Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date8 Nov 2024
Closing Soon26 Nov 2024
Tender Amount₹ 1,24,00,000 
Notes
Download

Costs

Summary

Construction Of 0.50 Lac Gallon Capacity Over Head Tank Jacketting Of Rectangular Collection Sump Construction Of Washroom Including Its Electric Works, Providing, Laying Fitting Of Gi Di Pipes And Pipe Specials Construction Of Pump House Above

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: 2.9.1 All kinds of soil :

1

256

256.85

... More
Providing and laying of dry stone soling in foundation/trenches hand packed and consolidated by hand ramming. (Subject to actual quantities during execution).

1

1320

1320

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: i. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

1

4826

4826.5

... More
ii. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

1

5202

5202.9

... More
iii. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1

5733

5733.6

... More
iv. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

1

6540

6540.45

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. i. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

7788

7788.4

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. i. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9395

9395.7

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with i. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9821

9821.85

... More
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: i. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

10377

10377.15

... More
Reinforced cement concrete work in chimneys, shafts upto floor five level including curing complete but excluding the cost of centering, shuttering, finishing and reinforcement with: i. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9588

9588.05

... More
Providing and laying upto floor v level reinforced cement concrete in kerbs, steps and the like including curing but excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9023

9023.35

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. i. All works upto plinth level.

1

8021

8021.1

... More
ii. All works above plinth level upto floor V level.

1

9412

9412.05

... More
Extra for R.C.C./B.M.C./R.M.C. work above floor V level for each four floors or part thereof.

1

280

280.95

... More
Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein at 5Qtl. Per Cum .

1

941

941

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately. i. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

1

98

98.8

... More
Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete mix, diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) By percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, i. 450 mm dia piles a. M-25

1

1941

1941.9

... More
b. M-30

1

1957

1957.55

... More
c. M-35

1

1973

1973.3

... More
ii. 500mm dia Piles a. M-25

1

2275

2275.5

... More
b. M-30

1

2294

2294.8

... More
c. M-35

1

2314

2314.25

... More
iii. 600mm dia Piles a. M-25

1

3095

3095.25

... More
b. M-30

1

3123

3123.1

... More
c. M-35

1

3151

3151.1

... More
iv. 750mm dia Piles a. M-25

1

4693

4693.95

... More
b. M-30

1

4737

4737.4

... More
c. M-35

1

4781

4781.1

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer-inCharge. i. Single pile upto 50 tonne safe capacity a. Initial test (Test Load 2.5 times the safe capacity)

1

159533

159533

... More
b. Routine test (Test Load 1.5 times the safe capacity)

1

175486

175486.6

... More
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.

1

167

167.8

... More
Open timbering in trenches including strutting and shoring complete (measurements to be taken of the face area timbered): i. Depth not exceeding 1.5 m.

1

127

127.1

... More
ii. Depth exceeding 1.5 m but not exceeding 3 m

1

134

134.45

... More
iii. Depth exceeding 3 m but not exceeding 4.50 m

1

146

146.55

... More
Centering and shuttering including strutting, propping etc. and removal of form for: i. Foundations, footings, bases of columns etc. for mass concrete.

1

286

286.35

... More
ii. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

1

628

628.95

... More
iii. Suspended floors, roofs, landings, balconies and access platforms.

1

718

718.2

... More
iv. Lintel, beams, plinth beams, girders, bressumers and cantilevers

1

577

577.55

... More
v. Columns, pillars, piers, abutments, posts and struts.

1

742

742.55

... More
vi. Stairs (excluding landings) except spiral staircases.

1

851

851.15

... More
vii. Spiral staircases (including landings)

1

676

676.25

... More
viii. Arches, domes, vaults upto 6 m span

1

2281

2281.2

... More
ix. Extra for arches, domes, vaults exceeding 6m span

1

1118

1118.85

... More
x. Chimney and shafts

1

628

628.95

... More
xi. Extra for shuttering in circular work (20% of respective centering and Shuttering items) Walls

1

125

125.79

... More
xii. Small surfaces such as cantilever ends, brackets and end of steps, caps and bases to pilasters and column and the like.

1

1027

1027.4

... More
xiii. Extra for shuttering in circular work (20% of respective centering and Shuttering items)

1

1027

1027.4

... More
xiv. Edges of slabs and breaks in floors and walls.

1

262

262.2

... More
xv. Edges of slabs and breaks in floors and walls a. Under 20 cm wide

1

262

262.2

... More
b. Above 20 cm wide

1

145

145.1

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). i. Suspended floors, roofs, landings, beams and balconies (plan area to be measured)

1

293

293.9

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level i. Thermo-Mechanically Treated bars of grade Fe-500D or more.

1

123

123.2

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete

1

120

120.8

... More
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. i. Welded

1

138

138.2

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. i. Hot finished welded type tubes

1

156

156.95

... More
ii. Hot finished seamless type tubes

1

171

171

... More
iii. Electric resistance or induction butt welded tubes

1

142

142.9

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. i. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete.

1

141

141.4

... More
ii. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

1

181

181.6

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. i. M.S. tube

1

161

161.05

... More
ii. E.R.W. tubes

1

154

154.7

... More
iii. G.I. pipes

1

197

197.45

... More
i. Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

1

706

706.5

... More
ii. Ridges Plain (500-600mm)

1

508

508.7

... More
Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. i. 0.50 mm thick with zinc coating not less than 275 gram/m2

1

690

690.85

... More
Providing and fixing plained eaves boarding. i. 2nd class kail wood (300x40 mm (nominal size).

1

1007

1007.5

... More
Providing and fixing of 0.5mm colour G.S Sheet Sofit boarding including Backing, Supports etc. Complete job.

1

600

600

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

1

218

218.4

... More
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete

1

1204

1204.5

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. i. 40mm thick with 20 mm nominal size stone aggregate

1

510

510.25

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : i. Cement mortar 1:6 ( 1 cement : 6 coarse sand)

1

7571

7571.55

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level.

1

1455

1455.65

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): i. Kiln seasoned and chemically treated hollock wood

1

74353

74353.45

... More
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. i. Kiln seasoned and chemically treated hollock wood (35mm thick)

1

3091

3091.7

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. i. Second Class kail wood

1

2305

2305.7

... More
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : i. Kiln seasoned and chemically treated hollock wood (35mm thick)

1

3086

3086.95

... More
Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : i. 5.0mm thick glass panes

1

1210

1210

... More
6mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand).

1

241

241.25

... More
12mm Cement plaster finished with a floating coat of neat cement of mix: i. 1 : 3 ( 1 cement : 3 fine sand)

1

370

370.75

... More
ii. 1 : 4 ( 1 cement : 4 fine sand)

1

353

353.1

... More
15mm Cement plaster on the rough side of single or half brick wall of mix: i. 1 : 4 ( 1 cement : 4 fine sand)

1

327

327.85

... More
ii. 1 : 6 ( 1 cement : 6 fine sand)

1

306

306.85

... More
Extra for plastering exterior walls of the height more than 10m from ground level for every additional height of 3m or part thereof.

1

71

71.55

... More
Extra for plastering i. Spherical Ceiling

1

141

141

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm).

1

98

98.75

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete. i. Serrated with central bulb (225 mm wide, 8- 11mm thick)

1

283

283.25

... More
Applying priming coat: i. With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)

1

64

64.6

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.

1

66

66.86

... More
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work

1

136

136.75

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. i. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

1

194

194.65

... More
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. i. 1 mm thick

1

138

138.1

... More
ii. 2 mm thick

1

181

181.05

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. i. Two coats

1

86

86.65

... More
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. i. New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

1

157

157.3

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete

1

1229

1229.1

... More
Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

1

1106

1106.05

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. s required. i. Upto 450mm Sweep

1

450

450

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. i. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.

1

5493

5493.25

... More
Providing and fixing C.P. brass bib cock of approved quality. i. 15 mm nominal bore (long nose).

1

334

334.7

... More
Providing and fixing gyser of capacity 25Ltr. Of quality make (Havells, Haquar, Crompton etc. including all required fittings and accessories complete Job).

1

8000

8000

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : i. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

1

4172

4172.4

... More
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.

1

129

129.1

... More
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

1

1474

1474.15

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

1

8

8.75

... More
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. i. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. a. PN-16 pipe , 25mm OD(SDR-7.4)

1

519

519.75

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : i. 100 mm inlet and 100 mm outlet a. Sand cast iron S and S as per IS:3989

1

1556

1556.4

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink: i. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.

1

596

596.3

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: i. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms

1

731

731.25

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : i. Kitchen sink with drain board 18.11.1.1 510x1040mm bowl depth 250mm

1

6166

6166.9

... More
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931

1

582

582.35

... More
Providing and fixing PTMT stop cock of approved quality and color. i. 15 mm nominal bore, 86 mm long, weighing not less than 88 gms.

1

203

203.55

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement)

1

63

63

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. i. Using M.S. angles 40x40x6mm for diagonal braces

1

5493

5493.9

... More
ii. Using flats 30x6mm for diagonal braces and central cross piece.

1

5338

5338.5

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. i. 80x0.90 mm M.S. laths with 0.90 mm thick top cove

1

2916

2916.1

... More
Providing and fixing ball bearing for rolling shutters.

1

531

531.55

... More
Supply, installation, testing and commissioning of Advanced Maintenance Free environment friendly earthing system consisting of 1 No. of 3 Mtr. Length 17.2mm dia UL certified earth electrode made of high tensile low carbon steel circular rods, molecularly bonded copper on outer surface (minimium copper bonding thickness – 250 microns) with GI terminals to connect incoming strips (Environment friendly backfill compound duly certified as per ANSI / NSF standard 60/Toxic content certificate as safe for use near potable ground water resources strictly as per specification enclosed. Make : Shree Electrodes / OBO Bettermann / Erico (2 No. UPS and 4 No. Main L.T Panel / 2 No. Fire Fighting Panel). i. Earth pit chamber (300mm x 300mm) with CI cover for the above.

1

15800

15800

... More
Providing and fixing of 25mm x 5mm Copper Strip in 40mm dia GI Pip FRL earth Electrode including connection with brass nut, bolt, spring, washer, excavation and refilling etc. as required.

1

1224

1224

... More
Supply, installation, testing and commissioning of lightening conductor made of 25mm dia 300mm long copper tube having single prong at top with nase plate

1

1500

1500

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1

207

207.35

... More
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : i. 250x10 mm

1

373

373.35

... More
ii.100x10mm

1

159

159.85

... More
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. i. 125 mm

1

68

68

... More
ii. 100 mm

1

60

60

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: i. 2nd class teak wood ( 50 x 12 mm).

1

214

214.75

... More
Providing and installing of PVC pipes (working pressure 4kg/cm2) single socketed pipe 110mm /80mm dia with all necessary arrangements and fittings including Tee’s, Elbows and End Caps wherever required complete job.

1

427

427

... More
Providing and fixing of 0.63mm thick PGI sheets at construction joints including all leads and lifts complete hob as directed by Engineer – Incharge.

1

800

800

... More
Providing and carrying out wiring for heating points with 4.0Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular combine S&S 16Amp along wit the modular plate, suitable GI box and erarthing the point with 2Sqmm FRLS PVC insulated copper conductor single core cable etc. As required (including the cost of conduit).

1

1400

1400

... More
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: i. 1:3:6 or richer mix (i/c equivalent design mix)

1

1725

1725.2

... More
ii. 1:4:8 or leaner mix (i/c equivalent design mix)

1

1064

1064.55

... More
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: i. In cement mortar

1

1458

1458.45

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : i. Of area of 3 sqm. and below

1

285

285.25

... More
ii. Of area beyond 3 sqm

1

390

390.5

... More
Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead : i. Of sectional area 40 sqcm. and above.

1

3488

3488.65

... More
ii. Of sectional area below 40 sqcm.

1

13

13.95

... More
Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 meters lead as per direction of Engineer-in-charge:

1

2

2.8

... More
Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 mtr. and lift upto 1.5 mtr. Complete.

1

125

125.35

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking the clods and mixing with sludge or manure in the ration of 8:1 (8 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of sludge or manure after reduction by 8 %), flooding with water, filling with the earth if necessary, watering and finally fine dressing, leveling etc. including stacking & disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 mtr. and lift upto 1.5 mtr. complete (cost of sludge, manure or extra earth to be paid for separately)

1

225

225.65

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) (Midium Class) i. 15 mm dia. nominal bore

1

206

206.5

... More
ii. 20 mm dia. nominal bore

1

225

225.2

... More
iii. 25 mm dia. nominal bore

1

339

339.25

... More
iv. 32 mm dia. nominal bore

1

411

411.3

... More
v. 40 mm dia. nominal bore

1

489

489.25

... More
vi. 50 mm dia. nominal bore

1

805

805.7

... More
vii. 65 mm dia. nominal bore

1

1018

1018.05

... More
viii. 80 mm dia. nominal bore

1

1151

1151.2

... More
ix. 100 mm dia. nominal bore

1

1434

1434

... More
x. 150 mm dia. nominal bore

1

2256

2256.9

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) i. 65 mm nominal bore

1

1646

1646.05

... More
Supply installation testing and commissioning of non returning valve. i. 65mm dia

1

4500

4500

... More
Providing, fabricating, fixing of M.S fittings viz bends of suitable degrees / size to be fabricated out of 8mm to 10mm thick MS. plate as per the requirement of site. This item includes cost of lead, spun yarn, R.I. cloth and lead caulking, lead beating with insertion of spun yarn etc. The fittings should be leak proof and should be painted with Anticorrosive Red Oxide Primer and incld. all carriages, leads lifts, etc. complete.

1

260

260

... More
Providing and fixing D.I. Slucie Valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately confirming to IS:14846 read with latest amendments. i. 65mm dia Class 1

1

17000

17000

... More
ii. 80mm dia Class 1

1

19000

19000

... More
iii. 100mm dia Class 1

1

20000

20000

... More
iv. 125mm dia Class 1

1

22000

22000

... More
v. 150mm dia Class 1

1

30000

30000

... More
vi. 200mm dia Class 1

1

40000

40000

... More
vii. 250mm dia Class 1

1

60000

60000

... More
viii. 300mm dia Class 1

1

80000

80000

... More
ix. 350mm dia Class 1

1

100000

100000

... More
Providing and laying flanged C.I. / D.I standard specials such as tees, bends, collars, tapers, caps etc ., suitable for flanged jointing as per IS : 1538 i. Up to 300 mm dia.

1

8539

8539.2

... More
ii. Over 300 mm dia.

1

8806

8806.75

... More
Providing, fixing of M.S flanges by welding including cost of cutting making both holes made out of 10/14mm thick M.S plate to the pipes of different dia’s and including cost of nuts, bolts, washers etc. (Complete Job). i. 65mm dia

1

900

900

... More
ii. 80mm dia

1

950

950

... More
iii. 100mm dia

1

1100

1100

... More
iv. 125mm dia

1

1200

1200

... More
v. 150mm dia

1

1300

1300

... More
vi. 200mm dia

1

1400

1400

... More
vii. 250mm dia

1

1800

1800

... More
Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : i. 75x63x3.2 mm

1

78

78.2

... More
ii. 100x63x4 mm

1

106

106.85

... More
Supplying and fixing of following modular switch / socket on the existing modular plate and switch box including connecitons but excluding modular plate etc. as required. i. 5/6A Switch

1

103

103

... More
ii. 3 Pin 5/6A Socket outlet 6Amp

1

122

122

... More
iii. 3 Pin 5/6A Socket outlet 16Amp

1

156

156

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. i. Made of G.I. wire of dia 4 mm

1

809

809.9

... More
Providing and fixing G.I. Pipes complete with G.I. fittings excluding trenching and refilling etc. (external work). i. Midium class double flanges with gasket 65mm dia nominal bore (GI Inlet Pipe from OHT to Collection Chamber).

1

1018

1018.05

... More
ii. Midium class double flanges with gasket 80mm dia nominal bore (GI Suction Pipe from Collection Chamber to borewell / tube well).).

1

1151

1151.2

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329 i. 100 mm dia Ductile Iron Double Flanged

1

1530

1530.6

... More
ii. 150 mm dia Ductile Iron Double Flanged

1

2295

2295.65

... More
Providing and laying D.I. Specials of Class K-12 suitable for mechanical jointing as oer IS:9523 i. Upto 600mm dia.

1

17971

17971.65

... More
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.

1

2516

2516.85

... More
Steel reinforcement for R.C.C. work ready to use "cut and bend"rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. i. Thermo-Mechanically Treated bars of grade Fe-500D or more

1

116

116.25

... More
Providing and fixing ventilator of size 450mm x 450mm made out of angle iron 40mm x 40mm with wire mesh of 25mm x 25mm size including welding charges and including all carriages upto site of work.

1

1500

1500

... More
Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete

1

346

346.7

... More
Providing and fixing aluminum round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-charge i. Anodized (AC 15) aluminum

1

89

89.15

... More
Providing and installing 8W Round Led Ceiling Light Complete Job.

1

250

250

... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil :

1

91

91.75

... More
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : i. 150x10 mm

1

83

83.8

... More
ii. 200x10 mm

1

95

95.35

... More
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge : i. Above 40 mm nominal bore

1

121

121.65

... More
Carriage of material by mechanical transport including loading, unloading, stacking of material. B. Sand i. For an avg. lead of 3Kms.

1

165

165.84

... More
ii. For an avg. lead of 4Kms.

1

183

183.58

... More
iii. For an avg. lead of 5Kms.

1

200

200.74

... More
iv. Beyond 5Kms upto 10Kms per Km

1

15

15.66

... More
v. Beyond 10Kms upto 20Kms per Km

1

13

13.09

... More
vi. Beyond 20Kms per additional Km

1

11

11.04

... More
C. Aggregate below 40mm i. For an avg. lead of 3Kms.

1

165

165.84

... More
ii. For an avg. lead of 4Kms.

1

183

183.58

... More
iii. For an avg. lead of 5Kms.

1

200

200.74

... More
iv. Beyond 5Kms upto 10Kms per Km

1

15

15.66

... More
v. Beyond 10Kms upto 20Kms per Km

1

13

13.09

... More
vi. Beyond 20Kms per additional Km

1

11

11.04

... More
D. Aggregate above 40mm i. For an avg. lead of 3Kms.

1

180

180.26

... More
ii. For an avg. lead of 4Kms.

1

199

199.55

... More
iii. For an avg. lead of 5Kms.

1

218

218.19

... More
iv. Beyond 5Kms upto 10Kms per Km

1

17

17.03

... More
v. Beyond 10Kms upto 20Kms per Km

1

14

14.23

... More
vi. Beyond 20Kms per additional Km

1

12

12

... More
E. Stone Soling: i. For an avg. lead of 3Kms.

1

195

195.1

... More
ii. For an avg. lead of 4Kms.

1

215

215.98

... More
iii. For an avg. lead of 5Kms.

1

236

236.16

... More
iv. Beyond 5Kms upto 10Kms per Km

1

18

18.43

... More
v. Beyond 10Kms upto 20Kms per Km

1

15

15.4

... More
vi. Beyond 20Kms per additional Km

1

12

12.98

... More
F. Steel / CGI Sheets: i. For an avg. lead of 3Kms.

1

147

147.41

... More
ii. For an avg. lead of 4Kms.

1

163

163.19

... More
iii. For an avg. lead of 5Kms.

1

178

178.43

... More
iv. Beyond 5Kms upto 10Kms per Km

1

13

13.92

... More
v. Beyond 10Kms upto 20Kms per Km

1

11

11.63

... More
vi. Beyond 20Kms per additional Km

1

9

9.81

... More
G. Earth: i. For an avg. lead of 3Kms.

1

207

207.3

... More
ii. For an avg. lead of 4Kms.

1

229

229.48

... More
iii. For an avg. lead of 5Kms.

1

250

250.92

... More
iv. Beyond 5Kms upto 10Kms per Km

1

19

19.58

... More
v. Beyond 10Kms upto 20Kms per Km

1

16

16.36

... More
vi. Beyond 20Kms per additional Km

1

13

13.8

... More
H. Cement: i. For an avg. lead of 3Kms.

1

147

147.41

... More
ii. For an avg. lead of 4Kms.

1

163

163.19

... More
iii. For an avg. lead of 5Kms.

1

178

178.43

... More
iv. Beyond 5Kms upto 10Kms per Km

1

13

13.92

... More
v. Beyond 10Kms upto 20Kms per Km

1

11

11.63

... More
vi. Beyond 20Kms per additional Km

1

9

9.81

... More
I. Sand: i. For an avg. lead of 50Mtr.

1

200

200.67

... More
ii. Beyond Ist 50Mtr.

1

43

43.69

... More
J. Aggregate below 40mm: i. For an avg. lead of 50Mtr.

1

200

200.67

... More
ii. Beyond Ist 50Mtr.

1

43

43.69

... More
K. Aggregate below 40mm and above: i. For an avg. lead of 50Mtr.

1

216

216.94

... More
ii. Beyond Ist 50Mtr.

1

47

47.23

... More
L. Stone Soling: i. For an avg. lead of 50Mtr.

1

263

263.08

... More
ii. Beyond Ist 50Mtr.

1

51

51.4

... More
M. Steel / CGI Sheets: i. For an avg. lead of 50Mtr.

1

249

249.61

... More
ii. Beyond Ist 50Mtr.

1

36

36.63

... More
N. Earth: i. For an avg. lead of 50Mtr.

1

200

200.67

... More
ii. Beyond Ist 50Mtr.

1

43

43.69

... More
O. Cement: i. For an avg. lead of 50Mtr.

1

116

116.22

... More
ii. Beyond Ist 50Mtr.

1

17

17.05

... More
Mechanical / Electrical Part Supply, installation, testing and commissioning of Horizontal pumping unit as per IS 1520 with following specification:- Pump:- Discharge: 29000 LPH Dynamic Head: 36 Meters 1.Type :- Horizontal Split casing Material of construction 1.Impeller:- Stainless Steel/ Bronze/ CF8M 2.Shaft:- SS410 3.Pump casing:- Cast Iron 4. Speed :- 2900 rpm The pump shall confirm to IS-1520 code MOTOR :- A) Type :- Horizontal squirrel cage Induction Type B) Rating:- Suitable for above parameters/As per OEM C) No of phases: 3 phase 415 V±10%,50Hz ± 3%, AC supply D) Winding:-Copper wound squirrel cage E) Type of enclosure:-TEFC F) Method of cooling: Air cooled with fan mounted G) Method of Starting: star delta The pumping unit should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pumping equipment is to be installed on the concrete foundation base with J Bolts. Job includes testing and commissioning of pumping unit on full load at site. Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate and Material of Construction from the Manufacturer must be produced on delivery of the item

1

117968

117968

... More
Providing/supplying and fitting of G.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. The job includes Providing and fitting of 90-120 degree bend/elbows to be fabricated out of Class C GI pipes flanged on both ends a to make it leak proof Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode: DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts of required size. Rubber Insertion Gaskets: Rubber Insertion Gaskets to be used between flanged joints. The main technical specifications of the pipe are given here under: ND= 65 mm Class: C (Heavy)

1

1214

1214

... More
Providing/supplying and fitting of GI flanged suction and delivery pipe in lengths of 1m/2m at site. The Pipe shall be Class- C confirming to relevant IS Code. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) The job includes the cost on account of P/F of nuts, bolts and gasket required for the job The job includes Providing and fitting of 90-120 degree bend/elbows to be fabricated out of Class C GI pipes flanged on both ends a to make it leak proof Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. ND= 80 mm Class: C (Heavy

1

1485

1485

... More
Fabrication, providing and fitting of washout Tee. The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. The size of the Tee is given Below: ND= 65 MM Class: C (Heavy)

1

4577

4577

... More
Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Size: DN 65 mm PN:1.6/16 The Test Certificate of sluice Valves duly stamped by manufacturer shall be provided at the time of supply of material,

1

13330

13330

... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Size: DN 65 mm PN:1.6/16 The Test Certificate of NRV s duly stamped by manufacturer shall be provided at the time of supply of material

1

15153

15153

... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Size: DN 80 mm PN:1.6/16 The Test Certificate of NRV s duly stamped by manufacturer shall be provided at the time of supply of material

1

17489

17489

... More
Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to risingMain. The ARV Shall have the following specifications: - i. Valve type - single chamber, single orifice. ii. End connection - flanged ends to IS 1538 iii. Working temperature - 70℃ to 55 c iv. Test pressure - body / seat 2.5 x PN v. Sealing ring - EPDM vi. Construction -ductile iron with stainless steel floats vii. Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. Size: 50mm PN: 1.6/16 The Test Certificate of ARV duly stamped by manufacturer shall be provided at the time of supply of material

1

19394

19394

... More
Supply, Installation, Testing And Commissioning of 25 KVA voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage :180-400 volts.(3 phase) Output voltage : 415 ± 10% volts. Frequency : 50 ±3 C/S. Windings: Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling : Naturally, Oil cooled (ONAN) Temp. Rise (Max):30°C above ambient Mounting :On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion :virtually nil Duty cycle : 100% continuous Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications.

1

58940

58940

... More
Supply, Installation, Testing And Commissioning of OFF-Load (Side operated) Changeover Switch in Separate SS Enclosure as below Capacity:- 200 Amp, 415V, 50hz Type: OFF Load Voltage : 415V No of Poles: 4 Operation: Side Operated Standard Conformity: IS / IEC: 60947 - 1&3

1

19000

19000

... More
Supply, Installation, Testing And Commissioning of 25 KVA outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer (Level-2) Type of cooling: ONAN. Operating conditions: Input =11000 volts Output = 433 volts AC supply in 3- phase. Terminals: Input=3 No. HT Brass bush rods with insulators, washer, nuts etc. Output=4 No. LT Brass bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vent and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate.

1

74442

74442

... More
Supply, installation, erection of 9 mtrs long H.T pole of specifications ST- 410 (SP-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. The tubular steel poles shall conform to the latest edition of Indian Standard specification IS: 2713 (Part – I, III): 1980 The materials used in construction of tubular steel poles shall be of the tested quality of steels of minimum tensile strength 540 MPa. The Poles shall be fitted with base plate as per above standard. The poles shall be applied with Red Oxide Primer and two coats of anti-corrosive Red paint at bottom up to the length of 4M and two coats of paint of silver shade for the rest.

1

20686

20686

... More
Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps and other allied items. The job includes fitting of Channels on two poles for the installation of insulators and safety devices, GO Set, Lighting Arrestor etc. It also includes the channels for fitting of LT Meter and LT Distribution Box. The job includes P/F of GI channels at Tapping point for installation of GO Link Set, Pin Insulators Etc as per site requirement

1

140

140

... More
Supply, Installation, Testing and commissioning of 02 No. Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT pole double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. The 11 KV AB switches shall conform to IS: 9920 (Part-I to IV). 01 No. GO Set is to be fitted at tapping point and 01 No at HT Transformer (Substation)

1

11730

11730

... More
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.

1

4983

4983

... More
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type.

1

7754

7754

... More
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm

1

347

347

... More
P/F of Galvanized nuts, bolts of various sizes as per site requirement

1

140

140

... More
P/F Danger Plate with clamps

1

150

150

... More
Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices. The barbed wire shall be tightly close wrapped around the pole for 10-12 turns, commencing at 2.50m above the datum line.

1

140

140

... More
P/L of ACSR conductor of size 0.03 as per the relevant IS standard.

1

37

37

... More
Supply, Installation, Testing And Commissioning of 35 sq mm XLPE HT cable (ABC type) of 11 KV Grade with following specifications size cross sectional area in square mm )= 3x35 sq mm including messenger wire phases Red, Yellow , Blue The Cable should conform to IS: 8130-1984, IS: 398(Part- IV)-1994, IS: 7098(Part-II)-2011 & IS: 5831-1984 with up to date amendments, if any.

1

818

818

... More
Supply, Installation, Testing And Commissioning 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer.

1

8994

8994

... More
Supply, Installation, Testing And Commissioning of LT Distribution box for H.T transformer with MCCB For incomer and SFU for outgoing circuits. The LT distribution Box is to be fitted on GI Channels.

1

28118

28118

... More
Supply, Installation, Testing And Commissioning of PRODIGY LT Meter of following specification complete with all fixtures required for fitment at site Type: E3L100, 3 Phase, 4 wire Measurements offered: KWh, KVARh, KVAh, KVA Voltage : 3x240V(415v),50HZ Ib : 40A Imax: 200A Battery: Lithium The Prodigy Meter must be fitted inside the Box, that is to be fitted on GI Channels near LT Distribution Box. Both the enclosures must be symmetrical Sealing /Inspection report of Prodigy meter from JKPDCL (Concerned) is to be submitted by the firm at the time of charging of SUBSTATION.

1

29000

29000

... More
Modular motor control Panel Supply, Installation, Testing And Commissioning of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER with current density of suitable rating for 160 Ampere. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards. b) Main Circuit Breaker (Incomer MCCB): Qty. = 02 No. of poles = 4 Pole Current Rating = 160A Rated operational voltage = 415 V ± 10 % Rated frequency = 50 ± 3%Hz Ambient temperature = -70C to 40 0C Type of release = Thermal-Magnetic Overload protection = 0.8 – 1×ln adjustable Short-circuit protection = 6-10×ln adjustable. Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50kA c) Change over Switch: Qty. = 01 No. Rating = 160A Type = Front operated, on load, 4 pole, 415 +10 %V, 50 + 3%Hz. d) Motor Back-up Protection MCCB: Qnty = 2 No No. of poles = 3P Current Rating = 100A Rated operational voltage = 415 V ± 10 % Rated frequency = 50 ± 3% Hz Ambient temperature = -70C to 40 0C Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50kA e. Starters:-= Fully automatic star delta starters. Power Specs = 3 Ф, 415 ± 10 % V, 50 ± 3 % Hz. Relay range = 13-22 A Coil Voltage = 380 v Protection = single phasing , phase Reversal, phase unbalance (55 ± 5 V) , Conformity to standard = IS/IES 60947-4-1 Qty. = 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty. = 1 No. No. of poles = 4P Current Rating = 63A Rated operational voltage = 415 V ± 10 % Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36kA g) Motor Protection Relay: Digital Motor Protection Relay with LCD Display for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, Prolong starting, Locked Rotor & Earth fault. And over current Qty. = 03 No’s (01 No. for each starter) h) M-power module for mobile starter for motor 1P/3P 3 wire Quantity – 03 no. IVRS Languages – English , Hindi, Suitable Region- North India i) Over Voltage and Under Voltage Protection relay (02No.) to be fitted separately for each starter The panel shall be provided with phase indicators (03 N0) and digital ammeter of range 0-60 A, digital voltmeter of range 0-500 V, and digital frequency meter (01 No each). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and poder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements.

1

178199

178199

... More
Providing and Fitting of 3.5 Core, XLPE, 1.1KV grade Armored LT Aluminum Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer/AVR to control panel including necessary thimbling, crimping, taping etc. i. 35 Sq mm, 3.5 core LT cable

1

380

380

... More
10 sqmm, 2 core, LT cable

1

162

168

... More
Providing and fitting of 10 sq mm single core copper cable for interconnecting various electrical gadets as per IS 694: 2010 along with thimbling as per requirement. The job includes laying of cable in cable tray wherever necessary.

1

148

148

... More
Supply, Installation, Testing And Commissioning perforated cable trays including horizontal and vertical bends, tees, cross members and other accessories as required and duly bolted to walls of building with Geyser bolts including Nuts and Washers etc Size= 150x50x1.6mm

1

900

900

... More
Supply, Installation of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size : 80 mm dia , Length : 2000 mm Back fill compound : 30 kg

1

10462

10462

... More
Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 01) 01 No MCB 16 Amp, 2 pole The job includes fabrication, providing and fitting of single arm GI structure at the top having 15˚ inclination with respect to horizontal plane. Arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code

1

22226

22226

... More
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole , having following specs:, Input: 90-240 V 50 Hz, Power Factor: 0.9 Colour Temperature: 4K - 6.5K, Beam Angle: 120˚ - 170˚, Lumens: 12000, Operating Temperature: -20˚C to 60˚C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection not less than IP-66 The LED is properly fitted on the arm of the pole and connected to the copper wire as provided in the high mast pole

1

9486

9486

... More
Supply, Installation, Testing And Commissioning of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes connecting the junction box to the main power supply from panel.

1

2227

2227

... More
Supply, Installation, Testing And Commissioning of 5KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site in charge. The voltage stabilizer is to be connected to the heating and lighting circuit of the scheme including the street lights.

1

13500

13500

... More
Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along with other accessories like SS- Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.

1

34053

34053

... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5 mm Size: - 1M wide

1

1205

1205

... More
TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of : Providing of tool kit consists of following items ( Taparia /Bosch) i. Double ended Spanner (Chrome plated) 02 sets complete ii. Double ended Ring spanners chrome plated 02 sets complete iii. Allen key set black finish 02 sets complete iv. Combination Pliers insulated with thick C.A sleeve; size in mm 165, 210, 255 each – 02 No. v. Long nose pliers insulated with thick C.A sleeve; size in mm 165, 205 each – 02 No. vi. Side cutting pliers insulated with thick C.A sleeve; size in mm 165, 205 make – 02 No. vii. Insulated screw Drivers ( Taparia /Bosch) Blade length Blade dia. Tip dimensions Quantity 50 3 1.6 x 0.4 02 75 3 1.6 x0.4 02 100 3 3 x 0.4 02 125 3.5 3.5 x 0.5 02 150 3.5 3.5 x 0.5 02 200 4 4 x 0.6 02 300 5 5 x 0.8 02 viii. Hammer with handle weight – 110 mg, 340 gm , 600 gm –each – 1No. ix. Heavy duty pipe Wrench length in mm - 200, 300, 600 each – 01 No. x. Electric Multi-meter =1No xi. Digital Clamp tester capable to measure up to 400A - 1 No. xii. Hack saw frame with hack saw blade – 01 no xiii. S-16 MXL, S- 16 H X L Socket Set (19 sockets + 6 Accessories) – 01 No. The tool kit is to be provided in tool box of Make: Taparia /Gear Wrench/ Stanley

1

28840

28840

... More
Fabrication of 7’ (L) x 6’(B) x 1.5' (H) angle iron bed for operators with back-height of 2 feet by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded

1

140

140

... More
Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 3 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint

1

154

154

... More
a) Providing of good quality bedding for night stay/Shift consisting of: i) Mattress with warm cover size 6'x3' (6Kg)- 02 No’s ii) Quilt with warm cover size 5'x8' (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 no., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, Induction cook top. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks

1

39619

39619

... More
Providing of 6.0 meter (20.0 ft) Foldable, portable & compact aluminum Telescopic Ladder, EN131 Certified., built from rust- proof, high-grade aluminum alloy and precise engineered HDPE components to ensure maximum corrosion resistance. It should be designed for use in all climatic and weather conditions and to enhance safety, and a strong grip even on wet surfaces. Ladder should be easy to extend and retract with storage straps, convenient to use, store and carry around. The length of step should be 40-50cm Approximately with distance of 40-50cm between steps.

1

19500

19500

... More
Providing of Industrial Rubber 11 KV Electrical Hand Shock Proof Safety Gloves for handling electrical equipments/connections.

1

750

750

... More
Providing, installation, testing and commissioning of ‘Silent type” AIR COOLED Diesel Generator set of 25.00 KVA Rating and 3 Phase. The DG Set shall be able to operate at (1600 meters ASL) efficiently without causing any malfunctioning. The DG Set shall comprise of Diesel Engine and Alternator coupled together with heavy duty flexible coupling and mounted on M. S. Base Frame along with all standard accessories, Control Panel, Battery, M. S. Canopy, duly painted and conforming to noise reduction norms as per environmental protection rules 1986 as laid down by Ministry of Environmental (Protection) and Forest, read with GSR-371(E) Dated:17-05-2002 at S. No. 95 for emissions limits and GSR-371(E) Dated:17-05-2002 at S. No. 94 (Paragraph 1 and 3) for noise limits for the DG Set and as per the latest amendments if any. The engine shall conform to IS: 10000/BS: 649/BS: 5514 amended up to date. The DG Set should be rated for continuous duty with overload provision of 10% for the period not exceeding one hour in twelve hours. A) ALTERNATOR:- The alternator shall be self-excited, self-regulated for 25KVA rating and shall be brushless, continuous duty. The alternator shall be screen protected drip proof enclosure, and horizontal foot mounted in double bearing construction. The alternator shall conform to IS-4722 / IEC-34/BS2613 a) Rated Output : 25 KVA (At 1600mtrs ASL) b) Rated Speed : 1500 RPM c) Efficiency at full load 0.8 P.f. = Not less than 86.00% or as per relevant IS code. d) total distortion factor = less than 3% e) Voltage : 415 V at 50 Hz f) Class of Insulation : H g) Enclosure: IP 23. h) Governor = Electronic Standards: The alternators shall be in accordance with the following standards as are applicable a. IS-4722/IS-2613:1970. The performance of rotating electrical machines. b. IS-4889/BS 269 rules for method of declaring of efficiency of electrical machines. B). DIESEL ENGINE (Prime Mover) The Prime Mover shall be diesel driven to develop requisite BHP as per ISO-8528-part- I at 1500 RPM for the alternator rated as above with ambient temperature ranging from -10C to +45C with 70% humidity. a) Speed :1500 RPM c) Cooling System : Water cooled d) Method of Start: Electric Start with a Key. e) Rated BHP : Suitable for 25.00 KVA rating output at 1800mtrs ASL as per ISO-8528-part- I The engine shall be fitted with following accessories:- 1) Fuel Tank: The capacity of the fuel tank shall be so as to last for 12 hours of continuous running on full load. The fuel tank shall be mounted on an angle iron frame of suitable height and fabricated out of M.S. Sheet of 4 mm Thickness duly painted and fitted with connections for inlet, outlet and return and also to be provided with air vent, drain with valve, level indicator and fuel pipes complete in all respects. 2) Battery: Battery suitable for above capacity DG set. 3) Starting System Providing and Fitting of Terminals, Leads, C/W Charging Dynamo and fitted with 12 Volt Starting System. The system shall be able of starting of DG set with 20-30 Sec even in winter conditions with ambient temp down to -50C 4) Engine Instrument Panel: The Engine Instrument Panel shall be fitted with starting switch with keys, Lube Oil Gauge, Temperature & Pressure Gauge, Speedometer, Kilowatt Hour Meter etc and all other accessories as required. 5) Safety Control: The D. G. Set shall be provided & fitted with all the safety controls i.e. for Low lube oil Pressure indication switch, High water temperature indication, RPM indication, water temperature indication, battery charging indication etc. C. Standard Control Panel: The Control Panel shall be fabricated out of steel sheet 1.5 mm thick duly pre-treated and aesthetically finished. It shall be totally enclosed, dust, vermin proof with IP-53 degree of protection as per IS 2147-62. The panel shall consist of following instruments: a) 0 – 600 V, AC Voltmeter of class 1.5 accuracy with phase selector switch b) A.C. Ammeter of Class 1.5 accuracy. c) HRC Fuses of required rating. d) One No MCCB of required rating. e) Frequency Meter. f) Power factor meter. g) Pilot Lamps h) Energy Metre i) Push Button Switch for ON-OFF operation. All the above components shall be properly mounted duly wired and shall be of reputed make. D) Canopy: The Canopy of the D. G. Set shall be fabricated out of M. S. Sheet of required gauge so as to withstand the snow load etc, duly painted. The Canopy shall be as per the Norms of the as laid down in the environmental protection rules 1986 of Ministry of Environmental (Protection) and Forest, read with GSR-371(E) Dated:17-05-2002 at S.No 95 for emissions limits and GSR-371(E) Dated:17-05-2002 at S.No 94 (Paragraph 1 and 3) for noise limits for the DG Set and as per the latest amendments if any. The following jobs are also included in the scope of work: The job includes providing of 50 ltrs of HSD for initial testing of DG set at site. The Test Certificate of DG set duly stamped by manufacturer shall be provided at the time of supply of material

1

617206

617206

... More
Providing, Installation, Testing & Commissioning of complete switchgear unit for protection of D.G Set consisting of 200A MCCB 3- pole , 415 V, 50 KV breaking capacity housed properly in cubical enclosure made up of M.S SWG – 16 sheet steel (outdoor type) duly powder painted with anti-corrosive paint comprising of three compartments for incoming / outgoing circuits and MCCB. The panel should have adequate double locking Arrangement with Cu-. Bus Bar 12x40 mm with Bakelite insulation and LT Arrangement selector switches, phase indicators. The equipment should be installed at appropriate height in a stand consisting of 50 x 50 x 6 mm angle grouted in ground with appropriate cement bottoming as per the IS standard.

1

39422

39422

... More
Electrification of Pump House by way of P/F of 1.5 mm sq. multi strand PVC wire for lighting points (08Nos.) and 2.5 sq.mm for heating points (04Nos.) to be laid in PVC Conduit Pipes in slab and brick walls of Pump House /as per site requirement. Lighting points should be run on Inverter also. Providing and fitting of Modular type board comprising of 6A Switch =08 No’s, 5-Pin 6A socket =04 No’s, Indicator= 02 No’s , Fan dimmer = 01No, 3-Pin 16A Switch Socket Combine =04No’s, 12 watt Slim Round Conceal Ceiling type = 08 No’s, Ceiling Fan=01 No , Main Switch board with input and output arrangement etc.

1

30000

30000

... More
Supply, installation, testing and commissioning Aesthetically designed higher wattage LED bulb for B22 lamp base, input voltage: AC-220-240Voltage, 50/60Hz, driver type integral, Lumen output 1060lm.

1

184

184.34

... More
Supply and fixing of PVC conduit of size 25mm for cable laying

1

3072

3072.8

... More
Supply, installation of saddle block 235mm for fixing of conduit pipes.

1

153

153.61

... More
Supply and fixing of 8 way gang box.

1

153

153.61

... More
Supply and fixing of 6AMp switch.

1

115

115.21

... More
Supply, laying and termination of 2.5Sqmm for lighting.

1

53

53.76

... More
1 inch and 1.5inch for fixing of electric fixtures.

1

92

92.17

... More
Supply and fitting of pandent holders for fixing of LED bulbs.

1

76

76.8

... More
Supply and fitting of dimmer for control of ceiling fan.

1

384

384.04

... More
Supply and fitting of 6 Amp 3-pin socket

1

384

384.04

... More
Supply and fitting of Square Block for fixing of Switch, Sockets.

1

307

307.23

... More
Main LT from transformer to panel viastablizer cable size = 3%1/2 core = 35mm

1

537

537.65

... More
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular plate, suitable GI box and earthing the point with 1.5Sqmm FRLS PVC insulated copper conductor single core cable etc. As required. (Group B)

1

1182

1182

... More
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. i. 2x1.5Sqmm + 1x1.5Sqmm earth wire.

1

233

233

... More
ii. 2x2.5Sqmm + 1x1.5Sqmm earth wire

1

275

275

... More
Supply and fixing of following sizes of medium Class PVC Conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required (32mm)

1

184

184

... More
Supply and fixing of following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. As required. i.5/6 A Switch

1

103

103

... More
ii. 3-Pin 5/6 A Socket Outlet

1

122

122

... More
iii. 15/16 A Switch

1

156

156

... More
iv. 6-Pin 15/16A Socket Outlet

1

197

197

... More
Supplying and fixing of two module stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc. As required.

1

369

369

... More
Providing and fixing extra conduit down rod of 20mm dia, 2x10cm length, wiring with 2x1.5Sqmm FRLS PVC insulated, copper conductor, single core cable including painting etc. S required (Note: More than 5cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored).

1

55

55

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5Sqmm FRLS OVC insulated, copper conductor, single core cable etc. As required.

1

213

213

... More
Numbering of ceiling fan / exhaust fan/ flurescent fittings s required.

1

57

57

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. As required. Upto 450mm Sweep.

1

450

450

... More
Providing and fixing of following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. As required. i.  32A TP&N

1

2152

2152

... More
ii.  63A TP&N

1

3144

3144

... More
Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240V on surface / recess, complete with tinned copper bus bar, neutral bar, earth bar, din bar, interconnections, powder painted including earthing etc. As required (But without MCB/MCCB/Isolator) i. 6 Way, Double door

1

2206

2206

... More
Providing and installing of 8W rounded Led Ceiling Light Complete Job

1

250

250

... More
Providing and installing of 200mm Exhaust Fan (Cut out size : 9.4 x 9.4 Square inchs / Watt: 32 / RPM: 1350 / Air Delivery: 520 / Suitable for sitchen, Bathroom and office.

1

1300

1300

... More
Providing and installing electric ceiling fan / 1200mm BEE star rates ceiling fan.

1

1500

1500

... More
O&M O&M for Ist Year ( After Completion of DLP)

1

90000

90000

... More
O&M for 2nd Year

1

100000

100000

... More
O&M for 3nd Year

1

120000

120000

... More
O&M for 4th Year

1

140000

140000

... More
O&M for 5th Year

1

150000

150000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.