Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date9 Aug 2024
Closing Date16 Aug 2024
Tender Amount₹ 5,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
10HP (Rate to be quoted by the contractor )

1

-

-

... More
Repair to DOL Starter by replacing its damaged over load relay / contactor and testing complete. 7.50 HP ( Rate to be quoted by the contractor )

1

-

-

... More
2.00HP ( Rate to be quoted by the contractor )

1

-

-

... More
1.00HP ( Rate to be quoted by the contractor )

1

-

-

... More
Rewinding of induction motor pumps, blowers, gears, flash mixers and strirrers installed at Filtration plant no. 1,2,3&4 sitlee Job involves the dismantling of motor from bed plate loading and shifting the same to work shop extracting out damaged old winding from slots, insulting the slots properly making and fixing them into slots, making all coil connections, varnishing the stator reassembling the motor, shifting it back to site, fitting it and making proper alignment with pump making of necessary electrical connections and testing it at site on full load job involves cost of material and labour charges including to & from carriages after deducting the cost of material i.e old burnt copper wire 40HP (Rate to be quoted by the contractor)

1

-

-

... More
25HP (Rate to be quoted by the contractor)

1

-

-

... More
15HP (Rate to be quoted by the contractor)

1

-

-

... More
10HP (Rate to be quoted by the contractor)

1

-

-

... More
7.50HP (Rate to be quoted by the contractor)

1

-

-

... More
2.00HP (Rate to be quoted by the contractor)

1

-

-

... More
1.00HP (Rate to be quoted by the contractor)

1

-

-

... More
Providing and installation of 3 Pole Main switches of heavy duty and standard quality confirming to ISI Standards 100AMP (Rate to be quoted by the contractor)

1

-

-

... More
63AMP (Rate to be quoted by the contractor)

1

-

-

... More
32AMP (Rate to be quoted by the contractor)

1

-

-

... More
16AMP (Rate to be quoted by the contractor)

1

-

-

... More
Providing and fixing of 4.00 sqm. 3 core copper cable for filtration plants, chemical houses (Rate to be quoted by the contractor)

1

-

-

... More
Job for repair to blower installed at Filtration plants at Sitlee job includes dismentalling of blower to gear shaft by welding and turning and bearing size at both ends providing and fitting of new mains gear with pin replacement of demo foil Bearing 3208, 4nos oil seal 4 nos repair of body casing by drilling and topping, fitting of new studs and nuts. Job includes repair to pulley by bush fitting turning and boring and key way making job also includes all cost of material and key way making.

1

-

-

... More
Replacing damaged belts and bet bearing with cost of bearing and fitting charges on PS and CF Tanks.

1

-

-

... More
Supply and fitting of LED Lights 85 WATTS

1

-

-

... More
12 WATTS

1

-

-

... More
Providing & laying of internal wiring 1.50 mm2 incl plastic batten.

1

-

-

... More
Providing & Fixing of MCB 16 Amp

1

-

-

... More
32 Amp.

1

-

-

... More
Providing & Fixing of switches 5 Amp.

1

-

-

... More
Providing & Fixing of socket 5 Amp

1

-

-

... More
15 Amp

1

-

-

... More
Providing & Fixing of combined switches 15 Amp.

1

-

-

... More
Providing & Fitting of Tube lights complete 18 Watt

1

-

-

... More
24 Watt

1

-

-

... More
Providing & Fitting of Bulb Holder 7 Watt

1

-

-

... More
9 Watt

1

-

-

... More
Providing & Fitting of thimble bush

1

-

-

... More
Providing & Fitting of Mica Sheets 9”X 6”

1

-

-

... More
11”x 13”

1

-

-

... More
Providing & Fitting of DP / Insulator 100 Amp.

1

-

-

... More
Supply of PVC Tape roll

1

-

-

... More
Supplying installation, testing and commissioning of LED Bulb on the existing angle holder as required ISI Mark 9 watt

1

-

-

... More
Supplying installation, testing and commissioning of LED Bulb on the existing angle holder as required ISI Mark 12 watt

1

-

-

... More
Supplying installation, testing and commissioning of LED Bulb on the existing angle holder as required ISI Mark 20 watt

1

-

-

... More
Supplying installtion, testing and commissioning of ceiling fan 1200mm, including wiring the down rods of standard length (upto 30cm) as required ISI Mark.

1

-

-

... More
Supply, installtion, testing and commissioning of exhaust fan including making good the damage (300mm shutter type)as required ISI mark.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.