Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Road Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Nov 2024
Closing Date13 Dec 2024
Tender Amount₹ 2,31,92,245 
Notes
Download

Costs

Summary

Supply, Installation, Testing And Commissioning Of Electro Mechanical Works Required At Water Supply Scheme Aiims Awantipora (well No. 02 And Well No. 03) Of Jal Shakti (phe) Mechanical Division South Awantipora.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing/supplying and fitting of G.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode: DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts: Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets: Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The rising main is to be laid as per the instructions of the engineer in charge and site requirement. Size : DN 80 mm Class: C (Heavy)

1700

1485

2524500

... More
Size : DN 100 mm Class: C (Heavy)

360

2189

788040

... More
Size : DN 125 mm Class: C (Heavy)

800

2657

2125600

... More
Earth work in excavation by mechanical/manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. i. (in ordinary rock - 01 meter from cutting edge) by mechanical means.

650

493

320775

... More
ii. (in ordinary rock - 01 meter from cutting edge) by manual means.

250

924

231200

... More
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. i. (in ordinary rock - 01 meter from cutting edge)

25

940

23507.5

... More
Filling available excavated earth in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift upto 1.5m.

1116

218

243734.4

... More
Providing and laying of stone soling including manual compaction.

70

740

51800

... More
Centering and shuttering including strutting, propping etc. and removal of form work for: Foundation, footings, bases for columns.

350

286

100222.5

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

450

628

283027.5

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size).

180

6591

1186425

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1: 3 : 6 mix (1 cement , 3 coarse sand , 6 graded stone aggregate 20 mm nominal size).

70

5733

401352

... More
Providing and laying in position cement concrete of specified grade of reinforcement cement concrete including curing but excluding the cost of centring and shuttering, finishing and reinforcement all work upto plinth level with 1 : 1.5 : 3 mix (1 cement , 1.5 coarse sand , 3 graded stone aggregate 20 mm nominal size).

25

7788

194710

... More
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo mechanically treated bars of grade FE-500D or more.

4800

96

463440

... More
Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 80 mm.

4

1499

5996

... More
Fabrication, providing and fitting of long radius 90-120 degree bend/elbow to be fabricated out of G.I pipe, 1 m length and flanged on both ends a to make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size : DN 80 Class: C

30

2797

83910

... More
Size : DN 100 Class: C

10

3614

36140

... More
Size : DN 125 Class: C

3

5142

15426

... More
Cutting of hot dip galvanized G.I, pipe across the section by dint of pipe cutter/ gas cutter. The job also includes Providing and welding of M.S flanges to the two ends of pipe. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using Advani/Esab/L&T- SS Bond make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the pipe is given below: DN 80, Class-C.

30

1340

40200

... More
DN 100, Class-C.

10

1544

15440

... More
DN 125, Class-C.

4

1855

7420

... More
Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. Size: 80 mm Class: C class

1

4577

4577

... More
Size: 100 mm Class: C class

1

5122

5122

... More
Providing and fitting of Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 Nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. Size: DN 80 PN: 2.5/25

3

15497

46491

... More
Size: DN 100 PN: 1.6/16

3

19094

57282

... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions.It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work.The job includes providing and fitting of 02 Nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. Size: 80 mm PN: 1.6/16

4

17489

69956

... More
Size: 100 mm PN: 1.6/16

2

20581

41162

... More
Size: 125 mm PN: 2.5/25

1

29880

29880

... More
Providing, fitting, testing and commissioning of 50mm diameter ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: i. Valve type - single chamber, single orifice. ii. End connection - flanged ends to IS 1538 iii. Working temperature : - 20ᴼC to 45ᴼC iv. Test pressure - body / seat 2.5 x PN v. Sealing ring - EPDM vi. Construction - ductile iron with stainless steel floats vii. Coating - epoxy with corrosion resistance viii. Nominal pressure- PN 1.6/16 Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. The job also includes cutting of 50 mm dia hole in rising main and P/F of 50 mm dia. M.S Pipe one feet long with one end flanged perfectly adaptable to Flange of ARV and other end welded to 50 mm dia hole of rising main. Working Pressure : PN 1.6/16

1

19394

19394

... More
Working Pressure : PN 2.5/25

3

22750

68250

... More
Fabrication of platform to prevent the ingress of forign matter into the well and to bear the load of pumping unit, column pipes etc by way of providing and fitting of Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. The job involves following steel details: ii. In stringers, treads, landings etc of stair cases including use of chequered plate wherever required, all complete.

650

121

78650

... More
Fabrication of gantry mechanism /D.G Set shed/sleeping bed by way of providing Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded.

4500

111

499500

... More
Providing, installation and testing of manual type triple spur gear chain pulley block along with monorail geared travelling trolley having following features. Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported and Specially designed, perfectly machined wheel providing correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below: Make = Reputed make No. of load chain falls = 2 or above Min. Height of lift = 6 M Capacity = 3 ton

2

62972

125944

... More
Supply, installation, commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under -Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions: Input = 11000 volts Output = 433 volts AC supply in 3- phase. Terminals: Input = 3 No. HT bush rods with insulators, washer, nuts etc. Output= 4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. Rating: 250 KVA HT Transformer, 3 phase (Level 2) Copper Wound.

2

670548

1341096

... More
Providing and fitting G.I Channel /Angle/Flat of sizes including clamps.

800

123

98400

... More
Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings, operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs.

2

11730

23460

... More
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.

1

4983

4983

... More
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type.

1

7754

7754

... More
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creepage distance 320 mm

12

347

4164

... More
Supply, installation, errection of 9 mtrs long H.T pole of specifications ST- 410 (sp-33). The job further includes drilling of holes for installation of various accessories, wherever required. The job further includes GI wire earthing of pole as per REC standard.

40

20686

827440

... More
Providing and fixing of anti climbing devices with clamps.

40

421

16840

... More
Providing and fixing G.I Barbed wire for anti climbing.

120

136

16320

... More
Supply, Installation and Testing of 50 Sq mm XLPE Aluminum H.T cable (ABC type) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 with reinforced wire Phases: Red, Yellow, Blue

2000

903

1806000

... More
Painting of poles with Red oxide.

40

306

12240

... More
Painting of poles with Aluminum paint

40

510

20400

... More
P/F of Galvanized nuts, bolts of various sizes as per site requirement.

200

142

28400

... More
P/F Danger Plate with clamps.

40

153

6120

... More
Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mm ACSR (Galvanized steel reinforced) for fitment of various accessories.

60

56

3360

... More
Providing and fitting of Anchoring clamps comprising clamp body, plastic wedge, steel bill bracket, straps and buckles or nuts and bolts required for holding of 3 – Core, 50 Sq. mm H.T AB Cable.

40

457

18280

... More
P/F of 11 KV cable termination kit for connecting 50 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and 250 KVA HT transformer.

8

8994

71952

... More
Fabrication, Providing and fitting of Mug -30 Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER having size (10 mtrx (total length) .02 mtrx 0.003 mtr with current density of suitable rating for 100 Ampere. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards. b) Main Circuit Breaker (Incomer MCCB) Type : D-sine, DN2-250N Qty. = 02 No. No. of poles = 4 Pole Current Rating = 160-200 A Rated operational voltage = 415 V + 15 % Rated frequency = 50+/-3%Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50 KA Type of release = Thermal-magnectic Change over Switch: Qty. = 01 No. Rating = 100 A Type = Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz. d) Motor Back-up Protection MCCB: Type: D sine MCCB DN0-125 D Qnty = 2 No. No. of poles = 3P Current Rating = 100-125 A Rated operational voltage = 415 V +15 % Rated frequency = 50 + 3% Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36 KA type of release = thermal-magnetic f. Submersible starters:-= Fully automatic star delta/DOL starters. Capacity = MU-30 Relay Range = 30-50 A Power Specs = 3 Ф, 415 + 15% V, 50 + 3 % Hz. Relay range = As per requirement. Coil Voltage = 380 v Protection = Single phasing, phase Reversal, phase unbalance (55 ± 5 V) , Rated insulation voltage = 690V Terminal capacity = 120 Sq. mm with lug Or above Conformity to standard = IS/IES 60947-4-1 Qty. = 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB Qty. = 1 No. No. of poles = 4P Current Rating = 63 A Rated operational voltage = 415 V + 15 % Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 16 KA. g) Motor Protection Relay: Digital Motor Protection Relay with LCD Display for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, over current, Prolong starting, Locked Rotor, Under voltage, over voltage & Earth fault i. M-power module for mobile starter for submersible motor 1P/3P 3 wire IVRS Languages – English , Hindi, Suitable Region- North India The panel shall be provided with phase indicators (03 No.) and digital ammeter of range 0-200 A, digital voltmeter of range 0-500 V, and digital frequency meter (01 No. each). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and powder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements.

1

234576

234576

... More
Fabrication, Providing and fitting of MuG-50 Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER having size (10 mtrx (total length) .02 mtrx 0.003 mtr with current density of suitable rating for 200 Ampere. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards. b) Main Circuit Breaker (Incomer MCCB) Type : D-sine, DN2 250 N Qty. = 02 No. No. of poles = 4 Pole Current Rating = 160-200 A Rated operational voltage = 415 V + 15 % Rated frequency = 50+/-3%Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50 KA Type of release = Thermal-magnectic Change over Switch: Qty. = 01 No. Rating = 100 A Type = Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz. d) Motor Back-up Protection MCCB: Type: D sine MCCB DZ1-160 D Qnty = 2 No. No. of poles = 3P Current Rating = 84-125 A Rated operational voltage = 415 V +15 % Rated frequency = 50 + 3% Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36 KA Type of release = thermal-magnetic f. Submersible starters = Fully automatic star delta/DOL starters. Capacity = MU-G 50 Relay Range = 45-75A Power Specs = 3 Ф, 415 + 15% V, 50 + 3 % Hz. Relay range = As per requirement. Coil Voltage = 380 v Protection = Single phasing, phase Reversal, phase unbalance (55 ± 5 V) , Rated insulation voltage = 690V Terminal capacity = 120 Sq. mm with lug Or above Conformity to standard = IS/IES 60947-4-1 Qty. = 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB Qty. = 1 No. No. of poles = 4P Current Rating = 63 A Rated operational voltage = 415 V + 15 % Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 16 KA. g) Motor Protection Relay: Digital Motor Protection Relay with LCD Display for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, over current, Prolong starting, Locked Rotor, Under voltage, over voltage & Earth fault i. M-power module for mobile starter for submersible motor 1P/3P 3 wire IVRS Languages – English, Hindi, Suitable Region- North India The panel shall be provided with phase indicators (03 No.) and digital ammeter of range 0-200 A, digital voltmeter of range 0-500 V, and digital frequency meter (01 No. each). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and powder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements.

1

303186

303186

... More
Providing, fitting, testing and commissioning of voltage stabilizers as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling : Naturally, Oil cooledTemp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s).Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specification Rating : 50 KVA

4

107401

429604

... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical equipments. The cable connections terminal shall be fitted with copper thimbles of required size. Size : 16 sqmm

1500

711

1066500

... More
Size : 25 sqmm

1500

1105

1657500

... More
Providing and Fitting of 3 /3.5/2-Core, XLPE Armored Aluminum Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. i) 10 sqmm, 2 core, LT, 1.1 KV

750

162

121500

... More
ii) 95 sqmm, 3.5 core, LT, 1.1 KV

100

837

83700

... More
P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size : 80 mm dia, Length : 2000 mm Back fill compound : 30 kg

6

10462

62772

... More
Illumination of Premises:Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structures at the top having 120˚ angle between arms and each arm having 15˚ inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm.The pole is to be mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” ( cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code.

4

22226

88904

... More
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole. Having following specs: Input: 90-240 V 50 Hz Power Factor: 0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120˚ - 170˚ Lumens: 12000 Operating Temperature: -20˚C to 60˚C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is to be properly fitted on the arm of the pole and connected to the copper wire as directed.

16

9486

151776

... More
Providing, Installation and testing of 5KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge.

1

25300

25300

... More
Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Microtek/Luminous) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Amaron /Exide) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.

1

34053

34053

... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate.

10

1205

12050

... More
Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet, 2 Nos. including cutting, fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint.

36

140

5040

... More
Carriage of sand, stone aggregate by mechanical transport including loading, unloading and stacking (average distance-5km).

630

198

124777.8

... More
Carriage of soling stone by mechanical transport including loading, unloading and stacking (average distance-5km)

60

233

13980.6

... More
Carriage of cement/steel/CGI sheet and other heavy materials by mechanical transport including loading, unloading and stacking (average distance -25Km).

220

409

90024

... More
Providing and fitting of 11 KV polymeric Disc insulator 12KV, Min. Falling load 45 KN, Lighting impulse 75 KV Positive and 80 Kv Negative, Creepage distance 320 mm.

6

700

4200

... More
Providing and fitting of G.I earthing rod for earthing of H.T Poles as per REC Standard.

40

659

26360

... More
Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size as per Ministry of Environment protection rule 1986 read with latest amendments. The DG Set must to adhere to emmission standards set forth by the central pollution control board as per CPCB-4 norms. The DG set is required to be fitted and tested on load at site. Besides the above works the D.G set shall be provided with 12 V, 180 AH Lead acid battery of reputed make fitted inside the D.G set Canapy along with necessary accessories and battery charger of required capacity. The job also includes the cost on account of HSD and skilled operator required for operation of D.G set for a period of 10 hours continuously during its testing and commissioning of D.G set at site. the capacity of the D.G set is given below: Rating: 100 KVA, Water Cooled.

1

1475000

1475000

... More
Providing corrugated G.S Sheet roofing including vertical/ curved surface fixed with polymer coated J or L Hooks, bolts and nuts 8 mm dia. diameter with bitumen and G.I limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal /vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2.

60

974

58443

... More
Providing, cutting, fitting of welded wire fence with Square mesh -2 and 14 Gauge wire diameter to be fitted on all open vertical sides of the D.G Set shed. The job includes cutting, welding, hoisting etc as per site requirement. The job further include applying of one coat of primer red oxide and two coats of enamel paint over the fence.

1350

70

94500

... More
Construction of plate earthing by way of providing and fitting of following items Copper plate = 0.6 x0.6 x 0.003 m - 1 No. Copper strip = 25 x 2 mm and 20 m long - 1 No. PCC 1:2:4 Mix = 0.08 cum Shuttering = 0.36 sm Earth work 3.9 m deep = 3.159 cum Cast iron plate (lid) - 1 No. size 0.3 x0.3 m Funnel with wire mesh - 1 No. G.I Pipe C-Class - 2.85 m, 20 mm dia. Charcoal - as per requirement Salt = as per requirement The job also includes cost on account of testing of earthing by suitable instrument.

6

45000

270000

... More
Providing and fitting of DN 80, PN6 HDPE Pipe for laying of H.T/L.T cables under ground . The cable shall confirm to relivant I.S standard and the equipments required for installation of pipe is included in the Job.

2000

260

520000

... More
Steel work in built up section (round section) by way providing of fitting of 1000 mm diameter, 8 mm thick, M.S pipe to be laid across the AIIMS road. The job includes welding of M.S Pipe by DC Arc Welding using welding electrode having diameter not less than 4mm.

8000

121

968000

... More
Providing and fitting of prodigy LT Meter of following specification complete with all fixtures required for fitting at site for above mentioned scheme. Type : E3L 100, 3 Phase, 4-wire Measurements offered KWh, KVARh, KVAh, KVA Voltage: 2240 V (415 V) 50 Hz. Lb:40 A I max : 200A Battery : Lithium

1

28000

28000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.