Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Excavation
Water Storage And Supply
Eprocure
Opening Date13 Dec 2024
Closing Soon27 Dec 2024
Tender Amount₹ 1,41,79,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Integrated Development of Ranjit Sagar Reservoir in District Kathua under Pradhan Mantri Matsya Sampada Yojna (PMMSY) under Deposit Contribution works
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete

4.99

416

2078.34

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : 1:6 ( 1 cement : 6 coarse sand)

22.11

7571

167406.97

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

22.11

1455

32184.42

... More
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

6.12

10377

63508.16

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

150

181

27240

... More
Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonals braces of 40x40x6mm angle iron, 3mm M.S. gusset plates at the junction and corners, 25mm dia pulley, 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer,

9.36

6441

60294.31

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to steel windows by welding

100

212

21200

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.40mm thick with 20 mm nominal size stone aggregate

29.01

510

14802.35

... More
Providing & fixing of glass strips in joints of cement concrete floor 40 mm wide and 6mm thick

40.55

78

3183.17

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

14.7

180

2654.09

... More
White washing with lime to give an even shade on New Work (three or more coats)

104.34

29

3124.98

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)

118.31

98

11683.11

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade

37.44

131

4936.46

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete

23.85

572

13661.28

... More
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.110 mm diametre

8.2

366

3003.66

... More
15mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix1 : 4 ( 1 cement : 4 fine sand)

222.65

397

88436.58

... More
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)

40.95

241

9879.19

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.

3.76

577

2171.59

... More
Centering and shuttering including strutting, propping etc. and removal of form for: slab Suspended floors, roofs, landings, balconies and access platforms

40.95

718

29410.29

... More
Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete

105.21

286

30126.88

... More
Edges of slabs and breaks in floors and walls Under 20 cm wide

28.6

262

7498.92

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo -Mechanically Treated bars of grade Fe-500 or more

600

123

73920

... More
Carriage of Sand and stone aggregate up to 20mm by Mechanical Transport from source (to be identified by engineer in charge) to site of work/dumping place including cost for loading,unloading & stacking for an av. lead up to10 Km

64.63

279

18034.36

... More
Carriage of Cement by Mechanical Transport from source (to be identified by engineer in charge) to site of work /dumping place including cost for loading,unloading & stacking for an av. lead up to 10 Km

13.65

240

3276.41

... More
Carriage of Steel by Mechanical Transport from source (to be identified by engineer in charge) to site of work /dumping place including cost for loading,unloading & stacking for an av. lead up to 10 Km

0.6

240

144.02

... More
Carriage of d stone aggregate up to 40mm by Mechanical Transport from source (to be identified by engineer in charge) to site of work/dumping place including cost for loading,unloading & stacking for an av. lead up to10 Km

7.78

303

2359.99

... More
Carriage of Bricks from brick kiln (to be identified by engineer in charge) by Mechanical Transport to site of work /dumping place including cost for loading,unloading & stacking for an av. lead up to 10 Km

10.5

744

7815.06

... More
Provsion for electric fitting including underground conduit pipes, wiring, steel boxes and switches for 04 no. light point (internal) with holders and LED Bulbs and external 04 no. with Halogen/LED light (External grade) including service line (Complete Job).

1

15000

15000

... More
OHT Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :

142.49

592

84482.32

... More
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :

256.85

213

54896.55

... More
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil :

91.66

89

8226.49

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level with 1:4:8 (1 cement : 4 Sand : graded stone agg. upto 40mm niminal size)

13.27

5202

69042.48

... More
Dry stone pitching (any thickness) excluding cost of stones on horizontal

26.53

535

14208.14

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

13.27

5733

76084.87

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve (REINFORCED CEMENT CONCRETE) 99 CODE NO.DESCRIPTION UNIT RATE ₹ workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level

113.82

8021

912961.6

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve 5.0 (REINFORCED CEMENT CONCRETE) 99 CODE NO.DESCRIPTION UNIT RATE ₹ workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V level

90.52

9412

851978.77

... More
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

5.77

10377

59876.16

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve 5.0 (REINFORCED CEMENT CONCRETE) 99 CODE NO.DESCRIPTION UNIT RATE ₹ workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V level

15.27

9412

143722

... More
Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete

38.32

286

10972.93

... More
Extra for shuttering in circular works

38.32

57

2194.59

... More
Centering and shuttering including strutting, propping etc. and removal of form for: slab Columns, pillars, piers, abutments, posts and struts.

217.8

742

161727.39

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.

127

577

73348.85

... More
Centering and shuttering including strutting, propping etc. and removal of form for: slab Suspended floors, roofs, landings, balconies and access platforms

130.66

718

93840.01

... More
Extra for shuttering in circular works

27.32

143

3924.24

... More
Centering and shuttering including strutting, propping etc. and removal of form for:Arches, domes, vaults upto 6 m span

72.55

2281

165501.06

... More
Extra for arches domes vaults exceeding 6mtr span

72.55

1118

81172.57

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

288.31

628

181332.57

... More
Extra for shuttering in circular works

288.31

125

36266.51

... More
Centering and shuttering including strutting, propping etc. and removal of form for edges of slabs and breaks in floors and walls under 20 cm wide

174.25

262

45688.35

... More
Extra for Reinforced cement concrete work in super structure above floor 5 level for each four floor or part thereof

49.86

280

14008.17

... More
Extra for additional height in centering and shuttering for every additional height of 1 meter or part thereof above 3 meter (plan area to be measured)

-

-

-

... More
Lift 1/Beam 2

4.76

293

1397.49

... More
Lift 4/Beam 3

4.76

1175

5589.98

... More
Lift 7/Beam 4

4.76

2057

9782.46

... More
Lift 10/Beam 5

4.76

2939

13974.95

... More
Lift12/Beam 6

4.76

3526

16769.93

... More
Lift 1

2.43

293

714.18

... More
Lift 2 &3

2.43

881

2142.53

... More
Lift 5&6

2.43

1469

3570.89

... More
Lift 8&9

2.43

2351

5713.42

... More
Lift 11 &12

2.43

3526

8570.12

... More
Lift 13 &14

2.43

4114

9998.48

... More
Lift 1

1.44

293

423.22

... More
Lift 4

1.44

1175

1692.86

... More
Lift 7

1.44

2057

2962.51

... More
Lift 10

1.44

2939

4232.16

... More
Lift 14

1.44

4114

5925.02

... More
Lift 15

1.44

4408

6348.24

... More
Top landing/Lift 16

27.32

4702

128460.16

... More
Brick work with non modular fly ash bricks confirming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level upto floor five level including curing complete in:1:6(1cement : 6 coarse sand)

6.9

6885

47512.71

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

6.9

1455

10043.99

... More
12mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 3 ( 1 cement : 3 fine sand)

184.64

370

68455.28

... More
15mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1 : 4 ( 1 cement : 4 fine sand)

113.55

397

45102.06

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo -Mechanically Treated bars of grade Fe-500 or more

29300

123

3609760

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

1812.39

181

329130.02

... More
Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonals braces of 40x40x6mm angle iron, 3mm M.S. gusset plates at the junction and corners, 25mm dia pulley, 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer,

3.68

6441

23705.46

... More
Providing and fixing G.I. pipes complete 32 mm dia. nominal bore including welding for railing works

150

384

57600

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.(1 kg of water proofing material in 50 kg of cement)

67

354

23755.52

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600 mm

21.37

1617

34575.59

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade

67.69

131

8924.93

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)

813.05

98

80288.69

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

217.73

180

39311.15

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329 100 mm dia Ductile Iron Double Flanged

100

1530

153060

... More
Providing and laying D.I. Specials of Class K-12 suitable for mechanical jointing as per IS : 9523 Upto 600 mm dia.

7

17971

125801.55

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately).100 mm dia class -II

5

4453

22269.25

... More
Providing & fixing S C I S&S 100 mm dia bend

8

300

2400

... More
Providing and fixing 100 mm Slotted Cowls (Terminal Guard)S C.I. S & S

8

300

2400

... More
Providing and fixing of lightning conductor complete job along with fixing of Aluminum strips and earthling which includes digging of a pit in the earth which should not be less than 3m (10ft) from the ground level . A plate made up of Aluminium with dimensions 60cm x 60cm x 3.18mm is buried vertical in the earth (earth pit) which should not be less than 3m (10ft) from the ground level and connecting al. strip of 32mm x 5mm along with nuts and bolts inside the pit with the earthing plate and extending the strip up to the machinery. Put about 30 cm layer of powdered charcoal and salt around the earth plate in alternate layers up to 06 feet . Providing and fitting of 25 mm dia GI pipe for putting water inside the pit to maintain moisture. The job also includes the construction of chamber made of brick masonary with CI cover 45 cm x 45 cm. The job includes the cost of material, labour, transport charges , testing and any other miscellaneous charges.(Note: The distance between the two earth should not be less than 06 mtrs). Complete job as per scope of work in SBD. Earthing and other allied works

1

60000

60000

... More
Supply , installation and commissioning of level transmitter in sump and overhead tanks, Ultrasonic type having range ( 0-8m) with 24-48VDC connections including cabling, conduiting as per technical specifications complete

1

80000

80000

... More
Providing and fitting concealed internal Electrification of room including 4 Nos LED lights, Fan points 2 No., Fuse box 1 No., 2 no 15 Amp sockets with switch, 5 Amp 2 no. sockets with switch - of approved brand and 04 nos LED security lights 30 watts, Main switch with complete wiring, with MS bracket for pole mounting complete including service line up to a length of 10 meters.

1

20000

20000

... More
Carriage of Sand and stone aggregate up to 20mm by Mechanical Transport from source (to be identified by engineer in charge) to site of work/dumping place including cost for loading,unloading & stacking for an av. lead up to10 Km

243.01

279

67809.51

... More
Carriage of Cement by Mechanical Transport from source (to be identified by engineer in charge) to site of work /dumping place including cost for loading,unloading & stacking for an av. lead up to 10 Km

66.06

240

15856.38

... More
Carriage of Steel by Mechanical Transport from source (to be identified by engineer in charge) to site of work /dumping place including cost for loading,unloading & stacking for an av. lead up to 10 Km

17.05

240

4092.51

... More
Carriage of Bricks from brick kiln (to be identified by engineer in charge) by Mechanical Transport to site of work /dumping place including cost for loading,unloading & stacking for an av. lead up to 10 Km

2.89

744

2150.59

... More
Carriage of Soling Stones (to be identified by engineer in charge) by Mechanical Transport to site of work /dumping place including cost for loading,unloading & stacking for an av. lead up to 10 Km

19.54

328

6415.18

... More
Pipe Network:- Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil

511.2

479

245018.16

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 150 mm dia (M)

300

2256

677070

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 100 mm dia (L)

250

1255

313787.5

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 80 mm dia (M)

320

878

281040

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

460.08

180

83067.44

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). ( 100 mm dia) Class-II

20

4453

89077

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). ( 150 mm dia) Class-II

2

6642

13285.1

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). ( 80 mm dia) Class-II

10

4000

40000

... More
Providing and fixing Check valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). ( 150 mm dia)

2

10000

20000

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 50 to 80 mm nominal bore

30

1387

41617.5

... More
Welding, including transportation of plant at site etc. complete By electric plant

8000

6

49600

... More
Electromechanical Components a) Providing,Installation,Testing&CommissioningofSubmersiblePumpingUnitasperIS8034ofreputedmakewithfollowing specification under National Fish Farm Kathua Specification:-Pump:- 1. Type:-MixedFlow . 2. Discharge:-Asmentionedinparametersoraspersiterequirement 3. Totatdynamichead:-Asmentionedinparametersoraspersiterequirement 4. Typeoffluidtobehandled-ClearWater 5. Impeller:- IS-8034code 6. Pumpcasing:-CastIron 7. Efficency:-Notlessthan45% 8. speed:-2800-3000rpm COUPLING:Asuitablecouplingarrangementprovidedwithpumpset. NonReturnValve:-NonReturnValveofthesuitablesizeprovidedabovethepumpdischargecase.MOTOR:- Speed: compatiblewithpumpspeedWorking Volatge : 03 phase, 415 ±10% V Rating - Suitable for above parametersClassofinsulation-F/Suitableforaboveparameters Submersiblemotorshouldbewaterfilledwaterlubricatedsquirrelcagetypehavingcapacityforabovepumpingparameters.Themotor should be sealed byradialringstoavoid mixingofwellwater with motor filled water. b) Thejobincludesprovidingandfittingofinterlockingarrangementagainstanyfailureofcoupling.Itmustbefabricatedoutof MS strips of suitable size and length c) ThejobincludesprovidingandfittingofappropriatesizeMSnipple2feetlongthreadedononeendandweldedtosamesizeMSflangeofthickness12mmatotherendfor50mm/65mm/80mmdiametercolumnpipeaspersiterequirement.Thethreaded portion should be as per size of pumping out let for proper fixing. d) Fabrication,providingandfittingofsplittypeMSclamps10mmthick,2ftlongand3inchwideforloweringandholdingofpumpingunitfitted.Thejobincludesthecostofrequiredsizeofnutsandbolts.fittingof3-Coreflatsubmersiblecoppercable for SubmersiblePumpingUnitandother electricalEquipment.Thecableconnectionsterminalshallbefittedwithcopper thimbles of required size. e) The jobincludesprovidingand fittingofR. I. cloth joints/rubber washerswith nuts,bolts and washersforalljointsofcolumnpipe.ThejobalsoincludesloweringofpumpingunitinthewellaspersiterequirementsandFabrication,providingand fittingofwashout Tee with armlength 1.2 feeteach. TheTeeshallbefabricated outofG.Ipipewith M.SFlangesfastenedwithweldjointsonthreeends(Aspersiterequirement)andfittedwithsluivevalveaspersiterequirement.Thenproper testing and commissioning of pumping unit on full load at site. Note:ProvidingofthirdpartyinspectioncertificateofRITES/CEIL&CharacteristicCurveofpumpingequipmentis compulsoryandisto beapprovedfromtheconcernedEngineerininchargebeforeinstalling. TheParametersofvariousSubmersiblepumpsettobeinstalledarementionedbelow:

-

-

-

... More
SPS3000GPHx(100-120)MtrHead

2

190000

380000

... More
Fabrication, providing, fitting and lowering of B Class column pipe conforming to IS: 1239 of length 10 Rft into the production well up to the desired depth; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange.

-

-

-

... More
(80MM DIA)

25

6990

174750

... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for the operation of above mentioned submersible Pumping Unit and length as per site requirement. The cable connections terminal shall be fitted with copper thimbles of required size.

-

-

-

... More
(6 Sqmm)

180

670

120600

... More
Design , supply , installation , testing and commissioning of automatic power factor correction panel for improvement of power factor as per details given below: input voltage = 380 ± 15 V Ambient temp. = 0 ̊c to 50 ̊c Available Power Factor = 0.7 - 0.8 Target power factor = 0.98 lagging Switching time delay On delay = 1 – 60 seconds 0ff delay = 1- 60 seconds Control type = Binary/ intelligent CT Ratio programming = To be provided Programming link = To be provided Auto Scroll = To be provided Manual operation = To be provided Display Parameters = PF (input/output), KW, Volt, Amps. Relay contacts = As per requirement Dimensions = Adequate Bezel / panel Cut out = Adequate System protection = IP 55 Enclosure = Modular CRG Sheet , powder coated MCCB Main protection = As per requirement MCCB (Individual Protection of capacitors) = As per requirement 3 No. Power factor correction panel for improvement of power factor Suitable for connected load upto:-

-

-

-

... More
(up to 30 HP)

1

75900

75900

... More
Earthing of the electromechanical equipments: 01 no earth for electrical equipments and 01 no earth for body earth of pumping machinery which includes digging of a pit in the earth which should not be less than 3m (10ft) from the ground level . A plate made up of GI with dimensions 60cm x 60cm x 3.18mm is buried vertical in the earth (earth pit) which should not be less than 3m (10ft) from the ground level. Put about 30 cm layer of powdered charcoal and lime mixture around the earth plate in alternate layers. Providing and fitting of 40 mm dia pipe of 2.5 m length and GI strip of 32mm X 05 mm along with nuts and bolts inside the pit. Providing and fitting of 25 mm dia slotted pipe for putting water inside the pit to maintain moisture. The job also includes the chamber made of brick masosanary with CI cover 45 cm x 45 cm. The job includes the cost of material, labour, transport charges and any other miscellaneous charges.(Note: The distance between the two earth should not be less than 06 mtrs).

1

40000

40000

... More
Providing and Fitting of 3.5-Core, XLPE, Armored Aluminium Cable of suitable size and length conforming to IS: 7098 part 1st as service line from the HT transformer to voltage stabilizer including necessary thimbling, crimping, taping etc.

-

-

-

... More
(70 sq.mm)

30

1320

39600

... More
Fabrication of the 01 nos board made out of angle iron and having a size of 06ft X 04 ft. The angle iron is to be welded at corners properly and flushed in all directions including its grinding or foiling to avoid body scratches. The panel board is to be surmounted with a ply of 06ft X 04 ft X 12mm thickness. The board shall have two legs at the corners and two legs are to be welded/grouted with the wall of the pump room. The job also includes the p/f of 01 no 415 volt, HRC fuse type main switch and 01 no Bus Bar, 03 no RYB phase indicator, voltmeter and ampere meter along with CT on board of reputed make conforming to IS standard of required specification for below mentioned connected load. The job also includes the P/F of cables of required size and length as per site for the connection of power supply of reputed make and conforming to IS standards with proper thimbling. The job includes the cost of material, fixation, transport and labour charges. -

-

-

-

... More
(up to 30 HP)

1

66000

66000

... More
Providing, Installation and testing commissioning of motorized chain hoist as per site requirement with hook suspension having following features and characteristics:- Make - Reputed make Capacity - As mentioned below in or as per requirement Hoisting speed - 2.4 M/Min Hoist motor H.P - as per requirement Min. Height of lift - 6 M Motor: The basic drive of the hoist be provided with 3 phase squired cage totally enclosed induction motor having a high starting torque with class “F” insulation. The make of the motor be NGEF / SEIMNS / GEC/ Crompton and conform to IS : 325 (RPM-1500) Brake: The hoist shall have instant action, Fail to safe electromagnetic disc brake mounted on the end of the motor to ensure minimum safety and reliability when the load is held in its position as soon as the supply to the motor is switched off internally or accidentally. The adjustment & maintenance of break shall be quick and simple. Gears: The hoist shall have precision cut super and helical gears made of alloy steel mounted on bearings and housed in a dust proof gear box. The lubrication of gears is of high viscosity and temperature for longer life of gears. Load Chain: The load chain is made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel: Specially designed, perfectly machined wheel providing correct grip of load chain made of malleable cast iron makes the hoist most safe and reliable against any failure. Lifting Hook: The lifting hook shall be forged with provision for free swivelling. Limit Switch: The limit switch shall have snap action, shunt type prevent over hoisting or over lowering to ensure maximum safety of operation. Control: The unit shall be controlled by heavy duty air break direction reversing type contractors and electrically inter – locked for safety. Contactors relay, fuses, low voltage transformer be fitted for control voltage and are to be housed in fabricated / pressed sheet steel box dust proof. Push button pendent: The contactors shall be operated by a pendent push button station suspended from hoist by a rope / dog chain to prevent any damage to the pendent cable and for easy operation. Test: The hoist supplied is to be tested at 25% overload and the test certificate of the same be provided at the time of installation. The complete unit as specified above is required to be fitted / tested at site. Besides the above works the job Includes Providing and fitting 3-Core 6 sq. mm ,50 m submersible cable for providing power supply to motor of chain Hoist including P/F protection device of suitable capacity. The capacity of motorized chain hoist to be installed are mentioned below: :-

-

-

-

... More
(3.00 M.T Capacity)

1

330000

330000

... More
Electrification of the pump room by way of providing and fitting main control unit, 03 No. Lighting points inside the pump room along with 9 watt LED bulbs and 03 Nos. outside the pump room with Providing and fitting of 50 Watt LED lights and 1 no fan. The job also includes Providing and fitting of 02 Nos. 06 amp sockets and 02 Nos. 16 amp sockets and switches inside the pump room. Providing and fitting of main control unit with MCBs. along with allied works (all material should be of reputed make conforming to IS standard) The job includes lying of cable and batten of appropriate size required to cover all the points. The job includes proper thimbling and providing insulation using insulation tape on each end. The job includes the cost of material, fixation, labour and transport charges

1

25000

25000

... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 3M long. The rubber mats shall be accepted with manufacturers test certificate.

1

9000

9000

... More
Fabrication of gantry mechanism by way of fabrication and erection of M.S./ G.I. Pipe Gantry for extrection and lowering of submersible pump set along with column pipe. The job includes fabrication of 02 nos vertical members of M.S/ G.I Pipe 6" dia medium class each of height 15 ft. embedded in cement concrete block of 3'x3'x3' from bottom of the vertical column pipe 02 nos. It includes earth work for excavation of foundation of size 3'x3'x3' of cement concrete block for embedding of foot of vertical column. cast of cement concrete block in 1:2:4 mix of size 3'x3'x4'(1'AGL). Providing and embedding of 04 nos foundation blots of size 2'x16mm in eachblock. the job also includes providing and fitting of 02 nos MS plates 8 mm thick of size 2'x2' welding of 04 nos ribs at base of the column pipes and 02 nos MS plates 8 mm thick of size 1'x1' at the top of column pipes, welding of 04 nos ribs at the base of the vertical column pipes for strengthening of vertical column pipe, placing/welding of horizontal 4"dia-8ft pipe above the column vertical pipes. the job also includes providing and welding of main cross member made out of 4" dia M.S/G.I pipe-1.5 mtrs medium class on top. Making og one number MS steel ladder on side of vertical pipe fabricated out of MS angles (1.5' Length) of suitable size and shall be welded properly at an equidistant of 1 ft each from bottom to top of MS Column pipe. The job includes painting of pupes by way of making surface smooth emert paper and initially giving one coat of red oxide and finally two coats of black enamel paint for smooth finish.

1

125000

125000

... More
Providing, fitting, testing and commissioning of voltage stabilizer as per below specifications: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Change over Switch: : Qty. : 1No. Make : reputed make Rating : Suitable capicity Type :Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz. Input voltage :2 50-460 volts.(3 phase) Output voltage : 4 00 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fibre glass insulations to tested parameters. Cooling :Naturally, Oil cooled Temp. Rise (Max): 3 0°C above ambient Mounting : O n Uni-directional wheels. Correction rate : 3 0 volts per step Wave form distortion : v irtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. The job also include P/F of Copper cable of reputed make conforming to IS code and suitable capacity of required length as per site requirement for connection of power supply to voltage stabilizer

-

-

-

... More
( 50 KVA)

1

214500

214500

... More
Design, fabrication, installation, testing and commissioning of LT control panel for the operation of Submersible motor of below mentioned pumping machinery. The LT panel shall be dust and vermin prooffabricated out of SWG CR sheet supported on MS angle of Suitable size and provision for fixing it on the ground with thehelp of foundation Bolts/ wall Mounted as per site requirement. The panels should be sturdy enough for vibration freeoperationandshouldbeequippedwithsuitablelocking/sealingarrangementforeachbox.Thestructureshouldbeprovidedwith the suitable entry and exit holes for incoming and outgoing cables. The Panel should be given two coats of anti-rustprimer and two coats of enamel paint for smooth and even finish. Incoming Feeder:The incoming feeder for the operation induction/submersible motor must be equipped with a suitablecapacityMCCBofSuitablebreakingcapacity.Theremust beAl./copperbusbarsforallthethreephasesfromtheoutgoingofthe MCCBtoallthethreecontactor.Thepanelmustbe fitted with 01 No. Volt0-500 and01 noampere meter of suitablerangewith proper CT ratioshowingvoltage and currentofallthe three phasesand RYB phase indicator lamps. Outgoing Feeders:The outgoing feeders for the operation of induction motor/submersible motor must be fitted withfollowingitems: 1 Aiir break contactors. of suitable rating for each motor of reputed make conforming to IS code. as per siterequirement. 1. Star-Deltatimerforeach motor 2. Motor Protection relays having all the features such as Overload, short circuit, under current, phase unbalance, Phasesequence, Phase Loss, Earth fault, Dry running, Prolonged Starting/ Stalled rotor. The relay is be fitted on the door and itmust be accessible bykeeping the door of the panel closed.for each 3. SinglePhasepreventer.foreach 4.02No.indicatorlampsforONand TRIPindication.foreach 5.02 No.Push ButtonsforON/OFF.foreach 6.10ampMCBsforprotectionof thecontrolwiring. 7. Autostartwithondelaytimer.foreach 8. LevelcontrolersensorforautoON/OFFof motorsaspersiterequirement. 9. VoltmeterandAmperemeterforeachwithproperCTratio 10. FaultDisplayIndicatorwithProperLayout, 11AutoPhaseCorrection ThecablingoftheControlpanelmustbedonewiththesuitableratingmultistrandcoppercabletowithstandthefullloadofrunningmotors.TheinternalcontrolwiringshouldbedonewithflexiblePVCLTcablewithproperthimblingateachend. The job also includes the P/Fofcables of required size and lenght as per site for the connection of power supplyto LTpanelofreputedmakeandconformingtoISstandards.ThecapacityofvariousLTpaneltobeinstalledarementionedbelowor as per site requirements. (Note:Panelshouldbeofoutdoortypeconformingtoall standard as per IS code, if Panelhave toinstall out side the pump roomand Levelcontroler willbe installwhere Sump/OHT are with in satation or as per site requirement.)( up to 30HP)

2

153000

306000

... More
Drilling of Bore well:- Setting up of drilling site by way of shifting of requisite machinery and allied material after making proper approaches as per requirement at site.

1

20000

20000

... More
Boring/drilling 200mm dia. Bore Well, 120 meter below ground level or till sufficient aquifer Zone/discharge is encountered, by using ODEX Method of drilling and simultaneously driving of 200mm dia. ERW casing pipe after providing fixing of casing drive shoe with first 200mm dia. ERW casing pipe, complete, as per IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipment tools plants and machineries required for the job, all complete as per direction of Engineer-in-charge. (ERW casing pipe shall be shall be paid separately)

80

8200

656000

... More
Supplying, assembly (including welding), lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel beveled ended 200mm dia. casing pipes, conforming to IS: 4270 of reputed and approved make, including painted with outside surface with two coats, of anticorrosive paint of approved brand and manufacture including required hire and labour charges, fitting and accessories, all complete for all depths, as per direction of Engineer-in-charge. Detail of specification of pipe is reflected at Annexure “A” of the SBD. The cost includes transportation, loading, unloading and stacking/handling at site all complete )

80

4500

360000

... More
Development to tube well in accordance with IS: 2800 (part 1) and IS: 11189 to establish maximum rate of usable water yield without sand content (beyond permissible limit) with required capacity air compressor, running the compressor for required time till Well is fully developed measuring yield of well by “V” notch method or any other approved method, measuring static level &draw down etc. by step draw down method collecting water samples and getting tested in approved laboratory, I/C disinfection of tube well, all complete including required hire and labour charges of air compressor tools and accessories, etc. all, as per direction of Engineer-in-charge.

1

140000

140000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.