Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date9 Nov 2024
Closing Date25 Nov 2024
Tender Amount₹ 4,33,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.125mm DI pipe

1

218

218.4

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

1

12

12.49

... More
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.

-

-

-

... More
Beyond 30 cm girth upto and including 60 cm girth.

1

379

379.05

... More
Beyond 60 cm girth upto and including 120 cm girth.

1

1683

1683

... More
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil :

1

187

187.3

... More
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil :

1

89

89.75

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329 150 mm dia Ductile Iron Double Flanged

1

2295

2295.65

... More
Providing and fixing cast iron double flanged sluice valves PN -1.6 marked with IS 14846 including nuts and bolts marked with IS 1363, rubber sheet marked with IS 638 etc carriage, loading, unloading, stacking, handling, rehandling etc complete in all respect to the satisfaction of engineer in charge 100 mm dia.

1

4057

4057.95

... More
125 mm dia.

1

4373

4373.5

... More
150 mm dia.

1

5968

5968.85

... More
200 mm dia.

1

11608

11608

... More
250 mm dia.

1

16752

16752.05

... More
300 mm dia.

1

23159

23159.45

... More
Providing and laying S&S C.I. Standard specials suitable for mechanical jointing as per IS : 13382 Up to 300 mm dia.

1

11979

11979

... More
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). Depth exceeding 1.5 m but not exceeding 3 m

1

255

255.2

... More
Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete mix, diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) By percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete 600 mm dia M35

1

3151

3151.1

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap afte test etc. complete as per specification & the direction of Engineer-in- Charge. Single pile upto 50 tonne safe capacity Initial test (Test Load 2.5 times the safe capacity)

1

159533

159533

... More
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge ( chipping of pile heads)

1

2516

2516.85

... More
Providing and laying of dry Stone soling in horizontal on level.

1

1320

1320

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 5.3.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9821

9821.85

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9395

9395.7

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

1

5202

5202.9

... More
1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)

1

7275

7275.25

... More
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)

1

5673

5673.4

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement

-

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

7788

7788.4

... More
Providing and laying upto floor v level reinforced cement concrete in kerbs, steps and the like including curing but excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9023

9023.35

... More
Bick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand)

1

7571

7571.55

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

1

1455

1455.65

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level

1

8021

8021.1

... More
All works above plinth level upto floor V level

1

9412

9412.05

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.

1

9412

9412.05

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

1

98

98.8

... More
Extra for R.C.C./B.M.C./R.M.C. work above floor V level for each four floors or part thereof.

1

280

280.95

... More
Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein. (@5 qtls / Cum)

1

941

941

... More
Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete.

1

286

286.35

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

1

628

628.95

... More
Arches, domes, vaults upto 6 m span

1

2281

2281.2

... More
Extra for arches, domes, vaults exceeding 6 m span

1

1118

1118.85

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers.

1

577

577.55

... More
Suspended floors, roofs, landings, balconies and access platforms.

1

718

718.2

... More
Spiral staircases (including landings)

1

676

676.25

... More
Edges of slabs and breaks in floors and walls

1

262

262.3

... More
Extra for shuttering in circular work (20% of respective centering and Shuttering items)

-

-

-

... More
Foundations, footings, bases of columns etc. for mass concrete.

1

57

57.27

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

1

125

125.79

... More
Arches, domes, vaults upto 6 m span

1

456

456.24

... More
Extra for arches, domes, vaults exceeding 6 m span

1

223

223.77

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers.

1

115

115.51

... More
Suspended floors, roofs, landings, balconies and access platforms.

1

143

143.64

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (plan area to be measured)

1

293

293.9

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more.

1

123

123.2

... More
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gram/m2

1

1158

1158.35

... More
Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gram/m2

1

761

761.95

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement))

1

63

63

... More
12mm Cement plaster finished with a floating coat of neat cement of mix:

-

-

-

... More
1 : 3 ( 1 cement : 3 fine sand)

1

370

370.75

... More
1 : 6 ( 1 cement : 6 fine sand)

1

266

266.2

... More
Extra for plastering on circular work not exceeding 6m in radius: In one coat

1

37

37.8

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in- Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

1

1229

1229.1

... More
Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

1

1106

1106.05

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class kail wood

1

101081

101081.25

... More
Pre-laminated particle board with decorative lamination on both sides,Grade I, Type II IS : 12823 marked

1

1952

1952.35

... More
Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second kail wood (30 mm)

1

2597

2597.75

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Second Class kail wood / Kiln wood/ Imported wood

1

2305

2305.7

... More
Float glass panes: 5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm)

1

2139

2139.95

... More
Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :75x63x3.2 mm

1

78

78.2

... More
100x63x3.2 mm

1

106

106.85

... More
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :150x10 mm

1

83

83.8

... More
200x10 mm

1

95

95.35

... More
Providing and fixing aluminum round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-charge:Anodized (AC 15) aluminum

1

89

89.15

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).

1

207

207.35

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:2nd class teak wood 50 x 12 mm

1

214

214.75

... More
Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete.With stainless steel grade 304 wire gauge with wire of dia 0.50 mm With 2nd class teak wood beading 62x19 mm

1

1547

1547.7

... More
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.PN-16 pipe , 32mm OD(SDR-7.4)

1

519

519.75

... More
Providing & Installing PVC pipes (working pressure 4 kg / cm2 ) Single socketed pipe 110 mm dia with all necessary arrangements & fittings including Tee's, Elbows & End Caps wherever required complete job.

1

427

427

... More
Providing and fixing brass bib cock of approved quality.20 mm nominal bore

1

372

372.9

... More
Providing and fixing brass stop cock of approved quality.20 mm nominal bore

1

379

379.6

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid.

1

7713

7713.1

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Surgeon type wash basin size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers.

1

4493

4493.5

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Flexible pipe 32 mm dia

1

128

128.05

... More
Providing & Fixing PTMT bottle trap for wah basin or sink Bottle trap 31 mm single piece moulded with height of 270 mm effective lengent of tail pipe 260 mm from centre of waste copuling 77 mm breadth with 25 mm minimum water seal weighing not less than 270 grams.

1

596

596.3

... More
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

1

1474

1474.15

... More
Providing & Installing 25Ltr Geyser / Water Heater with all necessary arrangements complete.

1

5500

5500

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040mm bowl depth 200mm

1

5671

5671.85

... More
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded (Supplying and fixing MS DOOR with shutter and frame of approved make, made of required size made up of structural steel in single section and 2mm thick ms sheet)

1

138

138.2

... More
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded

1

138

138.2

... More
200mm dia Header distribution 6mm thick, 1.5m long, with reducer and inlet arms (100mm /150mm) 0.3mm each

1

114

114.63

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

1

218

218.4

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)

1

98

98.75

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work

1

131

131.85

... More
Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete

1

346

346.7

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 100 mm dia. nominal bore (GI Rising Mains / Supply main /Wash Out /Overflow Pipe) and Filling Line from OHT to Pump House to Collection chamber and to borewell/tubewell)

1

1430

1430.75

... More
Providing and fixing hard drawn steel wire fabric of size 75 x25 mmmesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. (At Crown of OHT Bird Proof Wire Mesh)

1

821

821.55

... More
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.

1

167

167.8

... More
Providing and fixing of water bars

1

281

281.85

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required Group B

1

1182

1182

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

1

233

233

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1

275

275

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32 mm

1

184

184

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch

1

103

103

... More
3 pin 5/6 A socket outlet

1

122

122

... More
15/16 A switch

1

156

156

... More
6 pin 15/16 A socket outlet

1

197

197

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

1

369

369

... More
Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ianored)

1

55

55

... More
Installation, tèsting and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq mm FRLS PVC insulated, copper conductor, single core cable etc as required.

1

213

213

... More
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.

1

57

57

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep

1

450

450

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required 32A TP&N

1

2152

2152

... More
63A TP&N

1

3144

3144

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 6 way , Double door

1

2206

2206

... More
Providing & Installing 8W Round Led Ceiling Light Complete job.

1

250

250

... More
Providing & Installing 200mm Exhaust Fan| Cut Out Size: 9.4x9.4 square inches| Watt: 32| RPM: 1350| Air Delivery: 520| Suitable for Kitchen, Bathroom, and Office

1

1300

1300

... More
Providing & Installing Electric Ceiling Fan | 1200mm BEE Star Rated Ceiling Fan

1

1500

1500

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both sideinclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board,all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-Part 1 : 2011 (Board with BIS certification marks)

1

1350

1350.65

... More
Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

1

276

276.6

... More
Supply and filling of filter media from approved source - Gravel (Graded gravel - size ranging from 2.0mm to 40.00 mm) in filter beds. Including all carriages, complete job

1

7000

7000

... More
Supply and filling of filter media from approved source - Sand (Coarse filter sand - in filter beds. Including all carriages, complete job

1

7100

7100

... More
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.

1

1204

1204.5

... More
Reinforced cement concrete work in arches, arch ribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with:

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size

1

10377

10377.15

... More
Reinforced cement concrete work in chimneys, shafts upto floor five level including curing complete but excluding the cost of centering, shuttering, finishing and reinforcement with:

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9588

9588.05

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.

-

-

-

... More
Using M.S. angles 40x40x6mm for diagonal braces.

1

5493

5493.9

... More
Using flats 30x6mm for diagonal braces and central cross piece.

1

5338

5338.5

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.

-

-

-

... More
M.S. tube

1

161

161.05

... More
E.R.W. tubes

1

154

154.7

... More
G.I. pipes

1

197

197.45

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters

-

-

-

... More
80x1.25 mm M.S. laths with 1.25 mm thick top cover

1

3305

3305

... More
Providing and fixing ball bearing for rolling shutters.

1

531

531.55

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.

-

-

-

... More
40mm thick with 20 mm nominal size stone aggregate.

1

510

510.29

... More
50 mm thick with 20mm nominal size stone aggregate.

1

562

562.15

... More
Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including skirting in vertical, rubbing, polishing and curing complete with:

-

-

-

... More
Makrana White Second quality (16mm)

1

3316

3316.05

... More
Extra for pre finished nosing to treads of steps of marble stone

1

553

553.7

... More
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 meter.

1

644

644.25

... More
Pointing on brick work in 1 cement : 3 sand mix. flush/ruled/structure or weathered pointing

1

200

200.8

... More
Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)

1

64

64.6

... More
With ready mixed aluminum primer of approved brand and manufacture on resinous wood and ply wood

1

61

61.4

... More
With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works

1

53

53.6

... More
With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work (second coat)

1

28

28.85

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc completeOn steel work

1

197

197.8

... More
On concrete work

1

199

199.1

... More
Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade

1

52

52.95

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer.

1

164

164.6

... More
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc.complete 125 mm

1

68

68

... More
100 mm

1

60

60

... More
Providing and fixing plained eaves boarding. 2nd class kail wood 250x32 mm (nominal size )

1

999

999.05

... More
300x40 mm (nominal size)

1

1453

1453.5

... More
Providing and fixing of 0.5mm Color GS Sheet Soffit boarding including Backing, supports etc complete job

1

600

600

... More
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick

1

138

138.1

... More
2 mm thick

1

181

181.05

... More
Providing and fixing G.I. pipes (B medium) complete with G.I. fittings excluding trenching and refilling etc. (external work)

-

-

-

... More
15 mm dia. nominal bore

1

206

206.5

... More
20 mm dia. nominal bore

1

255

255.2

... More
25 mm dia. nominal bore

1

339

339.25

... More
32 mm dia. nominal bore

1

411

411.3

... More
40 mm dia. nominal bore

1

489

489.25

... More
50 mm dia. nominal bore

1

805

805.7

... More
65 mm dia. nominal bore

1

1018

1018.05

... More
80 mm dia. nominal bore

1

1151

1151.2

... More
100 mm dia. nominal bore

1

1434

1434

... More
150 mm dia. nominal bore

1

2256

2256.9

... More
Carriage of material by mechnical means avg lead 20 km 150 mm dia

1

14

14.93

... More
Carriage of material by mechanical transport from Source to Dumping site Cement & Steel for an avg. lead of 20 kms

1

414

414.52

... More
Sand & 20 mm Aggrigates for an avg. lead of 40 kms.

1

466

466.28

... More
40 mm Aggrigates for an avg. lead of 30 kms

1

506

506.84

... More
Bricks for an avg. lead of 20 kms

1

1

1.24

... More
Carriage of material by manual means from Dumping site to actual site of work for an avg. lead of 250 mtrs. Cement

1

206

206.72

1

444

444

... More
Sand & 20 mm

1

420

420.84

... More
40 mm Aggrigates

1

454

454.95

... More
Bricks

1

-

0.78

... More
Electrical Items:Supplying and fixing of 25mm dia. medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

1

103

103.5

... More
Providing and carrying out wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl. cost of conduit)

1

824

824.55

... More
Providing and carrying out wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2-way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl cost of conduit)

1

1215

1215.55

... More
Providing and carrying out wiring for heating points with 4.0 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular combined S&S 16Amp along with modular plate, suitable GI box and earthing the point with 2 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl cost of conduit)

1

1300

1300

... More
Providing and carrying out circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (excl. cost of conduit) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire

1

192

192.05

... More
2 x 4 sq. mm + 1 x 4 sq. mm earth wire

1

230

230

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

1

569

569.25

... More
Supply and fixing of two module stepped type Electronic Fan regulator on the existing modular plate switch box including connections but excl cost modular plate etc., as required.

1

393

393.3

... More
Supplying and fixing single pole 5 A to 32 A rating, 240V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load in the MCB DB complete with connections, testing and commissioning etc. as required.

1

228

228.85

... More
Supplying and fixing double pole 63 Amp 240V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load in MCB DB complete with connections, testing and commissioning etc. as required.

1

442

442.75

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required

1

74

74.75

... More
Supply of 24-Watt LED slim aluminum panel surface type complete in all respects.

1

600

600

... More
Supply of 1200 mm sweep Ceiling Fans complete in all respects. Confirming to relevant Indian Standards

1

2125

2125

... More
Supply of 200 mm nominal sweep Exhaust Fans including shutter from outside complete.Confirming to relevant Indian Standards

1

1550

1550

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

1

193

193.2

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

1

196

196.65

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.

1

417

417.45

... More
Supplying and fixing 12-way double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

1

2360

2360.95

... More
Providing, fitting and testing of LED flood light IP65 30W rating to pre-wired electric points on the outside of the Filter House building.

1

1500

1500

... More
Providing and laying of armoured cable 95mm, 3.5 core for main service line of reputed make in P.V.C pipes of required dia to accommodate the service line including bends etc., from main transformer to the main panel board including copper thimbles, earth work excavation and filling for laying of cable complete.

1

325

325

... More
Providing and fitting at site 3-phase, Voltage stabilizer of following ratings, oil emersed, of standard make and quality including accessories as required. The job includes making of connections with main panel board and service line. To be paid in fitted and finished form after testing on full load capacity, complete job. 10 KVA

1

27000

27000

... More
20 KVA

1

37000

37000

... More
25 KVA

1

42000

42000

... More
30 KVA

1

47000

47000

... More
40 KVA

1

57000

57000

... More
50 KVA

1

67000

67000

... More
Providing and fitting of panel board with angle iron supports and A.C. sheets for fixing of MCCB, change over switch, bus bars etc. The job includes nuts bolts and embedding of supports in cement concrete blocks complete job.

1

4250

4250

... More
Providing and fitting of:

-

-

-

... More
200 Amp. 4 pole Change over of reputed make

1

11200

11200

... More
100 Amp 4 pole change over of reputed make.

1

7598

7598

... More
64 Amp. 4 pole Change over of reputed make

1

5000

5000

... More
32 Amp. 4 pole Change over of reputed make

1

2500

2500

... More
200 Amp 3-phase copper bus bar

1

7500

7500

... More
100 Amp-Copper bus bar

1

4550

4550

... More
64 Amp-Copper bus bar

1

3750

3750

... More
32 Amp-Copper bus bar

1

2850

2850

... More
100 Amp MCCB

1

3300

3300

... More
63 Amp MCCB

1

2700

2700

... More
40 Amp MCCB

1

2100

2100

... More
16 Amp MCCB

1

1250

1250

... More
6 Amp MCCB

1

630

630

... More
3-phase indicator points

1

445

445

... More
3-phase voltmeter and Amperemeters

1

1190

1190

... More
Providing and fitting of Fancy wall brackets and doom light of reputed make.

-

-

-

... More
Mechanical Items:Providing & fixing of PVC under drainage laterals with specifications conforming to IS-4985 & IS-15801, 8mm thick fabricated out of approved make with nominal dia of 9mm perforations as per design of bed provided at 60 degrees along with PVC Tees and end caps grouted in concrete, the pressure rating of 10kg/sq cm 50 mm dia

1

530

530

... More
62.5 mm dia

1

1110

1110

... More
75 mm dia

1

1420

1420

... More
100 mm dia

1

1990

1990

... More
Providing, fitting, testing and commissioning of following items for Flash Mixer: Mixing device with reduction gear system

1

2500

2500

... More
3-phase Electrically driven motor:

-

-

-

... More
0.5 HP

1

2800

2800

... More
0.75 HP

1

3400

3400

... More
1.0 HP

1

4800

4800

... More
Foundation \ Base plate

1

4548

4548

... More
Starter along with necessary wiring upto motor

1

1680

1680

... More
Providing, fitting, testing and commissioning of following itemn for Alum Dosing Unit- Mixing device with reduction gear system.

1

2500

2500

... More
3-phase electrically driven motors:

-

-

-

... More
0.5 HP

1

2800

2800

... More
0.75 HP

1

3400

3400

... More
1.0 HP

1

4800

4800

... More
Foundation / Base plate

1

4548

4548

... More
Starter along with necessary wiring upto motor

1

1680

1680

... More
P.V.C outlet, overflow system with fittings upto point of application

1

530

530

... More
150mm dia drain out let

1

1350

1350

... More
50 mm dia Service water piping.

1

530

530

... More
Constant dozing unit with time device

1

1500

1500

... More
Manually operated hoist

1

10000

10000

... More
Providing, fitting, testing and commissioning of following itemns for Chlorine Dosing Unit- Mixing device with reduction gear system.

1

2500

2500

... More
3-phase electrically driven motors:

-

-

-

... More
0.5 HP

1

2800

2800

... More
0.75 HP

1

3400

3400

... More
1.0 HP

1

4800

4800

... More
Foundation / Base plate.

1

4548

4548

... More
P.V.C outlet, overflow system with fittings upto point of application.

1

530

530

... More
Starter along with necessary wiring upto motor

1

1680

1680

... More
150 mm dia Drain out let

1

1350

1350

... More
50mm dia service water piping

1

530

530

... More
Constant dozing unit with time device.

1

1500

1500

... More
Providing fitting, testing and comissioning of air blower standard make ISI mark capable of providing compression @ 0.35 kgs/sqcm coupled with suitable 3 phase induction electric motor complete with auxiliary pipe system upto filter beds with pressure guage, Nozzles, foundation block, base plate, air check valve , non- return valve, Starter etc 2.10 KLPM Air blower with 2.0 HP Motor.

1

67500

67500

... More
4.2 KLPM Air blower with 5.0 HP Motor.

1

87500

87500

... More
8.2 KLPM Air blower with 7.5 HP Motor.

1

125000

125000

... More
10.6 KLPM Air blower with 10.0 HP Motor.

1

153400

153400

... More
12.3 KLPM Air blower with 12.50 HP Motor.

1

163400

163400

... More
16.80 KLPM Air blower with 15.0 HP Motor.

1

175400

175400

... More
Up Wash Arrangements

-

-

-

... More
Supply installation and successful testing and commissioning of mono block pumping unit standard make ISI mark coupled with 2 phase induction motor with appropriate pumping capacity so as to fill the tank within the max. of 2 hours with nominal dynamic head of 25m along with all accessories like foot valves, non- return valves, foundation block, base plate, suction pipe, suitable rising main with nominal dia 50mm (class-B) with heavey duty valves and other accessories required for the job. Pumping unit with 5.0 HP Motor.

1

20268

20268

... More
Pumping unit with 7.5 HP Motor.

1

29115

29115

... More
Pumping unit with 12.5 HP Motor.

1

46486

46486

... More
Pumping unit with 15.0 HP Motor.

1

49866

49866

... More
Central axle turn table with double bearing and guide for incoming cable.

1

4800

4800

... More
Peripheral drive assembly with following motors, gear box, rollers, drive trolly (60:1 reduction gear box). Pumping unit with 2.0 HP Motor.

1

19120

19120

... More
Pumping unit with 5.0 HP Motor.

1

24268

24268

... More
Pumping unit with 7.5 HP Motor.

1

33115

33115

... More
Starter along with necessary wiring upto motor

1

1680

1680

... More
Flocculator drive assembly with crown wheel, pinion sets, reduction gear (40:1) with motors complete job. 0.5 HP

1

5300

5300

... More
0.75 HP

1

5900

5900

... More
1.0 HP

1

7300

7300

... More
Incoming cable, telescopic electric pole with rotary current collector

1

6500

6500

... More
Providing and laying/fixing S&S Centrifugally Cast (Spun)/ Ductile Iron Pipes Class K-7 conforming to IS : 8329 100 mm dia

1

1108

1108.15

... More
150 mm dia

1

1581

1581.25

... More
200 mm dia

1

1947

1947

... More
250 mm dia

1

2504

2504.8

... More
300 mm dia

1

3129

3129.2

... More
350 mm dia

1

3707

3707

... More
400 mm dia

1

4440

4440.2

... More
450 mm dia

1

5378

5378.15

... More
Providing/ Fixing, installation, successful commissioning of double flanged MS pipes/specials to be fabricated from MS tube heavy quality nominal thickness 6mm, conforming to relevant Indian Standard IS-1239 and/or IS 1161 read with up to date amendments. The pipe material should be of standard quality and must withstand all the anticipated design pressure ratings.The work should be leakproof and should be painted with anti corrosive red oxide primer. Complete Job.

1

147

147

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete. Serrated with central bulb (225 mm wide, 8-11mm thick)

1

281

281.85

... More
Dumb bell with central bulb (180mm wide, 8mm thick)

1

228

228.3

... More
Kickers (320mm wide, 5mm thick)

1

261

261.75

... More
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage

1

547

547.6

... More
Providing & fixing of 0.63mm thick PGI sheets at construction joints including all leads and lifts complete job as directed by Engineer-in-charge

1

800

800

... More
Providing and fixing aluminum work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 andIS: 1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides withrequired EPDM rubber / neoprene gasket felt etc. Aluminum sectionsshall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading forglazing / panelling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-Charge (glazing,panelling and dash fasteners to be paid for separately.) Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)

1

459

459.31

... More
Powder coated aluminum (minimum thickness of powder coated 50 microns)

1

494

494.84

... More
Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns)

1

504

504.13

... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)

1

552

552.64

... More
Powder coated aluminum (minimum thickness of powder coated 50 microns)

1

588

588.89

... More
Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns)

1

598

598.35

... More
Preparation of subgrade by excavating earth to an average of 22.5 cm depth, dressing to camber and consolidation with road roller of 8-12 tonne capacity including making good the undulation etc. and disposal of surplus earth upto 50 meters.

1

153

153

... More
Supplying and stacking at site Graded crushed stone aggregate of size 90 mm to 45 mm

1

1204

1204.15

... More
53 mm to 22.4 mm

1

1204

1204.15

... More
Red Bajri

1

1204

1204.15

... More
13.2mm

1

1204

1204.15

... More
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.

1

768

768.15

... More
Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling (Payment for red bajri to be made separately):With roller

1

11

11.1

... More
Providing and applying tack coat using hot straight run bitumen of grade – VG-10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. 16.38.1 On W.B.M. @ 0.75 Kg/sqm.

1

74

74.35

... More
2.5 cm premix carpet surfacing with 2.25cum and 1.12 cum of stone chippings of 13.2 mm and 11.2mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively including a tack coat with hot straight run bitumen including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately).With paving Asphalt grade VG-30 with no solvent.

1

268

268.15

... More
SEAL COAT Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road all complete.

1

101

101.4

... More
Supply, Installation, Testing & Commissioning of Submersible Pumping Unit as per IS 8034 with following specification are as under: Tubewell Ist PUMP: Rated Discharge =15000 GPH Rated Head = 120 meters Overall Efficiency = Not less than 50% Speed = 2900 Rpm Type of pumping Equipment =Vertical Submersible MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel/Chrome Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel. MOTOR:- Method of starting = Star – Delta Speed = 3000 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 415 ± 15% V, 03 phase Efficiency = as per IS COde Rating = Not less than 50 HP/As per OEM Class of insulation = F/Suitable for above parameters Submersible motor should be water filled water lubricated squirrel cage type having capacity for above pumping parameters and working on 3 phases; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor filled water. a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length. b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of thickness (as per Table-17) at other end for column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing. The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site. Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. Manufactures Test Certificate to be appended

1

164640

164640

... More
Supply, Installation, Testing And Commissioning of G.I flanged Rising Main from tubewell to SR. The Pipe shall be hot dip Galvanized, class B (Medium) confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. The job includes nuts, bolts, gaskets etc as per site requirement. • Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-28. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. • Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. • Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) • Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The main technical specifications of the pipe are given here under: ND= 125 MM Class: B (Medium) Test/inspection certificates from the Manufacturer must be produced on delivery of the item

1

2485

2485

... More
Supply, Installation, Testing And Commissioning of Ductile Iron double flanged, non-rising spindle Resilient seated gate/ sluice valves (PN16) in accordance with BS 5163 part 1 and part 2 / EN 1074 Part 1 & 2 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. The Test Certificates of Sluice/Gate Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material Size : DN 125 Rating:- PN16

1

22321

22321

... More
Supply, Installation, Testing And Commissioning of Ductile Iron double flanged, Slanted seat swing check valve (NRV) (PN16) as per EN 1074- Part -3 / BS 5153. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. The Test Certificates of Check Valves (NRVs) mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material Size : DN 125 Rating:- PN16

1

26790

26790

... More
Fabrication ,Providing and fitting of 90-120 degree bend/elbow to be fabricated out of Class C GI pipe, 1 m length and flanged on both ends a to make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size : DN 125 Rating:- PN16

1

5142

5142

... More
Providing, Fabrication and fitting of Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. The Structural steel is to be utilized for Fabrication of DG set Shed, Gantry, Platform, Gravel Hooper and any other support required as per site requirement. The Steel may include ISMB, ISMC, ISA (Angle Iron), Chequered plate etc as per the site requirement. The drawings and Dimensions will be provided by Site In Charge at the time of execution of job

1

120

120.8

... More
Supply, Installation, Testing And Commissioning of manual type triple spur gear chain pulley block along with monorail geared travelling trolley having following features Gears: - The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain: - The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel: - The load chain well should be double ball bearing supported and Specially designed, perfectly machined wheel providing correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Capacity = 2 ton No. Of load chain falls = 2 or above Min. Height of lift = 6 M Suggested Make: Indeff/ Pull Lift Testing/Inspection Certificates are mandatory and are to be produced at the time of supply of material

1

44473

44473

... More
Supply, Installation, Testing And Commissioning of outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer (Level-2) Capacity:- 100 KVA Type of cooling: ONAN. Operating conditions: Input =11000 volts Output = 433 volts AC supply in 3- phase. Terminals: Input=3 No. HT Brass bush rods with insulators, washer, nuts etc. Output=4 No. LT Brass bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vent and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment.

1

209945

209945

... More
Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps. The job includes fitting of Channels on two poles for the installation of insulators and safety devices, GO Set, Lighting Arrestor etc. It also includes the channels for fitting of LT Meter and LT Distribution Box. The job includes P/F of GI channels at Tapping point for installation of GO Link Set, Pin Insulators Etc as per site requirement Size of Channel= ISMC 75X40MM

1

123

123

... More
Supply, Installation, Testing and commissioning of 02 No. Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT pole double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. The 11 KV AB switches shall conform to IS: 9920 (Part-I to IV). 01 No. GO Set is to be fitted at tapping point and 01 No at HT Transformer (Substation)

1

11730

11730

... More
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.

1

4983

4983

... More
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type.

1

7754

7754

... More
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm

1

342

342

... More
Supply, installation, erection, Testing And Commissioning of 9 mtrs long H.T Steel Tubular pole of specifications ST- 410 (SP-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. The tubular steel poles shall conform to the latest edition of Indian Standard specification IS: 2713 (Part – I, III): 1980 The materials used in construction of tubular steel poles shall be of the tested quality of steels of minimum tensile strength 540 MPa. The Poles shall be fitted with base plate as per above standard. The poles shall be applied with Red Oxide Primer and two coats of anti-corrosive Red paint at bottom up to the length of 4M and two coats of paint of silver shade for the rest.

1

20864

20864

... More
P/F of Galvanized nuts, bolts of various sizes as per site requirement.

1

142

142

... More
P/F Danger Plate with clamps on every HT pole

1

153

153

... More
Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices. The barbed wire shall be tightly close wrapped around the pole for 10-12 turns, commencing at 2.50m above the datum line.

1

136

136

... More
Providing and Fitting of PG Clamps

1

421

421

... More
Supply, Installation, Testing And Commissioning of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.

1

4922

4922

... More
Providing and fitting of ACSR as per IS 398 (part-2) 1996 ACSR (Galvanized steel reinforced) for fitment of various accessories size:- 0.3

1

37

37

... More
Supply, Installation, Testing And Commissioning of 50 sq mm XLPE HT cable (ABC type) of 11 KV Grade with following specifications size cross sectional area in square mm )= 3x50+1x70 sq mm phases Red, Yellow , Blue The Cable should conform to IS: 8130-1984, IS: 398(Part-IV)-1994, IS: 7098(Part-II)-2011 & IS: 5831-1984 with up to date amendments, if any. The Test Certificate of Cables duly stamped by manufacturer shall be provided at the time of supply of material

1

930

930

... More
Supply, Installation, Testing And Commissioning 11 KV cable termination kit for connecting 50 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer.

1

8994

8994

... More
Providing and fitting of Anchoring clamps comprising clamp body , plastic wedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 50 Sq. mm H.T AB Cable.

1

460

460

... More
Supply, Installation, Testing And Commissioning of LT Distribution box for H.T transformer with MCCB For incomer and SFU for outgoing circuits. The LT distribution Box is to be fitted on GI Channels. Capacity of transformer: 100 KVA

1

39422

39422

... More
Supply, Installation, Testing And Commissioning of PRODIGY LT Meter of following specification complete with all fixtures required for fitment at site Type: 3 Phase, 4 wire Measurements offered: KWh, KVARh, KVAh, KVA Voltage : 3x240V(415v),50HZ Ib : 40A Imax: 200A Battery: Lithium The Prodigy Meter must be fitted inside the Box, that is to be fitted on GI Channels near LT Distribution Box. Both the enclosures must be symmetrical Suggested Make: Secure/ L&T Sealing /Inspection report of Prodigy meter from JKPDCL (Concerned) is to be submitted by the firm at the time of charging of SUBSTATION.

1

28000

28000

... More
Supply, Installation, Testing And Commissioning of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER with current density of suitable rating for 200 Ampere. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards. b) Main Circuit Breaker (Incomer MCCB): Qty. = 01 No. of poles = 4 Pole Current Rating = 200A Rated operational voltage = 415 V ± 10 % Rated frequency = 50 ± 3%Hz Ambient temperature = -70C to 40 0C Type of release = Thermal-Magnetic Overload protection = 0.8 – 1×ln adjustable Short-circuit protection = 6-10×ln adjustable. Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50kA c) Change over Switch: Qty. = 01 No. Rating = 200A Type = Front operated, on load, 4 pole, 415 +10 %V, 50 + 3%Hz. d) Motor Back-up Protection MCCB: Qnty = 3 No No. of poles = 3P Current Rating = 160A Rated operational voltage = 415 V ± 10 % Rated frequency = 50 ± 3% Hz Ambient temperature = -70C to 40 0C Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50kA e. Submersible starters:-= Fully automatic star delta starters. Power Specs = 3 Ф, 415 ± 10 % V, 50 ± 3 % Hz. Relay range = 75-110 A Coil Voltage = 380 v Protection = single phasing , phase Reversal, phase unbalance (55 ± 5 V) , Conformity to standard = IS/IES 60947-4-1 Qty. = 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty. = 1 No. No. of poles = 4P Current Rating = 63A Rated operational voltage = 415 V ± 10 % Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36kA g) Motor Protection Relay:MM10/Siemens Digital Motor Protection Relay with LCD Display for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, Prolong starting, Locked Rotor & Earth fault. And over current Qty. = 02 No’s (01 No. for each starter) i) Over Voltage and Under Voltage Protection relay (02No.) to be fitted separately for both starters The panel shall be provided with phase indicators (03 N0) and digital ammeter of range 0-60 A, digital voltmeter of range 0-500 V, and digital frequency meter (01 No each). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and powder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements.

1

355811

355811

... More
Supply, Installation, Testing And Commissioning of 100 KVA voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage :180-400 volts.(3 phase) Output voltage : 415 ± 10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling : Naturally, Oil cooled (ONAN) Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion : virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications.

1

196466

196466

... More
Supply, Installation, Testing And Commissioning of XLPE, 1.1KV and 11KV grade Armored Aluminum Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. Suggested Make: L&T/ Polycab /Havells The Test Certificate of Cables duly stamped by manufacturer shall be provided at the time of supply of material i) 95 sqmm , 3.5core, LT cable

1

837

837

... More
ii) 10sqmm, 2 core, LT cable

1

162

162

... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below: Size :- 25 sqmm

1

1105

1105

... More
Supply, Installation, Testing And Commissioning of L.T, 70 sq mm 1 core PVC Insulated copper cable conforming to IS : 694 (2010) With latest amendments to be utilized for interconnection of various electrical gadgets . The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes laying of cable in cable tray Size :- 70 sqmm

1

1100

1100

... More
Supply, Installation, Testing And Commissioning perforated cable trays including horizontal and vertical bends, tees, cross members and other accessories as required and duly bolted to walls of building with Geyser bolts including Nuts and Washers etc

1

900

900

... More
Supply, Installation, Testing And Commissioning of earthing station for electric substation, LT panel, DG set and stabilizer comprising of company fabricated GI earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip (25x3mm) as per relevant standards. Safe earthing electrode size : 80 mm dia , Length : 2000 mm Back fill compound : 30 kg

1

10462

10462

... More
Supply, Installation, Testing And Commissioning of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate. The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO.

1

6447

6447

... More
Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structure at the top having 120˚ angle between arms and each arm having 15˚ inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code

1

22226

22226

... More
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.345 Having following specs: Input: 90-240 V 50 Hz Power Factor: 0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120˚ - 170˚ Lumens: 12000 Operating Temperature: -20˚C to 60˚C The LED is pressure die cast aluminium housing with power coated finish and having Ingress Protection up to IP-68. The LED is properly fitted on the arm of the pole and connected to the copper wire as provided in the high mast pole Suggested Make: Philips/Havells/Syska

1

9486

9486

... More
Supply, Installation, Testing And Commissioning of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes connecting the junction box to the main power supply from panel.

1

2227

2227

... More
Supply, Installation, Testing And Commissioning of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site in charge. The voltage stabilizer is to be connected to the heating and lighting circuit of the scheme including the street lights.

1

8154

8154

... More
Supply, installation, Testing & commissioning of 1100VA Full Sine wave hybrid inverter including Providing / Installation of 12V, 220AH solar Battery with trolley and cover. The job includes providing and fitting of 500 watt (01 No ) mono crystalline solar Panels along with required wiring for connecting solar to the inverter. the Job includes p/f of 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.

1

75000

75000

... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate.

1

1205

1205

... More
TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of : Providing of tool kit consists of following items ( Taparia /Bosch) i. Double ended Spanner (Chrome plated) 02 sets complete ii. Double ended Ring spanners chrome plated 02 sets complete iii. Allen key set black finish 02 sets complete iv. Combination Pliers insulated with thick C.A sleeve; size in mm 165, 210, 255 each – 02 No. v. Long nose pliers insulated with thick C.A sleeve; size in mm 165, 205 each – 02 No. vi. Side cutting pliers insulated with thick C.A sleeve; size in mm 165, 205 make – 02 No. vii. Insulated screw Drivers ( Taparia /Bosch) Blade length Blade dia. Tip dimensions Quantity 50 3 1.6 x 0.4 02 75 3 1.6 x0.4 02 100 3 3 x 0.4 02 125 3.5 3.5 x 0.5 02 150 3.5 3.5 x 0.5 02 200 4 4 x 0.6 02 300 5 5 x 0.8 02 viii. Hammer with handle weight – 110 mg, 340 gm , 600 gm –each – 1No. . ix. Heavy duty pipe Wrench length in mm - 200, 300, 600 each – 01 No. RIGID/IRWIN/Maxpower x. Electric Multi-meter =1No Make: Fluke /Klein xi. Digital Clamp tester capable to measure up to 400A - 1 No. Make: Fluke /Klein xii. Hack saw frame with hack saw blade – 01 no. xiii. S-16 MXL, S- 16 H X L Socket Set (19 sockets + 6 Accessories) – 01 No. Make: Taparia /Bosch Tool kit Make: Taparia /Bosch The tool kit is to be provided in tool box of Make: Taparia /Gear Wrench/ Stanley

1

28840

28840

... More
a) Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6'x3' (6Kg)- 02 No’s ii) Quilt with warm cover size 5'x8' (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks

1

39619

39619

... More
Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 3 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint

1

1655

1655.5

... More
Providing of CP 12 5WP solar/electrical lantern chargeable on both solar & electrical 220v supply. The solar lantern is to be provided with solar plate (provided in box with lantern)

1

1911

1911

... More
Supply of Gas Heater (2 in 1) operational on both Electric and LPG Supply. The gas heater shall have following specification:- 1. 3 Burner with ODS Function (Oxygen Depletion System) 2. 3 Electric heating rods 3. Versatile 2-in-1 design: Functions as an electric and gas LPG room heater The job includes Providing of 19kg Gas cylinder preferably Commercial with Regulator and 2 metre Gas pipe Suggested Makr:- Aygaz/Gazal/PADMINI

1

16000

16000

... More
Providing of 6.0 meter (20.0 ft) Foldable, portable & compact aluminum Telescopic Ladder, EN131 Certified., built from rust-proof, high-grade aluminum alloy and precise engineered HDPE components to ensure maximum corrosion resistance. It should be designed for use in all climatic and weather conditions and to enhance safety, and a strong grip even on wet surfaces. Ladder should be easy to extend and retract with storage straps, convenient to use, store and carry around. The length of step should be 40-50cm Approximately with distance of 40-50cm between steps.

1

19500

19500

... More
Providing of Industrial Rubber 11 KV Electrical Hand Shock Proof Safety Gloves for handling electrical equipments/connections.

1

750

750

... More
Providing and fitting of 02 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipment installed at site (01No.) and The name of water supply Scheme (01No) of appropriate sizes. The details, drawings and specifications will be provided by Site Incharge.

1

2687

2687.5

... More
Supply, Installation, Testing And Commissioning of OFF-Load (Side operated) Changeover Switch in Separate SS Enclosure as below Capacity:- 200Amp, 415V, 50hz Type: OFF Load Voltage : 415V No of Poles: 4 Operation: Side Operated Standard Conformity: IS / IEC: 60947 - 1&3

1

21000

21000

... More
Electrification of Pump House by way of P/F of 1.5 mm sq. multi strand PVC wire for lighting points (08Nos.) and 2.5 sq.mm for heating points (04Nos.) to be laid in PVC Conduit Pipes in slab and brick walls of Pump House /as per site requirement. Lighting points should be run on Inverter also. Providing and fitting of Modular type board comprising of 6A Switch =08 No’s, 5-Pin 6A socket =04 No’s, Indicator= 02 No’s , Fan dimmer = 01No, 3-Pin 16A Switch Socket Combine =04No’s, 12 watt Slim Round Conceal Ceiling type = 08 No’s, Ceiling Fan=01 No , Main Switch board with input and output arrangement etc. Suggested Make: L&T/Havells/Siemens/ Scheneider/GM/Anchor

1

30000

30000

... More
Providing, fitting, testing and commissioning of ARV (Air Release valve) (PN16) as per EN 1074 Part 4 to be fitted to G.I rising Main. The ARV Shall have the following specifications: - i. Valve type - single chamber, single orifice. ii. End connection - flanged ends to IS 1538 iii. Test pressure - body / seat 2.5 x PN iv. Sealing ring - EPDM v. Construction -ductile iron with stainless steel floats vi. Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. Size : DN 50 Rating:- PN16 Material of Construction • Body: Ductile iron EN-GJS-400-15 (GGG-40) • Bonnet: Ductile iron EN-GJS-400-15 (GGG-40) • Inner parts: Stainless steel 1.4541 • Float: Stainless steel A4 (exception: DN 50 - PN 10/16 synthetic, from PN 25 of A4) • Sealing: EPDM • Bonnet bolts: Stainless steel A4 (DIN EN ISO 3506) Suggested Make: AVK/ VAG/ Sigma Flow/ Talis The Test Certificates of Air Release Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material

1

19394

19394

... More
Supply installation, Testing & commissioning of 1.5 TR Capacity Wall mounted Split Air conditioners, 5 star rating inverter type fitted with hermitically sealed compressor operating on 220 ±10%, 50Hz single phase AC supply with evaporator and condensing unit made of copper tubes with aluminum fins , cordless remote control, copper piping for both suction and discharge of three(03) meters length with protection covering for piping, of suitable size of medium PVC pipe, power and control cabling as per site requirement, MS outdoor stand duly Painted, comprising of following etc complete as per requirement. a) Insulated copper pipe lines liquid and suction lines as per manufacturer recommendation. b) Flexible copper cable between indoor & outdoor Unit of suitable size as per Manufacturer recommendation. c) Drain Pipe d) Suitable size of PVC pipe for protective covering of refrigerant line. HITACHI/SAMSUNG/CARRIER/HAIER/LG/BLUE STAR/ DAIKIN/ MITSUBISHI*/VOLTAS*/

1

49500

49500

... More
supply and testing of 7.5 KVA Fully automatic Portable generator with following specifications Model:- EU70is (Honda) Max Output:- 7.0KVA Rated Voltage:- 230 Volts Start System:- Recoil / Electric Start Fuel Type:- Petrol Make:- HONDA Job includes Supplying of 20 ltrs petrol for testing of Equipment on full load

1

258000

258000

... More
Supply and testing of Weighing balance with MS Platform capable of measuring upto 200kg and operational on both battery and AC supply

1

9000

9000

... More
Operation and Maintainance of the Scheme for 05 years which includes change of filter media, checking of leakages, supply of chemicals, repairment/ replacement of Electro-Mechanical components complete job, etc. while as opertaion of the scheme shall start immediately after the completion of scheme , both O&M will be reckoned from the next day after the expiry date of DLP of the scheme.(the payment on a/c of O&M will be released upon succesfull and satisfactory operation and maintainance duly certified by the assessment committee constitued by the Superintending Engineer or executive Engineer which will furnish weekly deptt. by documentary evidence. If they fails to do it, no payment or reduced payment will be made to them as decided by the committee). for First Year

1

210000

210000

... More
second Year

1

315000

315000

... More
Third year

1

420000

420000

... More
Fourth year

1

525000

525000

... More
Fifth year

1

630000

630000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.