Public Health Engineering Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date18 Nov 2024
Closing Date4 Dec 2024
Tender Amount₹ 1,37,11,000 
Notes
Download

Costs

Summary

Construction Of Ground Water Based Oht At Tail Ends Of Distribution System With Complete Electromechanical System Having 50000g Capacity Oht At Malabagh (including Operation And Maintenance)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:1 meter from cutting edge. All kinds of soil :

1

479

479.3

... More
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: 2.9.1 All kinds of soil :

1

256

256.85

... More
Providing and laying of dry stone soling in foundation/trenches hand packed and consolidated by hand ramming. (Subject to actual quantities during execution).

1

937

937.9

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:

-

-

-

... More
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

1

4826

4826.5

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

1

5202

5202.9

... More
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1

5733

5733.6

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

1

6540

6540.45

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level.

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

7788

7788.4

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9395

9395.7

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9821

9821.85

... More
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with:

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

10377

10377.15

... More
Reinforced cement concrete work in chimneys, shafts upto floor five level including curing complete but excluding the cost of centering, shuttering, finishing and reinforcement with:

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9588

9588.05

... More
Providing and laying upto floor v level reinforced cement concrete in kerbs, steps and the like including curing but excluding the cost of centering, shuttering, finishing and reinforcement with

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

1

9023

9023.35

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.

-

-

-

... More
All works upto plinth level.

1

8021

8021.1

... More
All works above plinth level upto floor V level.

1

9412

9412.05

... More
Extra for R.C.C./B.M.C./R.M.C. work above floor V level for each four floors or part thereof.

1

280

280.95

... More
Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein at 5Qtl. Per Cum .

1

941

941

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately.

-

-

-

... More
Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

1

98

98.8

... More
Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete mix, diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) By percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete,

-

-

-

... More
450 mm dia piles

-

-

-

... More
M-25

1

1941

1941.9

... More
M-30

1

1957

1957.55

... More
M-35

1

1973

1973.3

... More
500mm dia Piles

-

-

-

... More
M-25

1

2275

2275.5

... More
M-30

1

2294

2294.8

... More
M-35

1

2314

2314.25

... More
600mm dia Piles

-

-

-

... More
M-25

1

3095

3095.25

... More
M-30

1

3123

3123.1

... More
M-35

1

3151

3151.1

... More
750mm dia Piles

-

-

-

... More
M-25

1

4693

4693.95

... More
M-30

1

4737

4737.4

... More
M-35

1

4781

4781.1

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer-in Charge.

-

-

-

... More
Single pile upto 50 tonne safe capacity

-

-

-

... More
Initial test (Test Load 2.5 times the safe capacity)

1

159533

159533

... More
Routine test (Test Load 1.5 times the safe capacity)

1

175486

175486.6

... More
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.

1

167

167.8

... More
Open timbering in trenches including strutting and shoring complete (measurements to be taken of the face area timbered):

-

-

-

... More
Depth not exceeding 1.5 m.

1

127

127.1

... More
Depth exceeding 1.5 m but not exceeding 3 m

1

134

134.45

... More
Depth exceeding 3 m but not exceeding 4.50 m

1

146

146.55

... More
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil.

1

24

24.12

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

1

12

12.49

... More
Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared.

1

6

6.35

... More
Centering and shuttering including strutting, propping etc. and removal of form for:

-

-

-

... More
Foundations, footings, bases of columns etc. for mass concrete.

1

286

286.35

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

1

628

628.95

... More
Suspended floors, roofs, landings, balconies and access platforms.

1

718

718.2

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers

1

577

577.55

... More
Columns, pillars, piers, abutments, posts and struts.

1

742

742.55

... More
Stairs (excluding landings) except spiral staircases.

1

851

851.15

... More
Spiral staircases (including landings)

1

676

676.25

... More
Arches, domes, vaults upto 6 m span

1

2281

2281.2

... More
Extra for arches, domes, vaults exceeding 6m span

1

1118

1118.85

... More
Chimney and shafts

1

628

628.95

... More
Extra for shuttering in circular work (20% of respective centering and Shuttering items)

-

-

-

... More
Foundations, footings, bases of columns etc. for mass concrete.

1

57

57.27

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

1

125

125.79

... More
Suspended floors, roofs, landings, balconies and access platforms.

1

143

143.64

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers

1

115

115.51

... More
Small surfaces such as cantilever ends, brackets and end of steps, caps and bases to pilasters and column and the like.

1

1027

1027.4

... More
Edges of slabs and breaks in floors and walls

-

-

-

... More
Under 20 cm wide

1

262

262.2

... More
Above 20 cm wide

1

1145

1145.1

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (plan area to be measured)

1

293

293.9

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

1

123

123.2

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete

1

120

120.8

... More
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded

1

138

138.2

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.

-

-

-

... More
Hot finished welded type tubes

1

156

156.95

... More
Hot finished seamless type tubes

1

171

171

... More
Electric resistance or induction butt welded tubes

1

142

142.9

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.

-

-

-

... More
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete.

1

141

141.4

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

1

181

181.6

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.

-

-

-

... More
M.S. tube

1

161

161.05

... More
E.R.W. tubes

1

154

154.7

... More
G.I. pipes

1

197

197.45

... More
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

1

706

706.5

... More
Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.

-

-

-

... More
0.50 mm thick with zinc coating not less than 275 gram/m2

1

690

690.85

... More
Providing and fixing plained eaves boarding. 2nd class kail wood (300x40 mm (nominal size).

1

1007

1007.5

... More
Providing and fixing of 0.5mm colour G.S Sheet Sofit boarding including Backing, Supports etc. Complete job.

1

600

600

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. NOTE:- To be used for maintenance work judicially necessary deduction for scaffolding in the existing item to be done

1

265

265.3

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

1

218

218.4

... More
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete

1

1204

1204.5

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate

1

510

510.25

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation & plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)

1

7571

7571.55

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level.

1

1455

1455.65

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Kiln seasoned and chemically treated hollock wood

1

74353

74353.45

... More
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Kiln seasoned and chemically treated hollock wood (35mm thick)

1

3091

3091.7

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Second Class kail wood

1

2305

2305.7

... More
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Kiln seasoned and chemically treated hollock wood (35mm thick)

1

3086

3086.95

... More
Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.0mm thick glass panes

1

1210

1210

... More
6mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand).

1

241

241.25

... More
12mm Cement plaster finished with a floating coat of neat cement of mix:

-

-

-

... More
1 : 3 ( 1 cement : 3 fine sand)

1

370

370.75

... More
1 : 4 ( 1 cement : 4 fine sand)

1

353

353.1

... More
15mm Cement plaster on the rough side of single or half brick wall of mix:

-

-

-

... More
1 : 4 ( 1 cement : 4 fine sand)

1

327

327.85

... More
1 : 6 ( 1 cement : 6 fine sand)

1

306

306.85

... More
Extra for plastering exterior walls of the height more than 10m from ground level for every additional height of 3m or part thereof.

1

71

71.55

... More
Extra for plastering Spherical Ceiling

1

141

141

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm).

1

98

98.75

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete. Serrated with central bulb (225 mm wide, 8- 11mm thick)

1

283

283.25

... More
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)

1

64

64.6

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.

1

66

66.85

... More
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work

1

136

136.75

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

1

194

194.65

... More
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

-

-

-

... More
1 mm thick

1

138

138.1

... More
2 mm thick

1

181

181.05

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats

1

86

86.65

... More
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

1

157

157.3

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete

1

1229

1229.1

... More
Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

1

1106

1106.05

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. s required.Upto 450mm Sweep

1

450

450

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.

1

5493

5493.25

... More
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore .

1

334

334.7

... More
Providing and fixing gyser of capacity 25Ltr. Of quality make (Havells, Haquar, Crompton etc. including all required fittings and accessories complete Job).

1

8000

8000

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

1

4172

4172.4

... More
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.

1

129

129.1

... More
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

1

1474

1474.15

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

1

8

8.75

... More
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases & making good the wall etc. PN-16 pipe , 25mm OD(SDR-7.4)

1

461

461.9

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : i. 100 mm inlet and 100 mm outlet Sand cast iron S and S as per IS:3989

1

1556

1556.4

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink: Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.

1

596

596.3

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms

1

731

731.25

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm

1

6166

6166.9

... More
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931

1

582

582.35

... More
Providing and fixing PTMT stop cock of approved quality and color. 15 mm nominal bore, 86 mm long, weighing not less than 88 gms.

1

203

203.55

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement)

1

63

63

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.

-

-

-

... More
Using M.S. angles 40x40x6mm for diagonal braces

1

5493

5493.9

... More
Using flats 30x6mm for diagonal braces and central cross piece.

1

5338

5338.5

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cove

1

2916

2916.1

... More
Providing and fixing ball bearing for rolling shutters.

1

531

531.55

... More
Supply, installation, testing and commissioning of Advanced Maintenance Free environment friendly earthing system consisting of 1 No. of 3 Mtr. Length 17.2mm dia UL certified earth electrode made of high tensile low carbon steel circular rods, molecularly bonded copper on outer surface (minimium copper bonding thickness – 250 microns) with GI terminals to connect incoming strips (Environment friendly backfill compound duly certified as per ANSI / NSF standard 60/Toxic content certificate as safe for use near potable ground water resources strictly as per specification enclosed. Make : Shree Electrodes / OBO Bettermann / Erico (2 No. UPS and 4 No. Main L.T Panel / 2 No. Fire Fighting Panel).

-

-

-

... More
Earth pit chamber (300mm x 300mm) with CI cover for the above.

1

15800

15800

... More
Providing and fixing of 25mm x 5mm Copper Strip in 40mm dia GI Pip FRL earth Electrode including connection with brass nut, bolt, spring, washer, excavation and refilling etc. as required.

1

1224

1224

... More
Supply, installation, testing and commissioning of lightening conductor made of 25mm dia 300mm long copper tube having single prong at top with nase plate.

1

1500

1500

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1

207

207.35

... More
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. :

-

-

-

... More
250x10 mm

1

373

373.35

... More
100x10 mm

1

159

159.85

... More
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.

-

-

-

... More
125 mm

1

68

68

... More
100 mm

1

60

60

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:

-

-

-

... More
2nd class teak wood ( 50 x 12 mm).

1

214

214.75

... More
Providing and installing of PVC pipes (working pressure 4kg/cm2) single socketed pipe 110mm /80mm dia with all necessary arrangements and fittings including Tee’s, Elbows and End Caps wherever required complete job.

1

427

427

... More
Providing and fixing of 0.63mm thick PGI sheets at construction joints including all leads and lifts complete hob as directed by Engineer – Incharge.

1

800

800

... More
Providing and carrying out wiring for heating points with 4.0Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular combine S&S 16Amp along wit the modular plate, suitable GI box and erarthing the point with 2Sqmm FRLS PVC insulated copper conductor single core cable etc. As required (including the cost of conduit).

1

1400

1400

... More
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:

-

-

-

... More
1:3:6 or richer mix (i/c equivalent design mix)

1

1725

1725.2

... More
1:4:8 or leaner mix (i/c equivalent design mix)

1

1064

1064.55

... More
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar

1

1458

1458.45

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead :

-

-

-

... More
Of area of 3 sqm. and below

1

285

285.25

... More
Of area beyond 3 sqm

1

390

390.5

... More
Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead :

-

-

-

... More
Of sectional area 40 sqcm. and above.

1

3488

3488.65

... More
Of sectional area below 40 sqcm.

1

13

13.95

... More
Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 meters lead as per direction of Engineer-in-charge:

1

2

2.8

... More
Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet

1

125

125.35

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking the clods and mixing with sludge or manure in the ration of 8:1 (8 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of sludge or manure after reduction by 8 %), flooding with water, filling with the earth if necessary, watering and finally fine dressing, leveling etc. including stacking & disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 mtr. and lift upto 1.5 mtr. complete (cost of sludge, manure or extra earth to be paid for separately)

1

225

225.65

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work)

-

-

-

... More
15 mm dia. nominal bore

1

206

206.5

... More
20 mm dia. nominal bore

1

255

255.2

... More
25 mm dia. nominal bore

1

339

339.25

... More
32 mm dia. nominal bore

1

411

411.3

... More
40 mm dia. nominal bore

1

489

489.25

... More
50 mm dia. nominal bore

1

805

805.7

... More
65 mm dia. nominal bore

1

1018

1018.05

... More
80 mm dia. nominal bore

1

1151

1151.2

... More
100 mm dia. nominal bore

1

1434

1434

... More
150 mm dia. nominal bore

1

2256

2256.9

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)

-

-

-

... More
65 mm nominal bore

1

1646

1646.05

... More
50 mm nominal bore

1

986

986.15

... More
40 mm nominal bore

1

834

834.6

... More
25mm nominal bore

1

691

691.7

... More
20 mm nominal bore

1

513

513.4

... More
Supply installation testing and commissioning of non returning valve.

-

-

-

... More
65 mm nominal bore

1

4500

4500

... More
Providing, fabricating, fixing of M.S fittings viz bends of suitable degrees / size to be fabricated out of 8mm to 10mm thick MS. plate as per the requirement of site. This item includes cost of lead, spun yarn, R.I. cloth and lead caulking, lead beating with insertion of spun yarn etc. The fittings should be leak proof and should be painted with Anticorrosive Red Oxide Primer and incld. all carriages, leads lifts, etc. complete.

1

260

260

... More
Providing and fixing D.I. Slucie Valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately confirming to IS:14846 read with latest amendments.

-

-

-

... More
80mm dia Class 1

1

15000

15000

... More
100mm dia Class 1

1

20000

20000

... More
125mm dia Class 1

1

25000

25000

... More
150mm dia Class 1

1

30000

30000

... More
200mm dia Class 1

1

40000

40000

... More
250mm dia Class 1

1

60000

60000

... More
300mm dia Class 1

1

72000

72000

... More
350mm dia Class 1

1

140000

140000

... More
Providing and laying flanged C.I. / D.I standard specials such as tees, bends, collars, tapers, caps etc ., suitable for flanged jointing as per IS : 1538

-

-

-

... More
Up to 300 mm dia.

1

8539

8539.2

... More
Over 300 mm dia.

1

8806

8806.75

... More
Providing, fixing of M.S flanges by welding including cost of cutting making both holes made out of 10/14mm thick M.S plate to the pipes of different dia’s and including cost of nuts, bolts, washers etc. (Complete Job).

-

-

-

... More
65mm dia

1

900

900

... More
80mm dia

1

950

950

... More
100mm dia

1

1100

1100

... More
125mm dia

1

1200

1200

... More
150mm dia

1

1300

1300

... More
200mm dia

1

1400

1400

... More
250mm dia

1

1800

1800

... More
Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :

-

-

-

... More
75x63x3.2 mm

1

78

78.2

... More
 100x63x4 mm

1

106

106.85

... More
Supplying and fixing of following modular switch / socket on the existing modular plate and switch box including connecitons but excluding modular plate etc. as required.

-

-

-

... More
5/6A Switch

1

103

103

... More
3 Pin 5/6A Socket outlet 6Amp

1

122

122

... More
3 Pin 5/6A Socket outlet 16Amp

1

156

156

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm

1

809

809.9

... More
Midium class double flanges with gasket 65mm dia nominal bore (GI Inlet Pipe from OHT to Collection Chamber).

1

1015

1015.85

... More
Midium class double flanges with gasket 80mm dia nominal bore (GI Suction Pipe from Collection Chamber to borewell / tube well).).

1

11449

11449

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS : 8329

-

-

-

... More
100 mm dia Ductile Iron Double Flanged

1

1530

1530.6

... More
150 mm dia Ductile Iron Double Flanged

1

2295

2295.65

... More
Providing and laying D.I. Specials of Class K-12 suitable for mechanical jointing as oer IS:9523 Upto 600mm dia.

1

17971

17971.65

... More
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.

1

2516

2516.85

... More
Steel reinforcement for R.C.C. work ready to use "cut and bend"rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more

1

116

116.25

... More
Providing and fixing ventilator of size 450mm x 450mm made out of angle iron 40mm x 40mm with wire mesh of 25mm x 25mm size including welding charges and including all carriages upto site of work.

1

1500

1500

... More
Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete.

1

346

346.7

... More
Providing and fixing aluminum round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-charge. Anodized (AC 15) aluminum

1

89

89.15

... More
Providing and installing 8W Round Led Ceiling Light including wiring Switch boxes MCCB sockets ON and OFF 25mm complete PVC pipe.

1

2000

2000

... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil :

1

91

91.75

... More
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :

-

-

-

... More
150x10 mm

1

83

83.8

... More
200x10 mm

1

95

95.35

... More
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge :Above 40 mm nominal bore

1

121

121.65

... More
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage

1

554

554.1

... More
Carriage of material by mechanical transport including loading, unloading, stacking of material.

-

-

-

... More
Sand/Aggregate below 40mm for an avg. lead of 15Kms.

1

344

344.49

... More
Aggregate 40mm for an avg. lead of 15Kms.

1

374

374.09

... More
Stone Soling for an avg. lead of 17Kms.

1

436

436.11

... More
Steel / CGI Sheets for an avg. lead of 10Kms.

1

248

248.03

... More
Earth an avg. lead of 15Kms.

1

430

430.62

... More
Cement avg. lead of 5 Kms.

1

178

178.43

... More
Head Load :

-

-

-

... More
Sand/Aggregate below 40mm for an avg. lead of 150 Mtr.

1

288

288.05

... More
Aggregate 40mm for an avg. lead of 150 Mtr.

1

311

311.4

... More
Stone Soling for an avg. lead of 150 Mtr.

1

338

338.88

... More
Steel / CGI Sheets for an avg. lead of 150 Mtr.

1

322

322.8

... More
Earth an avg. lead of 150 Mtr.

1

288

288.05

... More
Cement avg. lead of 150 Mtr.

1

150

150.32

... More
Electro Mechanical componants

-

-

-

... More
Bore well Station

-

-

-

... More
Supply, Installation, Testing & Commissioning of Submersible Pumping Unit as per IS 8034 with following specifications are as under: PUMP: Discharge= 4000 GPH Head= 35 Meter Speed = 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled = Clear Water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. NON RETURN VALVE: Non Return Valve of the suitable size provided above the pump discharge case. MOTOR: Motor Rating: As suitable for above parameters Method of starting = Star – Delta Speed = 3000 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Class of insulation = F Submersible motor should be water filled water lubricated squirrel cage type having capacity for above pumping parameters and working on 3 phases; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor filled water. a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length. b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of thickness at other end for column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing. The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site. Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item Make: Kirloskar/KSB

1

65000

65000

... More
Providing and fitting of Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units.The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc. required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges (Table flanges) perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. 65 mm PN 1.6 (Make: VAG/Sigmaflow/Talis)

1

12590

12590

... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges (Table flanges) perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. DN 65 PN 1.6 (Make: VAG/Sigmaflow/Talis)

1

14200

14200

... More
Providing and fitting of G.I flanged delivery line from the pumping unit up to the sump including fabrication of the washout at site. The Pipe shall be hot dip Galvanized, class C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 5 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. The job includes Providing and fitting of 90-120 degree bend/elbows/Tee to be fabricated out of Class C GI pipes flanged on both ends a to make it leak proof as per the site requirement. Flanges (as per IS 6392/1997 Table:5) Thickness shall conform to IS 6392 Part 1st Table-5. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode: DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts of required size. Rubber Insertion Gaskets: Rubber Insertion Gaskets to be used between flanged joints. Part of the pipe is to be utilized for column pipe for the well that are to be supplied in 10 feet length each with flanges cut to pass through submersible cable. The main technical specifications of the pipe are given here under: ND= 65 mm Class: C (Heavy)

1

1214

1214

... More
Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class: IP-55 & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER with current density of suitable rating for 100 Ampere. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards. b) Main Circuit Breaker (Incomer MCCB): Qty. = 01 No. of poles = 4 Pole Current Rating = DN2-250N, 160-200 A. Rated operational voltage = 415 V + 15 % Rated frequency = 50+/-3%Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50 KA Type of release = Thermal-Magnetic Overload protection = 0.8 – 1×ln adjustable Short-circuit protection = 6-10×ln adjustable. c) Change over Switch: Qty. = 01 No. Rating = 200 A Type = Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz.

-

-

-

... More
d) Motor Back-up Protection MCCB: Qnty = 3 No No. of poles = 3P Current Rating = DN0-125D, 100-125 A Rated operational voltage = 415 V +15 % Rated frequency = 50 + 3% Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36 KA e) Submersible starters = Fully automatic star-delta Type: MU-G20 Power Specs = 3 Ф, 415 + 15% V, 50 + 3 % Hz. Relay range = 13-21 A Coil Voltage = 380 v Protection = single phasing , phase Reversal, phase unbalance (55 ± 5 V) , Qty. = 3 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty. = 1 No. No. of poles = 4P Current Rating = 63 A Rated operational voltage = 415 V + 15 % Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = As per requirement g) Motor Protection Relay: MM10 Digital Motor Protection Relay with LCD Display for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, over current, prolong starting, Locked Rotor, Under voltage, over voltage & Earth fault.

-

-

-

... More
h) M-power module for mobile starter for submersible motor 1P/3P 3 wire IVRS Languages – English , Hindi, The panel shall be provided with phase indicators (03 N0) and digital ammeter of range 0-60 A, digital voltmeter of range 0-500 V, and digital frequency meter (01 No for each starter). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and powder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements.

1

210000

210000

... More
Providing, fitting, testing and commissioning of voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling : Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion : virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations. Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. 25 KVA

1

58000

58000

... More
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. 10mm

1

610

610

... More
Providing and Fitting of 3.5 core XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. 50 sq.mm , 3.5core

1

497

497

... More
Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate. The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO.

1

6447

6447

... More
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of pole Having following specs: Input: 90-240 V 50 Hz Power Factor: 0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120˚ - 170˚ Lumens: 12000 Operating Temperature: -20˚C to 60˚C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68 and is to be fitted as per site conditions and instructions of engineer in charge.(Providing of Arms of LED is included in job)

1

9486

9486

... More
Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.

1

34053

34053

... More
Providing of good quality bedding for night stay/Shift consisting of: - Mattress with warm cover size 6'x3' (6Kg)- 02 No’s Quilt with warm cover size 5'x8' (6Kg)- 02 No’s Pillows with covers - 02 No’s Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton

1

39619

39619

... More
Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size: 6’×1’6”

1

3998

3998

... More
Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipment installed at site. Size: 4’×6’ out MS angle of 40X 40 X 5mm and MS sheet of 1 mm thick.

1

250

250

... More
Providing/fitting of manual type chain pulley block having following features: Make = INDEF/Pull lift Capacity = 2MT No. Of chain falls = 4 Min. Height of lift = 6 M Gears: - The hoist shall have precision cut super and helical gears made of alloy steel mounted on bearings and housed in a dust proof gear box. The lubrication of gears be of high viscosity and temperature for longer life of gears. Load Chain: - The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- Specially designed, perfectly machined wheel providing correct grip of load chain made of malleable cast iron makes the hoist most safe and reliable against any failure.

1

28000

28000

... More
Supply, installation, commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions: Input =11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica gel crystals, conservator with oil level indicator, explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. 63KVA

1

171963

171963

... More
Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps for the transformer bed and for the tapping point of suitable size or as per the direction of site engineer.

1

123

123

... More
Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs.

1

12000

12000

... More
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation

1

4983

4983

... More
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing , Station Type .

1

7754

7754

... More
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creep distance 320 mm

1

347

347

... More
P/F of Galvanized nuts and bolts of various sizes as per site requirement.

1

142

142

... More
P/F Danger Plate with clamps

1

150

150

... More
Providing and fixing G.I Barbed wire for anti-climbing

1

136

136

... More
Providing and fixing of anti-climbing devices with clamps

1

409

409

... More
Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 No- turn buckle, 1.8 m long , 16mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.

1

4922

4922

... More
Painting of poles Red oxide

1

306

306

... More
Painting of poles Aluminum paint

1

510

510

... More
P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and 100 KVA HT transformer.

1

8994

8994

... More
Providing and fitting of GI earthing rod for earthing of HT poles as per REC standard.

1

659

659

... More
Providing and fitting of prodigy LT meter of following specification complete with all fixtures required for fitting at site for above mentioned scheme. Type: E3L 100, 3-phase, 4-wire Measurements offered: KWh, KVARh, KVAh, KVA Voltage: 240 V (415 V) 50Hz, Lb:40 A, Imax= 200A Battery: Lithium (SECURE)

1

25000

25000

... More
P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size : 80 mm dia , Length 2000 mm Back fill compound : 30 kg

1

10462

10462

... More
Sump Station

-

-

-

... More
Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per IS 14220. PUMP: - Type of pump : Open well Submersible Pump (Horizontal) Discharge: 8000 GPH Head: 30 Quality of Water to be handled : Filter water METERIAL OF CONSTRUCTION: Pump Casing : Cast Iron Impeller : SS Pump Shaft : Stainless Steel 410 Motor Body : Cast Iron/SS Sealing : mechanical seal The bowl plate shall be provided with name plate giving complete specifications MOTOR: - Rating: suitable for above specification Method of starting: Star – Delta/DOL (as specified). Frequency : 50Hz + 3% Voltage : 415 + 6 %, - 15% 3 phase Class of insulation: Suitable for above rating. Sealing : Dual mech. seal. Provided with thermal and overload protection The motor shall be made of corrosion resisting materials to resist corrosion under normal conditions and the motor shall have a name plate giving complete specifications. Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item Make: Kirloskar/KSB

1

48000

48000

... More
Providing and fitting of Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges (Table flanges) perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. 80 mm PN 1.6 (Make: VAG/Sigmaflow/Talis)

1

15497

15497

... More
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges (Table flanges) perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. DN 80 PN 1.6 (Make: VAG/Sigmaflow/Talis)

1

17489

17489

... More
Providing and fitting of G.I flanged delivery line from the pumping unit up to the OHT foot including fabrication of the washout at site. The Pipe shall be hot dip Galvanized, class C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. The job includes Providing and fitting of 90-120 degree bend/elbows/Tee to be fabricated out of Class C GI pipes flanged on both ends a to make it leak proof as per the site requirement Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode: DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts of required size. Rubber Insertion Gaskets: Rubber Insertion Gaskets to be used between flanged joints. The main technical specifications of the pipe are given here under: ND= 65 mm Class: C (Heavy)

1

1214

1214

... More
O & M

-

-

-

... More
For 1st Year (After DLP is over)

1

120000

120000

... More
For 2nd Year

1

130000

130000

... More
For 3rd Year

1

140000

140000

... More
For 4th Year

1

150000

150000

... More
For 5th Year

1

160000

160000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.