Public Works Department Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Works Department - PWD Tender

Works
Eprocure
Opening Date4 Jan 2025
Closing DateCancelled
Tender Amount₹ 53,97,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, testing & commissioning of Hi-wall Indoor Unit of 1.5 TR capacity ,suitable to operate from 230+10% volt, 50 HZ, 1 phase power supply with cordless remote control, fittings & required cable to connect indoor unit to socket. Refrigerant Pipe size and gas quantity should suit to the copper pipe length at actual. The capacity guarantee should be ensured by the contractor/manufacturer. Each unit shall have Low gas detection system.

5

-

-

... More
Supply, Installation, testing & commissioning of Hi-wall Indoor Unit of 2.0 TR capacity ,suitable to operate from 230+10% volt, 50 HZ, 1 phase power supply with cordless remote control, fittings & required cable to connect indoor unit to socket. Refrigerant Pipe size and gas quantity should suit to the copper pipe length at actual. The capacity guarantee should be ensured by the contractor/manufacturer. Each unit shall have Low gas detection system.

6

-

-

... More
Supply, Installation, testing & commissioning of Hi-wall Indoor Unit of 2.5 TR capacity ,suitable to operate from 230+10% volt, 50 HZ, 1 phase power supply with cordless remote control, fittings & required cable to connect indoor unit to socket. Refrigerant Pipe size and gas quantity should suit to the copper pipe length at actual. The capacity guarantee should be ensured by the contractor/manufacturer. Each unit shall have Low gas detection system.

8

-

-

... More
Refrigerant Piping for VRV/VRF system. Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) with XPLE Class-O tubular/ closed cell electrometric nitrile rubber tubular insulation sleeves sections of specified thickness between each set of indoor & outdoor units with outer mechanical protection of aluminum cladding for all exposed pipes as per specification. All piping shall be properly fixed/supported with suitable size of clamp/ M.S. hanger, fasteners etc .

-

-

-

... More
6.4 mm dia with 13mm thick insulation.

55

-

-

... More
9.53 mm dia with 13mm thick insulation.

80

-

-

... More
12.7 mm dia with 13mm thick insulation.

160

-

-

... More
15.9 mm dia with 13mm thick insulation.

140

-

-

... More
19.1 mm dia with 13mm thick insulation.

90

-

-

... More
22.2 mm dia with 19mm thick insulation.

90

-

-

... More
25.4 mm dia with 19mm thick insulation.

45

-

-

... More
28.6 mm dia with 19mm thick insulation.

40

-

-

... More
31.8 mm dia with 19mm thick insulation.

30

-

-

... More
34.9 mm dia with 19mm thick insulation.

110

-

-

... More
Supply ,Installation , Testing and Commissioning of Y Joints( Rafnets) of various sizes as per design requirement(pair) (Liquid line and Vapour Line).

19

-

-

... More
Supply, Installation, Testing and Commessioning of centralized remote controller along with control wiring etc all capabling for monitoting at least 30 indoor units and one outdoor units.

2

-

-

... More
Supply, Installation, Testing and Commessioning of Power supply cable 1.5 Sq mm , 3 Core copper cable

1200

-

-

... More
Supply, Installation, Testing and Commessioning of Communication wire 18AWG(0.75 Sq mm) , 2 core stranded copper cable.

250

-

-

... More
Supply, Installation, Testing and Commessioning of Drain pipes including 9mmXLPE class-O tubular/Closed nitrile rubber insulation along with Tees, Bends,Collars or any other fittings required to complete the job.

-

-

-

300

-

-

700

-

-

... More
Providing and Fitting of perforated Hot Dipped Galvanised iron cable tray (glvanization thickness not less than 50 microns) with perforation not more than 17.5 % in convenient sections joined with connectors , suspended from the ceiling with GI suspenders including GI nuts and bolts (150 mm x50mmx1.6 mm )

700

-

-

... More
Pressure testing of the refrigerant piping circuit(s) upto 1.5 times working pressure for a period of 24 hours using nitrogen by way of flushing the nitrogen so that piping circuit is cleaned of allkinds of debris and to ckeck any leakages in the piping circuit fallowed by vacuuminisation of the the circuit till vacuum reading reaches 250 microns or less.

2

-

-

... More
Charging of the refrigerant piping circut with required quantity of refrigerant as per manufacturer’s recommendation & standard to maintain optimum performance of all Indoor & Outdoor Units.

2

-

-

... More
Supplying, installation, testing & commissioning of sub Panel factory assembled weather proof/ Dust & Vermin Proof wall / floor mounted LT cubical type compartmentalized panel of 100 Amp TPN Aluminum Busbar panel (CPRI Approved) fabricated out of 14 SGW/2 mm thick MS sheet, with locking arrangement, cable alleys, bus bar chamber etc powder coated self supported suitable for 3 phase 4 wire, AC supply, supplying & fixing following accessories as detailed below, i/c bus bars connections/inter connections to MCCB compartments, arrangement for cable entry, supports, end terminations, 2 No. earthing stud inter connection ,painting, etc. complete as required. The compartmentalized panel consisting of various outgoing compartments for MCCBs.The panel should be provided with 100 Amp TPN MCCB as main incommer from main panel,multifunctional digital metering module with suitable CT coils capable of reading voltage, current, frequency power factor etc , 2 No. MCCB's of 63 Amp TPN, 63 Amp RCCB (02 No.)The panel should be provided with 10 no mcbs of 6 Ampere each.

2

-

-

... More
Supply, laying, testing and commissioning of 4 Core 120 Sqmm aluminium armoured cable (XLPE) along with thimbles from main panel to sub panel . The job includes prior thimbling of the cables with heavy duty crimping tools followed by PVC tapping of the thimled joints.

140

-

-

... More
Providing and Laying of electric power cabling from floor sub panelsl to outdoor units copper armoured cable XLPE suitable for 415 v 3 phase 50 hz or as per recommendationd from OEM

-

-

-

... More
4c x 10 sqmm, copper

40

-

-

... More
4cx 16 sqmm, copper

40

-

-

... More
Cast in situ of concrete work of nominal mix concrete M7.5 grade for foundation including shuttering,curing etc 9ftx4ftx3ft=3cum

3

-

-

... More
Chemical Earthing (50mm dia G.I Pipe with Chemical bags) complete job.

2

-

-

... More
Supply, installation, testing & commissioning of 200 KVA servo-stabilizers including all allied electrical appurtenances.The stabiliser should have following specifications: a) Capacity: 200 KVA, 3-phase unbalanced type b) Input: (90-280) V AC P-N; (150 - 485) V AC P-P c) Output: 415 V ± 1% - phase to phase d) Supply: 3 phase, 4 wires, 50Hz e) Operation: Automatic f) Duty cycle: Continuous g) Transformer windings: Copper wound on CRGO laminations as per IS specifications h) Cooling: Oil cooled i) Efficiency: Better than 98% at full load j) Overload capacity: 15% for continuous 4 hours k) Waveform distortions: Nil l) High speed voltage correction: up to 8V to 20V per second m) Protections: Under voltage, Over voltage and Overload with time delay n) Other features: LED indicators, Digital AC ammeter, AC voltmeter, Frequency meters, Phase Sequence meters, Single phase preventer, Stabilizer by-pass arrangement.The equipmement should comply all relevent standards.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.