Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date17 Aug 2024
Closing Date5 Sep 2024
Tender Amount₹ 4,81,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Improvement in protection of 2x3.15 MVA power transformers and Electrical HT works at W.S.S Tangnar Stage 2nd.
Improvement in protection of 2 X 3.15 MVA power transformers and Electrical HT works at W.S.S Tangnar Stage 2nd.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
P/F of complete 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm.

6

-

-

... More
Replacement of old damaged CT's by way of P/F of new 33 kV Current Transformers oil cooled (33 kV, 1Φ, 2 Ratio 3 Core, Outdoor Type) (1 No. per Φ) 50-100/5-5-5A with Accuracy Class: 0.5. All special tools and tackles like C.I tester etc. besides the skilled labour required for carrying out the job shall be arranged by the firm.

3

-

-

... More
P/F of new Resin Cast 11 KV Current Transformer (11 kV, 1Φ, Multi ratio - Multi core, Indoor Type) 150-300/5 (4 Core) with following details. Primary Current: 150-300 Secondary Current: 5 A Rated Burden: 10 VA Accuracy Class: 0.5 Frequency: 50 Hz All special tools and tackles like C.I tester etc. besides the skilled labour required for carrying out the job shall be arranged by the firm.

3

-

-

... More
P/F of 3 position, stay-put type PT selector switches to be fiited on 11 KV VCB Panel at an appropriate place. The job includes all sorts of labour, tools and tackles, cutting of pannel required for proper fitment.

4

-

-

... More
P/F of 16-window annunciator in 11Kv VCB Panel of below mentioned specifications: window Bright LED 16 Fault Size: 144 x 144 x 140 mm (2D) Test/Ack/Reset: Pushbutton Voltage range:90-270V AC or 12/24V DC Built in buzzer/ Contact for External Hooter. Make: GIC/EAPL/Minilec or equivalent. The job includes all sorts of labour, tools and tackles , cuttings required for proper fitment.

2

-

-

... More
P/F of 16-way three element auxiliary relay for 33/11KV transformer C&R Panel housed in a single cabinet with 4 NO + 1NC / 4NO + 2NC / 2NO + 3 NC per element as per site requireemnt with hand / self-reset contacts type and flag indications, used to initiate tripping commands to trip-coil of circuit breaker with following specifications:- Coil Supply =24 DC No. of Contacts= 4 NO + 1NC / 4NO + 2NC / 2NO + 3 NC per element as per site requirment. Contact Reset Type= Hand Reset / Self Reset Burden Approx= 25VA Operational Indicator = Flag Operating Range = 70% to 120% of rated Voltage. Contact Rating Continuous = Resistive-15A,110VAC, Inductive-3A, 25VDC Max. Mounting = Flush with screw Standard compliance IEC 60255:2009. Make: Crompton Greaves/Ashida or equivalent The job includes all sorts of labour, tools and tackles , cuttings required for proper fitment.

2

-

-

... More
Providing of 1.5 Sq. mm Single Core multi stranded Single Core HRFR PVC Insulated Industrial Grade Flexible Copper Conductor (Unsheathed), 1100 Volt Conforming to IS 694 inclusive of ferruling, thimbling etc . of Havels, Finolex or equivalent make.

90

-

-

... More
Providing and Fitting of 2.5 Sq. mm 4-Core Armoured Copper cable, XLPE Insulated, PVC Innersheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 inclusive of ferruling, thimbling etc . of Havels, Finolex or equivalent make.

60

-

-

... More
P/F of Digital Automatic Voltage Regulating Relay with following details: Auxiliary Supply: 110/230V AC ± 15%, 50Hz, 10VA PT Supply: 110V AC, 50Hz, 1.5VA Control Oper. : Single Pulse operation with approx. 2 secs. ON time. Lower Setting (LS) : Adjustable between 95 to 125 V Raise Setting (RS) : Adjustable between 90 to 120 V Time Delay Setting : Continuously adjustable between 10 to 120 Sec. Time Delay Resstting : Immediate with voltage returning to Control band UV Blocking : Blocking at 80V and restoration at 85V Control Relays : One pair of NO potential free contacts of 5A at 240V AC or 24V pulse DC for each Raise and Lower. Make : EMCO or equivalent All tools and tackles required for cutting of panel and carrying out the job shall be arranged by the firm.

1

-

-

... More
5W 400m Range Rechargeable LED Search Light of reputed make.

3

-

-

... More
Supply of 20 feet Long Bamboo ladder of good built quality at WSS Tangnar. The job includes carriage charges etc.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.