Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Eprocure
Opening Date13 Jan 2025
Closing Date18 Jan 2025
Tender Amount₹ 1,39,97,000 
Notes
Download

Costs

Summary

Successful Testing And Commissioning

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Ordinary Rock

143.25

493

70693.88

... More
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All Kinds of soil.

262.5

592

155636.25

... More
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material :1st lift

131.25

89

11779.69

... More
Providing and laying stone soling tightly hand packed under foundations footing etc. including carriages of materials from source to site of work complete in all respects.

23.03

1320

30402.24

... More
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:

-

-

-

... More
1:4:8( 1 cement: 4 coarse sand: 8 graded stone agg/ 40mm nominal size) crushed aggregate)

13.18

5202

68553.41

... More
1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) crushed aggregrate

61.81

5733

354370.88

... More
Providing and laying in position reinforced cement of specified grade of concrete including curing but excluding the cost of centering and shuttering, finishing and reinforcement. All works upto plinth level

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

17.46

7788

136016.62

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.

24.11

9395

226559.69

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).

2.99

9821

29328.04

... More
Reinforced cement concrete work in arches, arch ribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).

6.4

10404

66616.44

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .

5606.21

123

690685.32

... More
Centring and shuttermg including strutting, propping etc. and removal of form for·

-

-

-

... More
Foundations: footings, bases of columns etc. for mass concrete.

107.31

286

30726.79

345.15

628

217078.95

... More
Edges of slabs and breaks in floors and walls.(UNDER 20 CM WIDE)

4.03

262

1056.67

... More
Lintels, beams, plinth beams, girders, bressumers and centilevers.

15.96

577

9217.12

... More
Suspended floors, roofs, landings, balconies and access platform..

4.03

718

2894.35

... More
Arches,domes,vaults upto 6m span.

50.41

2281

114998.14

... More
Extra for arches, domes, vaults exceeding 6 m span

50.41

1118

56402.63

... More
Extra for shuttering in circular work (20% of respective centering and Shuttering items)

-

-

-

... More
Foundations: footings, bases of columns etc. for mass concrete.

7.07

57

404.61

170.35

125

21427.7

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers.

15.96

115

1843.42

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.

2223.85

218

485689.28

... More
Fabricating, Providing and fixing MS Fittings viz Bends , Tees, etc of required degree and size to be fabricated from 6mm nominal size MS Plate including cost of welding. The work should be leak proof and includes to be painted with antoiccorrusive red oxide primer and all carriages upto site of work complete.

350

220

77000

... More
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 ( 1 cement : 3 fine sand).

245.09

370

90867.58

... More
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded

160

138

22112

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

1742.66

120

210513.69

... More
12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand)

166.6

266

44348.92

... More
Providing and fixing G. I. chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per direction of Engineer-in-charge. Made of G. I. wire of dia 4mm.

176.4

809

142866.36

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angles 40x40x6mm for diagonal braces

12.5

5493

68673.75

... More
Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

12.5

181

2270

... More
Applying priming coat:With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works.

142.85

53

7656.89

... More
With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work (second coat)

142.85

28

4121.3

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

142.85

131

18835.1

... More
Providing and fixing of 65/80 mm dia PVC Bends for aeration of SR..

8

300

2400

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) (Light Pipe)

-

-

-

... More
100mm ø G.I =

3500

1255

4393025

... More
80mm ø G.I =

1000

878

878250

... More
65mm ø G.I =

500

745

372550

... More
50mm ø G.I =

800

532

426240

... More
40mm ø G.I =

1500

434

651975

... More
25mm ø G.I =

1200

311

374340

... More
20mm ø G.I =

2500

227

569750

... More
15mm ø G.I =

2200

179

394240

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete

-

-

-

... More
25 to 40 mm nominal bore

10

730

7302.5

... More
50 to 80 mm nominal bore

10

1387

13872.5

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)

-

-

-

... More
80 mm nominal bore

2

2605

5210.3

... More
65 mm nominal bore

2

1646

3292.1

... More
Providing and fixing D.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Confirming to IS:14846 read with latest amendments.

-

-

-

... More
80mm Dia Class-1

1

11914

11914

... More
100 mm Dia Class-1

3

14594

43782

... More
Providing and fixing of MS flanged joints (12mm thick) to double flanged GI/DI pipes including cutting of pipes, welding charges, cutting of flanges, rubber gasket, bolts, nuts including testing of joint and sorts of carriages. Complete Job.

-

-

-

... More
80mm Dia

66

1100

72600

... More
100mm Dia

400

1520

608000

... More
Providing and incorporating during construction PGI Sheet strip 0.5mm th. and 0.15 m wide including all sort of carriage etc complete job to make the construction joint water tight.

97.34

400

38936

... More
Providing and fixing D.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Confirming to IS:14846 read with latest amendments.

-

-

-

... More
200 mm dia. Class 1

3

31698

95094

... More
250 mm dia. Class 1

1

50356

50356

... More
300 mm dia. Class 1

2

62066

124132

... More
Providing and laying S&S C.I. Standard specials suitable for mechanical jointing as per IS : 13382

-

-

-

... More
Up to 300mm Dia

13

11979

155727

... More
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately).

-

-

-

... More
50mm Dia

3

5159

15477.6

... More
80mm Dia

1

6242

6242.9

... More
Carriage of materials from source to road site of work by mechanical transport including loading, unloading and stacking.

-

-

-

... More
Cement and steel (20 kms lead)

46.68

364

17008.02

... More
Sand/aggregrates(20 mm nom. Size) 30kms avg lead

165.07

520

85891.48

... More
Aggregrates(40 mm nom. Size) 30Kms Avg lead

11.86

565

6707.36

... More
Carriage of materials from dumping site to actual site of work including loading ,unloading and stacking etc. complete by manual labour for an average lead of:

-

-

-

... More
Head Load 500 mtrs

-

-

-

... More
100mm ø G.I =

3500

6

23800

... More
Pipes below 100mm Dia

25.83

340

8783.82

... More
Head Load 1000 mtrs

-

-

-

... More
Steel

7.52

340

2557.22

... More
Cement

39.16

269

10560.55

... More
Sand/aggregrates(20 mm nom. Size)

165.07

593

98030.58

... More
Aggregrates(40 mm nom. Size)

11.86

642

7612.96



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.