Power Development Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Power Development Department - PDD Tender

Works
Eprocure
Opening Date12 Jun 2024
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Description

lockUnlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

lockUnlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Promotion Banner

BOQ Items

... More
DO_NOT_SHOW

-

-

-

lockView all details for FREE
... More
20 MVA 132/33 KV

1

-

-

... More
40 MVA 220/132 KV

1

-

-

... More
Draning of transformer oil of transformers

1

-

-

... More
Filling of oil, filitration and dehydration of transformer including installation of vacume pump to be provided by the Department.

1

-

-

... More
Reparing of cooling fans of transformers including replacement of damaged winding, bearing etc.

1

-

-

... More
Lifting of top lid of power transformer for complete physical inspection & replacement of gaskets.

1

-

-

... More
Replacement of damaged core bolts/Earthning strip etc.

1

-

-

... More
Testing of Transformer:-

-

-

-

... More
Testing of Transformer:- tandelta testing of bushing/ winding & BDV testing of transformer oil. (TESTING KIT WILL BE PROVIDED BY DEPARTMENT)

1

-

-

... More
DGA and PPM of Transformer from accredIted laboratories.

1

-

-

... More
Replacement of damaged/outlived bushing having high tan delta including crane/ mechanical equipment if required.

-

-

-

... More
220 KV Bushing

1

-

-

... More
132 KV Bushing

1

-

-

... More
33 KV Bushing

1

-

-

... More
Overhauling of Circuit Breaker :- VCB/MOCB/SF6 Checking of oil/gas pressure drop during duty cycle operation check, Checking of auto-starting / stopping of oil pump,pressure switch setting,etc, Checking of healthiness of accumulator by checking the pre-charging pressure when building up pressure from zero, Checking of operation of safety valve, Cleaning of breaker units, checking of protection equipments and replacement of defective ones, i.e., complete inspection and testing of SF6/VCB/MOCB type circuit breakers inclusive of operating mechanism.Checking of driving mechanism, trip/closing circuits/ checking of spring charge motor and checking of tripping and closing coils.checking of equipment earthing and strucure earthing. Maintaning gas levels, venting of circuit breakers, replacement of o-rings , gas kits including circuit breaker anylysis by Circuit breaker analyser.Checking of space heater and illumination.Required as per schedule of maintenance

-

-

-

... More
220KV SF6 Breaker

1

-

-

... More
132KV SF6/MOCB Breaker

1

-

-

... More
33 KV VCB

1

-

-

... More
Replacement of damaged pole of the circuit Breaker including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.220KV SF6 Breaker

1

-

-

... More
Replacement of damaged pole of the circuit Breaker including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.132KV SF6/MOCB Breaker

1

-

-

... More
Replacement of damaged pole of the circuit Breaker including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.33 KV VCB

1

-

-

... More
CVT's /CT's /PT's :- Visual checking of earthing HFpoint (in case it is not being used for PLCC,Checking of any breakage or cracks in porclean insulator, Cleaning of CVT capacitor stacks and tightness of terminal connections,Checking and tightness of all connections including earth connections.Checking of healthiness of gaskets, Checking of neutral earthing in CVT, healthiness of all gaskets and oil level and its topping.Measurement of IR value and tightening of all connections and droppers.Primary injection test of CT/PT, Tan delta,knee point value, burden etc.

-

-

-

... More
220 KV

1

-

-

... More
132 KV

1

-

-

1

-

-

... More
Replacement of damaged CT/PT including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.

-

-

-

... More
220 KV

1

-

-

... More
132 KV

1

-

-

1

-

-

... More
Surge Arrestors :- Checking of leakage current(third harmonic resistive current), Testing of counters and leakage current meters, Cleaning of insulators, Checking of earth connections between surge arrester,surge monitor and earth, Checking of leakage current after cleaning of porcelain surface, cleaning of LA insulators. Measurement of IR value and tightening of droppers.

-

-

-

... More
220 kV

1

-

-

... More
132 kV

1

-

-

... More
33 KV

1

-

-

... More
Replacement of damaged Surge Arrestor including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.

-

-

-

... More
220 kV

1

-

-

... More
132 kV

1

-

-

... More
33 KV

1

-

-

... More
Isolators :- Maintenance of linkages including transmission gears, stopper bolts. Cleaning of auxiliary switch contacts and greasing with silca grease, cleaning of support insulators, termination contacts, checking of elecctrical / mechanical interlocks with E/S and CB, mounting bolts, alignment, nuts, pins, space heater, illumination, healthiness of gaskets, auxiliary contacts, alignment of earthing blades, operation of earth switch, almunium / copper flexible conductor, earth connections of structures and MB. lubrication of operating mechanism, hinges lock joints, levers, bearings, main contacts, cleaning of post insulators, tightening of clamps.

-

-

-

... More
220 kV

1

-

-

... More
132 kV

1

-

-

1

-

-

... More
Replacement of damaged Isolators including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.

-

-

-

... More
220 kV

1

-

-

... More
132 kV

1

-

-

1

-

-

... More
Reparing of Three phase motors of isolators including replacement of damaged winding and bearing.

1

-

-

... More
Droppers/Jumpers Replacement of damaged / burnt droppers or jumpers of isolators/ breakers/transformers /CT/PT etc. 220/132/33 KV Yard.

1

-

-

... More
Clamps: Replacement of damaged/burnt PG/ PAD/T/CT/Bushing clamp etc

1

-

-

... More
Post Insulators :- Checking of insulators for cracks and cleaning of insulators and its replacemnt.

-

-

-

... More
220 kV

1

-

-

... More
132 kV

1

-

-

1

-

-

... More
Illumination System :- Checking of healthiness of fittings in station buildings, outdoor switch yard, Tightening of terminals, etc.

1

-

-

... More
Battery Bank: Checking and cleaning of battery cell terminals, application of patrolum gelly, if required, conduction of battery impendence test and discharge test checking voltage temperature, current, sp. Gravity of individual cells as well as terminals voltage, battery dischrge testing etc.Checking of positive/Negative earth fault of dc.Terminal tightening.

1

-

-

... More
Battery Charger :- Checking of control cards, measurement of test point voltage values, testing of DC earthfault and U/V relays, IR measurement of charger transformer, checking of earthing etc. Checking of charger panel / DCDB for electrical connections, cleanliness etc.

1

-

-

... More
Protection System :- Checking of relays and application of CCl4 for cleaning, replacement of worn out / defunct relays, checking and replacement of control wiring, if required, primery & secondery injection testing,software settings etc.

1

-

-

... More
Cleaning of cable trenches/ ducts including of dressing of cables, trays, racks , repair of damaged duct covers etc

-

-

-

1

-

-

... More
sub main

1

-

-

... More
T-off

1

-

-

... More
Gantry Columns and Beams :- Tightening of all nuts / bolts and providing of missing nuts / bolts and replacement of damaged members.

-

-

-

... More
220 kV

1

-

-

... More
132 kV

1

-

-

1

-

-

... More
L.T. Transformer :- Testing of oil BDV, IR measurement, Testing /checking of OTI,WTI and Buchholz (if provided, Checking of healthiness of Pressure relief diaphragm, Checking healthiness of Buchholz relay, Checking tightness of earthing connections

1

-

-

... More
L.T Pannel: Cleaning of panels,bus bar insulators etc. Relays Testing, Tightning of all electrical connections,Checking of indicating meters ,Check for change-over facility, if provided,Check operation /indications in OFF Load condition of MCCB,

1

-

-

... More
Earthing Mat :- Measurment of earth resistivity, checking of electrical continuity of equipment earthings, tightening of earthing connectors, removal of rust from bolted earth connectors and tightening and additional earthing wherever required. 220/132/33 kV

1

-

-

... More
earthing of equipment with pipe earthing at 220/132/33 kV alongwith connection to equipment with G.I. Strip

1

-

-

... More
Improvement of earth mat with Spike earthing of 40 mm dia M.S. Rod wherever required

1

-

-

... More
DC Distribution Board :- Checking of connections, wiring, replacement of wiring if needed and checking of healthiness of all D/C and dc circuits of 33/132/220 Kv yards

1

-

-

... More
AC Distribution Board :- Checking of connections, wiring, replacement of wiring if needed,fuses,MCB,bus bar CT, relays,MFM,LT switchs etc and checking of healthiness of all connections and AC circuits of 33/132/220 kv yards.

1

-

-

... More
Replacement of damaged/outlived/burnt control cables of different cores icluding proper ferruling, thimbling and tagging and finally with all appropriate connections including lifting of duct covers upto 10 core

1

-

-

... More
Replacement of damaged/outlived/burnt control cables of different cores icluding proper ferruling, thimbling and tagging and finally with all appropriate connections including lifting of duct covers above 10 core

1

-

-

... More
Marshelling koisk:- checking of all Terminal blocks, space heaters, light illumination, checking of all connnections and its cleaning. Fixing of cable glands earthing and checking of all other electrical accessories .

1

-

-

... More
Capacitor Banks :- Checking/ tightening of capacitor cells terminals, reactor and checking its wiring connection and its control circuit.etc

1

-

-

... More
Replacement of damaged ACSR Conductor along with its fittings.220 kv yard

1

-

-

... More
BUS BAR :- Replacement of damaged ACSR Conductor along with its fittings.132 kv yard

1

-

-

... More
BUS BAR :- Replacement of damaged ACSR Conductor along with its fittings.33 kv yard

1

-

-

... More
Automatic voltage regulator:- checking and tightening of connections, auto control unit, oil and its overhaulling

1

-

-

... More
Diesel Generator set: periodic Maintenance and checking of its operation by way of changing of filters, engine oil, coolant etc

1

-

-

... More
Deweeding, removal of vegetation, cutting of bushes in switch yard

1

-

-

... More
Painting of outdoor equipments (Transformers, MK's, CT/PT/CVT, Protection wall, Circuit breaker, isolatores, poles etc. including cost of painting material, one coat of red oxide wherever required and two coat of enamel spray paint

1

-

-

... More
Painting of equipments & gantry column beam structures including cost of painting material, one coat of red oxide wherever required and two coat of enamel spray paint

1

-

-

... More
AC Units: Checking and Servicing of Installed AC unit inside control room (1- 3 Ton)

1

-

-

... More
Preparation of surface by scrapping old white wash, applying one coat of cement primer for Control Room/Residencial Quarters/Office building

1

-

-

... More
White-Washing of Control Room/Residencial Quarters/Office building by using two coat of oil bound distemper

1

-

-

... More
Repairing of Sanitary installed in the control romm/ office building/division building/residential quaters/Toilts and replacement of any damaged item if required. (lab. Only)

1

-

-

... More
Repairing of electrical accessories installed in the control romm/ office building/division building/residential quaters/Toilts and replacement of any damaged item if required. (lab. Only)

1

-

-

... More
Providing of skilled/ semi skilled/ un skilled labour for the works under this division which are not covered in this BOQ

-

-

-

... More
skilled labour

1

-

-

... More
semi- skilled

1

-

-

... More
un skilled

1

-

-

... More
Store Handling

-

-

-

... More
Unloading / Loading of C&R Panels, in divisional store Including manual Carriage within store yard).

1

-

-

... More
Unloading / Loading of ,angle iron, Tor steel , tower material in divisional store Including manual Carriage within store yard).

1

-

-

... More
Unloading / Loading of CT/CVT/PT/PI etc in divisional store Including manual Carriage within store yard).

1

-

-

... More
Unloading / Loading of CB/LA/Isolators/ etc in divisional store Including manual Carriage within store yard).

1

-

-

... More
MT Carriage of T&P and other allied material from Divsional Stores to site of work and back carraige of T&P and material including halt at site till completuion of work

-

-

-

... More
First 20 Km

1

-

-

... More
Next Km upto 250 km

1

-

-

... More
Replacement of Pad clamps Moose/Zebra/ Panther

1

-

-

... More
Replacement of T clamps Moose/Zebra/ Panther

1

-

-

... More
Replacement of PG clamps Moose/Zebra/ Panther

1

-

-

... More
SITC of Pad clamps Moose/Zebra/ Panther

1

-

-

... More
SITC of T clamps Moose/Zebra/ Panther

1

-

-

... More
SITC of PG clamps Moose/Zebra/ Panther

1

-

-

... More
Concreting of yard as per directions of Engineer Incharge including material

1

-

-

... More
Laying Of Gravel of appropriate size including material

1

-

-

... More
Replacement of Galvanised Iron of various sizes

1

-

-

... More
Replacement of Galvanised Nut and Bolts of various sizes

1

-

-

... More
Replacement of Turn Buckle alongwith U Clamp

1

-

-

... More
SITC of Galvanised Iron of various sizes

1

-

-

... More
SITC of Galvanised Nut and Bolts of various sizes

1

-

-

... More
SITC of Turn Buckle alongwith U Clamp

1

-

-

... More
Repair of Cable Ducts (complete job)

1

-

-

... More
P/F of Cable ducts cover made of Reinforcement Cement concrete (1:2:4) cover as per site, as per design Steel bar and angle iron frame to be provided by the department

1

-

-

... More
Laying Of foundations of Gantry and other equipments with material, reinforcement 1:11/2:3 complete job as per design to be provided by the department

1

-

-

... More
Transmission line S/C and D/C :- ( Including carriage of T&P from stores and Shutdown Factor)

-

-

-

... More
Checking and tightening of jumpers

1

-

-

... More
Replacement of burnt /damaged jumpers and tightening of remaining jumpers on the same location

1

-

-

... More
Fixing of damper/vibrator on earthwire/ACSR Conductor

1

-

-

... More
Replacement of damaged disc insulators

-

-

-

... More
Tension string

1

-

-

... More
Suspension string

1

-

-

... More
Repairing of power conductor when lowering of conductor is necessary. Complete job including laying of conductor, making of compression joint, if any, rough sagging tensioning of conductor, fixing dead end assembly etc. upto span of 500 meter.

1

-

-

... More
Repairing of power conductor when lowering of conductor is necessary. Complete job including laying of conductor, making of compression joint, if any, rough sagging tensioning of conductor, fixing dead end assembly etc. beyond 500 m - 1000 mtr

1

-

-

... More
Repairing of power conductor when lowering of conductor is necessary. Complete job including laying of conductor, making of compression joint, if any, rough sagging tensioning of conductor, fixing dead end assembly etc. beyond 1000 mtr

1

-

-

... More
Laying,Stringing and saging of ACSR conductor including sagging, tensioning, fitting of dead end assamblies etc.(complete job)

1

-

-

... More
Repairing of ground wire when lowering of conductor is necessary. Complete job including laying of conductor, making of compression joint, if any, rough sagging tensioning of conductor, fixing dead end assembly etc. upto span of 500 meter tension

1

-

-

... More
Laying,Stringing and saging of ground wire including sagging, tensioning, fitting of dead end assamblies etc.(complete job)

1

-

-

... More
Tower S/C and D/C:-

-

-

-

... More
Tightening of nuts and bolts of tower superstructures replacement of missing ones.

-

-

-

... More
a) Tower weight more than 4 tonnes to 7.5 tonnes

1

-

-

... More
b) Tower weight more than 7.5 tonnes

1

-

-

... More
Checking / tightening of tower footing earthing bolts and measuring tower footing resistance.

1

-

-

... More
Branch cutting: under the coridor of 132 KV S/C and D/C transmission line 16 mtr and under tower structure

1

-

-

... More
Branch cutting: under the coridor of 220 KV S/C and D/C transmission line 20 mtr and under tower structure

1

-

-

... More
Replacement of missing tower members

1

-

-

... More
Reparing damaged conductor by using helical sleeve or Bolted or by shorting method with out lowering. The conductor

1

-

-

... More
Dismantling and refixing of anti-climbing device/Bird Guard over S/C & D/C tower

1

-

-

... More
Fixing of phase plates/No. plates/danger plates over S/C & D/C tower

1

-

-

... More
Fixing of repair sleeves compression type for over ACSR conductor

1

-

-

... More
Cutting of vegetation from the tower platform including disposal

1

-

-

... More
Removal of slip from tower platform and catch water drain including disposal

1

-

-

... More
Filling of earth in tower platform including excavation and manual carraige to the site

1

-

-

... More
Repairing of crates by way of binding of opened crated with binding wire( B.wire to be provided by the contractor)

1

-

-

... More
Repair of Foundation by way of Providing RCC in ratio not less than M15. (with material) complete job

1

-

-

... More
Repair of protection wall in 1:6 RR (with material) complete job

1

-

-

... More
Store handling:

-

-

-

... More
Unloading / Loading of T&P Material for Transmission Line works including Four Sheaves pulley,Pulleys,Ropes,Compression machine etc in divisional stores including manual carriage within store yard.

1

-

-

... More
Unloading / Loading of Cement in divisional store Including manual Carriage within store yard).

1

-

-

... More
Unloading / Loading of Disc Insulators/Fittings in divisional store Including manual Carriage within store yard).

1

-

-

... More
Fabrication of Tower members anchor blocks and other Angle/steel works etc

1

-

-

... More
Unloading / Loading of conductor/control cable etc in divisional store Including manual Carriage within store yard).

1

-

-

... More
Sorting of tower material/ stacking including manual Carriage within store yard).

1

-

-

... More
Emergency Restoration Works and Other Works under various heads (Transmission Lines)

-

-

-

... More
Dismantling of ACSR Panther Conductor

1

-

-

... More
Dismantling of ACSR Zebra Conductor

1

-

-

... More
Installation of insulator strings complete with necessary hardware, laying and stringing of ACSR Zebra Conductor including fixing of conductor accessories (Complete Job)

1

-

-

... More
Installation of insulator strings complete with necessary hardware, laying and stringing of ACSR Panther Conductor including fixing of conductor accessories (Complete Job)

1

-

-

... More
Dismantling of earthwire

1

-

-

... More
Laying and stringing of earthwire (Complete Job)

1

-

-

... More
Dismantling of Tower (Snow Zone)

1

-

-

... More
Dismantling of Tower (Non-Snow Zone)

1

-

-

... More
Erection of Tower alongwith nutbolt and other accessories (Snow Zone)

1

-

-

... More
Erection of Tower alongwith nutbolt and other accessories (Non -Snow Zone)

1

-

-

... More
Erection of ERS including fixing of 16 No.Guys after emebedding the Guy platesin Pits after exacavation of PIT size 1.5 Mtr x.1.5Mtr. x 3Mtr and backfill

1

-

-

... More
Dismantling of ERS alongwith dismantling of Guys Complete Job

1

-

-

... More
Dismanting of damaged Protection wall in 1:6 RR Masonary

1

-

-

... More
Removing of damaged mulba

1

-

-

... More
Protection Work to tower in 1:6 RS (Complete job with material)

1

-

-

... More
Catch Water Drain0.8x0.8 in 1:6 RSM (Complete job with material)

1

-

-

... More
Survey works of Transmission Line 220/132 KV including preparation of Google sheet, profile, tower spotting

1

-

-

... More
Excavation in DFR foundation

1

-

-

... More
Excavation in DRY foundation

1

-

-

... More
Excavation in WET foundation

1

-

-

... More
Excavation in PS foundation

1

-

-

... More
Excavation in FS foundation

1

-

-

... More
Benching in all kinds of soil

1

-

-

... More
Benching in hard rock

1

-

-

... More
Laying of foundation of Towers in M5

1

-

-

... More
Laying of foundation of Towers in M7.5

1

-

-

... More
Laying of foundation of Towers in M10

1

-

-

... More
Laying of foundation of Towers in M15

1

-

-

... More
Laying of foundation of Towers in M20

1

-

-

... More
Laying of foundation of Towers in M25

1

-

-

... More
SITC of Reinforcement of all sorts

1

-

-

... More
Construction of Anchoring blocks and fixing of anchors (if anchors to be provided by department)

1

-

-

... More
Construction of Anchoring blocks and fixing of anchors including material and labour

1

-

-

... More
U/L of T&P at site from vehicle

1

-

-

... More
U/L of Tower material at site from vehicle

1

-

-

... More
U/L of conductor, fiitings, discs and other H/W material at site

1

-

-

... More
Carriage of T&Pfrom site to site of work manually

1

-

-

... More
Carriage of TOWER Material from site to site of work manually

1

-

-

... More
Painting of Truck

1

-

-

... More
Routine servicing, changing of oil and tuning of Mahindra Bolero

1

-

-

... More
Routine servicing, changing of oil and tuning of departmental truck

1

-

-

... More
Measuring and cutting of ACSR Zebra conductor at Divisional store

1

-

-

... More
Measuring and cutting of ACSR Panther conductor at Divisional store

1

-

-

... More
Measuring and cutting of E/W at Divisional store

1

-

-

... More
Loading/U/L of ACSR Zebra into vehicle at Store

1

-

-

... More
Loading /U/L of ACSR Panther into vehicle at Store

1

-

-

... More
Loading /U/L of E/W into vehicle at Store

1

-

-

... More
Loading /U/L of Hardware Material into vehicle at Store

1

-

-

... More
Loading /U/L of Tower material into vehicle at Store

1

-

-

... More
Carriage of Tower Material within store premises for sorting of tower material/ cleaning of yards/ verification of material

1

-

-

... More
Carriage/stacking of 33 KV equipments CT/ PT, /PI / at store for loading into vehicle/ cleaning of spaces/ verification of matwerial

1

-

-

... More
Carriage/stacking of 33 KV equipments VCB, /ISOLATORS/LA at store for loading into vehicle/ cleaning of spaces/ verification of matwerial

1

-

-

... More
Carriage/stacking of 132 KV equipments CT/ PT, /PI / at store for loading into vehicle/ cleaning of spaces/ verification of matwerial

1

-

-

... More
Carriage/stacking of 132 KV equipments VCB, /ISOLATORS/LA at store for loading into vehicle/ cleaning of spaces/ verification of matwerial

1

-

-

... More
Carriage/stacking of 220 KV equipments CT/ PT, /PI / at store for loading into vehicle/ cleaning of spaces/ verification of matwerial

1

-

-

... More
Carriage/stacking of 220 KV equipments VCB, /ISOLATORS/LA at store for loading into vehicle/ cleaning of spaces/ verification of matwerial

1

-

-

... More
Carriage of discs insulators from site to site of work manually

1

-

-

... More
Carriage of Tower member, conductor, fiitings and other H/W material from site to site of work manually

1

-

-

... More
P/F B..A wire Knitted crates of size 6 x 1.5 x 1.5 mtrs including carriage upto site

1

-

-

... More
P/F of Steel wire rope of 10/12/16 mm from anchor bolt to tower

1

-

-

... More
Fixing of Steel wire rope of 10/12/16 mm from anchor bolt to tower

1

-

-

... More
Repairing of mesh fencing and barbed wire FENCING

1

-

-

... More
Reconditioning/ repairing /overhauling of HYDRAULLIC compressor

1

-

-

... More
Reconditioning/ repairing /overhauling of Four sheeve pulleys

1

-

-

... More
Loading/unloading of earthing transformer/aux. transformer 33/0.44 KV

1

-

-

... More
Carriage/dragging of earthing transformer/aux. transformer 33/0.44 KV upto 200 mtr.

1

-

-

... More
Loading of Transformer oil

1

-

-

... More
U/Loading of Transformer oil

1

-

-



Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.