Public Health Engineering Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Health Engineering Department - PHED Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date23 Jan 2023
Closing Date21 Feb 2023
Tender Amount₹ 1,56,62,000
Costs
EMD
₹ 3,13,240Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Electrical And Mechanical Works Along With Laying And Fitting Of Departmental Rising Main To Be Carried Out At Wss Laman Stage 1st And 2nd Under Jjm
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PHE_203251_8Bid Award Id
ViewTender No
PHE/MDNS/NIT/JJM/E-40 of 2022-23Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://http://www.phekashmir.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units .
Size: DN150
PN:1.6/16 Rest of Specification/Details are as per clause 12 of Annexure "C" of SBD
4
-
-
... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. Size: 150mm
PN: 1.6/16 Rest of Specification/Details are as per clause 13 of Annexure "C" of SBD
4
-
-
... More
Providing, fitting, testing and commissioning of Manually operated copper wound, 3-phase, AC power supply multi step voltage stabilizer.
Rating::100KVA Manufacturers test certificate to be apended and rest of specification as per clause 44 of Annexure "C" of SBD for stage 2nd
4
-
-
... More
Creation of pole mounted , outdoor type Electric Sub Station by way of S/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling: ONAN.
Rating: 200 KVA HT Transformer, 3 phase (Level 2). Manufacturers certificate be apended and rest of specification as per cluase 26 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Supply, installation, erection of 9 mtrs long H.T pope of specifications ST410 (SP-33). The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. as per Clause 32 of Annexure "C" of SBD for stage 1st and 2nd
16
-
-
... More
Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole
20
-
-
... More
Providing and fitting G.I Channel /Angle/ Flat /Riser of sizes including clamps as per Clause 27 of Annexure "C" of SBD for stage 1st and 2nd
650
-
-
... More
Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position
consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. as per Clause 28 of Annexure "C" of SBD for stage 1st and 2nd
4
-
-
... More
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation. as per Clause 29 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type as per Clause 30 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm as per Clause 31 of Annexure "C" of SBD for stage 1st and 2nd
50
-
-
... More
Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) as per Clause 61 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Painting of poles Red oxide as per Clause 37 of Annexure "C" of SBD
16
-
-
... More
Painting of poles Aluminum paint as per Clause 38 of Annexure "C" of SBD
16
-
-
... More
P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043 as per Clause 49 of Annexure "C" of SBD for stage 1st and 2nd
10
-
-
... More
P/L of ACSR conductor of size 0.05 as per the relevant IS standard as per clause 78 of Annexure "C" of SBD for stage 1st and 2nd
1600
-
-
... More
Providing and fitting of 3”x5/8” Galvanized nuts and bolts
150
-
-
... More
Providing and fitting of LT Distribution box for H.T transformer with MCCB For incomer and SFU for outgoing circuits as per clause 42 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Distribution Cables:
Providing, Installation, testing of multi-stranded copper conductor PVC insulated single core unsheathed 50mm sq. Copper cable for internal distribution wiring for stage 1st and 2nd
450
-
-
... More
Fabrication Providing and fitting of modular control panel . THE technical details/ Ratings of various components of Modular Control Panel are given Below a. Main Circuit Breaker (Incommer MCCB) of rting = 250Amp With S.C. Breaking Capacity of 50kA
b. Changeover Switch of rating = 200Amp c. Motor Breakup Protection MCCB of rating = 160-200 Amp With S.C. Breaking Capacity of 36kA d. FASD Submersible starter suitable for 75 HP Load with Relay range of 66-110 Amp e. Auxillary MCCB for Heating/Lighting = 63 Amp With S.C. Breaking Capacity of 25kA
f. Capcitor bank of 15KVAr cpacity Rest of Deatils/Technical specification are as per clause 43 (h) of Annexure "C" of SBD
2
-
-
... More
Providing and Fitting of 120 sqmm, single core LT 1.1 KV, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer/DG set to control panel including necessary thimbling, crimping, taping etc.
NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of appropriate size and connected by hydraulic crimp tool only for stage 1st and 2nd
270
-
-
... More
Providing and Fitting of 50 sqmm 3.5 core LT 1.1 KV , XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer/DG set to control panel including necessary thimbling, crimping, taping etc.
NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of appropriate size and connected by hydraulic crimp tool only for stage 1st and 2nd
90
-
-
... More
Steel work in built up tubular (round, square or rectangular hollow tubes, ISMC,ISMB,ISA etc.) trusses, construction of liner etc. including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer , including welding and bolted with special shaped washers etc. complete The drawings and Dimensions for Gantry/Transformer Bed/Pumping Equipment Base will be provided by Site In Charge at the time of execution of job
3150
-
-
... More
Providing, installation and testing of manual type triple spur gear chain
pulley block along with monorail geared travelling trolley having following
features
Make = Reputed make Capacity = 3 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Rest of Deatils/Technical specification are as per clause 24 of Annexure "C" of SBD for stage 1st
2
-
-
... More
Illumination of Premises:
Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.
1) 3 Way Terminal Connector 20 Amp.
2) 3 No MCB 8 Amp. Rest of Deatils/Technical specification are as per clause 50 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole Having following specs:
Input: 90-240 V 50 Hz
Power Factor: 0.9
Rest of Deatils/Technical specification are as per clause 51 of Annexure "C" of SBD for stage 1st and 2nd
8
-
-
... More
Providing and installation of Junction Box with DP 32Amp MCB to serve as amin switch for LED lighting. Rest of Deatils/Technical specification are as per clause 52 of Annexure "C" of SBD
2
-
-
... More
Providing, Installation and testing of 2KVA fully automatic voltage stabilizer . Rest of Deatils/Technical specification are as per clause 53 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter with 12V, 180AH Tubular inverter Battery Rest of Deatils/Technical specification are as per clause 54 of Annexure "C" of SBD
2
-
-
... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen . Rest of Deatils/Technical specification are as per clause 55 of Annexure "C" of SBD for stage 1st and 2nd
20
-
-
... More
TOOL KIT For Maintenance: -
The Tool Kit for maintenance as per detailed specification in cluase 56 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Providing of good quality conveinence and utility items as per details in Caluse 57 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Fabrication of 6’ x 6’ angle iron bed for operators. Rest of Deatils/Technical specification are as per clause 58 of Annexure "C" of SBD for stage 1st and 2nd
189.5
-
-
... More
Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos. Rest of Deatils/Technical specification are as per clause 59 of Annexure "C" of SBD for stage 1st and 2nd
36
-
-
... More
Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply for stage 1st and 2nd
2
-
-
... More
Providing of 1 KW heat convector for operators for winter season for stage 1st and 2nd
2
-
-
... More
Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal Rest of Deatils/Technical specification are as per clause 64 of Annexure "C" of SBD for stage 1st and 2nd
18
-
-
... More
Providing & fitting of lighting points for ( machine room , operators room,) as per site requirement in 1.5 mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit pipe by way, switches, socket modules , regulators ,indicators, 08/10 watt LED lamps Surface light Make. .Included is cost on account of modular switch boards with the wooden frames as per site requirements for stage 1st and 2nd
16
-
-
... More
Providing fitting of heating points in 2.5mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit by way of p / f of 15 Amp switches, 6 pin socket on modular fitting as per site requirements. Heating points are to be connected from main control panel. All accessories required is to be provided by the firm for stage 1st and 2nd
4
-
-
... More
Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. Rest of Deatils/Technical specification are as per clause 65 of Annexure "C" of SBD for stage 1st and 2nd
48
-
-
... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 as per details in Clause 47 of Annexure "C" of SBD for stage 1st and 2nd
Size = 25 Sq mm
50
-
-
... More
Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 100mm Rest of Specification/Details are as per clause 16 of Annexure "C" of SBD for stage 1st and 2nd
2
-
-
... More
Provision for providing laying of essential feeder for stage 1st and stage 2nd
1
-
-
... More
Handling, laying and joining by welding of departmental MS prefabricated 200mm Diameter Medium class MS Rising Mains from Clear water sump to SR
As per detailed specification in cluase 113 of Annexure "C" of SBD
1486
-
-
... More
Providing, fitting and testing of approved quality 200mm dia. sluice valve (01 No), along with 200mm dia. dismantling joint (01 Nos) in the MS Rising Mains at the required location as per the directions of site Engineer. The dismantling joint is to be installed with the sluice valve with the help of flanges including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.
2
-
-
... More
Providing, fitting and testing of approved quality 200mm dia. NRVs (01 Nos), along with 200mm dia. dismantling joints (01 Nos) in the MS Rising Mains at the required locations as per the directions of site Engineer. The dismantling joints are to be fitted with the Non Return valves with the help of flanges including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.
3
-
-
... More
Providing, fitting and testing of approved quality 50mm dia. CI Double Acting Air Release Valves (01 Nos) in the MS Rising Mains at the required locations as per the directions of site Engineer including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.
2
-
-
... More
Providing, fitting and testing of approved quality 200mm dia. Enclosed Type Water Meter ( Bulk Type) (01 Nos) in the MS Rising Mains at the required locations as per the directions of site Engineer including all welding charges, cost of nuts /bolts, rubber washer, testing of joints.
1
-
-
Evaluation Notes How It Works ?