Public Health Engineering Department Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Water Storage And Supply
Eprocure
Opening Date29 Mar 2025
Closing Date21 Apr 2025
Tender Amount₹ 13,03,44,721 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Augmentation of water supply scheme Basholi Town under AMRUT 2.0 and Operation and Maintenance of scheme for 05 Years
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing &laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level in 1:3:6 (1 cement :3coarse sand : 6 graded stone upto 20mm thick size nominal size)

19.03

5733

109110.41

... More
Providing and laying in position weigh batched design mix M-25 grade cement concrete for reinforced cement concrete work with weigh batcher attached with concrete mixer with or without hopper at site of work, using cement content as per approved design mix, but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete including curing , improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level.

112.61

8021

903256.07

... More
Providing and laying in position weigh batched design mix M-30 grade cement concrete for reinforced cement concrete work with weigh batcher attached with concrete mixer with or without hopper at site of work, using cement content as per approved design mix, but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete including curing , improve workability without impairing strength and durability as per direction of Engineer-incharge. All works above plinth level upto floor V level.

131.14

9510

1247252.87

... More
Providing and laying in position weigh batched design mix M-25 grade cement concrete for reinforced cement concrete work with weigh batcher attached with concrete mixer with or without hopper at site of work, using cement content as per approved design mix, but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete including curing , improve workability without impairing strength and durability as per direction of Engineer-incharge. All works above plinth level upto floor V level.

23.07

9412

217135.99

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete level. Thermo -Mechanically Treated bars of grade Fe-500 or more Qty. Vide item M30 below G/LQty. Vide item M30 above G/L

24000

123

2956800

... More
Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth including curing in: Cement mortar 1:6 (1 cement: 6 coarse sand)

39.85

7571

301726.27

... More
Extra for Brick work with common burnt clay bricks in superstructure above plinth level up to floor V level

39.85

1455

58007.65

... More
Centering and shuttering including strutting, propping etc and removal of form work for foundation, footings, base for columns etc for mass concrete .

365.03

286

104526.34

... More
Centering and shuttering including strutting, propping etc and removal of form work for Lintels Beams, plinth beams, girders , bresssumers and cantilevers.

242.69

577

140165.61

... More
Centering and shuttering including strutting, propping etc and removal of form work for Walls(any thickness) including pilasters, butresses,plinth and string courses etc.

1064.74

628

669668.22

... More
Centering and shuttering including strutting, propping etc and removal of form work for Supended floors, roofs, landings , balconies and access platforms

203.3

718

146010.06

... More
Edges of slabs and breaks into floor & walls under 20 cm wide

283.16

262

74244.55

... More
12mm thick cement plaster of mix 1 : 4 (1 cement : 4 Coarse Sand)

625.27

283

177451.63

... More
Finishing exterior & Interior with Water proofing cement paint of approved brand and manufacture to give an even shade new work(Two or more coats applied@3.84kg/10Sqmt)

898.08

98

88685.4

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using flats 30x6mm for diagonal braces and central cross piece.

16.57

5338

88458.95

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

2000

181

363200

... More
Providing & fixing of 32mm dia Gipipe for railing of stairs & gallery

150

384

57600

... More
Painting with synthetic enameled paints of approved brand and manufacture to give an even shade two or more coats on new work over an under coats of suitable shade with ordinary paints of approved brand and manufacture.

98.94

194

19258.67

... More
Filling available earth (excluding rock) in trenches,plinth,sides of foundation etc.in layer, not excluding 10cm in depth consolidated each layer by ramming and watering lead up to 50 mtr and lift up to 1.5 mtr

150

218

32760

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement basedhigh polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints .(Size 600 x 600 mm)

70.89

1490

105629.64

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete

88.79

1229

109131.79

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement:3sand:6graded stone aggr. 20mm nominal size) well rammed and consolidated and grouted with fine sand incl. finishing the top smooth.

61.06

572

34975.17

... More
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 110 mm diametre

25

366

9157.5

... More
Providing, stacking and Filling of graded stone agg. (Filter Media) of size 1.5 -4mm, 6-12mm, 12-20mm, 20- 40mm, 40-65mm in five layers (Nallah) including carriage from source to be indentified by Engineer Incharge.

14.91

2000

29820

... More
Supply of Silica sand as filter media of size 0.45 mm-0.7 mm having uniform co-efficient 1.3-1.75 and should be free from dust and other organic and inorganic impurities including carriage from source i.e Calcutta west Bengal

8.95

25000

223750

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329 300 mm dia Ductile Iron Double Flanged

40

5277

211086

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329 200 mm dia Ductile Iron Double Flanged

80

2895

231648

... More
Providing and laying D.I Specials of Clas K-12 suitable for push on jointing as per IS 9523 Up to 600 mm dia

6

17971

107829.9

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately).of dia 300mm class-II

6

27485

164911.8

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately).of dia 200mm class-II

6

13496

80978.7

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately).of dia 150mm class-II

4

6642

26570.2

... More
Providing and Fixing of 80 mm dia PVC under drainage lateral 80mm thick fabricated out with 9mm perforations as per design in the provided at 60" along with PVC/RCC, Tees and end caps to be grouted in M-25 grade cement con. At ends the pressure rating 10Kg/Cm2

90

500

45000

... More
Providing and fixing of air blower (Everest make or kay make) capable for providing compression @ 225 cum per minute @ 0.35 kg/Sqm with suitable 3 phase induction motor with auxilary pipe system upto filter bds fitting prssure guge nozzels cement black base plate air check valves, non return valves, cement conc black in M-20 grade foundation bolt base frame fabricated out at 100mm MS channels, the job also includes PRV Pipe and Pipe fittings shurters and PVC 19/28 coper wive complete job & other elctrical controlling devices fitted on panel board complete Job along with stand by Blower.

1

300000

300000

... More
Providing installation testing commissioning of monoblock pumping equipment capable of lifting of 35 cum per hour for a height at 20 m with 3 phse appropriate rate power induction moves with sturter assembly suction and delivery pipe and pipe fittings of required sec. upto back was tank, the job inc; all eclectrical operating devices fitted on pannel borad along with stand by motor

1

150000

150000

... More
Providing and Fixing of mechanical equipemnt required for Alum solution tank with electrically driven Paddle asembly fitted with suitable reduction gear mechasism upto point of application in the flash mixer along with washout arragnements plus 25mm dia GI inlet water line from back was tank to alum with GI pipe specials and gate valve CB Galss pipe in electrical operating device complete Job

1

100000

100000

... More
Providing installation testing commissioning of flash mixer assembly suitable for a dia 0.70 m comprising of SS chunners with verticle tyupe hollow shaft prime moves 3 phase 150 RPM. The Job includes constent bleed assembly with reduction gear box and operational gear to regulate the bleed. complete Job

1

100000

100000

... More
Providing installation testing commissioning of 3 phase oil immersed 30 KVA voltage stabilizer (servo make) capable to perate incoming voltae of 180 volt and outgoing voltage at 410+-10% volt complete Job

1

250000

250000

... More
Providing and laying of 4 crore 50 mm Aluminum cable to be laid as service line from nearest LT Pole upto main Pannel board incl. to be laid under ground

70

500

35000

... More
Provding installation testing commissioning of 100 Amp dust/moisture Proof cubical pannel fitted with 3 phase 100 Amp MCCB l&T make 02 no. and 65 Amp single phase MCCB fr lighting and heating systems. The job also includes no. amp metre 0.100 AE make with CT coips and one number voltmetre AE make 0.500 with selector switches, L&T make and 3 No. indicator lamps Neon type complete Job.

1

80000

80000

... More
Providing and fitting concealed internal Electrification of room including 12 Nos LED lights, Fan points 2 No., Fuse box 1 No., 6 no 15 Amp sockets with switch, 5 Amp 4 no. sockets with switch - of approved brand and 04 nos LED security lights 30 watts, Main switch with complete wiring, with MS bracket for pole mounting complete including service line upto a length of 10 meters. including under grond conduct pipes, wiring, steel boxes and switches for 12 No. light Points (internal) with holder and LED bulbs and external 4 Nos. with LED Security lights with required M.S Bracket for mainting (external grade) complete as directed by Engineer incharge. including necessary earthing as per electrical schedule manual.

1

100000

100000

... More
Providing and fitting of Automated bleaching doser pump along with all necessary acessories including Provision for constant dozing of bleaching along with required arrangement i.e motor, switches, starter/Automatic panel etc. (complete Job) along with stand by unit.

1

100000

100000

... More
Providing and fixing of MS rotating bridge fabricated IS 50x50x6mm angle suitable for bearing silt of PST (dia) 5.3m. The Job including cerival bearing assembly shaft and MS Wheels, Stop Wheels and deflector draft tube fabricated out of MS Sheet with Proper Proforatin as per site requrement, including placing in position with adequate rotating prime moves 3 phase 440 volt 50Hz inc. fly sheel and MS rail, on fish plate grouted on top base of PST in cement concrete. The Job ncludes provding and installation of 3 phase cubical electrical panel 63 Amp capcity with appropriate ratingt 3 hase MCCB/OCB and Automatic panel of electrical motors incl. connecting eith electrical PVC copper cable and on poll system. The Job includes fabriation and fitting f scraper blades fabricated out of 50x50x6mm angle & 3mm thick sheet including assembly with rotating system and central shaft.

1

200000

200000

... More
Providing and fixing of MS rotating bridge fabricated IS 50x50x6mm angle suitable for bearing silt load of flocculater (dia) 2.20m. The job including central bearing assembly shaft and MS wheels. Stop wheels and deflector draft tube fabricdated out of MS Sheet with proper prtoraction as per site requirement, including placing in postion with adequiate rotating prime movers 3 phase 440 vlot 50 Hz incuding fly sheel and MS rail on fish plate grouted on top bse of floculator in cement concret. the job includes, providing and installation of 3 phase cubical electrical panel 63 Amp capacity with approprriate roting 3 phse MCCB/OCB and panel of electrical motors incl. connecting with electrical PVC copper cable and on poll system. the jb inc. fabrication and fitting of scrapper blades fabricated out of 50x50x6mm angle and 3mm thick sheet including assembly with rotatry system and central shaft. the job including providing of paddle blades on the central shaft assembly fabricated out of 50x50x6mm angle above the draft tube.

1

160000

160000

... More
Providing and fixing of MS Rotatry bridge fabricatee IS 50x50x6mm angle suitable for bearing silt load of clarifier (dia 4.40m). The Job incuding central bearing assembly shaft and MS Sheels, stop wheels and detlector draft tube fabricatd out of MS sheets with proper Proforation as per site requirement, including placing in position with adequate rotating prime mover 3 phase 440 volt 50 Hz including fly wheel and MS Rail on fish plate grouted on top base of clarifier in cement concrete. The Job includes providing and installation of 3 phase cubical electrical panel 63 Amp capacity with appropriate rating 3 phase MCCB/OCB and panel of electrican motors incl. connecting with electrical PVC copper blades fabricated out of 50x50x6m angle & 3mm thick sheet incl. assembly with rotating system and central shaft.

1

150000

150000

... More
Providing & Fixing & 50mm dia PVC pipe for orifices in PST, Fludden & clarifier for collection of water in channels (20+20+10) = 50 No's

60

40

2400

... More
Providing & Fixing & ROF (Rate of flow metre) including assembly & Testing

1

20000

20000

... More
Carriage of Sand and stone aggregate upto 20mm by Mechanical Transport incl. loading, unloading and staking..for an av. distance of 50 KM

432

741

320172.48

... More
Carriage of Bricks from brick klin by Mechanical Transport incl. loading, unloading and staking..for an av. distance of 100 km

18.93

3447

65262.12

... More
Carriage of Cement from division head quarterf by Mechanical Transport incl. loading, unloading and staking.for an av. distance of 05 KM

123.73

178

22077.14

... More
Carriage of steel from division head quarter by Mechanical Transport incl. loading, unloading and staking.for an av. distance of 05 KM

24

178

4282.32

... More
Carriage (Head Load) for Sand, stone aggregate below 40 mm nominal size. up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

432

593

256556.16

... More
Carriage (Head Load) for Bricks up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

18.93

1108

20986.18

... More
Carriage (Head Load) for Cement up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

123.73

269

33366.27

... More
Carriage (Head Load) for Steel up to a lead of 500 m by Manual Labour including loading, unloading and stacking

22.68

579

13138.07

... More
Construction of 20000 glns GSR (02 nos.) Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :

196.7

256

50522.4

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

17.3

5202

90010.17

... More
Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level

23.2

8021

186089.52

... More
Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V level

35.66

9412

335633.7

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately. Providing M- 30 grade concrete instead of M-25 grade BMC/RMC Qty same as item no 3 and 4 (11.6+17.83=29.43 Cum)

58.86

98

5815.37

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo- Mechanically Treated bars of grade Fe-500D or more. qty of steel for raft ,walls and dome @100 Kg /Cun

5000

123

616000

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete. For raft

8.54

286

2445.43

... More
Extra for shuttering in circular work (20% of respective centering and Shuttering items) Qty same as item no- 7 = (4.27 Sqm)

8.54

57

489.09

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. For walls

154.58

628

97223.09

... More
Extra for shuttering in circular work (20% of respective centering and Shuttering items) Qty same as item no- 9 = (77.29 Sqm)

154.58

125

19444.62

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers. For outer ring beam

11.5

577

6641.83

... More
Extra for shuttering in circular work (20% of respective centering and Shuttering items) Qty same as item no- 11 = (5.75 Sqm)

11.5

115

1328.37

... More
Arches, domes, vaults upto 6 m span For Dome

70.06

2281

159820.87

... More
Extra for arches, domes, vaults exceeding 6 m span Qty as per item no -13 = 35.03 Sqm

70.06

1118

78386.63

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

250

181

45400

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) For plinth protection

4.8

5733

27521.28

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate For plinth protection

45.24

562

25431.67

... More
CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)

390.16

283

110727.41

... More
Providing and laying S&S Centrifugally Cast (Spun)/ Ductile Iron Pipes conforming to IS : 8329. 200 mm dia. DI-K9 for wash out

50

2980

149045

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement) Qty of cement as per item no-5= say 220 bags

440

63

27720

... More
Providing and fixing G.I.bends150 mm dia with MS plate including cutting ang welding extra with distribution washout

8

1200

9600

... More
Providing and fixing of AC plain bends with accessdor of size 100 mm dia

12

500

6000

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)

247.24

98

24414.95

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. For sides of GSR

5.44

218

1188.1

... More
Carriage of Sand, stone aggregate below 40 mm nominal size up to a lead of 50 Km by Mechanical Transport incl. loading, unloading and staking.

114.1

741

84564.07

... More
Carrige of Cement and Steel lead up to 05 Km by Mechanical Transport incl. loading, unloading and staking

35.98

178

6419.91

... More
Carriage (Head Load) for Sand, stone aggregate below 40 mm nominal size. up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

114.1

593

67761.71

... More
Carriage (Head Load) for Cement up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

30.1

269

8117.07

... More
Carriage (Head Load) for Steel up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

5.88

579

3406.17

... More
Construction of Operator Room With Toilet Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

0.2

1249

249.82

... More
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :

30.62

256

7864.75

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

3.71

5202

19302.76

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

18.43

5733

105670.25

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

9

7788

70095.6

... More
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete

6.5

416

2707.25

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand)

30.21

7571

228736.53

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

30.21

1455

43975.19

... More
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1cement : 3 coarse sand)

9

981

8833.5

... More
CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix: 1 : 4 ( 1cement : 4 fine sand)

213.37

283

60554.41

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintel, beams, plinth beams, girders, bressumers and cantilevers

28.28

577

16333.11

... More
Suspended floors, roofs, landings, balconies and access platforms

46.72

718

33554.3

... More
Foundations, footings, bases of columns etc. for mass concrete.

70.54

286

20199.13

... More
Edges of slabs and breaks in floors and walls Under 20 cm wide

27.36

262

7173.79

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.

795

123

97944

... More
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion 110 mm diametre

3

366

1098.9

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing withcement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase

27.36

241

6606.07

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

1

262

262.9

... More
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in- charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin- charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm

34.95

1404

49092.52

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer

213.37

164

35120.7

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately). For fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns)

33.54

514

17250.39

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately). For shutters of doors, windows & ventilators including providing and fixing hinges I pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Powder coated aluminium (minimum thickness of powder coated 50 microns)

32.85

607

19953.82

... More
Providing and fixing 12mm thick prelaminated particle boardflat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-l type- 11) in panelling fixed in aluminium doors, windows shutters and partition frames with C. P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.

3.65

947

3458.01

... More
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm)

1.94

1061

2060.18

... More
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. Complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminum

6

95

575.1

... More
Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100 x 10 mm

3

63

190.05

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete.

1

747

747.1

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of tile 500x500 mm

5

1312

6564.25

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate

42.25

562

23750.84

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

28.36

1106

31367.58

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C . .pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures, complete including cutting and making good the walls and floors wherever requied: W.C. pan with lSI marked white solid plastic seat and lid.

1

5632

5632.4

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

1

4172

4172.4

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink: Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms.

1

623

623.1

... More
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 )

3

582

1747.05

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.

1

248

248.45

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

1

287

287.5

... More
Providing and fixing mirror of superior glass( of approved quality) and of required shape and size with plastic . moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm

1

1156

1156.25

... More
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 15 mm nominal bore

4

583

2333

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting chases and making good the wall etc. 15mm nominal outer dia pipes

15

419

6296.25

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455 x 610 mm and 45 cm deep for single pipe line

2

6341

12682.9

... More
Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.

1

23815

23815.8

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x510mm bowl depth 200mm

1

4380

4380.5

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

1000

8

8750

... More
Carriage of Sand, stone aggregate below 40 mm nominal size up to a lead of 50 Km by Mechanical Transport incl. loading, unloading and staking.

52.95

741

39243.36

... More
Carrige of Cement and Steel lead up to 05 Km by Mechanical Transport incl. loading, unloading and staking

11.72

178

2091.2

... More
Carriage (Head Load) for Sand, stone aggregate below 40 mm nominal size. up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

52.95

593

31445.95

... More
Carriage (Head Load) for Cement up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

10.92

269

2944.8

... More
Carriage (Head Load) for Steel up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

0.8

579

463.42

... More
Carriage of Bricks from brick klin by Mechanical Transport incl. loading, unloading and staking..for an av. distance of 100 km

15

3447

51713.25

... More
Carriage (Head Load) for Bricks up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

15

1108

16629.3

... More
Supply, Installation. Testing & Commissioning LED Flood Light Luminaire oquipped with specially designed heat sink, High performance electronic driver ensures zero, rnaintenance, High Surge Protection: 4KV, Average life L70B50. 50,000 hrs., Operating temperature:-10°C to +46°C Power 60W, Flux 4,2601m,Dimension(mm) |220X60X311,Welght 1,.8kg

8

1233

9869.6

... More
Supply, Installation, Testing & Commissioning Aesthetically designed |higher wattage LED Bulb for B22 lamp base, Input Voltage: AC 220-240V, 50/60Hz, Driver Type: Integral, Lumen output 1060 Im, (12 Watt LED Bulb)

18

113

2049.84

... More
Supply & Fixing of Pvc conduit of size 25 mm for cable laying

4

1898

7592

... More
Supply, Installation of Saddle block 25 mm for fixing of conduit pipes

10

94

949

... More
Supply & fixing of 8 Way Gang box

6

94

569.4

... More
Supply, & fixing of 6 amp. Switch

38

71

2704.65

... More
Supply, Laying & Termination of 1.5 Sqmm wire for lighting

540

23

12811.5

... More
Supply, Laying & Termination of 2.5 Sqmm wire for lighting

180

33

5978.7

... More
Supply & fixing of Screws1 inch & 1.5 inch for fixing of electric Fixtures

10

56

569.4

... More
Supply & Fitting of Rawal plugs for fixing of Electrical fixtures

10

56

569.4

... More
Supply & Fitting of Pandent Holders for fixing of LED Blubs

10

47

474.5

... More
Supply & Fiting of Angle Holders for fixing of LED Blubs

10

66

664.3

... More
Supply & Fitting of Fan dimmer for control of ceiling fan

2

272

544.58

... More
Supply & Fitting of 6 Amp 3- pin socket

2

237

474.5

... More
Supply & Fitting of Square Block for fixing of Switches, Sockets

2

189

379.6

... More
Supply, Laying & Termination of 3.5 core 4 Sqmm copper armond wire for pump to panel

100

189

18980

... More
Supply, Laying & Termination of 3.5 Core 50 sqmm wire for Feeder to transformer

120

332

39858

... More
Construction of Pump Room  Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

0.2

1249

249.82

... More
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :

19.8

256

5085.63

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

2.54

5202

13215.37

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

11.54

5733

66165.74

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and inforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

6.76

7788

52649.58

... More
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete

4.14

416

1724.31

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand)

18.64

7571

141133.69

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

18.64

1455

27133.32

... More
CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)

125.06

283

35492.03

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintel, beams, plinth beams, girders, bressumers and cantilevers

18.02

577

10407.45

... More
Suspended floors, roofs, landings, balconies and access platforms

29.7

718

21330.54

... More
Foundations, footings, bases of columns etc. for mass concrete.

44.14

286

12639.49

... More
Edges of slabs and breaks in floors and walls Under 20 cm wide

21.9

262

5742.18

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo- Mechanically Treated bars of grade Fe-500D or more.

588.6

123

72515.52

... More
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion 110 mm diametre

3

366

1098.9

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing withcement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase

21.9

241

5287.75

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

1

262

262.9

... More
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in- charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin- charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm

34.95

1404

49092.52

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer

125.06

164

20584.88

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) for fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns)

24.43

514

12562.29

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately). For shutters of doors, windows & ventilators including providing and fixing hinges I pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Powder coated aluminium (minimum thickness of powder coated 50 microns)

25.7

607

15610.18

... More
Providing and fixing 12mm thick prelaminated particle boardflat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-l type- 11) in panelling fixed in aluminium doors, windows shutters and partition frames with C. P. brass I stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.

1.15

947

1089.51

... More
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm)

1.76

1061

1869.03

... More
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. Complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminum

6

95

575.1

... More
Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100 x 10 mm

3

63

190.05

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

192.2

120

23217.76

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete.

1

747

747.1

... More
Carriage of Sand, stone aggregate below 40 mm nominal size up to a lead of 50 Km by Mechanical Transport incl. loading, unloading and staking.

34.76

741

25762.03

... More
Carrige of Cement and Steel lead up to 05 Km by Mechanical Transport incl. loading, unloading and staking

7.87

178

1404.24

... More
Carriage (Head Load) for Sand, stone aggregate below 40 mm nominal size. up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

34.76

593

20643.27

... More
Carriage (Head Load) for Cement up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

7.28

269

1963.2

... More
Carriage (Head Load) for Steel up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

0.59

579

341.78

... More
Carriage of Bricks from brick klin by Mechanical Transport incl. loading, unloading and staking..for an av. distance of 100 km

9

3447

31027.95

... More
Carriage (Head Load) for Bricks up to a lead of 500 m by Manual Labour including loading, unloading and stacking.

9

1108

9977.58

... More
50000 Glns OHT Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts,wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :

215.4

187

40344.42

... More
Earth work in bulk excavation by manual means over areas (exceeding 30 cm indepth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earthlead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil

141.04

592

83622.62

... More
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil :

141.04

89

12658.34

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level with 1:4:8 (1 cement : 4 Sand : graded stone agg. upto 40mm niminal size)

17.68

5202

91987.27

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve5.0 (REINFORCED CEMENT CONCRETE) 99 CODE NO.DESCRIPTION UNIT RATE ₹ workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level

105.94

8021

849755.33

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve5.0 (REINFORCED CEMENT CONCRETE) 99 CODE NO.DESCRIPTION UNIT RATE ₹ workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V level

91.27

9412

859056.63

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately.1 Providing M-30 grade concrete instead of M-25 grade BMC/RMC.

197

98

19463.6

... More
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

10.09

10377

104705.44

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo -Mechanically Treated bars of grade Fe-500 or more

26109.5

123

3216690.4

... More
Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete

27.25

286

7803.04

... More
Extra for shuttering in circular works(20%)

8.11

57

464.46

... More
Centering and shuttering including strutting, propping etc. and removal of form for: slab Columns, pillars, piers, abutments, posts and struts.

215.16

742

159767.06

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.

68.97

577

39833.62

... More
Centering and shuttering including strutting, propping etc. and removal of form for: slab Suspended floors, roofs, landings, balconies and access platforms

103.32

718

74204.42

... More
Centering and shuttering including strutting, propping etc. and removal of form for:Stairs (excluding landings) except spiral staircases.

30.78

851

26198.4

... More
Centering and shuttering including strutting, propping etc. and removal of form for:Arches, domes, vaults upto 6 m span

68.82

2281

156992.18

... More
Extra for shuttering in circular works(20%)

68.82

456

31398.44

... More
Centering and shuttering including strutting, propping etc. and removal of form for:Chimney and shafts

313.87

628

197408.54

... More
Extra for shuttering in circular works(20%)

313.87

125

39481.71

... More
Edges of slabs and breaks in floors and walls Under 20 cm wide

67.34

262

17656.55

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40x40x6mm for diagonal braces

5

5493

27469.5

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.G.I. pipes

1500

197

296175

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level with 1:3:6 (1 cement : 3 Sand : graded stone agg. upto 20mm niminal size)

2.18

5733

12499.25

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.

42.43

562

23852.02

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.(1 kg of water proofing material in 50 kg of cement)

1658.42

63

104480.46

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)

587.32

98

57997.85

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329 100 mm dia Ductile Iron Double Flanged

96

1530

146937.6

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329 150 mm dia Ductile Iron Double Flanged

24

2295

55095.6

... More
Providing and laying D.I. Specials of Class K-12 suitable for mechanical jointing as per IS : 9523 Upto 600 mm dia.

5

17971

89858.25

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately).100 mm dia class -II

4

4453

17815.4

... More
Providing and fixing of lightning conductor complete job along with fixing of Aluminum strips and earthling which includes digging of a pit in the earth which should not be less than 3m (10ft) from the ground level . A plate made up of Aluminium with dimensions 60cm x 60cm x 3.18mm is buried vertical in the earth (earth pit) which should not be less than 3m (10ft) from the ground level and connecting al. strip of 32mm x 5mm along with nuts and bolts inside the pit with the earthing plate and extending the strip up to the machinery. Put about 30 cm layer of powdered charcoal and salt around the earth plate in alternate layers up to 06 feet . Providing and fitting of 25 mm dia GI pipe for putting water inside the pit to maintain moisture. The job also includes the construction of chamber made of brick masonary with CI cover 45 cm x 45 cm. The job includes the cost of material, labour, transport charges , testing and any other miscellaneous charges.(Note: The distance between the two earth should not be less than 06 mtrs). Complete job as per scope of work in SBD. Earthing and other allied works

1

60000

60000

... More
Supply , installation and commissioning of level transmitter in sump and overhead tanks, Ultrasonic type having range ( 0-8m) with 24-48VDC connections including cabling, conduiting as per technical specifications complete

1

80000

80000

... More
Carriage of Sand, stone aggregate below 40 mm nominal size up to a lead of 50 Km by Mechanical Transport incl. loading, unloading and staking.

291.41

741

215975.61

... More
Carrige of Cement and Steel lead up to 05 Km by Mechanical Transport incl. loading, unloading and staking

149

178

26586.07

... More
Carriage (Head Load) for Sand, stone aggregate below 40 mm nominal size. up to a lead of 100 m by Manual Labour including loading, unloading and stacking.

291.41

244

71208.95

... More
Carriage (Head Load) for Cement up to a lead of 100 m by Manual Labour including loading, unloading and stacking.

128.09

133

17070.55

... More
Carriage (Head Load) for Steel up to a lead of 100 m by Manual Labour including loading, unloading and stacking.

21.32

286

6102.64

... More
Carriage of Bricks from brick klin by Mechanical Transport incl. loading, unloading and staking..for an av. distance of 100 km

1.1

3447

3792.31

... More
Carriage (Head Load) for Bricks up to a lead of 100 m by Manual Labour including loading, unloading and stacking.

1.1

456

501.75

... More
30000 glns capacity OHT Earth work in bulk excavation by manual over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth lead up to 50 meters and lift up to 1.5m, as directed by Engineer-in-Charge. All kinds of soil .

125.58

592

74456.38

... More
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth lead up to 50 meters and lift up to 1.5m, as directed by Engineer-in-Charge. All kinds of soil Mech.

188.36

187

35279.83

... More
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material in all kinds of soil.

80.21

89

7198.85

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level with 1:4:8 (1 cement : 4 Sand : graded stone agg. upto 40mm niminal size)

11.49

5202

59781.32

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level with 1:3:6 (1 cement : 3 Sand : graded stone agg. upto 20mm niminal size)

11.49

5733

65879.06

... More
Providing and laying in position weigh batched design mix M-25 grade cement concrete for reinforced cement concrete work with weigh batcher attached with concrete mixer with or without hopper at site of work, using cement content as per approved design mix, but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete including curing , improve workability without impairing strength and durability as per direction of Engineer-in charge. All works up to plinth level.

80

8021

641688

... More
Providing and laying in position weigh batched design mix M-25 grade cement concrete for reinforced cement concrete work with weigh batcher attached with concrete mixer with or without hopper at site of work, using cement content as per approved design mix, but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete including curing , improve workability without impairing strength and durability as per direction of Engineer-in charge. All works above plinth level.

49.89

9412

469567.17

... More
Extra fro providing richer mix at all floor levels

129.89

98

12833.13

... More
Reinforcement cement concrete work in Arches, arch ribs, domes, vaults shells, folded plate and roofs having slope more than 15° up to floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with 1:1½:3 (1cement : 1½ coarse sand: 3 graded stone aggregate 20mm nominal size)

3.93

10377

40782.2

... More
Providing and laying in position weigh batched design mix M-25 grade cement concrete for reinforced cement concrete work with weigh batcher attached with concrete mixer with or without hopper at site of work, using cement content as per approved design mix, but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete including curing , improve workability without impairing strength and durability as per direction of Engineer-in charge. All works above plinth level.

14.43

9412

135815.88

... More
Centering and shuttering including strutting, propping etc and removal of form work for foundation, footings, base for columns .

32.11

286

9194.7

... More
Extra for shuttering in circular works

32.11

57

1838.94

... More
Centering and shuttering including strutting, propping etc and removal of form work for Columns, pillars,piers,abbutmentstsand struts.

178.2

742

132322.41

... More
Centering and shuttering including strutting, propping etc and removal of form work for Lintels Beams, plinth beams, girders , bresssumers and cantilevers.

88.42

577

51066.97

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Arches, domes, vaults up to 6 mtrs span.

65.03

2281

148346.44

... More
Centering and shuttering including strutting, propping etc and removal of form work for Walls(any thickness) including pilasters, butresses,plinth and string courses etc.

217.32

628

136683.41

... More
Extra for shuttering in circular works

217.32

125

27336.68

... More
Centering and shuttering including strutting, propping etc and removal of form for Suspended floors, roofs, landings, balconies and access platforms.

117.68

718

84517.78

... More
Extra for shuttering in circular works

117.68

143

16903.56

... More
Centering and shuttering including strutting, propping etc. and removal of form for edges of slabs and breaks in floors and walls under 20 cm wide

169.86

262

44537.29

... More
Extra for Reinforced cement concrete work in super structure above floor 5 level for each four floor or part thereof

39.91

280

11212.71

... More
Extra for additional height in centering and shuttering for every additional height of 1 meter or part thereof above 3 meter (plan area to be measured)

-

-

-

... More
Lift 1

10

293

2939

... More
Lift 2

10

587

5878

... More
Lift 3

10

881

8817

... More
Lift 4

10

1175

11756

... More
Lift 5

10

1469

14695

... More
Lift 6

10

1763

17634

... More
Lift 7

10

2057

20573

... More
Lift 8

10

2351

23512

... More
Lift 9

10

2645

26451

... More
Lift 10

10

2939

29390

... More
Lift 11

10

3232

32329

... More
Lift 12

10

3526

35268

... More
Lift 13

10

3820

38207

... More
Lift 14

15

4114

61719

... More
Lift 15

50

4408

220425

... More
Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth including curing in: Cement mortar 1:6 (1 cement: 6 coarse sand)

5.29

7571

40053.5

... More
Extra for Brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level up to floor five level

5.29

1455

7700.39

... More
12 mm cement plaster fix with a floating coat of neat cement of mix 1:3 ( 1 cement : 3 coarse sand)

137.57

370

51004.08

... More
12mm thick Cement plaster or rough side of single or half brick wall of mix : 1:4 ( 1 cement : 4 coarse sand)

92.65

353

32714.72

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo -Mechanically Treated bars of grade Fe-500 or more

17049

123

2100436.8

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

1787.19

181

324553.7

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mmangle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using flats 30x6mm for diagonal braces and central cross piece.

3.68

5493

20217.55

... More
Providing and fixing G.I. pipes complete 32 mm dia. nominal bore including welding for railing works

100

384

38400

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.(1 kg of water proofing material in 50 kg of cement)

157.92

63

9948.96

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of tile 800x800 mm

11.31

1857

21012.85

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work

67.69

131

8924.93

... More
Finishing walls with water proofing cement paint of required shade on new work (two or more coats) applied @ 3.84 Kg/10 Sqm

550

98

54312.5

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

188.36

218

41137.82

... More
Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) 100 mm dia C.I. Double Flanged Pipe

90

1825

164308.5

... More
Providing and laying D.I. Specials of Class K-12 suitable for mechanical jointing as per IS Upto 600 mm dia

4

17971

71886.6

... More
Providing & fixing CI Double Flanged manually operated Sluice Valve (with cap wheels) as per specifications (IS:14846) for control purpose in proposed pipe of following dia including jointing material (bolts, nuts, gaskets, washers, rubber insertions etc.) complete including testing. 1.6 MPa(16 kg/cm2) 100 mm dia

4

4453

17815.4

... More
Providing and fixing of lightning conductor complete job along with fixing of Aluminum strips and earthling which includes digging of a pit in the earth which should not be less than 3m (10ft) from the ground level . A plate made up of Aluminium with dimensions 60cm x 60cm x 3.18mm is buried vertical in the earth (earth pit) which should not be less than 3m (10ft) from the ground level and connecting al. strip of 32mm x 5mm along with nuts and bolts inside the pit with the earthing plate and extending the strip up to the machinery. Put about 30 cm layer of powdered charcoal and salt around the earth plate in alternate layers up to 06 feet . Providing and fitting of 25 mm dia GI pipe for putting water inside the pit to maintain moisture. The job also includes the construction of chamber made of brick masonary with CI cover 45 cm x 45 cm. The job includes the cost of material, labour, transport charges , testing and any other miscellaneous charges.(Note: The distance between the two earth should not be less than 06 mtrs). Complete job as per scope of work in SBD. Earthing and other allied works

1

60000

60000

... More
Supply , installation and commissioning of level transmitter in sump and overhead tanks, Ultrasonic type having range ( 0-8m) with 24-48VDC connections including cabling, conduiting as per technical specifications complete

1

80000

80000

... More
Providing & installation of Sign Board of size 8ft x 6ft with angle Iron frame of size 50 x 50 x 6 mm PBI sheet of 1.25mm thickness including painting and writing as directed by Engineer- In- charge. The Job also includes writing with black paint on the storage tank depicting capacity and other feature of the OHT

1

14000

14000

... More
Carriage of Sand, stone aggregate below 40 mm nominal size by M.T through an av. Lead up to 50 km

243.01

741

180104.43

... More
Carriage of Sand, stone aggregate below 40 mm nominal size by H.L through an av. Lead up to 100 mtrs

243.01

244

59381.92

... More
Carriage of Cement by Mech. Trans. Through an av. lead up to 5 km Incl. loading unloading and stacking

66.06

178

11787.37

... More
Carriage of Cement by Head Load through an av. lead up to 100 mtrs Incl. loading unloading and stacking

66.06

133

8804.08

... More
Carriage of Steel by Mech. Trans. Through an av. lead up to 5 km Incl. loading unloading and stacking

17.05

178

3042.23

... More
Carriage of Steel by Head Load through an av. lead up to 100 mtrs Incl. loading unloading and stacking

17.05

286

4880.39

... More
Carriage of Brick by Mech. Trans. Through an av. lead up to 100 km Incl. loading unloading and stacking

2.89

3447

9973.76

... More
Carriage of Brick by Head Load through an av. lead up to 100 mtrs Incl. loading unloading and stacking

2.89

456

1319.61

... More
Pipe Network Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material upto a lead of 1 kilometer, as per direction of Engineer-in-charge.

270

336

90801

... More
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge.

6000

93

560400

... More
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix)

360

1725

621072

... More
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :

4514.4

256

1159523.64

... More
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil :

10700

479

5128510

... More
Providing, & fixing G.I pipes complete with G.I fitting excluding trenches and refilling etc (external work) (150mm dia) M

1300

2256

2933970

... More
Providing, & fixing G.I pipes complete with G.I fitting excluding trenches and refilling etc (external work) (100mm dia) M

11200

1434

16060800

... More
Providing, & fixing G.I pipes complete with G.I fitting excluding trenches and refilling etc (external work) (100mm dia) L

3950

1255

4957842.5

... More
Providing, & fixing G.I pipes complete with G.I fitting excluding trenches and refilling etc (external work) (80mm dia) L

6250

878

5489062.5

... More
Providing, & fixing G.I pipes complete with G.I fitting excluding trenches and refilling etc (external work) ( 25mm dia)

2500

311

779875

... More
Providing, & fixing G.I pipes complete with G.I fitting excluding trenches and refilling etc (external work) (20mm dia)

2000

227

455800

... More
Providing, & fixing G.I pipes complete with G.I fitting excluding trenches and refilling etc (external work) ( 15mm dia)

2000

179

358400

... More
Providing , laying , fixing & jointing of ISI Marked HDPE pipes are per ISI-4984-1995 casting along the Trenches and laying the samne in trenches to correct alignment and gradients , cutting, jointing and testing complete as per specifications(50 mm PN--10

2000

140

280400

... More
Providing , laying , fixing & jointing of ISI Marked HDPE pipes are per ISI-4984-1995 casting along the Trenches and laying the samne in trenches to correct alignment and gradients , cutting, jointing and testing complete as per specifications(63 mm PN--10

1300

218

284440

... More
Providing , laying , fixing & jointing of ISI Marked HDPE pipes are per ISI-4984-1995 casting along the Trenches and laying the samne in trenches to correct alignment and gradients , cutting, jointing and testing complete as per specifications(75 mm PN--10

2900

299

867100

... More
Providing and fixing of gun metal gate valve with C.I. wheel of approved quality (screwed end) 80 mm nominal bore

12

2605

31261.8

... More
Providing and fixing of gun metal gate valve with C.I. wheel of approved quality (screwed end) 65 mm nominal bore

10

1646

16460.5

... More
Providing and fixing of gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 mm nominal bore

15

986

14792.25

... More
Providing and fixing of gun metal gate valve with C.I. wheel of approved quality (screwed end) 40 mm nominal bore

15

834

12519

... More
Providing and fixing of gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore

20

691

13834

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately). ( 150 mm dia) Class-II

4

6642

26570.2

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately). ( 100 mm dia) Class-II

12

4453

53446.2

... More
Providing and fixing Non return Air calves (with cap) complete with bolts, nuts, rubber insertions etc. the tail pieces if required will be spearately ( 100 mm dia)

8

5000

40000

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with(1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

360

5733

2064096

... More
Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge

4200

280

1179990

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colou r& pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 16.93.1 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern

1800

875

1576710

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

13692.96

218

2990542.46

... More
Carriage of surplus Excavated earth and dismantled material up to alead of 02 km ny Mechnical Transport incl. loading unloading and staking & 300 Mtrs H.L

1504.8

516

776536.99

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge

540

1885

1018413

... More
Providing and applying tack coat using hot straight run bitumen of grade – VG-30, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. On W.B.M. @ 0.75 Kg/sqm.

3600

75

272700

... More
Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge.50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.5% (percentage by weight of total mix) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity

180

8734

1572273

... More
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.25 mm compacted thickness with bitumen of grade VG- 30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity

3600

298

1074600

... More
Carriage (H.L) for 500 mtrs from store to site pipe and jointing materials, pipe of all quality and following sizes lowering into trenches and jointing , testing complete

264.69

340

89997.08

... More
fabrication and installartion of Manifolds, providing and fixing of sluice valve fabrication of bends by way of welding and commissioning complete

4

80000

320000

... More
Welding of joints

130000

6

806000

... More
Carriage of Sand and stone aggregate up to 20mm by Mechanical Transport from source (to be identified by engineer in charge) to site of work/dumping place (To be identified by engineer in charge) including cost for loading and unloading. For an av. distance of 50 Km & 500 mtrs H.L

496.8

1335

663237.94

... More
Carriage of Cement by Mechanical Transport from source (to be identified by engineer in charge) to site of work /dumping place (To be identified by engineer in charge)including cost for loading and unloading. For an av. distance of 10 Km

79.2

243

19247.98

... More
Providing, & fixing G.I pipes complete G.I fitting excluding teenches and refilling etc (extranal work) Medium ( 15mm dia) for House hold connections

3600

179

645120

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore

600

730

438150

... More
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore

600

334

200820

... More
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main 15 mm nominal bore

600

348

209310

... More
Boundary Wall Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavatedearth as directed: All kinds of soil.

111.03

479

53216.68

... More
Providing and laying in position cement concrete of 1:4:8 mix (1 cement 4 coarse sand 8 graded stone agg. 40 mm nominal size) excl. cost of centring and shuttering all work up to plinth level (using crushed stone agg.)

17.85

5202

92871.77

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level in 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) (using crushed stone agg.)

68.37

5733

392006.23

... More
Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth including curing in: Cement mortar 1:6 (1 cement: 6 coarse sand)

19.02

7571

144010.88

... More
Extra for Brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

12.57

1455

18297.52

... More
Half brick masonry with common brunt clay ( non- modular) bricks of class designation 7.5 in foundation and plinth including curing in cement mortar 1:4 (1 cement : 4 coarse sand)

439.71

947

416515.3

... More
Extra for Half Brick work masonry in superstructure above plinth level upto floor V level

439.71

159

70199.7

... More
Centering and shuttering including strutting, propping etc. And removal of form work for. Foundation, footing, bases of columns etc. For mass concrete.

306.45

286

87751.96

... More
Steel work welded in built up sections/framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

600

181

108960

... More
15mm thick Cement plaster or rough side of single or half brick wall of mix : 1:4 ( 1 cement : 4 coarse sand)

1131.63

327

371004.9

... More
Finishing walls with water proofing cement paint of required shade on new work (two or more coats) applied @ 3.84 Kg/10 Sqm

1131.63

98

111748.46

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work

52.32

131

6898.39

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

24.81

180

4479.45

... More
.Carriage of Sand , Stone agg. by Mechanical Transport from source to site of work including cost for loading and unloading.for an av. distance of 50Km & 500 mtrs by H.L

138.51

1335

184913.62

... More
Carriage of cement by Mechanical Transport from nearest market (to be identified by engineer in charge) to road side of work including cost for loading and unloading.for an av. distance of 05Km & 500 mtrs H.L

31.35

448

14047.94

... More
Carriage of Brick from brich klin (to be identified by engineer in charge) by Mechanical Transport to site of work including cost for loading and unloading.for an av. distance of 100Km & 500 mtrs H.L

34.11

4556

155410.96

... More
Chlorinator and Flow Meter SITC of Liquid Chlorinator dosing pump along with allied work. and supply of Hypochlorite solution in drums of suitable capacities for 12 months requirement (L.S)chlorine solution I.e. sodium hypochlorite solution in pipe line of tube well. This shall include metering pump & motor, solution storage tank, ejector, sample cock and PVCpipe line etc.

1

30000

30000

... More
SITC of Liquid Chlorinator dosing pump along with allied work. and supply of Hypochlorite solution in drums of suitable capacities for 12 months requirement (L.S)Supply of Hypochlorite solution in drums of suitable capacities for 12 months requirement.

1

160000

160000

... More
Providing and fixing Bulk Flow Meterscomplete with allied work. 150 mm dia

3

130000

390000

... More
Providing and fixing Bulk Flow Meterscomplete with allied work. 100 mm dia

6

100000

600000

... More
Providing and fixing Bulk Flow Meterscomplete with allied work. 80 mm dia

3

75000

225000

... More
Drilling of Tube Well Clearing of site by way of bush cutting , marking approach road, shifting of machinery and allied material, preparation of site, proper leveling for installation of machinery

1

65000

65000

... More
Drilling of gravel packed bore hole of 530 mm diameter for lowering of liner assembly consisting of blind and strainer pipes of 250 mm dia mts in all types of strata by drilling to suite requirements and conditions. The work excludes cost of blind pipe and strainer pipe upto the depth of 300 mtrs. a) From GL. to 300 meters below BGL

300

17600

5280000

... More
Providing and lowering of liner assembly 250 mm dia. After welding upto the desired length and design approved by the competent authority / Electric Logging

270

6000

1620000

... More
Providing and lowering of liner assembly 250 mm dia. Slotted. After welding upto the desired length and design approved by the competent authority.

30

9000

270000

... More
Providing of PEA shaped gravel as per IS-4097 of 1967 with latest amendments for gravel packing of tube well and shrouding during drilling and stabilization of tube well.

70

4500

315000

... More
Development of bore hole by air compressor of adequate capacity to give clear potable water free of sand and impurities. Stabilization and testing of bore well by way of V.T/submersible pumpset as per IS code- part-1 2800 of 1991 & IS- 2800 part-II of 1979 reaffirmed with up to date amendments pump set till the clear potable water having discharge as per specifications is yielded. Fabrication, providing/ fitting of steel supporting structure for clamping of Tube Well housing using 2 Nos. parallel ISMB-250 of 5 M length each and MS Angle 40X40X6mm and MS Plate 10 mm thick with 2 Nos. cement concrete blocks of size 1.00 M X1.00 MX 1.00 MI No. each of both ends,

1

550000

550000

... More
Electromechnical Components Providing, fitting, installation, testing and commissioning of H C Pump set unit as per IS 1520 under w.s.s. Basholi Town Specification:- Pump:- 1. Type :- Horizontal( split casing /Multi stage) 2. Discharge :- 8000GPH 3. Totat dynamic head :- 170 -190 4. Impeller:- Bronze 5. Pump casing:- Cast Iron 6. . Efficency:- Not less than 45 % 7. speed :- 2800-3000 rpm The pump shall confirm to IS-1520 code MOTOR :- A) Type :- Horizontal squirrel cage Induction Type B) Rating: - Suitable for above parameters. C) No of phases: 03 phase, 415 ±10% V D) Winding:-Copper wound squirrel cage E) Method of cooling: - Air cooled with fan mounted. F)Method of Starting: star delta The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator. Job includes Laying of foundation block for HCP of size 1.83 m (length) X 0.91 m (breadth) X 0.91 m (Depth) or as per site requirement. Disposing off the excavated material to a suitable place. Construction of foundation block by Providing and Fabricating a 10mm Tor steel bar mesh and placing the base frame on the mesh placed inside the shuttering after proper levelling. Fabrication of 06 nos. new Foundation bolts for the each HCP. These foundation bolts are to be fixing in the base frame and welding/fixing it with Tor steel mesh at appropriate places. Laying the block in 1:2:4 reinforced cement concrete mixture. Complete job involves skilled and semiskilled labour, cost of material and carriage charges of sand, bajree, 10mm dia. tor steel, Cement and allied materials along with hire charges of tools and tackles involved. The job also involves curing of laid block for 7 days. Fabrication of suction line for HCPs using 80mm/100 mm dia. “B” Class G.I/M.S pipes as per requirement. Providing and fitting of 80 mm/100 mm dia., 12 mm thick, M.S flanges to the ends of the GI/MS Pipes by way of welding as per requirement. Providing and fitting of 80 mm/100 mm dia. M.S Bends (both long and short) welded with M.S flanges or end of the GI/MS pipe as per requirement. The alignment of the suction lines must be perfect. Fabrication of common suction manifold out of 150 mm dia. MS pipe. The Suction lines are also to be welded with the suction manifold and the suction pipe attached with the Sump tank is to be interconnected to the manifold by way of P/F of 100mm/150 mm dia. sluice valves PN1.6 of reputed ISI make as per site requirement. Fabrication of delivery line for HCPs using 80mm/100 mm dia. “B” Class G.I/M.S pipes as per requirement. Providing and fitting of 80 mm/100 mm dia.12 mm thick, M.S flanges to the ends of the GI/MS Pipes by way of welding as per requirement. Providing and fitting of 80 mm/100 mm dia. M.S Bends (both long and short) welded with M.S flanges or end of the GI/MS pipe as per requirement. P/F of 01 No. 80 mm/100 mm dia. sluice valve and 1 no 80mm/100mmdia NRV PN1.6 on the delivery line by way of placing rubber gaskets in between flanges and the Valve and tightening them with the nuts and bolts. All the nuts, bolts and rubber gaskets are to be provided by the firm as per requirement. The alignment of the delivery lines must be perfect. Fabrication of common delivery manifold out of 150 mm dia. MS pipe. The delivery manifold shall be made vibration free by placing anchor blocks/supports at suitable places. The delivery lines are also to be welded with the delivery manifold and manifold is interconnected to the rising main by way of P/F of 01 No. 100 mm/150 mm dia., sluice valve and 01 no 100 mm/150 mm NRV on delivery manifold as per site requirement by way of placing rubber gaskets in between flanges and the Valve and tightening them with the nuts and bolts. The Welding must be of superior quality and the welding rods used must be confirming to ISI Standards. Workmanship must be of the highest quality. The Job also includes the painting of all the pipes and fittings with superior quality paint in two coats and Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I/MS B-class pipe with M.S Flanges fastened with weld joints on three ends (As per site requirement). The complete Job includes the cost of material, such as GI/MS Pipes, sluice and Non return Valve, Nuts and Bolts, Gaskets, paint, welding material, other tools and tackles, technical & non-technical labour, transportation and other miscellaneous charges. Note: Providing of third party inspection certificate of RITES/CEIL & Characteristic Curve of pumping equipment is compulsory and is to be approved from the concerned Engineer in incharge before installing. The Parameters of various HC Pump set to be installed are as below:

2

875000

1750000

... More
Providing, fitting, installation, testing and commissioning of H C Pump set unit as per IS 1520 under w.s.s. Basholi Town Specification:- Pump:- 1. Type :- Horizontal( split casing /Multi stage) 2. Discharge :- 8000GPH 3. Totat dynamic head :- 220-250 4. Impeller:- Bronze 5. Pump casing:- Cast Iron 6. . Efficency:- Not less than 45 % 7. speed :- 2800-3000 rpm The pump shall confirm to IS-1520 code MOTOR :- A) Type :- Horizontal squirrel cage Induction Type B) Rating: - Suitable for above parameters. C) No of phases: 03 phase, 415 ±10% V D) Winding:-Copper wound squirrel cage E) Method of cooling: - Air cooled with fan mounted. F)Method of Starting: star delta The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator. Job includes Laying of foundation block for HCP of size 1.83 m (length) X 0.91 m (breadth) X 0.91 m (Depth) or as per site requirement. Disposing off the excavated material to a suitable place. Construction of foundation block by Providing and Fabricating a 10mm Tor steel bar mesh and placing the base frame on the mesh placed inside the shuttering after proper levelling. Fabrication of 06 nos. new Foundation bolts for the each HCP. These foundation bolts are to be fixing in the base frame and welding/fixing it with Tor steel mesh at appropriate places. Laying the block in 1:2:4 reinforced cement concrete mixture. Complete job involves skilled and semiskilled labour, cost of material and carriage charges of sand, bajree, 10mm dia. tor steel, Cement and allied materials along with hire charges of tools and tackles involved. The job also involves curing of laid block for 7 days. Fabrication of suction line for HCPs using 80mm/100 mm dia. “B” Class G.I/M.S pipes as per requirement. Providing and fitting of 80 mm/100 mm dia., 12 mm thick, M.S flanges to the ends of the GI/MS Pipes by way of welding as per requirement. Providing and fitting of 80 mm/100 mm dia. M.S Bends (both long and short) welded with M.S flanges or end of the GI/MS pipe as per requirement. The alignment of the suction lines must be perfect. Fabrication of common suction manifold out of 150 mm dia. MS pipe. The Suction lines are also to be welded with the suction manifold and the suction pipe attached with the Sump tank is to be interconnected to the manifold by way of P/F of 100mm/150 mm dia. sluice valves PN1.6 of reputed ISI make as per site requirement. Fabrication of delivery line for HCPs using 80mm/100 mm dia. “B” Class G.I/M.S pipes as per requirement. Providing and fitting of 80 mm/100 mm dia.12 mm thick, M.S flanges to the ends of the GI/MS Pipes by way of welding as per requirement. Providing and fitting of 80 mm/100 mm dia. M.S Bends (both long and short) welded with M.S flanges or end of the GI/MS pipe as per requirement. P/F of 01 No. 80 mm/100 mm dia. sluice valve and 1 no 80mm/100mmdia NRV PN1.6 on the delivery line by way of placing rubber gaskets in between flanges and the Valve and tightening them with the nuts and bolts. All the nuts, bolts and rubber gaskets are to be provided by the firm as per requirement. The alignment of the delivery lines must be perfect. Fabrication of common delivery manifold out of 150 mm dia. MS pipe. The delivery manifold shall be made vibration free by placing anchor blocks/supports at suitable places. The delivery lines are also to be welded with the delivery manifold and manifold is interconnected to the rising main by way of P/F of 01 No. 100 mm/150 mm dia., sluice valve and 01 no 100 mm/150 mm NRV on delivery manifold as per site requirement by way of placing rubber gaskets in between flanges and the Valve and tightening them with the nuts and bolts. The Welding must be of superior quality and the welding rods used must be confirming to ISI Standards. Workmanship must be of the highest quality. The Job also includes the painting of all the pipes and fittings with superior quality paint in two coats and Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I/MS B-class pipe with M.S Flanges fastened with weld joints on three ends (As per site requirement). The complete Job includes the cost of material, such as GI/MS Pipes, sluice and Non return Valve, Nuts and Bolts, Gaskets, paint, welding material, other tools and tackles, technical & non-technical labour, transportation and other miscellaneous charges. Note: Providing of third party inspection certificate of RITES/CEIL & Characteristic Curve of pumping equipment is compulsory and is to be approved from the concerned Engineer in incharge before installing. The Parameters of various HC Pump set to be installed are as below:

2

902800

1805600

... More
Providing, fitting, installation, testing and commissioning of H C Pump set unit as per IS 1520 under w.s.s. Basholi Town Specification:- Pump:- 1. Type :- Horizontal( split casing /Multi stage) 2. Discharge :- 6000GPH 3. Totat dynamic head :- 220-250 4. Impeller:- Bronze 5. Pump casing:- Cast Iron 6. . Efficency:- Not less than 45 % 7. speed :- 2800-3000 rpm The pump shall confirm to IS-1520 code MOTOR :- A) Type :- Horizontal squirrel cage Induction Type B) Rating: - Suitable for above parameters. C) No of phases: 03 phase, 415 ±10% V D) Winding:-Copper wound squirrel cage E) Method of cooling: - Air cooled with fan mounted. F)Method of Starting: star delta The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator. Job includes Laying of foundation block for HCP of size 1.83 m (length) X 0.91 m (breadth) X 0.91 m (Depth) or as per site requirement. Disposing off the excavated material to a suitable place. Construction of foundation block by Providing and Fabricating a 10mm Tor steel bar mesh and placing the base frame on the mesh placed inside the shuttering after proper levelling. Fabrication of 06 nos. new Foundation bolts for the each HCP. These foundation bolts are to be fixing in the base frame and welding/fixing it with Tor steel mesh at appropriate places. Laying the block in 1:2:4 reinforced cement concrete mixture. Complete job involves skilled and semiskilled labour, cost of material and carriage charges of sand, bajree, 10mm dia. tor steel, Cement and allied materials along with hire charges of tools and tackles involved. The job also involves curing of laid block for 7 days. Fabrication of suction line for HCPs using 80mm/100 mm dia. “B” Class G.I/M.S pipes as per requirement. Providing and fitting of 80 mm/100 mm dia., 12 mm thick, M.S flanges to the ends of the GI/MS Pipes by way of welding as per requirement. Providing and fitting of 80 mm/100 mm dia. M.S Bends (both long and short) welded with M.S flanges or end of the GI/MS pipe as per requirement. The alignment of the suction lines must be perfect. Fabrication of common suction manifold out of 150 mm dia. MS pipe. The Suction lines are also to be welded with the suction manifold and the suction pipe attached with the Sump tank is to be interconnected to the manifold by way of P/F of 100mm/150 mm dia. sluice valves PN1.6 of reputed ISI make as per site requirement. Fabrication of delivery line for HCPs using 80mm/100 mm dia. “B” Class G.I/M.S pipes as per requirement. Providing and fitting of 80 mm/100 mm dia.12 mm thick, M.S flanges to the ends of the GI/MS Pipes by way of welding as per requirement. Providing and fitting of 80 mm/100 mm dia. M.S Bends (both long and short) welded with M.S flanges or end of the GI/MS pipe as per requirement. P/F of 01 No. 80 mm/100 mm dia. sluice valve and 1 no 80mm/100mmdia NRV PN1.6 on the delivery line by way of placing rubber gaskets in between flanges and the Valve and tightening them with the nuts and bolts. All the nuts, bolts and rubber gaskets are to be provided by the firm as per requirement. The alignment of the delivery lines must be perfect. Fabrication of common delivery manifold out of 150 mm dia. MS pipe. The delivery manifold shall be made vibration free by placing anchor blocks/supports at suitable places. The delivery lines are also to be welded with the delivery manifold and manifold is interconnected to the rising main by way of P/F of 01 No. 100 mm/150 mm dia., sluice valve and 01 no 100 mm/150 mm NRV on delivery manifold as per site requirement by way of placing rubber gaskets in between flanges and the Valve and tightening them with the nuts and bolts. The Welding must be of superior quality and the welding rods used must be confirming to ISI Standards. Workmanship must be of the highest quality. The Job also includes the painting of all the pipes and fittings with superior quality paint in two coats and Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I/MS B-class pipe with M.S Flanges fastened with weld joints on three ends (As per site requirement). The complete Job includes the cost of material, such as GI/MS Pipes, sluice and Non return Valve, Nuts and Bolts, Gaskets, paint, welding material, other tools and tackles, technical & non-technical labour, transportation and other miscellaneous charges. Note: Providing of third party inspection certificate of RITES/CEIL & Characteristic Curve of pumping equipment is compulsory and is to be approved from the concerned Engineer in incharge before installing. The Parameters of various HC Pump set to be installed are as below:

2

780300

1560600

... More
Design, fabrication, installation, testing and commissioning of floating jetty of 7500 x 7500 mm and Walk way of size 2 mtrs wide and 30 mtrs long by way of unique combination of HDPE floating cubes and hot dipped galvanized steel powder coated human guard rails of I- channel, fabrication of 02 no. gantries for chain pulley attachment with 30m rope of 12 mm dia. anti skid flooring. The job also includes the fabrication and fitting of pump rooms using colour cocurated sheets and PU Panles of reputed make of size 12 ft x 10 ft x 10 ft having sloping roof along with the attached bathroom of size 4 ft x 6 ft. It also has the provision for 6 ft X 6 ft Pantery along with all allied fitting, such as Electrical fitting, tabs, and also has the provision for waste collection tank and sewerage Tank. The platform should be easy to dismantle and reassemble also having the arrangement for installation of 02 nos. submersible pump sets. The platform should have been designed in such a way that it should bear 02 times safety factors considering all sorts of weights viz-a-viz 02 nos. submersible pump sets, chain pulley block of 01 ton capacity, gantry along with 08 to 10 persons weight and other allied accessories. The job also includes providing, installation, testing and commissioning of 02 nos. 8000 GPH x (100-120 )m head submersible pump sets along with LT control Panels 02 nos. The job also inludes the Providing and fitting of 02 nos Raising main HDPE pipes of 04 inch dia fitted along the both side of the walkby as per the site requirement. The job also includes the provind of Suitable anchoring/Support as per site requirement to the floating structure (Note: Providing of third party inspection certificate of RITES/CEIL & Characteristic Curve of pumping equipment and Floating structure is compulsory and Drawing of the floating structure should to be approved from the concerned Executive Engineer before installing.)\

1

9450000

9450000

... More
Specification:- Pump:- 1. Type :- Horizontal( split casing /Multi stage) 2. Discharge :- As mentioned in parameters or as per site requirement 3. Totat dynamic head :- As mentioned in parameters or as per site requirement 4. Impeller:- Bronze 5. Pump casing:- Cast Iron 6. . Efficency:- Not less than 45 % 7. speed :- 2800-3000 rpm The pump shall confirm to IS-1520 code MOTOR :- A) Type :- Horizontal squirrel cage Induction Type B) Rating: - Suitable for above parameters. C) No of phases: 03 phase, 415 ±10% V D) Winding:-Copper wound squirrel cage E) Method of cooling: - Air cooled with fan mounted. F)Method of Starting: star delta The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator. Job includes Laying of foundation block for HCP of size 1.83 m (length) X 0.91 m (breadth) X 0.91 m (Depth) or as per site requirement. Disposing off the excavated material to a suitable place. Construction of foundation block by Providing and Fabricating a 10mm Tor steel bar mesh and placing the base frame on the mesh placed inside the shuttering after proper levelling. Fabrication of 06 nos. new Foundation bolts for the each HCP. These foundation bolts are to be fixing in the base frame and welding/fixing it with Tor steel mesh at appropriate places. Laying the block in 1:2:4 reinforced cement concrete mixture. Complete job involves skilled and semiskilled labour, cost of material and carriage charges of sand, bajree, 10mm dia. tor steel, Cement and allied materials along with hire charges of tools and tackles involved. The job also involves curing of laid block for 7 days.Fabrication of suction line for HCPs using 80mm/100 mm dia. “B” Class G.I/M.S pipes as per requirement. Providing and fitting of 80 mm/100 mm dia., 12 mm thick, M.S flanges to the ends of the GI/MS Pipes by way of welding as per requirement. Providing and fitting of 80 mm/100 mm dia. M.S Bends (both long and short) welded with M.S flanges or end of the GI/MS pipe as per requirement. The alignment of the suction lines must be perfect. Fabrication of common suction manifold out of 150 mm dia. MS pipe. The Suction lines are also to be welded with the suction manifold and the suction pipe attached with the Sump tank is to be interconnected to the manifold by way of P/F of 100mm/150 mm dia. sluice valves PN1.6 of reputed ISI make as per site requirement.Fabrication of delivery line for HCPs using 80mm/100 mm dia. “B” Class G.I/M.S pipes as per requirement. Providing and fitting of 80 mm/100 mm dia.12 mm thick, M.S flanges to the ends of the GI/MS Pipes by way of welding as per requirement. Providing and fitting of 80 mm/100 mm dia. M.S Bends (both long and short) welded with M.S flanges or end of the GI/MS pipe as per requirement. P/F of 01 No. 80 mm/100 mm dia. sluice valve and 1 no 80mm/100mmdia NRV PN1.6 on the delivery line by way of placing rubber gaskets in between flanges and the Valve and tightening them with the nuts and bolts. All the nuts, bolts and rubber gaskets are to be provided by the firm as per requirement. The alignment of the delivery lines must be perfect. Fabrication of common delivery manifold out of 150 mm dia. MS pipe. The delivery manifold shall be made vibration free by placing anchor blocks/supports at suitable places. The delivery lines are also to be welded with the delivery manifold and manifold is interconnected to the rising main by way of P/F of 01 No. 100 mm/150 mm dia., sluice valve and 01 no 100 mm/150 mm NRV on delivery manifold as per site requirement by way of placing rubber gaskets in between flanges and the Valve and tightening them with the nuts and bolts. The Welding must be of superior quality and the welding rods used must be confirming to ISI Standards. Workmanship must be of the highest quality. The Job also includes the painting of all the pipes and fittings with superior quality paint in two coats and Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I/MS B-class pipe with M.S Flanges fastened with weld joints on three ends (As per site requirement). The complete Job includes the cost of material, such as GI/MS Pipes, sluice and Non return Valve, Nuts and Bolts, Gaskets, paint, welding material, other tools and tackles, technical & non-technical labour, transportation and other miscellaneous charges. Note: Providing of third party inspection certificate of RITES/CEIL & Characteristic Curve of pumping equipment is compulsory and is to be approved from the concerned Engineer in incharge before installing. HCP 4000GPH x (130-150) Mtr Head at CPS

2

195500

391000

... More
Fabrication, providing, fitting and lowering of B Class column pipe conforming to IS: 1239 of length 10 Rft into the production well up to the desired depth; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange.80 mm dia

30

7300

219000

... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for the operation of above mentioned submersible Pumping Unit and length as per site requirement. The cable connections terminal shall be fitted with copper thimbles of required size. 16 sq. mm

300

1500

450000

... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for the operation of above mentioned submersible Pumping Unit and length as per site requirement. The cable connections terminal shall be fitted with copper thimbles of required size. 6 sq. mm

200

6500

1300000

... More
Design , supply , installation , testing and commissioning of automatic power factor correction panel for improvement of power factor as per details given below: input voltage = 380 ± 15 V Ambient temp. = 0 c̊ to 50 c̊ Available Power Factor = 0.7 - 0.8 Target power factor = 0.98 lagging Switching time delay On delay = 1 – 60 seconds 0ff delay = 1- 60 seconds Control type = Binary/ intelligent CT Ratio programming = To be provided Programming link = To be provided Auto Scroll = To be provided Manual operation = To be provided Display Parameters = PF (input/output), KW, Volt, Amps. Relay contacts = As per requirement Dimensions = Adequate Bezel / panel Cut out = Adequate System protection = IP 55 Enclosure = Modular CRG Sheet , powder coated MCCB Main protection = As per requirement MCCB (Individual Protection of capacitors) = As per requirement 3 No. Power factor correction panel for improvement of power factor Suitable for connected load uptoup to 100 HP

1

132250

132250

... More
Design , supply , installation , testing and commissioning of automatic power factor correction panel for improvement of power factor as per details given below: input voltage = 380 ± 15 V Ambient temp. = 0 c̊ to 50 c̊ Available Power Factor = 0.7 - 0.8 Target power factor = 0.98 lagging Switching time delay On delay = 1 – 60 seconds 0ff delay = 1- 60 seconds Control type = Binary/ intelligent CT Ratio programming = To be provided Programming link = To be provided Auto Scroll = To be provided Manual operation = To be provided Display Parameters = PF (input/output), KW, Volt, Amps. Relay contacts = As per requirement Dimensions = Adequate Bezel / panel Cut out = Adequate System protection = IP 55 Enclosure = Modular CRG Sheet , powder coated MCCB Main protection = As per requirement MCCB (Individual Protection of capacitors) = As per requirement 3 No. Power factor correction panel for improvement of power factor Suitable for connected load uptoup to 50 HP

2

92600

185200

... More
Earthing of the electromechanical equipments: 01 no earth for electrical equipments and 01 no earth for body earth of pumping machinery which includes digging of a pit in the earth which should not be less than 3m (10ft) from the ground level . A plate made up of GI with dimensions 60cm x 60cm x 3.18mm is buried vertical in the earth (earth pit) which should not be less than 3m (10ft) from the ground level. Put about 30 cm layer of powdered charcoal and lime mixture around the earth plate in alternate layers. Providing and fitting of 40 mm dia pipe of 2.5 m length and GI strip of 32mm X 05 mm along with nuts and bolts inside the pit. Providing and fitting of 25 mm dia slotted pipe for putting water inside the pit to maintain moisture. The job also includes the chamber made of brick masosanary with CI cover 45 cm x 45 cm. The job includes the cost of material, labour, transport charges and any other miscellaneous charges.(Note: The distance between the two earth should not be less than 06 mtrs).

3

40000

120000

... More
Providing and Fitting of 3.5-Core, XLPE, Armored Aluminium Cable of suitable size and length conforming to IS: 7098 part 1st as service line from the HT transformer to voltage stabilizer including necessary thimbling, crimping, taping etc. 95 Sqm

60

1400

84000

... More
Providing and Fitting of 3.5-Core, XLPE, Armored Aluminium Cable of suitable size and length conforming to IS: 7098 part 1st as service line from the HT transformer to voltage stabilizer including necessary thimbling, crimping, taping etc. 120 Sqm

30

1800

54000

... More
Fabrication of the 01 nos board made out of angle iron and having a size of 06ft X 04 ft. The angle iron is to be welded at corners properly and flushed in all directions including its grinding or foiling to avoid body scratches. The panel board is to be surmounted with a ply of 06ft X 04 ft X 12mm thickness. The board shall have two legs at the corners and two legs are to be welded/grouted with the wall of the pump room. The job also includes the p/f of 01 no 415 volt, HRC fuse type main switch and 01 no Bus Bar, 03 no RYB phase indicator, voltmeter and ampere meter along with CT on board of reputed make conforming to IS standard of required specification for below mentioned connected load. The job also includes the P/F of cables of required size and length as per site for the connection of power supply of reputed make and conforming to IS standards with proper thimbling. The job includes the cost of material, fixation, transport and labour charges. up to 100 H P LOAD

1

90000

90000

... More
Fabrication of the 01 nos board made out of angle iron and having a size of 06ft X 04 ft. The angle iron is to be welded at corners properly and flushed in all directions including its grinding or foiling to avoid body scratches. The panel board is to be surmounted with a ply of 06ft X 04 ft X 12mm thickness. The board shall have two legs at the corners and two legs are to be welded/grouted with the wall of the pump room. The job also includes the p/f of 01 no 415 volt, HRC fuse type main switch and 01 no Bus Bar, 03 no RYB phase indicator, voltmeter and ampere meter along with CT on board of reputed make conforming to IS standard of required specification for below mentioned connected load. The job also includes the P/F of cables of required size and length as per site for the connection of power supply of reputed make and conforming to IS standards with proper thimbling. The job includes the cost of material, fixation, transport and labour charges. up to 50 H P LOAD

2

78000

156000

... More
Providing, Installation and testing commissioning of motorized chain hoist as per site requirement with hook suspension having following features and characteristics:- Make - Reputed make Capacity - As mentioned below in or as per requirement Hoisting speed - 2.4 M/Min Hoist motor H.P - as per requirement Min. Height of lift - 6 M Motor: The basic drive of the hoist be provided with 3 phase squired cage totally enclosed induction motor having a high starting torque with class “F” insulation. The make of the motor be NGEF / SEIMNS / GEC/ Crompton and conform to IS : 325 (RPM-1500) Brake: The hoist shall have instant action, Fail to safe electromagnetic disc brake mounted on the end of the motor to ensure minimum safety and reliability when the load is held in its position as soon as the supply to the motor is switched off internally or accidentally. The adjustment & maintenance of break shall be quick and simple. Gears: The hoist shall have precision cut super and helical gears made of alloy steel mounted on bearings and housed in a dust proof gear box. The lubrication of gears is of high viscosity and temperature for longer life of gears. Load Chain: The load chain is made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel: Specially designed, perfectly machined wheel providing correct grip of load chain made of malleable cast iron makes the hoist most safe and reliable against any failure. Lifting Hook: The lifting hook shall be forged with provision for free swivelling. Limit Switch: The limit switch shall have snap action, shunt type prevent over hoisting or over lowering to ensure maximum safety of operation. Control: The unit shall be controlled by heavy duty air break direction reversing type contractors and electrically inter – locked for safety. Contactors relay, fuses, low voltage transformer be fitted for control voltage and are to be housed in fabricated / pressed sheet steel box dust proof. Push button pendent: The contactors shall be operated by a pendent push button station suspended from hoist by a rope / dog chain to prevent any damage to the pendent cable and for easy operation. Test: The hoist supplied is to be tested at 25% overload and the test certificate of the same be provided at the time of installation. The complete unit as specified above is required to be fitted / tested at site. Besides the above works the job Includes Providing and fitting 3-Core 6 sq. mm ,50 m submersible cable for providing power supply to motor of chain Hoist including P/F protection device of suitable capacity.The capacity of motorized chain hoist to be installed are mentioned below: (5.00 M.T Capacity)

1

460000

460000

... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 3M long. The rubber mats shall be accepted with manufacturers test certificate.

3

9000

27000

... More
Design, fabrication, installation, testing and commissioning of LT control panel for the operation of H.C. induction Motor and Submersible motor of below mentioned pumping machinery. The LT panel shall be dust and vermin proof fabricated out of 14/16 SWG CR sheet supported on MS angle of Suitable size and provision for fixing it on the ground with the help of foundation Bolts/ wall Mounted as per site requirement. The panels should be sturdy enough for vibration free operation and should be equipped with suitable locking/ sealing arrangement for each box. The structure should be provided with the suitable entry and exit holes for incoming and outgoing cables. The Panel should be given two coats of anti-rust primer and two coats of enamel paint for smooth and even finish. Incoming Feeder: The incoming feeder for the operation induction/submersible motor must be equipped with a suitable capacity MCCB of Suitable breaking capacity. There must be Al./copper bus bars for all the three phases from the outgoing of the MCCB to all the three contactor. The panel must be fitted with 01 No. Volt 0-500 and 01 no ampere meter of suitable range with proper CT ratio showing voltage and current of all the three phases and RYB phase indicator lamps. Outgoing Feeders: The outgoing feeders for the operation of induction motor/submersible motor must be fitted with following items: 1 Aiir break contactors. of suitable rating for each motor of reputed make conforming to IS code. as per site requirement. 1.Star-Delta timer for each motor 2. Motor Protection relays having all the features such as Overload, short circuit, under current, phase unbalance, Phase sequence, Phase Loss, Earth fault, Dry running, Prolonged Starting/ Stalled rotor. The relay is be fitted on the door and it must be accessible by keeping the door of the panel closed.for each 3.Single Phase preventer.for each 4.02 No. indicator lamps for ON and TRIP indication.for each 5.02 No. Push Buttons for ON/OFF.for each 6.10 amp MCBs for protection of the control wiring. 7. Auto start with on delay timer.for each 8. Level controler sensor for auto ON/OFF of motors as per site requirement. 8.Volt meter and Ampere meter for each with proper CT ratio The cabling of the Control panel must be done with the suitable rating multi strand copper cable to withstand the full load of running motors. The internal control wiring should be done with flexible PVC LT cable with proper thimbling at each end. The job also includes the P/F of cables of required size and lenght as per site for the connection of power supply to LT panel of reputed make and conforming to IS standards. The capacity of various LT panel to be installed are mentioned below or as per site requirements. (Note: Panel should be of outdoor type conforming to all standard as per IS code, if Panel have to install out side the pump room and Level controler will be install where Sump/ OHT are with in satation or as per site requirement.) up to 60 HP

2

222640

445280

... More
Design, fabrication, installation, testing and commissioning of LT control panel for the operation of H.C. induction Motor and Submersible motor of below mentioned pumping machinery. The LT panel shall be dust and vermin proof fabricated out of 14/16 SWG CR sheet supported on MS angle of Suitable size and provision for fixing it on the ground with the help of foundation Bolts/ wall Mounted as per site requirement. The panels should be sturdy enough for vibration free operation and should be equipped with suitable locking/ sealing arrangement for each box. The structure should be provided with the suitable entry and exit holes for incoming and outgoing cables. The Panel should be given two coats of anti-rust primer and two coats of enamel paint for smooth and even finish. Incoming Feeder: The incoming feeder for the operation induction/submersible motor must be equipped with a suitable capacity MCCB of Suitable breaking capacity. There must be Al./copper bus bars for all the three phases from the outgoing of the MCCB to all the three contactor. The panel must be fitted with 01 No. Volt 0-500 and 01 no ampere meter of suitable range with proper CT ratio showing voltage and current of all the three phases and RYB phase indicator lamps. Outgoing Feeders: The outgoing feeders for the operation of induction motor/submersible motor must be fitted with following items: 1 Aiir break contactors. of suitable rating for each motor of reputed make conforming to IS code. as per site requirement. 1.Star-Delta timer for each motor 2. Motor Protection relays having all the features such as Overload, short circuit, under current, phase unbalance, Phase sequence, Phase Loss, Earth fault, Dry running, Prolonged Starting/ Stalled rotor. The relay is be fitted on the door and it must be accessible by keeping the door of the panel closed.for each 3.Single Phase preventer.for each 4.02 No. indicator lamps for ON and TRIP indication.for each 5.02 No. Push Buttons for ON/OFF.for each 6.10 amp MCBs for protection of the control wiring. 7. Auto start with on delay timer.for each 8. Level controler sensor for auto ON/OFF of motors as per site requirement. 8.Volt meter and Ampere meter for each with proper CT ratio The cabling of the Control panel must be done with the suitable rating multi strand copper cable to withstand the full load of running motors. The internal control wiring should be done with flexible PVC LT cable with proper thimbling at each end. The job also includes the P/F of cables of required size and lenght as per site for the connection of power supply to LT panel of reputed make and conforming to IS standards. The capacity of various LT panel to be installed are mentioned below or as per site requirements. (Note: Panel should be of outdoor type conforming to all standard as per IS code, if Panel have to install out side the pump room and Level controler will be install where Sump/ OHT are with in satation or as per site requirement.) up to80 HP

2

278300

556600

... More
Design, fabrication, installation, testing and commissioning of LT control panel for the operation of H.C. induction Motor and Submersible motor of below mentioned pumping machinery. The LT panel shall be dust and vermin proof fabricated out of 14/16 SWG CR sheet supported on MS angle of Suitable size and provision for fixing it on the ground with the help of foundation Bolts/ wall Mounted as per site requirement. The panels should be sturdy enough for vibration free operation and should be equipped with suitable locking/ sealing arrangement for each box. The structure should be provided with the suitable entry and exit holes for incoming and outgoing cables. The Panel should be given two coats of anti-rust primer and two coats of enamel paint for smooth and even finish. Incoming Feeder: The incoming feeder for the operation induction/submersible motor must be equipped with a suitable capacity MCCB of Suitable breaking capacity. There must be Al./copper bus bars for all the three phases from the outgoing of the MCCB to all the three contactor. The panel must be fitted with 01 No. Volt 0-500 and 01 no ampere meter of suitable range with proper CT ratio showing voltage and current of all the three phases and RYB phase indicator lamps. Outgoing Feeders: The outgoing feeders for the operation of induction motor/submersible motor must be fitted with following items: 1 Aiir break contactors. of suitable rating for each motor of reputed make conforming to IS code. as per site requirement. 1.Star-Delta timer for each motor 2. Motor Protection relays having all the features such as Overload, short circuit, under current, phase unbalance, Phase sequence, Phase Loss, Earth fault, Dry running, Prolonged Starting/ Stalled rotor. The relay is be fitted on the door and it must be accessible by keeping the door of the panel closed.for each 3.Single Phase preventer.for each 4.02 No. indicator lamps for ON and TRIP indication.for each 5.02 No. Push Buttons for ON/OFF.for each 6.10 amp MCBs for protection of the control wiring. 7. Auto start with on delay timer.for each 8. Level controler sensor for auto ON/OFF of motors as per site requirement. 8.Volt meter and Ampere meter for each with proper CT ratio The cabling of the Control panel must be done with the suitable rating multi strand copper cable to withstand the full load of running motors. The internal control wiring should be done with flexible PVC LT cable with proper thimbling at each end. The job also includes the P/F of cables of required size and lenght as per site for the connection of power supply to LT panel of reputed make and conforming to IS standards. The capacity of various LT panel to be installed are mentioned below or as per site requirements. (Note: Panel should be of outdoor type conforming to all standard as per IS code, if Panel have to install out side the pump room and Level controler will be install where Sump/ OHT are with in satation or as per site requirement.) up to 25 HP

2

125200

250400

... More
Fabrication of gantry mechanism by way of fabrication and erection of M.S./ G.I. Pipe Gantry for extrection and lowering of submersible pump set along with column pipe. The job includes fabrication of 02 nos vertical members of M.S/ G.I Pipe 6" dia medium class each of height 15 ft. embedded in cement concrete block of 3'x3'x3' from bottom of the vertical column pipe 02 nos. It includes earth work for excavation of foundation of size 3'x3'x3' of cement concrete block for embedding of foot of vertical column. cast of cement concrete block in 1:2:4 mix of size 3'x3'x4'(1'AGL). Providing and embedding of 04 nos foundation blots of size 2'x16mm in eachblock. the job also includes providing and fitting of 02 nos MS plates 8 mm thick of size 2'x2' welding of 04 nos ribs at base of the column pipes and 02 nos MS plates 8 mm thick of size 1'x1' at the top of column pipes, welding of 04 nos ribs at the base of the vertical column pipes for strengthening of vertical column pipe, placing/welding of horizontal 4"dia-8ft pipe above the column vertical pipes. the job also includes providing and welding of main cross member made out of 4" dia M.S/G.I pipe-1.5 mtrs medium class on top. Making og one number MS steel ladder on side of vertical pipe fabricated out of MS angles (1.5' Length) of suitable size and shall be welded properly at an equidistant of 1 ft each from bottom to top of MS Column pipe. The job includes painting of pupes by way of making surface smooth emert paper and initially giving one coat of red oxide and finally two coats of black enamel paint for smooth finish.

1

125000

125000

... More
Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipment to be installed at site of appropriate size as per site requirement.

3

10000

30000

... More
Fabrication of 2’ x 6’ angle iron bench by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded

3

5500

16500

... More
Providing, fitting, testing and commissioning of voltage stabilizer as per below specifications: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Change over Switch: : Qty. : 1No. Make : reputed make Rating : Suitable capicity Type :Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz. Input voltage :250-460 volts.(3 phase) Output voltage :400 ±10% volts. Frequency :50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fibre glass insulations to tested parameters. Cooling :Naturally, Oil cooled Temp. Rise (Max):30°C above ambient Mounting :On Uni-directional wheels. Correction rate :30 volts per step Wave form distortion :virtually nil Duty cycle :100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. The job also include P/F of Copper cable of reputed make conforming to IS code and suitable capacity of required length as per site requirement for connection of power supply to voltage stabilizer. 150KVA

1

448500

448500

... More
Providing, fitting, testing and commissioning of voltage stabilizer as per below specifications: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Change over Switch: : Qty. : 1No. Make : reputed make Rating : Suitable capicity Type :Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz. Input voltage :250-460 volts.(3 phase) Output voltage :400 ±10% volts. Frequency :50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fibre glass insulations to tested parameters. Cooling :Naturally, Oil cooled Temp. Rise (Max):30°C above ambient Mounting :On Uni-directional wheels. Correction rate :30 volts per step Wave form distortion :virtually nil Duty cycle :100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. The job also include P/F of Copper cable of reputed make conforming to IS code and suitable capacity of required length as per site requirement for connection of power supply to voltage stabilizer. 100KVA

1

385250

385250

... More
Providing, fitting, testing and commissioning of voltage stabilizer as per below specifications: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Change over Switch: : Qty. : 1No. Make : reputed make Rating : Suitable capicity Type :Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz. Input voltage :250-460 volts.(3 phase) Output voltage :400 ±10% volts. Frequency :50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fibre glass insulations to tested parameters. Cooling :Naturally, Oil cooled Temp. Rise (Max):30°C above ambient Mounting :On Uni-directional wheels. Correction rate :30 volts per step Wave form distortion :virtually nil Duty cycle :100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. The job also include P/F of Copper cable of reputed make conforming to IS code and suitable capacity of required length as per site requirement for connection of power supply to voltage stabilizer. 100KVA

1

281800

281800

... More
Providing & fitting fixing with pvc insulated single core multistrand copper cable of size mentioned below conforming to IS: 694 for inter connection with all electrical equipments. 50 Sq mm

120

1500

180000

... More
Operation and Maintenace Cost of scheme for 5 years (after completion of Defect Liability period) complete in all repects by operation and maintaining all the instruments during warranty period and maintenance period for 5 years with replacement/repair of all damaged or non functioning units /Components incl accessories.

-

-

-

... More
Ist YEAR

1

1184952

1184952

... More
2nd YEAR

1

1777428

1777428

... More
3rd YEAR

1

2369904

2369904

... More
4th YEAR

1

2962380

2962380

... More
5th YEAR

1

3554856

3554856



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.