Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date18 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 5,22,60,000 
Notes
Download

Costs

Summary

Providing Water Supply Facilities For The Coverage Of Fhtc Including Pipe Laying From Water Lifting Station To Pst Pampore, Providing Laying And Fitting Of Distribution Mains Construction Of Pre Settling Tank 2mgd Construction Of Additional Filte

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: all kind of soil.1 meter from cutting edge

1

479

479.3

... More
25 meter beyond 1 m from cutting edge

1

576

576.45

... More
50 meter beyond 1 m from cutting edge

1

673

673.3

... More
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kind of soil.

1

256

256.85

... More
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. 2.27.1 Beyond 30 cm girth upto and including 60 cm girth.

1

379

379.05

... More
Beyond 30 cm girth upto and including 60 cm girth.

1

379

379.05

... More
Beyond 60 cm girth upto and including 120 cm girth.

1

1683

1683

... More
Beyond 120 cm girth upto and including 240 cm girth.

1

7795

7795.7

... More
Above 240 cm girth

1

15627

15627.5

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

1

12

12.49

... More
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.

1

167

167.8

... More
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 2.14.2 Depth exceeding 1.5 m but not exceeding 3 m

1

255

255.2

... More
Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete mix, diameter and length below the pile cap,to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) 21.2.1 By percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete.450 mm dia. piles. M-25

1

1941

1941.9

... More
M-30

1

1957

1957.55

... More
M-35

1

1973

1973.3

... More
500 mm dia piles M-25

1

2275

2275.5

... More
M-30

1

2294

2294.8

... More
M-35

1

2314

2314.25

... More
600 mm dia piles M-25

1

3095

3095.25

... More
M-30

1

3123

3123.1

... More
M-35

1

3151

3151.1

... More
750 mm dia piles M-25

1

4693

4693.95

... More
M-30

1

4737

4737.4

... More
M-35

1

4781

4781.1

... More
Vertical load testing of piles in accordance with IS 2911 (PartIV) including installation of loading platform by Kentledge/Anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer-in-Charge. 21.6.1 Single pile upto 50 tonne safe capacity.Initial test (Test Load 2.5 times the safe capacity)

1

159533

159533

... More
Routine test (Test Load 1.5 times the safe capacity)

1

175486

175486.6

... More
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. (Chipping of Pile Heads)

1

2516

2516.85

... More
Providing and laying hand packed stone soling (Quarry) 75mm nominal size including ramming and dressing including all leads lifts and all carriages complete.

1

1320

1320

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

1

6540

6540.45

... More
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)

1

5673

5673.4

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

1

5202

5202.9

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

7788

7788.4

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement .1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).

1

9395

9395.7

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with:1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9821

9821.85

... More
Providing and laying upto floor v level reinforced cement concrete in kerbs, steps and the like including curing but excluding the cost of centering, shuttering, finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9023

9023.35

... More
Reinforced cement concrete work in arches, arch ribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size

1

10377

10377.15

... More
Reinforced cement concrete work in chimneys, shafts upto floor five level including curing complete but excluding the cost of centering, shuttering, finishing and reinforcement with:1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).

1

9588

9588.05

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works upto plinth level

1

8021

8021.1

... More
All works above plinth level upto floor V level

1

9412

9412.05

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately. 5.35.1 Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

1

98

98.8

... More
Extra for R.C.C./B.M.C./R.M.C. work above floor V level for each four floors or part thereof.

1

280

280.95

... More
Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein.

1

941

941

... More
Supply and filling of filter media from approved source - Gravel (Graded gravel - size ranging from 2.0mm to 40.00 mm) in filter beds. Including all carriages, complete job

1

7700

7700

... More
Supply and filling of filter media from approved source - Sand (Coarse filter sand - in filter beds. Including all carriages, complete job

1

7968

7968

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.

1

286

286.35

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

1

573

573.85

... More
Suspended floors, roofs, landings, balconies and access platforms.

1

628

628.95

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers.

1

577

577.55

... More
Columns, pillars, piers, abutments, posts and struts.

1

742

742.55

... More
Stairs (excluding landings) except spiral staircases.

1

851

851.15

... More
Spiral staircases (including landings)

1

676

676.25

... More
Arches, domes, vaults upto 6 m span

1

2281

2281.2

... More
Extra for arches, domes, vaults exceeding 6 m span

1

1118

1118.85

... More
Chimney and shafts

1

573

573.85

... More
Extra for shuttering in circular work (20% of respective centering and Shuttering items)

1

-

0.2

... More
Edges of slabs and breaks in floors and walls

1

286

286.35

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (plan area to be measured)

1

293

293.9

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement)

1

63

63

... More
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

1

330

330.95

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars of grade Fe-500D or more.

1

123

123.2

... More
CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 12mm Cement plaster finished with a floating coat of neat cement of mix:1 : 3 ( 1 cement : 3 fine sand)

1

370

370.75

... More
1 : 4 ( 1 cement : 4 fine sand)

1

353

353.1

... More
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)

1

241

241.25

... More
Extra for plastering exterior walls of the height more than 10m from ground level for every additional height of 3m or part thereof.

1

65

65.05

... More
Extra for plastering Spherical Ceiling

1

141

141

... More
Groined ceiling

1

153

153

... More
Flewing Soffits

1

93

93

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

1

218

218.4

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6mm for diagonal braces.

1

5493

5493.9

... More
Using flats 30x6mm for diagonal braces and central cross piece.

1

5338

5338.5

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. chequered plate wherever required, all complete.In stringers, treads, landings etc. of stair cases, including use of

1

141

141.4

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

1

181

181.6

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S tube.

1

161

161.05

... More
E.R.W. tubes

1

154

154.7

... More
G.I. pipes

1

197

197.45

... More
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore.

1

109

109.65

... More
Above 40 mm nominal bore

1

121

121.65

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc complete : 50mm to 150mm nominal bore

1

1387

1387.5

... More
15mm to 40mm nominal bore

1

730

730.25

... More
Providing and laying M.S. Black pipes P/E confirming to IS :1239 part -1{2004]incld.welding. 150mm dia pipe

1

2142

2142.36

... More
M.S flanges

1

460

460.8

... More
M.S nuts and bolts

1

115

115.2

... More
Rubber gasket

1

100

100.8

... More
90 Degree Bend

1

288

288

... More
45 Degree Bend

1

648

648

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329 150 mm dia Ductile Iron Double Flanged

1

2295

2295.65

... More
Providing and laying D.I. Specials of Class K-12 suitable for mechanical jointing as per IS : 9523 Upto 600 mm dia.

1

17971

17971.65

... More
Providing and laying S&S Centrifugally Cast (Spun)/ Ductile Iron Pipes conforming to IS : 8329 150 mm dia Ductile Iron Class K - 7 Pipes

1

1934

1934.7

... More
300 mm dia Ductile Iron Class K - 7 Pipes

1

3141

3141.1

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately).150 mm dia. Class I

1

5968

5968.85

... More
300 mm dia. Class I

1

23159

23159.45

... More
Providing and laying D.I. Specials of Class K-12 suitable for push-on jointing as per IS : 9523 Upto 600 mm dia

1

17102

17102

... More
Providing and fixing G.I. pipes (B medium) complete with G.I. fittings excluding trenching and refilling etc. (external work). 15 mm dia. nominal bore

1

206

206.5

... More
20 mm dia. nominal bore

1

255

255.2

... More
25 mm dia. nominal bore

1

339

339.25

... More
32 mm dia. nominal bore

1

411

411.3

... More
40 mm dia. nominal bore

1

489

489.25

... More
50 mm dia. nominal bore

1

805

805.7

... More
65 mm dia. nominal bore

1

1018

1018.05

... More
80 mm dia. nominal bore

1

1151

1151.2

... More
100 mm dia. nominal bore

1

1434

1434

... More
150 mm dia. nominal bore

1

2256

2256.9

... More
Providing and fixing D.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Confirming to IS:14846 read with latest amendments.65mm dia class 1

1

6500

6500

... More
80mm dia class 1

1

11914

11914

... More
100 mm dia. Class 1

1

14594

14594

... More
125 mm dia. Class 1

1

17694

17694

... More
150 mm dia. Class 1

1

22439

22439

... More
200 mm dia. Class 1

1

35132

35132

... More
250 mm dia. Class 1

1

55820

55820

... More
300 mm dia. Class 1

1

68786

68786

... More
350 mm dia. Class 1

1

112570

112570

... More
Providing & fixing of MS fittings viz bends of suitable degree, tees, collars etc to be fabricated from 6mm Nominal Size MS plate as per the requirement of site including cost of welding. The work should be leakproof and should be painted with anti corrosive red oxide primer. Complete Job.

1

147

147.82

... More
Providing, fabricating & installation/laying of fittings for flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc. suitable for flanged jointing as per IS : 1538 (as per site requirement)Upto 300mm dia.

1

8539

8539.2

... More
Over 300 mm dia.

1

8806

8806.75

... More
Providing and fixing of MS flanged joints (12mm thick) to double flanged GI/DI pipes including cutting of pipes, welding charges, cutting of flanges, rubber gasket, bolts, nuts including testing of joint and sorts of carriages. Complete Job.50mm dia. pipe.

1

600

600

... More
65mm dia. pipe.

1

650

650

... More
80mm dia. pipe.

1

700

700

... More
100 mm dia. pipe

1

800

800

... More
125 mm dia. pipe

1

850

850

... More
150 mm dia. pipe

1

900

900

... More
200 mm dia. pipe

1

1200

1200

... More
250 mm dia. pipe

1

1500

1500

... More
300 mm dia. pipe

1

1800

1800

... More
350 mm dia. Pipe

1

2500

2500

... More
Providing & fixing ventilator of size 450mm x 450mm made out of angle iron 40mm x 40mm with wire mesh of 25mm x 25mm size including welding charges & inlcuding all carriages upto site of work.

1

1500

1500

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete. Serrated with central bulb (225 mm wide, 8-11mm thick)

1

283

283.25

... More
Dumb bell with central bulb (180mm wide, 8mm thick)

1

229

229.75

... More
Kickers (320mm wide, 5mm thick)

1

229

229.75

... More
Providing & fixing of 0.63mm thick PGI sheets at construction joints including all leads and lifts complete job as directed by Engineer-in-charge

1

800

800

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand)

1

7571

7571.55

... More
Cement mortar 1:6 ( 1 cement : 6 coarse sand)

1

6768

6768.05

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

1

1455

1455.65

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood.

1

108897

108897.35

... More
Pre-laminated particle board with decorative lamination on both sides,Grade I, Type II IS : 12823 marked

1

1748

1748.4

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. First class kail wood (30 mm thick shutter)

1

2892

2892.1

... More
First class kail wood (30 mm thick shutter)

1

2892

2892.1

... More
Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete.With Galvanized M.S. Wire gauge with wire of dia 0.63 mm

1

1308

1308.35

... More
With 2nd class teak wood beading 62x19 mm

1

827

827.4

... More
4 mm thick glass pane (weighing not less than 10 kg/sqm)

1

1985

1985.85

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters80x1.25 mm M.S. laths with 1.25 mm thick top cover

1

3305

3305

... More
Providing and fixing ball bearing for rolling shutters.

1

531

531.55

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.40mm thick with 20 mm nominal size stone aggregate.

1

510

510.25

... More
50 mm thick with 20mm nominal size stone aggregate.

1

562

562.15

... More
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including skirting in vertical & pointing the joints with white cement and matching pigment etc., completeIn colour such as White, Ivory, Grey, Fume, Red Brown (as dirrected by the engineer incharge)

1

1107

1107.65

... More
Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including skirting in vertical, rubbing, polishing and curing complete with:Makrana White Second quality (16mm)

1

3316

3316.05

... More
Extra for pre finished nosing to treads of steps of marble stone

1

553

553.7

... More
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 meter.

1

644

644.25

... More
Pointing on brick work in 1 cement : 3 sand mix. flush/ruled/structure or weathered pointing

1

200

200.8

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)

1

98

98.75

... More
Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)

1

64

64.6

... More
Applying priming coat:With ready mixed aluminum primer of approved brand and manufacture on resinous wood and ply wood

1

61

61.4

... More
Applying priming coat:With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works

1

53

53.6

... More
Applying priming coat:With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work (second coat)

1

28

28.85

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work

1

131

131.85

... More
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

1

194

194.65

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc completeOn steel work

1

197

197.8

... More
On concrete work

1

199

199.1

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade

1

127

127.95

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer.

1

164

164.6

... More
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc.complete 125 mm

1

68

68

... More
100 mm

1

60

60

... More
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm

1

83

83.8

... More
100x10 mm

1

63

63.35

... More
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2

1

852

852.5

... More
0.80 mm thick with zinc coating not less than 275 gram/m2

1

1158

1158.35

... More
0.63 mm thick with zinc coating not less than 275 gram/m2

1

974

974.05

... More
Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete0.80 mm thick with zinc coating not less than 275 gram/m2

1

840

840.15

... More
0.63 mm thick with zinc coating not less than 275 gram/m2

1

761

761.95

... More
0.50 mm thick with zinc coating not less than 275 gram/m2

1

690

690.85

... More
Providing and fixing plained eaves boarding. (II Class kail Wood)250x32 mm (nominal size )

1

702

702.55

... More
300x40 mm (nominal size)

1

1007

1007.5

... More
Providing and fixing of 0.5mm Color GS Sheet Soffit boarding including Backing, supports etc complete job

1

600

600

... More
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.1 mm thick

1

138

138.1

... More
2 mm thick

1

181

181.05

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete. Serrated with central bulb (225 mm wide, 8-11mm thick)

1

283

283.25

... More
Dumb bell with central bulb (180mm wide, 8mm thick)

1

229

229.75

... More
Kickers (320mm wide, 5mm thick)

1

229

229.75

... More
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage

1

554

554.1

... More
Providing & fixing of 0.63mm thick PGI sheets at construction joints including all leads and lifts complete job as directed by Engineer-in-charge

1

800

800

... More
Providing and fixing aluminum work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 andIS: 1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides withrequired EPDM rubber / neoprene gasket felt etc. Aluminum sectionsshall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading forglazing / panelling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-Charge (glazing,panelling and dash fasteners to be paid for separately.)For fixed portion. Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)

1

481

481.95

... More
Powder coated aluminum (minimum thickness of powder coated 50 microns)

1

514

514.3

... More
Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns)

1

522

522.7

... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)

1

574

574.45

... More
Powder coated aluminum (minimum thickness of powder coated 50 microns)

1

607

607.4

... More
Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns)

1

616

616

... More
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm)

1

1061

1061.95

... More
With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)

1

1201

1201.8

... More
With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm)

1

1584

1584.45

... More
Providing & fixing of PVC under drainage laterals with specifications conforming to IS-4985 & IS-15801, 8mm thick fabricated out of approved make with nominal dia of 9mm perforations as per design of bed provided at 60 degrees along with PVC Tees and end caps grouted in concrete, the pressure rating of 10kg/sq cm50 mm dia

1

530

530

... More
62.5 mm dia

1

1110

1110

... More
75 mm dia

1

1420

1420

... More
100 mm dia

1

1990

1990

... More
Dry Random Rubble stone masonry with hard stone(.Quarry) with bond stone

1

5536

5536.55

... More
Providing & Fixing WC Indian Type (0.45x 0.60)

1

2500

2500

... More
Providing & Fixing PVC Low Level Flushing tank of 10 Litre Capacity

1

1500

1500

... More
Providing and Fixing of Kitchen Sink

1

1500

1500

... More
Providing & Fixing of trap 100 dia

1

250

250

... More
Providing & Fixing 50mm PVC vent pipe

1

450

450

... More
Providing & Fixing of PVC specials

1

250

250

... More
Tee 100x100

1

250

250

... More
100 Bend

1

250

250

... More
100 mm PVC pipe (fenolex,prakash Suriya)

1

250

250

... More
80 mm PVC pipe (fenolex,prakash Suriya)

1

200

200

... More
Providing & Fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc 15 mm

1

300

300.4

... More
Providing and Fixing of Water storage tank including fittings

1

11

11.25

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge.Made of G.I. wire of dia 4 mm

1

809

809.9

... More
Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade

1

852

852.05

... More
Providing and fixing of aluminium haldaraz/ sliding door bolt ISI mark

1

292

292.8

... More
Providing and fixing brass bib cock of approved quality.15 mm nominal bore

1

334

334.7

... More
20 mm nominal bore

1

372

372.9

... More
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin/wall mixer and geyser points of approved make conforming to IS : 8931

1

582

582.35

... More
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.

1

2072

2072.1

... More
Electrification of Quarter including cost of wire 1.5mm /4mm ,gadjets, switches, bakelite board ,conduit, main board and MCB etc complete job as directed by Site EngineerLightening point

1

1600

1600

... More
Heating Points

1

2100

2100

... More
Providing and fitting of service line 7/16 of specified specification complete job

1

150

150

... More
Supply , Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm dia ceiling fan. 5 Star make CG/Havells /Usha

1

10000

10000

... More
Providing and Fixing of 0.5 HP water motor pump of approved quality as directed by Engineer-in-Charge.

1

3000

3000

... More
Providing and fixing of 65mm dia PVC under drainage system with specifications conforming to ISI 1592 of 1980 read up to date amendments of 10kg/cm standard quality.

1

350

350

... More
Supply and installation of PVC tees and end caps 65mm dia for under drainage system. Tees

1

145

145

... More
Supply and installation of PVC tees and end caps 65mm dia for under drainage system. End caps

1

100

100

... More
Providing, Installation of approved make Gyser of 50ltr capacity including CP nipples complete job

1

12500

12500

... More
Preparation of subgrade by excavating earth to an average of 22.5 cm depth, dressing to camber and consolidation with road roller of 8-12 tonne capacity including making good the undulation etc. and disposal of surplus earth upto 50 meters

1

153

153

... More
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.

1

768

768.15

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.

1

1885

1885.95

... More
Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface and cleaning with mechanical broom On W.B.M. /W.M.M. @ 0.4 Kg/sqm

1

31

31.6

... More
Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge.50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.5% (percentage by weight of total mix) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity

1

8734

8734.85

... More
Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface and cleaning with mechanical broom.On bituminous surface @ 0.25 Kg/sqm.

1

20

20.35

... More
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.25 mm compacted thickness with bitumen of grade VG- 30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity

1

298

298.5

... More
Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road all complete.

1

101

101.4

... More
Dismantling manually/ mechanically including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: Bituminous road.

1

305

305.95

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles above 25 mm and upto 40 mm.

1

89

89.95

... More
Supplying and stacking at site Graded crushed stone aggregate of size 90 mm to 45 mm

1

1204

1204.15

... More
63 mm to 45 mm

1

1204

1204.15

... More
53 mm to 22.4 mm

1

1204

1204.15

... More
13.2 mm nominal size (Type A)

1

1204

1204.15

... More
11.2 mm nominal size (Type B)

1

1204

1204.15

... More
Red bajri

1

1204

1204.15

... More
Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling (Payment for red bajri to be made separately):With road roller

1

11

11.1

... More
With hand roller

1

13

13.05

... More
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge

1

816

816.15

... More
Cutting bajri paths and making good the same including supply of extra quantities of brick aggregate, moorum and red bajri required.

1

204

204.5

... More
Providing fixing of Exuast fan 300 approved make

1

1500

1500

... More
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.

1

37

37.9

... More
supply of unskilled labours

1

625

625

... More
Engagement of welder along with welding set,gen set carraige upto site of work,for welding of damaged joints,reactivation/charging of existing system

1

3000

3000

... More
Providig and fixing hardware items to Doors and Windows Main Door (link locks)

1

1500

1500

... More
Butt hinges 100/75mm

1

84

84.65

... More
Providing fixing Gun Metal gate valve with CI wheel of approved quality (screwed end) 40 mm dia. nominal bore

1

834

834.6

... More
50 mm dia. nominal bore

1

986

986.15

... More
65 mm dia. nominal bore

1

1646

1646.05

... More
80 mm dia. nominal bore

1

2605

2605.15

... More
Hiring charges of Hydraulic excavator of 1 cum bucket inld haultage & transportation.

1

800

800

... More
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)

1

1725

1725.2

... More
1:4:8 or leaner mix (i/c equivalent design mix)

1

1064

1064.55

... More
Supplying and filling in plinth with GSB under floors including, watering rumming consolidating and dressing complete. INCLUDING CARRIAGE COMPLETE JOB

1

750

750

... More
P/F commissioning & sucessfull testing of twin lobe air blower (Everest make or Kay make) capable for providing compression @ 21.68 cum per minute @ 0.35 kG/Sqm with suitable 3 phase induction motor(30 HP) with auxilary pipe system up to filter beds filling pressure guage nozzels cement conc block base plate air check valves , non return valves, cement conc block in M-20 grade foundation bolts base frame fabricated out of 100mm MS channels, the job also includes PRV pipe and pipe fittings starters(MUG-50) and PVC 19/18 copper wire complete job and other electrical controlling devices fitted on pannel board. Complete job.

1

350000

350000

... More
Providinf laying 40mm dia PVC pipe and pipe fittings upto point of bleaching application in the clear water chamber and gate valves (B-class pipe) incld. complete job.

1

80

80

... More
Cutting road and making good the same including supply of extra quantities of material i.e. crushed aggregate, moorum screening, red bajri and labour required.Bituminous portion

1

4000

4000.4

... More
Water bound macadam.

1

2236

2236.2

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineerin-Charge)0.50mm+/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5 x55mm) with EPDM seal or with polymer coated J or L hooks,bolts and nuts 8mm diameter with bitumen and G.l. limpet washers or with G.l. limpet washers filled with white leadcomplete upto any pitch in horizontal /vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

1

704

704.15

... More
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.

1

1204

1204.5

... More
Operation and maintanance of the Scheme for 05 years which includes Techanical & non technical staff for running the filtration plant (Min: 06 N0.)including field staff ( 01 Fitter & 02 Helper for 15 Km disttribution & 01 Fitter 01 Helper for supplymains of 15 KMS)for checking & pluging of leakages Change of filter media,Checking of leakage, Supply of chemicals, repairment/ replacement of Electro- mechanical components etc read with condition no: 41 of eNIT .Operation will start immediatelly after completion of the work & Maintenance date will be reckoned from the next day after the expiry date of DLP of the Scheme. ( The payment on A/C of O&M will be released upon sucessful and satisfactory Operation and maintanance dully certified by the Assessment Committee constituted by Executive Engineer which will furnish weekly report. Complete record of the supplies and replacement of parts will be provided by the contrator to the Deptt. by documentary evidence. if the fails to do it, no payment or reduced payment will be made to the as decided by the Committee).For 1st year

1

250000

250000

... More
2nd year

1

375000

375000

... More
3rd year

1

500000

500000

... More
4th year

1

625000

625000

... More
5th year

1

750000

750000

... More
Carriage of materials by mechanical transport including loading, unloading, stacking of materials - SAND: 3 km

1

165

165.84

... More
4 km

1

183

183.58

... More
5 Km

1

200

200.74

... More
Beyond 5 km upto 10 km per km

1

15

15.66

... More
Beyond 10 km upto 20 km per km

1

13

13.09

... More
Beyond 20 km per additional km

1

11

11.04

... More
Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Aggregate Below 40mm : 3 km

1

165

165.84

... More
4 km

1

183

183.58

... More
5 km

1

200

200.74

... More
Beyond 5 km upto 10 km per km

1

15

15.66

... More
Beyond 10 km upto 20 km per km

1

13

13.09

... More
Beyond 20 km per additional km

1

11

11.04

... More
Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Aggregate 40mm and above : 3 km

1

180

180.26

... More
4 km

1

199

199.55

... More
5 Km

1

218

218.19

... More
Beyond 5 km upto 10 km per km

1

17

17.03

... More
Beyond 10 km upto 20 km per km

1

14

14.23

... More
Beyond 20 km per additional km

1

12

12

... More
Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Steel/ CGI Sheets: 3 km

1

147

147.41

... More
4 km

1

163

163.19

... More
5 Km

1

178

178.43

... More
Beyond 5 km upto 10 km per km

1

13

13.92

... More
Beyond 10 km upto 20 km per km

1

11

11.63

... More
Beyond 20 km per additional km

1

9

9.81

... More
Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Cement: 3 km

1

147

147.41

... More
4 km

1

163

163.19

... More
5 Km

1

178

178.43

... More
Beyond 5 km upto 10 km per km

1

13

13.92

... More
Beyond 10 km upto 20 km per km

1

11

11.63

... More
Beyond 20 km per additional km

1

9

9.81

... More
Carriage of materials by manual means including loading, unloading, stacking of materials- (Sand)1st 50m

1

200

200.67

... More
Beyond Ist 50m

1

39

39.74

... More
Carriage of materials by manual means including loading, unloading, stacking of materials- Aggregate Below 40mm :1st 50m

1

200

200.67

... More
Beyond Ist 50m

1

39

39.74

... More
Carriage of materials by manual means including loading, unloading, stacking of materials- Aggregate 40mm and Above 1st 50m

1

216

216.94

... More
Beyond Ist 50m

1

47

47.23

... More
Carriage of materials by manual means including loading, unloading, stacking of materials- Steel/CGI Sheets; 1st 50m

1

249

249.61

... More
Beyond Ist 50m

1

36

36.63

... More
Carriage of materials by manual means including loading, unloading, stacking of materials- Cement 1st 50m

1

116

116.22

... More
Carriage of materials by manual means including loading, unloading, stacking of materials- CementBeyond Ist 50m

1

17

17.05

... More
Supply, installation, testing and commissioning of Advanced Maintenance Free environment friendly Earthing system consisting of 1 no. of 3mtr length, 17.2 mm dia UL certified earth electrode made of high tensile low carbon steel circular rods, molecularly bonded copper on outer surface (minimum copper bonding thickness-250 microns) with GI terminals to connect incoming strips, (Environment friendly backfill compound duly certified as per ANSI/NSF standard 60/Toxic content certificate as safe for use near potable ground water resources strictly as per specification enclosed. Make- SHREE ELECTRODES/OBO BETTERMANN/ERICO(2 Nos UPS and 4 Nos Main L.T Panel/2 Nos Fire Fighting Panel)Earth pit chamber (300mm x 300mm) with CI cover for the above.

1

15800

15800

... More
Providing and Fixing 25 mm x 5 mm Copper Strip in 40 mm dia. G.I Pipe FRL Earth Electrode including connection with Brass nut ,bolt,spring,washer,excavation and refilling etc. as required.

1

1224

1224

... More
Supply, installation, testing and commissioning of lightening conductor made of 25 mm dia 300 mm long copper tube having single prong at top with base plate.

1

1500

1500

... More
Supply, installation, testing and commissioning of 1440 RPM Horizontal pumping unit as per IS 1520 with following specification:- Pump:-Discharge:18000 GPH Head : 46 Mtrs 1.Type :- Horizontal split casing Material of construction: 1.Impeller:- Stainless steel 2.Shaft:- SS410 3.Pump casing:- Cast Iron The pump shall confirm to IS-1520 code MOTOR :-Rating 40HP A) Type :- Horizontal squirrel cage Induction Type B) No of phases: 3 phase 415 V+10%,50 Hz, AC supply C) Winding:-Copper wound squirrel cage D) Type of enclosure:-SPDP/TEFC E) Method of cooling:- Air cooled with fan mounted F) Method of Starting: star delta The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator. Job includes testing and commissioning of pumping unit on full load at site. Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item and pumping unit is to be approved from the concerned Sub Divisional office before procuring.

1

480000

480000

... More
Supply, installation, testing and commissioning of 1440 RPM Horizontal pumping unit as per IS 1520 with following specification:- Pump:-Discharge:65000 GPH Head : 46 Mtrs 1.Type :- Horizontal split casing Material of construction: 1.Impeller:- Stainless steel 2.Shaft:- SS410 3.Pump casing:- Cast Iron The pump shall confirm to IS-1520 code MOTOR :-Rating:75 HP A) Type :- Horizontal squirrel cage Induction Type B) No of phases: 3 phase 415 V+10%,50 Hz, AC supply C) Winding:-Copper wound squirrel cage D) Type of enclosure:-SPDP/TEFC E) Method of cooling:- Air cooled with fan mounted F) Method of Starting: star delta The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator. Job includes testing and commissioning of pumping unit on full load at site. Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item and pumping unit is to be approved from the concerned Sub Divisional office before procuring.

1

775000

775000

... More
Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. All kinds of soil 01 meter from cutting edge

1

464

464

... More
Filling available excavated earth in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift upto 1.5m

1

214

214

... More
Providing and laying of stone soling including manual compaction

1

676

676

... More
Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns

1

278

278.7

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size)

1

7310

7310

... More
Fabrication, Providing and fitting of 90-120 degree bend/elbow to be fabricated out of G.I pipe and flanged on both ends a to make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size: DN 150, Class: C (Heavy)

1

5200

5200

... More
Fabrication, providing and fitting of T -junction out of 1M of pipe with 1ft each arm. The job includes all types of skilled labour,arrangement of power supply/diesel generator set etc required for the job including P/F of table 17 flanges, suitable size nuts, bolts and RI gasket in the flanged joints on three ends. The size of the Tee is given Below: Size: 150mm, Class: C

1

6500

6500

... More
Providing and fitting of Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units. The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 Nos. M.S flanges (Table flanges) perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Size: DN 150 PN:1.6/16

1

28574

28574

... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 Nos. M.S flanges (Table flanges) perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Size: 150 mm PN: 1.6/16

1

35200

35200

... More
Fabrication of gantry mechanism/CGI shed/ Angle iron bed by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded.I

1

138

138.2

... More
Providing, installation and testing of manual type triple spur gear chain pulley block along with monorail geared travelling trolley having following features Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported and Specially designed, perfectly machined wheel providing correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Capacity = 3 Ton No. Of load chain falls = 2 or above Min. Height of lift = 6 M

1

62972

62972

... More
Supply, installation, commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions: Input =11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. Rating: 100 KVA HT Transformer, 3 phase (Level 2).

1

227000

227000

... More
Providing and fitting of Prodigy LT meter of following specification complete with all fixtures required for fitment at site for above mentioned scheme Type: E3L 100, 3-phase, 4-wire. Measurements offered: KWh, KVARh, KVAh, KVA. Voltage: 2240 V(415 V) 50 Hz, Ib: 40 A, Imax: 200 A, Battery: Lithium

1

28000

28000

... More
Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps.

1

130

130.2

... More
Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs.

1

11730

11730

... More
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation .

1

4982

4982

... More
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing , Station Type .

1

7753

7753

... More
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm

1

345

345.27

... More
Supply, installation, errection of 9 mtrs long H.T pole of specifications ST- 410 (SP-33). The job further includes drilling of holes for installation of various accessories .wherever required. The job further includes GI wire earthing of pole as per REC standard.

1

20868

20868

... More
P/F of Galvanized nuts, bolts of various sizes as per site requirement.

1

142

142

... More
P/F Danger Plate with clamps

1

154

154

... More
Providing and fixing G.I Barbed wire for anti climbing

1

136

136

... More
Providing and fixing of anti climbing devices with clamps

1

425

425

... More
Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.

1

5012

5012

... More
Painting of poles with Red oxide

1

310

310

... More
Painting of poles Gravel hooper and gantry mechanism

1

510

510

... More
Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mm ACSR (Galvanised steel reinforced) for fitment of various accessories

1

56

56.2

... More
Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structure at the top having 120˚ angle between arms and each arm having 15˚ inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is to be mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” ( cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code.

1

26500

26500

... More
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: 0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120˚ - 170˚ Lumens: 12000 Operating Temperature: -20˚C to 60˚C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is to be properly fitted on the arm of the pole and connected to the copper wire as directed.

1

9486

9486

... More
Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge.

1

8154

8154

... More
Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.T cable (ABC type ) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 with reinforced wire Phases: Red, Yellow, Blue

1

813

813.91

... More
Providing and fitting of Anchoring clamps comprising clamp body , plastic wedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core, 35 Sq. mm H.T AB Cable.

1

454

454.72

... More
P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer.

1

8949

8949.03

... More
Providing, fitting,testing and commissioning of MN 140 FASD Starter with MNX 140 Contactor, MN 12 relay relay range 90-150A 3 pole 3 phase 50 HZ

1

105000

105000

... More
Providing, fitting, testing and commissioning of 75 KVA voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling : Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion : virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications.

1

179200

179200

... More
Providing, fitting, testing and commissioning of 150 KVA voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling : Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion : virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications.

1

315000

315000

... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 25 sq.mm )

1

1105

1105

... More
Providing and Fitting of 2 Core, XLPE, 1.1KV and 11KV grade Armoured Aluminium Cable conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. i) 10 sqmm, 2 core LT 1.1 KV

1

180

180

... More
Providing and Fitting of 3.5 Core, XLPE, 1.1KV and 11KV grade Armoured Aluminium Cable conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. ii) 120 sqmm, 3.5 core LT 1.1 KV

1

970

970

... More
Providing and Fitting of single-Core, copper pvc insulated Cable, conforming to IS: 694 part 1st for internal connections with crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be copper Thimbled and of appropriate size and connected by hydraulic crimp tool only. Specifications: Single core PVC insulated 35 sqmm

1

580

580

... More
P/I of earthing station for substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size : 80 mm dia , Length : 2000 mm Back fill compound : 30 kg

1

10460

10460

... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate

1

1206

1206

... More
Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet, 2 Nos including cutting, fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint

1

156

156

... More
a) Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6'x3' (6Kg)- 02 No’s ii) Quilt with warm cover size 5'x8' (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of locks.

1

39617

39617

... More
Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply.

1

1901

1901.45

... More
Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each)

1

7350

7350

... More
Providing of 1 KW heat convector for operators for winter season.

1

1206

1206

... More
Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size: 6’×1’6”= 9 sft

1

3998

3998

... More
Supply, installation of 6 kg Co2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The Co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002

1

9400

9400

... More
Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. Size: 4’×6’ out MS ANGLE OF 40X 40X 5 of 36 rft and MS sheet of 1 mm thick total weight of 50.16 kgs

1

250

250

... More
Providing and fitting of 18'' sweep seiling fan of standard make including the cost of all cables, connections, control system along with the speed regulator with control switches for the power supply

1

4500

4500

... More
Carriage of sand , stone aggregate by mechanical transport including loading, unloading and stacking (average distance-5km)

1

205

205

... More
Carriage of soling stone by mechanical transport including loading, unloading and stacking (average distance-5km)

1

231

231.84

... More
Carriage of cement/steel/CGI sheet/GI pipes below 100mm dia and other heavy materials by mechanical transport including loading , unloading and stacking (average distance -25Km)

1

407

407.15



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.