Public Health Engineering Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Health Engineering Department - PHED Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date23 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 16,27,158
Costs
EMD
₹ 32,543Document Cost
₹ 200Tender Fee
Refer Documents
Summary
Supply Installation Testing And Commissioning Of Electro Mechanical Equipments At Wss Augmentation Larkipora
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHE_268735_1Tender No
JSD/PHE/MDSA/ e-NIT No. 32 of 23-12-2024Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply Installation Testing and Commissioning of electro mechanical equipments at WSS Augmentation Larkipora
Supply Installation Testing and Commissioning of electro mechanical equipments at WSS Augmentation Larkipora
BOQ Items
... More
Fabrication ,Providing and fitting of 90-120 degree bend/elbow to be fabricated out of Class C GI pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with welded jointson three ends. The job includes nuts, bolts, gaskets etc complete Size : DN 100 , Class "C"
4
3614
14456
... More
Fabrication,Providing and fitting of washout Tee with arm length 1 feet each (Approx). The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. The size of the Tee is given Below:DN= 100 MM
1
5122
5122
... More
Supply, Installation, Testing And Commissioning of Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS 14846 (PN16) in accordance with BS 5163 part 1 and part 2 / EN 1074 Part 1 & 2 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel.
Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work.
The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job.
Size : DN 100mm
2
19094
38188
... More
Size : DN 80mm of pumping equipment is compulsory .
2
15497
30994
... More
Supply, Installation, Testing And Commissioning of Ductile Iron double flanged, Slanted seat swing check valve (NRV) (PN16) 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions.It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work.The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job.The Test Certificates of Check Valves (NRVs) duly stamped by OEM shall be provided at the time of supply of material Size:-DN 100mm
2
20581
41162
... More
Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded
640
111
71040
... More
Earth work in excavation required for installation of gantry
by manual means in trenches for foundation , drains ,pipes , cables (not exceeding 1.5 m
in width ) and for shafts , wells , cesspits and the like not exceeding 10 sqm on plan ,
including dressing of sides and reaming of bottom lift upto 1.5 m , including getting out
excavated earth and disposal of surplus excavated earth as directed in all kinds of soil. (All kinds of soil 01 meter from cutting edge) 0.60 mtrx 0.60mtrx0.60 mtr )x 4= 0.864= cum
0.86
479
414.12
... More
Centering and shuttering including strutting , propping etc. and removal of form work for Foundation , footings , bases for columns
(0.6 mtr x 0.3 mtr) =( 0.18 sqm x 4)x4 = 2.88 =sqm
2.88
286
824.69
... More
Providing and laying of stone soling including manual compaction ( 0.60mtr x 0.60mtrx0.15mtr) =0.054 cum x 4= 0.216 cum
0.22
740
159.84
... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. all work up to plinth level with 1: 2 : 4 mix ( 1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size 0.60 mtrx 0.60mtrx0.60 mtr )x 4= 0.864 =cum
0.86
6591
5694.62
... More
painting of the gantry and plate form of well using one coat of red oxide metal primer and two coats of enamel paint of different shades.
1
3000
3000
... More
Supply, Installation, Testing And Commissioning of outdoor type Electric Sub Station as per the technical specifications given here under -
Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments.
Type: HT/LT Transformer (Level-2)
Capacity:- 200 KVA
Type of cooling: ONAN.
Operating conditions:
Input =11000 volts
Output = 433 volts AC supply in 3- phase.
Terminals:
Input=3 No. HT Brass bush rods with insulators, washer, nuts etc.
Output=4 No. LT Brass bush rods switch insulators, washers, nuts etc.
Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge.
Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.
The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vent and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment.
1
382996
382996
... More
Providing and fitting G.I Channel /Angle/ Flat/ V crosses/ F- tops of sizes including clamps. The job includes fitting of Channels on two poles for the installation of insulators and safety devices, GO Set, Lighting Arrestor etc. It also includes the channels for fitting of LT Meter and LT Distribution Box. The job includes P/F of GI channels at Tapping point for installation of GO Link Set, Pin Insulators Etc as per site requirement Size of Channel= ISMC 75X40MM, ISMC 150X50MM & ISMC 100x50mm
450
123
55350
... More
Supply, Installation, Testing and commissioning of 01 No. Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT pole double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings, operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. The 11 KV AB switches shall conform to IS: 9920 (Part-I to IV). 01 No. GO Set is to be fitted at tapping point and 01 No at HT Transformer (Substation)
2
11730
23460
... More
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.
1
4983
4983
... More
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type.
1
7754
7754.54
... More
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm
20
347
6940
... More
Supply, installation, erection of 9 mtrs long H.T pope of specifications ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per IEC standard.
5
20686
103430
... More
P/F of Galvanized nuts, bolts of various sizes as per site requirement.
35
142
4970
... More
Earth work in excavation required for installation of HT poles by manual means in trenches for foundation , drains ,pipes , cables (not exceeding 1.5 m in width ) and for shafts , wells , cesspits and the like not exceeding 10 sqm on plan , including dressing of sides and reaming of bottom lift upto 1.5 m , including getting out excavated earth and disposal of surplus excavated earth as directed in all kinds of soil. (All kinds of soil 01 meter from cutting edge) 0.6mtr x0.6mtr x 1.65 mtr = 0.594cum x 4=2.376 cumt for all the required equipment.
2.38
479
1138.82
... More
Centering and shuttering including strutting , propping etc. and removal of form work for Foundation , footings , bases for columns
(0.60mtrx0.3mtr)=0.18x 4= 0.72x4= 2.88 sqm
2.88
286
824.69
... More
Providing and laying of stone soling including manual compaction
0.60mtr x0.60mtr x 0.15mtr=0.054 x 4=0.216 cum
0.22
740
159.84
... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. all work up to plinth level with 1: 2 : 4 mix ( 1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size)
0.6mtr x0.6mtr x 1.65 mtr = 0.594cum x 4=2.376 cum
2.38
6591
15660.22
... More
Painting of poles Red oxide
4
306
1224
... More
Painting of poles Aluminum paint
4
510
2040
... More
P/F Danger Plate with clamps on every HT pole
4
153
612
... More
Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices. The barbed wire shall be tightly close wrapped around the pole for 10-12 turns, commencing at 2.50m above the datum line.
3
136
408
... More
Supply, Installation, Testing And Commissioning of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.
2
4922
9844
... More
Supply, installation,testing and commissioning of 11 KVA Disc insulator set 45 KN
1
2500
2500
... More
Supply,installation,testing of 50 sq mm XLPE HT cable (ABC type) of 11 KV Grade with following specifications size cross sectional area in squre mm )=3x50 phases Red, Yellow , Blue
50
930
46500
... More
P/F of 11 KV cable termination kit for connecting 50 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer.
4
8994
35976
... More
Providing and fitting of anchoring clamps comprising of clamp body plastic wedge , steel bill bracket strips and buckles or nuts and bolts required for holding 3 core 50 sq.mm HT AB cable.
2
457
914
... More
Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 0.50 sq.mm ACSR (Galvanized steel reinforced) for fitment of various accessories
200
56
11200
... More
Supply, Installation, Testing And Commissioning of LT Distribution box for H.T transformer to be fitted on GI Channels.
Capacity of transformer: 200KVA
1
105767
105767
... More
Supply, Installation, Testing And Commissioning of PRODIGY LT Meter of following specification complete with all fixtures required for fitment at site
Type: 3 Phase, 4 wire
Measurements offered: KWh, KVARh, KVAh, KVA
Voltage : 3x240V(415v),50HZ
Ib : 40A Imax: 200A
Battery: Lithium
The Prodigy Meter must be fitted inside the Box, that is to be fitted on GI Channels near LT Distribution Box. Both the enclosures must be symmetrical
Sealing /Inspection report of Prodigy meter from JKPDCL (Concerned) is to be submitted by the firm at the time of charging of SUBSTATION.
1
28000
28000
... More
Supply, Installation, Testing And Commissioning of 30 KVA voltage stabilizer as per specifications below:
Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step.
Type of Regulator: Double plate type with electrolytic copper contacts.
Input voltage : 190-400 volts.(3 phase)
Output voltage : 415 ± 10% volts.
Frequency : 50 ±3 C/S.
Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried.
Insulation : Fiber glass insulations to tested parameters.
Cooling : Naturally, Oil cooled (ONAN)
Temp. Rise (Max) : 30°C above ambient
Mounting : On Uni-directional wheels.
Correction rate : 40 volts per step
Wave form distortion: virtually nil
Duty cycle : 100% continuous.
Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators.
Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations.
Load : Three phase induction motor load.
Load Amperes (continuous)
Overload in 24-hours operation: 10% above continuous Ampere rating.
The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s).
Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level.
1
68108
68108
... More
Supply, Installation, Testing And Commissioning of, 3.5-Core, XLPE, 1.1KV and 11KV grade Armored Aluminum Cable conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. 95 sqmm,(Service line from HT Transformer )
80
837
66960
... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below:
16 sq mm
90
711
63990
... More
Supply, Installation, Testing And Commissioning of L.T, 1 core , capable to work up to 1.1 KV , XLPE insulated , galvanized steel strip armored copper cable conforming to IS : 7098(part -1) 1988 With latest amendments to be fitted from modular control panel to stabilizer etc.(interconnecting cable) . The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation wherever required for laying of cable underground (25 sq mm)
90
394
35460
... More
Supply, Installation, Testing And Commissioning of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated GI earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.
Safe earthing electrode size : 80 mm dia ,
Length : 2000 mm
Back fill compound : 30 kg
4
10462
41848
... More
TOOL KIT For Maintenance: -
The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below
shall be of Providing of tool kit consists of following items
i. Double ended Spanner (Chrome plated) 02 sets complete
ii. Double ended Ring spanners chrome plated 02 sets complete
iii. Allen key set black finish 02 sets complete
iv. Combination Pliers insulated with thick C.A sleeve; size in mm 165, 210, 255 each –
02 No.
v. Long nose plier insulated with thick C.A sleeve; size in mm 165, 205 each – 02 No.
vi. Side cutting plier insulated with thick C.A sleeve; size in mm 165, 205 make – 02 No.
vii. Insulated screw Drivers
Blade length in mm Blade dia. in mm Tip dimensions in mm Quantity
50 3 1.6 x 0.4 02
75 3 1.6 x0.4 02
100 3 3 x 0.4 02
125 3.5 3.5 x 0.5 02
150 3.5 3.5 x 0.5 02
200 4 4 x 0.6 02
300 5 5 x 0.8 02
viii. Hammer with handle weight – 110 mg, 340 gm , 600 gm –each – 1No. .
ix. Heavy duty pipe Wrench length in mm - 200, 300, 600 each – 01 No.
x. Electric Multimeter=1No
xi. Digital multimeter – 1No.
xii. Digital Clamp tester capable to measure up to 400A - 1 No.
xiii. Hack saw frame with hack saw blade – 01 no.
xiv. S-16 MXL, S- 16 H X L Socket Set (19 sockets + 6 Accessories) – 01 No.
1
28840
28840
... More
Providing of good quality bedding for night stay/Shift consisting of: i) Mattress with warm cover size 6'x3' (6Kg)- 02 No’s ii) Quilt with warm cover size 5'x8' (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella(utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 16kg Gas cylinder with burner/ stove. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks,
1
39619
39619
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%