Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Eprocure
Opening Date23 Jun 2021
Closing Date26 Aug 2021
Tender Amount₹ 61,97,000
Costs
EMD
Refer DocumentsDocument Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_PDD_128243_1Bid Award Id
ViewTender No
EE/TLMDA/16 OF 2021Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Galvanised Nuts & Bolts of sizes
0.6
-
-
Auxiliary Transformer
-
-
-
250KVA, 3 phase, 33/0.44kV Power Transformer including all accessories, auxillaries and marshalling boxes/ kiosks, complete in all respects as specified in the technical specification.(Energy efficiency Level-2)
1
-
-
Main Equiupments
-
-
-
Circuit breakers
-
-
-
3 pole, 36kV,1250Amp, 50c/s, 25kA, Vaccum Circuit Breakers out door type with offered operating mechanism, all accessories,clamps, auxiliaries and marshalling boxes / kiosks etc. complete in all respects as specified in the technical specification
1
-
-
Isolators
-
-
-
36 kV, 50 c/s, 2500 Amps,25kA for 3 Sec, horizontal double break, outdoor type manual operated 3 pole isolators with all accessories, auxiliaries,clamps, marshalling boxes, other essentials, complete in all respects as specified in the technical specification without earthing blades
2
-
-
Current Transformers
-
-
-
Single phase, 50 c/s 36 kV Current Transformers (20-10-5/1-1-1 A , 25kA for 1 sec, rated dynamic current 25kA(peak), class A insulation, Burden 20 VA inlcluding first fill of transformer oil plus 10% etc and all accessories , auxiliaries etc complete in all respects.
3
-
-
Surge Arrestor
-
-
-
Single phase, 50 c/s, outdoor, metal oxide gapless type arresters including surge counters / monitors, insulating base and all associated accessories, clamps, auxiliaries, complete in all respects as specified in the technical specification 30 KV(RMS)
3
-
-
Control and relay panel
-
-
-
Control & Relay panel for 33 kV Auxilary bay (scada compatible) completely wired including substation automation supporting IEDs/numerical relays.(As per site requirement and having 110V DC voltage )
1
-
-
Servo Stabliser
-
-
-
100KVA servo stabliser 3-phase 4 wire copper wound indoor type,input voltage range 220-460V ,output 400+ 1% in two parts of oil cooled and air cooled having digital control, Response time 10ms,automatic switch-off against: under voltage,over voltage & short circuit,single phase,class C type secondary surge protection
1
-
-
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable for DC supply complete as per specification.
-
-
-
2 core, 2.5 sq mm
610
-
-
4 core, 2.5 sq mm
630
-
-
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded aluminium conductor power cable for AC supply .3.5 core, 25 sq mm
200
-
-
Cable Glands, ferrules & Lugs for all above cables etc.
1
-
-
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self-supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
1
-
-
Conductor and Hardware fittings
-
-
-
200mm2 ACSR PANTHER Conductor (a)Aluminium =30/3.53 mm (b) Steel= 7/3.53 mm
400
-
-
Single Tension Fittings For Single 200mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
12
-
-
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
40
-
-
T Clamps 200mm2 /200mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
21
-
-
CT Clamps 200 mm2 ,made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
6
-
-
Pad Clamps 200mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
18
-
-
P G Clamps 200mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
6
-
-
Earth Wire 7/3.15mm
150
-
-
Earth Wire 7/3.15mm Tension Clamps comprise of compression type tension clamp with 2 'D' shackles, jumper terminals, nuts and bolts and washers etc slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire.
6
-
-
Cable Trays/ Cable Racks/ Accessories
-
-
-
Cable tray of size 400mm * 3000mm made of MS angle, 40*40*6mm, 40*6 Flat
60
-
-
Cable tray of size 300mm * 2500mm made of MS angle, 40*40*6mm, 40*6 Flat
36
-
-
Earthing Mat
-
-
-
Earth Mat (40mm dia steel bars) as per approved design,galvanised Iron (75mm*12mm/ 50mm * 6mm)
100
-
-
(B) HANDLING, STORAGE, PRESERVATION, ERECTION (EXCEPT CIVIL WORKS), DEHYDRATION, TESTING & COMMISSIONING OF EQUIPMENTs AND MATERIAL
-
-
-
Structures
-
-
-
Erection of 33 KV structure.
9
-
-
Galvanised Nuts & Bolts of sizes
0.6
-
-
Auxiliary Transformer
-
-
-
250KVA, 3 phase, 33/0.44kV Power Transformer including all accessories, auxillaries and marshalling boxes/ kiosks, complete in all respects as specified in the technical specification.(Energy efficiency Level-2)
1
-
-
Main Equiupments
-
-
-
Circuit breakers
-
-
-
3 pole, 36kV,1250Amp, 50c/s, 25kA, Vaccum Circuit Breakers out door type with offered operating mechanism, all accessories,clamps, auxiliaries and marshalling boxes / kiosks etc. complete in all respects as specified in the technical specification
1
-
-
Isolators
-
-
-
36 kV, 50 c/s, 2500 Amps,25kA for 3 Sec, horizontal double break, outdoor type manual operated 3 pole isolators with all accessories, auxiliaries,clamps, marshalling boxes, other essentials, complete in all respects as specified in the technical specification without earthing blades
2
-
-
Current Transformers
-
-
-
Single phase, 50 c/s 36 kV Current Transformers (20-10-5/1-1-1 A , 25kA for 1 sec, rated dynamic current 25kA(peak), class A insulation, Burden 20 VA inlcluding first fill of transformer oil plus 10% etc and all accessories , auxiliaries etc complete in all respects.
3
-
-
Surge Arrestor
-
-
-
Single phase, 50 c/s, outdoor, metal oxide gapless type arresters including surge counters / monitors, insulating base and all associated accessories, clamps, auxiliaries, complete in all respects as specified in the technical specification 30 KV(RMS)
3
-
-
Control and relay panel
-
-
-
Control & Relay panel for 33 kV Auxilary bay (scada compatible) completely wired including substation automation supporting IEDs/numerical relays.(As per site requirement and having 110V DC voltage )
1
-
-
Servo Stabliser
-
-
-
100KVA servo stabliser 3-phase 4 wire copper wound indoor type,input voltage range 220-460V ,output 400+ 1% in two parts of oil cooled and air cooled having digital control, Response time 10ms,automatic switch-off against: under voltage,over voltage & short circuit,single phase,class C type secondary surge protection
1
-
-
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable for DC supply complete as per specification.
-
-
-
2 core, 2.5 sq mm
610
-
-
4 core, 2.5 sq mm
630
-
-
10 core, 2.5 sq mm ( will be provided by Corporation)
1100
-
-
16 core, 2.5 sq mm ( will be provided by corporation)
200
-
-
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded aluminium conductor power cable for AC supply .3.5 core, 25 sq mm
200
-
-
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded aluminium conductor power cable for AC supply .3.5 core, 35 sq mm ( will be provided by the corporation)
150
-
-
Cable Glands, ferrules & Lugs for all above cables etc.
1
-
-
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self-supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
1
-
-
Conductor and Hardware fittings
-
-
-
200mm2 ACSR PANTHER Conductor (a)Aluminium =30/3.53 mm (b) Steel= 7/3.53 mm
400
-
-
Single Tension Fittings For Single 200mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
12
-
-
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
40
-
-
T Clamps 200mm2 /200mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
21
-
-
CT Clamps 200 mm2 ,made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
6
-
-
Pad Clamps 200mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
18
-
-
P G Clamps 200mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
6
-
-
Earth Wire 7/3.15mm
150
-
-
Earth Wire 7/3.15mm Tension Clamps comprise of compression type tension clamp with 2 'D' shackles, jumper terminals, nuts and bolts and washers etc slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire.
6
-
-
Cable Trays/ Cable Racks/ Accessories
-
-
-
Cable tray of size 400mm * 3000mm made of MS angle, 40*40*6mm, 40*6 Flat
60
-
-
Cable tray of size 300mm * 2500mm made of MS angle, 40*40*6mm, 40*6 Flat
36
-
-
Earthing Mat
-
-
-
Earth Mat (40mm dia steel bars) as per approved design,galvanised Iron (75mm*12mm/ 50mm * 6mm)
100
-
-
(C) Civil Works including design, supply, execution and prepration of drawings
-
-
-
Foundations for equipment structure including laying of earthing mat, 33 kv column structures
-
-
-
Excavation in all type of soils including mixed soils (i.e. soils containing pebbles/boulders etc.) for any section including all labour, POL, hire charges of equipments and T&Ps etc. including sheeting & shoring, dewatering, lifting, handling and stock piling of excavated materials, back filling with excavated or borrowed earth and disposal of surplus excavated earth as directed for all leads & lifts complete as per specification, construction drawings and direction of Engineer-in-charge.
62
-
-
Providing and laying of stone soling hand packed Including cost of all materials, labour, hire charges of equipments and T&P, POL, etc complete for handling, transportation, batching, placing.
5
-
-
Supply and Fixing of foundation bolts (M24) including alignment
40
-
-
Fabrication,galvanisation, supply including packing and forwarding, transportation charges of stub legs for 33 KV Column structures.
552
-
-
High yield strength cold deformed steel reinforcement bars conforming to IS: 1786 for R.C.C. or any other work including the cost of all materials, binding wire, labour, hire charges of equipments and T&P, bending, binding, placing and tieing in position, POL etc. complete as per specification, construction drawings and direction of Engineer-in-charges.
1300
-
-
Plain cement concrete of specified grade and strength conforming to IS: 456 placed as sub-base under structural concrete or as shown in approved construction drawings at all levels including cost of all materials, labour, hire charges of equipments and T&P, POL, shuttering etc complete for handling, transportation, batching, mixing, placing, vibrating, compacting, leveling, curing etc. as per specification, construction drawings and direction of Engineer-in-charge.
-
-
-
Concrete of M-7.5 grade having cube strength of 7.5 N / mm2 with 40 mm nominal size coarse aggregate.
5.85
-
-
Structural cement concrete ( plain/ reinforced) of specified 28 days strength (nominal size of coarse aggregate 20 mm) at all levels, including cost of all materials, labour, hire charges of equipments and T&P, POL, shuttering, curing, etc complete for handling, transportation, batching, mixing, placing, vibrating, and rendering, cleaning and finishing the exposed over ground surfaces with cement mortar 1:3 (1 cement : 3 sand) to give smooth and even surface, stub setting, fixing of foundation bolts ( as applicable) but excluding the cost of reinforcement complete as per specification, construction drawings and direction of Engineer-in-charge.
-
-
-
Concrete of M-15 grade having cube strength of 15 N / mm2 with 20 mm nominal size coarse aggregate.
20
-
-
(d) Concreting and laying of yard metal for 33KV bays
-
-
-
Surface dressing of ground,removal of inequalities less than 15 cms (Devegitation) 1500sqm
350
-
-
Earth work in excavation of 33KV yard along with old laid gravel completely embedded under vegetation like grass, bushes Tree branches etc. including removal of unhygenic material, gravel & earth by way of screening, washing of gravel and disposal of surplus excavated earth and unhygienic material outside yard.
175
-
-
Providing and laying of stone soling hand packed Including cost of all materials, labour, hire charges of equipments and T&P, POL, etc complete for handling, transportation, batching, placing.
30
-
-
M:15 Plain cement concrete of specified grade and strength conforming to IS: 456 placed as sub-base under structural concrete or as shown in approved construction drawings at all levels including cost of all materials, labour, hire charges of equipments ad T&P, POL, shuttering, provision for pipe collars and its fixing at determined places etc complete for handling, transportation, batching, mixing, placing, vibrating, compacting, leveling, curing etc. as per specification, construction drawings and direction of Engineer-in-charge.
35
-
-
Providing/ supply/laying/spreading/levelling of 100 mm thick (compacted tickness) layer of 40 mm nominal size metal over M:10 grade concrete layer & providing the suitable slopes towards the nearest drains including the cost of all materials, labor, higher charges of equipments & T&P, POL etc. complete as per specification, construction drawings and direction of engineer in charge.
35
-
-
(e) Construction of cable trenches for 33KV new Auxillary bay.
-
-
-
Excavation in all type of soils including mixed soils (i.e. soils containing pebbles/boulders etc.) for 1 no. 33KV new Auxillary bay and from exsisting cable trenches to newly constructed control room including all labour, POL, hire charges of equipments and T&Ps etc. including sheeting & shoring, lifting, handling and stock piling of excavated materials and disposal of surplus excavated earth as directed for all leads & lifts complete as per specification, construction drawings and direction of Engineer-in-charge.
48
-
-
Providing and laying of stone soling for 1 no. 33KV new Auxillary bay hand packed including cost of all materials, labour, hire charges of equipments and T&P, POL, etc complete for handling, transportation, batching, placing.
5
-
-
High yield strength cold deformed steel reinforcement bars conforming to IS: 1786 for R.C.C. or any other work including the cost of all materials, binding wire, labour, hire charges of equipments and T&P, bending, binding, placing and tieing in position, POL etc. complete as per specification, construction drawings and direction of Engineer-in-charges.
900
-
-
Plain cement concrete of specified grade and strength conforming to IS: 456 placed as sub-base under structural concrete or as shown in approved construction drawings at all levels including cost of all materials, labour, hire charges of equipments and T&P, POL, shuttering etc complete for handling, transportation, batching, mixing, placing, vibrating, compacting, leveling, curing etc. as per specification, construction drawings and direction of Engineer-in-charge.
-
-
-
Concrete of M-7.5 grade for 1 no. 33KV new Auxillary bays having cube strength of 7.5 N / mm2 with 40 mm nominal size coarse aggregate.
5
-
-
Structural cement concrete ( plain/ reinforced) of specified 28 days strength (nominal size of coarse aggregate 20 mm) at all levels, including cost of all materials, labour, hire charges of equipments and T&P, POL, shuttering, curing, etc complete for handling, transportation, batching, mixing, placing, vibrating, and rendering, cleaning and finishing the exposed over ground surfaces with cement mortar 1:3 (1 cement : 3 sand) to give smooth and even surface, stub setting, fixing of foundation bolts ( as applicable) but excluding the cost of reinforcement complete as per specification, construction drawings and direction of Engineer-in-charge.
-
-
-
Concrete of M-15 grade having cube strength of 15 N / mm2 with 40 mm nominal size coarse aggregate.
20
-
-
Providing and fixing covers at all levels including cost of all materials, labour, hire charges of equipments and T&P, POL, curing etc. complete for finished item of work as per specification, construction drawings and direction of Engineer-in-charge.
-
-
-
Pre-cast R.C.C. covers made of M-25 grade concrete
60
-
-
Providing, fabricating and Fixing of angle iron 50*50*6 for base and brackets/trays and cleats,flat iron 110x10mm for holding of brackets/trays properly grouted into concrete, flat iron 65x8mm for hooks and end brackets etc ( complete Job)
850
-
-
Plain cement concrete of grade M15 for providing slope in cable trenches of specified grade and strength conforming to IS:456 including cost of all materials, labour, hire charges of equipments and T&P, POL, handling, transportation, batching, mixing, curing, etc. complete for finished item of work as per specification, construction drawings and direction of Engineer-in-charge.
3
-
-
(f) Shifting of various equipments including carriage, installation , testing and commissioning of the same to newly constructed control room of grid station LJHP
-
-
-
Dismantling, loading, unloading , carriage of two no. 132KV and 33 KV transformer C/R pannels, Battery bank and battery charger installed in old C/Room at LJHP yard ,and re-installing of the same including its testing and commissioning at newly constructed Control Room.
1
-
-
Installation , testing and commissioning of 03 No. 33 KV C&R feeder pannels, LT Pannels ( AC and DC Distribution Pannels) at new control room of GSS LJHP.
1
-
-
Dismantilling of Old used Laid Power and Control Cables from Old C/room and re-using/laying for new C/Room where ever usable.Dismantelling of chain link fencing for cable trench,refixing,repairs of drain and form work for cable trench near drain portion (appox length 5m)
1
-
-