pipe
2
-
-
... More
SITC of stainless steel suction coupling for Fire Brigade drawl of water from fire tank of 100 mm dia.
1
-
-
... More
Design, Manufacturing, supply, installation, testing and commissioning of a digitally controlled oil cooled 250 KVA 3Ph copper wound wire servo automatic voltage stabilizer with input range of phase to neutral 150-240V. It should have “A” class insulation, degree of protection IP 54, winding and wiring material-copper EC grade (99.9% pure), transformer oil ISI-335 marked and conforming to IS-9815, ISO 9001-20015 to operate on unbalanced input voltage of 415+1% volts, 3 phase 50+3% cycles/second frequency, duly painted with providing and filling of transformer oil and with foundation of servo.
1
-
-
... More
SITC of Foot Valve for 150mm dia. pipe for the smooth drawl of water from storage water tank by the fire hydrant pumps complete in all respect as required on site.
2
-
-
... More
Providing & fixing 25 mm dia. UL listed gunmetal inspector test and drain valve with integral sight glass connected to drain line complete in all respects.
2
-
-
... More
Supply of addressable multi-sensor detector including mounting base with LED… etc. complete as required with inbuilt Isolators as per NFPA 72 style 7 wiring requirements or with isolator base/module for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be EN54 -VDS/UL-FM Certification
250
-
-
... More
Supply of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with 3 Loops modules and each loop capable of supporting not less than 125 detector and 125 devices; Loop length up to 1.5 km, 600 Character/7" Color LCD touch screen display with bright colors to indicate alarms and events, Integrated Ethernet Ports & 2 Nos of RS 485 for networking, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts. etc. The Panel shall support 8000 history logs in the nonvolatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories. Fire Alarm Panel and Public Address System should be of same make. Shall be EN54 -Vds/UL-FM Certification
1
-
-
... More
Supply of addressable Double ACTION manual call point & necessary fixing arrangements with key complete as required. MCP should have IP52 or better protection rating Shall be EN54 -Vds/UL-FM Certification
8
-
-
... More
Supply of Addressable Sounder with sound pressure 90 dB(A), Sounder should have IP40 or better protection rating. Shall be EN54 -Vds/UL-FM Certification.
8
-
-
... More
Supply installation testing commissioning of response indicator on surface/recess MS box having 2 LED, mettalic cover complete with all connections as required.
90
-
-
... More
Supplying, laying, testing and commissioning of 2C x 1.5 sq mm of Low Smoke Zero Halogen Silicon Insulated Fire Survival Cable with Drain Wire, solid copper conducter cable approved by LPCB as per BSEN 50200:2015 PH 120 (Fire, Mech Shock & Water 120 Minutes @ 830 deg Celcius, Fire & Mech Shock every 5 Min for 2 Hours- Both test conducted on same sample) and BS-6387 CWZ The cable shall sustain 950 deg. C. For 3 hours approved along with accessories/ termination glands and all necessary materials to complete. The cable shall be BS EN 60332-1-2:2004 for Bunched Flame Retardancy (installed as a single or bunched cable selfextinguishes leaving the upper cable sheath unaffected showing the cable does not propagate fire). Cable shall be guaranteed for 10 years from the date of manufacture marked on the cable.
3400
-
-
... More
Supplying, laying, testing and commissioning of 4 C X 1.5 Sq mm armored cable of Low Smoke Zero Halogen Silicon Insulated Fire Survival Cable .
1500
-
-
... More
Fabrication, SITC of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust & vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : INCOMING 400A, 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich& CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine. System Controller: DSITC of System Controller to control operation of main electric fire pump, diesel pump, Pressurization pump in sequence as per specification as per specification consisting of relays, timers, sensors, annunciation window for fault indication, complete as per specification.
1
-
-
... More
Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads as required:- 2280 lpm at 70 m Head
1
-
-
... More
Diesel Driven Pump Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520 with Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminum sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head
1
-
-
... More
Jockey Pump Supplying, installation, testing and commissioning of electric driven pressurization pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head
1
-
-
... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
1
-
-
... More
Supplying & laying of 4 core 10 sq mm Aluminum armoured cable from motor to electrical panel for automation of the system.
50
-
-
... More
Supplying & lying of 3.5 core 50 sq mm Aluminum armoured cable from motor to electrical panel for automation of the system.
100
-
-
... More
Supplying & lying of 2 x 1.5 sq mm dia. PVC insulated copper conductor armoured cable directly on the surface complete as req.
100
-
-
... More
Chemical Earthing of the Complete system.
2
-
-
... More
P/f 25 mm x 5 mm G.I strip from earth electrode, on surface or in recess for earth connections as required.(mtr )
50
-
-
... More
Providing and fixing ABC powder type fire extinguishers consisting of welded M.S. cylindrical body automatic modular ABC powder type extinguisher actuated through a sprinkler head mounted on The extinguisher body finished externally with red enamel paint and fixed to ceiling with brackets complete with internal charge.
15
-
-
... More
Providing and fixing ABC powder type fire extinguishers consisting of welded M.S. cylindrical body ABC powder type extinguisher finished externally with red enamel paint and fixed to ceiling with brackets complete with internal charge.
5
-
-
... More
Providing & fixing CO2 type fire extinguishers 4.5 Kg cap. Complete with wheel valve arrangement, high-pressure wire Braided hose pipe as req.
15
-
-
... More
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
1
-
-
... More
Dismantling of Stairs by Demolishing cement concrete manually or by mechanical means including disposal of material with in 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix)
2.34
-
-
... More
Dismantling of M.S Railing of stairs by way employing cutter, welding machine and other tools and tackles required for railing including stacking the dismantled material at one place. Complete Job includes cost of material, labour charges and other tools and tackles required for the execution of Job.
1
-
-
... More
Site Preparation Earthwork in excavation by manual means over area for leveling purpose including disposal of excavated earth up to 50m from cutting edge and should be disposed in near-by all kind of soil Foundation for plinth work = 44’-0”-0” x 1’-6” x 1’-6’ ’= 99ft3 Foundation for plinth protection = 44’-0” x 1’-6” x 0’-6” = 33 ft3 Total = 132 ft3 = 3.74 m3 Area to be excavated keeping in view the earth quake resistance for which a ms mesh (10 mm) is to be provided in the base foundation of the plinth
3.74
-
-
... More
Providing and laying of cement concrete (1:4:8) using 40mm nominal size nallah stone. Plinth work = 44’-0” x 1’-6” x 0’-6’’= 33 ft3 Flooring=12’-0” x 10’-0” x 0’-3’’= 30 ft3 Plinth Protection=44’-0” x 1’-6” x 0’-3” = 16.5ft3 Total = 79.5 ft3 = 2.25m3
2.25
-
-
... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (one cement: Two coarse sand: Four Graded stone aggregate 20 mm nominal in size) Plinth work = (44’-0” x 1’-6” x 1’-0’’) + (44’-0” x 1’-0” x 1’-0’’) = 110 ft3 Flooring = (12’-0” x 10’-0” x 0’-9’’) = 90 ft3 Plinth Protection = 44’-0” x 1’-6” x 0’-6”= 33 ft3 Slab = (14’-0” x 12’-0” x 0’-6”) = 84 ft3 Beam = (44’-0” x 0’-9” x 1’-0”) = 33 ft3 DPC=44-0”X0-9”X0’-6”= 16.5 ft3 Stair= S = 10 x (5’-0” x 2’-6” x 0’-6”) + 9 x (5’-0” x 0’-6” x 0-6”) = 73.75 ft3 Total = 330.5 ft3 = 9.36 m3
9.36
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or Bars for Plinth Mesh 10 mm bar of length 310’ = 94.51 mtr = @ 0.617 kg per metre = 58.31 kg Bars for Tie beam 10 mm bar of length 176’ = 53,65 mtr = @ 0.617 kg per metre = 33.10 kg 8mm bar of length Tie beam 356’ = 108.53 = @ 0.395 kg per metre = 42.86kg Flooring 10 mm bar of length 310’ = 94.51 mtr = @ 0.617 kg per metre = 58.31 kg Slab 10 mm bar of length 672’ = 204.87 mtr = @ 0.617 kg per metre = 204.87 kg Stairs=10 mm bar of length 280’ = 85.36 mtr = @ 0.617 kg per metre = 52.66 kg Total =450.11 kg (
450.11
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form work for: 4.6.1 Foundations, footings, bases for columns Area = (44’-0” x 1’-0”)+44’-0”X1’-0” = 88 ft2 = 8.17 m2
8.17
-
-
... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) Wall=44’-0”x10’-0”x0’-9”=330ft3 Total =330 ft2 Deductions: Window= (4’-0”x4’-6”x0’-9”) =18ft3 Door= (7’-0” x 3-6” x 0’-9”) =18.37ft3 Total=18.37 ft3 Total = 330 – 18.37 = 311.63 ft3 =8.83 m3
8.83
-
-
... More
Half brick masonry with common burnt clay (non-modular) bricks of class designation7.5 in foundations and plinth including curing in :Cement mortar 1:3 ( 1 cement : 3 coarse sand) Bathroom (44’-0” x 3’-0”)= Total=132ft2=12.26 m2
12.26
-
-
... More
12 mm cement plaster to wall of mix 1 : 4 (1 cement : 4 fine sand) Area = (44’-0” x 10’-0”) = 440 ft2 = 40.89 m2. Total = 40.89 m2
40.89
-
-
... More
6MM CEMENT PLASTER 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 10’-0”-12’-0”=120ft2=11.15m2
11.15
-
-
... More
15 mm Cement plaster on the rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 fine sand) Outer Wall 15’-0”x44-0”=660 Total=660ft2=61.34 m2
61.34
-
-
... More
Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete.2 mm thick Area=2x10’-0”x10’-0”+ 2x12’-0”x10’-0”+ x12’-0”x10’-0” Total=560ft2=52.05 m2
52.05
-
-
... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats Total=560ft2=52.05 m2
52.05
-
-
... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) Area=15’-0”x44-0”=660 Total=660ft2=61.34 m2
61.34
-
-
... More
Finishing wall with premium acrylic smooth exterior paint with siliconeadditives of required shade on New work (two or more coats applied @1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) Total=660ft2=61.34 m2
61.34
-
-
... More
Fabrication, Providing and Fitting of one number each Aluminum doors, windows with frame made out of Powdered coated aluminum of gauge not more than 12 mm including glass, rubber beading, aluminum Fly mesh, aluminum sheet panels for doors and other allied accessories. The total no. quantity of doors and windows are enclosed as per Annexure “A”. The color and final design is approved by Engineer in charge
1
-
-
... More
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single Socketed pipes 110 mm dia Length of pipe = 25ft = 7.62 mtr
7.62
-
-
... More
Electrification of the Pump Room by way of Providing and fitting of three number 20 watt 4 feet LED tube lights, 1 nos ceiling fans with regulator of 1200 mm sweep, 1 nos exhaust fans of 18” dia with lovers, 100 W LED Flood Light. Providing and fitting of 1 no. distribution panel consisting of MCCBs, MCBs, SPNs for different circuits. Providing and laying of main service line of size 16 sq. mm from main pole to MCB/distribution box and 1 mm sq. mm, 1.5 mm sq mm. 2.5 sq.mm pvc wire, 4 mm pvc wire for different power circuits. P/F of modular switches, sockets including providing and laying of conduits of different size in sslab and walls per site requirement. The job includes material cost ,labour cost and taxes
1
-
-
... More
Providing and fixing of MS railing minium height three feet on the sides of the stairs made out of sq. hollow section of size 75 mm , 50 mm & 25 mm. as per site requirement. It also includes primer and enamel paint minimum coat Job includes material cost, labour cost and taxes
1
-
-
... More
Providing and fitting of Polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet and outlet pipes including overflow pipes having capacity of 5,000 ltr (02 nos.) with fittings and foundation including all allied connections etc.
1
-
-
... More
CAMC charges for two years after the completion of 01 year warranty period
1
-
-
Evaluation Notes How It Works ?