Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Jan 2023
Closing Date21 Feb 2023
Tender Amount₹ 1,71,56,600 
Notes
Download

Costs

Summary

Electrical And Mechanical Works Along With Laying And Fitting Of Departmental Rising Main To Be Carried Out At Wss Nowgam Gund Payeen Stage 1st And 2nd Under Jjm

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing, fitting, installation, testing and commissioning of VT pumping unit of following specifications: A. PUMP 1. Discharge = 7000 GPH 2. Type = Self water lubricated, VT pump, open line shaft. 3. Liquid to be handled = Clear Water 4. RPM = 1460 5. Head = 50 Meters 6. Efficiency = Not less than 75% B. Prime Mover 1. Type = Vertical hollow shaft, AC induction 2. Power Supply = 03 Phase, 41 5V± 10% AC 3. Frequency = 50Hz±3% 4. RPM = 1450 Synchronous 5. Efficiency = Not less than 85% 6. HP = Corresponding to Head and discharge but not less than 12.5HP. Rest of Specification/Details are as per clause 6 of Annexure "C" of SBD for stage 2nd for OHT 3rd proposed

2

-

-

... More
Providing/supplying and fitting of G.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) for Y junction Size : 150mm Class: C (Heavy) Rest of Specification as per clause 8 of Annexure "C" of SBD for stage 1st

30

-

-

... More
Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . Size: DN150 PN:1.6/16 Rest of Specification/Details are as per clause 12 of Annexure "C" of SBD for stage 1st

2

-

-

... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. Size: 150mm PN: 1.6/16 Rest of Specification/Details are as per clause 13 of Annexure "C" of SBD for stage 1st

2

-

-

... More
Providing/supplying and fitting of G.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) for Y junction Size : 100mm Class: C (Heavy) Rest of Specification as per clause 8 of Annexure "C" of SBD for stage 2nd

60

-

-

... More
Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . Size: DN100 PN:1.6/16 Rest of Specification/Details are as per clause 12 of Annexure "C" of SBD for stage 2nd

11

-

-

... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. Size: 100mm PN: 1.6/16 Rest of Specification/Details are as per clause 13 of Annexure "C" of SBD for stage 2nd

6

-

-

... More
Providing, fitting, testing and commissioning of Manually operated copper wound, 3-phase, AC power supply multi step voltage stabilizer. Rating::50KVA Stage-2nd Manufacturers test certificate to be apended and rest of specification as per clause 44 of Annexure "C" of SBD for stage 2nd

5

-

-

... More
Providing, fitting, testing and commissioning of Manually operated copper wound, 3-phase, AC power supply multi step voltage stabilizer. Rating::100KVA Stage-1st Manufacturers test certificate to be apended and rest of specification as per clause 45 of Annexure "C" of SBD.

2

-

-

... More
Stage 1st: Creation of pole mounted , outdoor type Electric Sub Station by way of S/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling: ONAN. Rating: 200 KVA HT Transformer, 3 phase (Level 2). Manufacturers certificate be apended and rest of specification as per cluase 26 of Annexure "C" of SBD for stage 1st

1

-

-

... More
Stage 2nd: Creation of pole mounted , outdoor type Electric Sub Station by way of S/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling: ONAN. Rating: 200 KVA HT Transformer, 3 phase (Level 2). Manufacturers certificate be apended and rest of specification as per cluase 26 of Annexure "C" of SBD for stage 2nd

1

-

-

... More
Supply, installation, erection of 9 mtrs long H.T pope of specifications ST410 (SP-33). The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. as per Clause 32 of Annexure "C" of SBD for stage 1st & 2nd

20

-

-

... More
Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole

24

-

-

... More
Providing and fitting G.I Channel /Angle/ Flat /Riser of sizes including clamps as per Clause 27 of Annexure "C" of SBD for stage 1st & 2nd

650

-

-

... More
Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. as per Clause 28 of Annexure "C" of SBD for stage 1st & 2nd

2

-

-

... More
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation. as per Clause 29 of Annexure "C" of SBD for stage 1st & 2nd

2

-

-

... More
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type as per Clause 30 of Annexure "C" of SBD for stage 1st & 2nd

2

-

-

... More
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm as per Clause 31 of Annexure "C" of SBD for stage 1st & 2nd

25

-

-

... More
Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) as per Clause 61 of Annexure "C" of SBD for stage 1st and 2nd

2

-

-

... More
Painting of poles Red oxide as per Clause 37 of Annexure "C" of SBD for stage 1st & 2nd

8

-

-

... More
Painting of poles Aluminum paint as per Clause 38 of Annexure "C" of SBD for stage 1st & 2nd

8

-

-

... More
P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043 as per Clause 48 of Annexure "C" of SBD for stage 1st and 2nd

10

-

-

... More
P/L of ACSR conductor of size 0.05 as per the relevant IS standard as per clause 78 of Annexure "C" of SBD for stage 1st

2000

-

-

... More
Providing and fitting of 3”x5/8” Galvanized nuts and bolts

70

-

-

... More
Providing and fitting of LT Distribution box for H.T transformer with MCCB For incomer and SFU for outgoing circuits as per clause 42 of Annexure "C" of SBD

2

-

-

... More
Distribution Cables: Providing, Installation, testing of multi-stranded copper conductor PVC insulated single core unsheathed 70mm sq. Copper cable for internal distribution wiring for stage 1st

150

-

-

... More
Distribution Cables: Providing, Installation, testing of multi-stranded copper conductor PVC insulated single core unsheathed 35mm sq. Copper cable for internal distribution wiring for stage 2nd as per clause 67 of Annexure "C" of SBD

400

-

-

... More
Fabrication Providing and fitting of modular control panel for stage 2nd . THE technical details/ Ratings of various components of Modular Control Panel are given Below a. Main Circuit Breaker (Incommer MCCB) of rting = 160-200Amp With S.C. Breaking Capacity of 50kA b. Changeover Switch of rating = 100Amp c. Motor Breakup Protection MCCB of rating = 100-125 Amp With S.C. Breaking Capacity of 36kA d. FASD Submersible starter suitable for 30 HP Load with Relay range of 30-50 Amp e. Auxillary MCCB for Heating/Lighting = 63 Amp With S.C. Breaking Capacity of 25kA f. Capcitor bank of 15KVAr cpacity Rest of Deatils/Technical specification are as per clause 43 (e) of Annexure "C" of SBD for stage 2nd

3

-

-

... More
Fabrication Providing and fitting of modular control panel for Stahe-1st . THE technical details/ Ratings of various components of Modular Control Panel are given Below a. Main Circuit Breaker (Incommer MCCB) of rting = 250Amp With S.C. Breaking Capacity of 50kA b. Changeover Switch of rating = 200Amp c. Motor Breakup Protection MCCB of rating = 160-200 Amp With S.C. Breaking Capacity of 36kA d. FASD Submersible starter suitable for 75 HP Load with Relay range of 66-110 Amp e. Auxillary MCCB for Heating/Lighting = 63 Amp With S.C. Breaking Capacity of 25kA f. Capcitor bank of 15KVAr cpacity Rest of Deatils/Technical specification are as per clause 43 (h) of Annexure "C" of SBD

1

-

-

... More
Providing and Fitting of 120 sqmm single core LT 1.1 KV for stage stage ist and 2nd, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer/DG set to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of appropriate size and connected by hydraulic crimp tool only for stage 1st and 2nd

300

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes, ISMC,ISMB,ISA etc.) trusses, construction of liner etc. including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer , including welding and bolted with special shaped washers etc. complete Stage 1st & 2nd The drawings and Dimensions for Gantry/Transformer Bed/Pumping Equipment Base will be provided by Site In Charge at the time of execution of job

3150

-

-

... More
Providing, installation and testing of manual type triple spur gear chain pulley block at stage 1st and 2nd along with monorail geared travelling trolley having following features Make = Reputed make Capacity = 3 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Rest of Deatils/Technical specification are as per clause 24 of Annexure "C" of SBD for stage 1st and 2nd

3

-

-

... More
Illumination of Premises: Stage 1st and 2nd Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest of Deatils/Technical specification are as per clause 50 of Annexure "C" of SBD for stage 1st and 2nd

2

-

-

... More
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole Having following specs: Input: 90-240 V 50 Hz Power Factor: 0.9 Rest of Deatils/Technical specification are as per clause 51 of Annexure "C" of SBD for stage 1st and 2nd

8

-

-

... More
Providing and installation of Junction Box with DP 32Amp MCB to serve as amin switch for LED lighting for stage 1st and 2nd Rest of Deatils/Technical specification are as per clause 52 of Annexure "C" of SBD

2

-

-

... More
Providing, Installation and testing of 2KVA fully automatic voltage stabilizer for stage 1st and 2nd Rest of Deatils/Technical specification are as per clause 53 of Annexure "C" of SBD for stage 1st and 2nd

2

-

-

... More
Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter with 12V, 180AH Tubular inverter Battery for stage 1st and 2nd Rest of Deatils/Technical specification are as per clause 54 of Annexure "C" of SBD

2

-

-

... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen . Rest of Deatils/Technical specification are as per clause 55 of Annexure "C" of SBD for stage 1st and 2nd

30

-

-

... More
TOOL KIT For Maintenance: -stage 1st and 2nd The Tool Kit for maintenance as per detailed specification in cluase 56 of Annexure "C" of SBD for stage 1st and 2nd

2

-

-

... More
Providing of good quality conveinence and utility items as per details in Caluse 57 of Annexure "C" of SBD for stage 1st and 2nd

2

-

-

... More
Fabrication of 6’ x 6’ angle iron bed for operators. Rest of Deatils/Technical specification are as per clause 58 of Annexure "C" of SBD for stage 1st and 2nd

189.5

-

-

... More
Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos. Rest of Deatils/Technical specification are as per clause 59 of Annexure "C" of SBD for stage 1st and 2nd

36

-

-

... More
Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply for stage 1st and 2nd

2

-

-

... More
Providing of 1 KW heat convector for operators for winter season for stage 1st and 2nd

2

-

-

... More
Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal Rest of Deatils/Technical specification are as per clause 64 of Annexure "C" of SBD for stage 1st and 2nd

18

-

-

... More
Providing & fitting of lighting points for ( machine room , operators room,) as per site requirement in 1.5 mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit pipe by way, switches, socket modules , regulators ,indicators, 08/10 watt LED lamps Surface light Make. .Included is cost on account of modular switch boards with the wooden frames as per site requirements for stage 1st and 2nd

16

-

-

... More
Providing fitting of heating points in 2.5mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit by way of p / f of 15 Amp switches, 6 pin socket on modular fitting as per site requirements. Heating points are to be connected from main control panel. All accessories required is to be provided by the firm for stage 1st and 2nd

4

-

-

... More
Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. Rest of Deatils/Technical specification are as per clause 65 of Annexure "C" of SBD for stage 1st and 2nd

48

-

-

... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 Size = 25 Sq mm for stage 1st and 2nd as per details in Clause 47 of Annexure "C" of SBD

50

-

-

... More
Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 100mm Rest of Specification/Details are as per clause 16 of Annexure "C" of SBD for stage 1st and 2nd

2

-

-

... More
Handling, laying and joining by welding of departmental GI/MS prefabricated, Medium class GI/MS Rising Mains from Stage 1st to PST and from clear water sump to 03 Nos. OHTs As per detailed specification in cluase 115 of Annexure "C" of SBD

-

-

-

... More
For 200 mm Dia MS Pipe

5310

-

-

... More
For 100 mm Dia GI Pipe

1522

-

-

... More
Providing, fitting and testing of approved quality 200mm dia. sluice valve (01 No), along with 200mm dia. dismantling joint (01 Nos) in the MS Rising Mains at the required location as per the directions of site Engineer. The dismantling joint is to be installed with the sluice valve with the help of flanges including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.

2

-

-

... More
Providing, fitting and testing of approved quality 100mm dia. sluice valve (01 No), along with 100mm dia. dismantling joint (01 Nos) in the GI Rising Mains at the required location as per the directions of site Engineer. The dismantling joint is to be installed with the sluice valve with the help of flanges including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.

5

-

-

... More
Providing, fitting and testing of approved quality 200mm dia. NRVs (01 Nos), along with 200mm dia. dismantling joints (01 Nos) in the MS Rising Mains at the required locations as per the directions of site Engineer. The dismantling joints are to be fitted with the Non Return valves with the help of flanges including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.

2

-

-

... More
Providing, fitting and testing of approved quality 100mm dia. NRVs (01 Nos), along with 100mm dia. dismantling joints (01 Nos) in the GI Rising Mains at the required locations as per the directions of site Engineer. The dismantling joints are to be fitted with the Non Return valves with the help of flanges including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.

6

-

-

... More
Providing, fitting and testing of approved quality 50mm dia. CI Double Acting Air Release Valves (01 Nos) in the GI/MS Rising Mains at the required locations as per the directions of site Engineer including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.

6

-

-

... More
Providing, fitting and testing of approved quality 200mm dia. Enclosed Type Water Meter ( Bulk Type) (01 Nos) in the MS Rising Mains at the required locations as per the directions of site Engineer including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.

1

-

-

... More
Providing, fitting and testing of approved quality 100mm dia. Enclosed Type Water Meter (Bulk Type) (01 Nos) in the GI Rising Mains at the required locations as per the directions of site Engineer including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.