Power Development Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Power Development Department - PDD Tender

Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Mar 2023
Closing Date27 Mar 2023
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Summary

E-nit/2022-23/13 Dated 06.03.2022

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rate Contract for Upkeep Maintt. of 66 33 11KV Receiving stations and 66 33KV Lines and Fabrication and Handling of Material of Div. Store Under the Jurisdiction of Sub Transmission Division JPDCL Kathua for the year 2023-24 or till next contract
Rate Contract for Upkeep Maintt. of 66 33 11KV Receiving stations and 66 33KV Lines and Fabrication and Handling of Material of Div. Store Under the Jurisdiction of Sub Transmission Division JPDCL Kathua for the year 2023-24 or till next contract
Rate Contract for Upkeep Maintt. of 66 33 11KV Receiving stations and 66 33KV Lines and Fabrication and Handling of Material of Div. Store Under the Jurisdiction of Sub Transmission Division JPDCL Kathua for the year 2023-24 or till next contract
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Erection of 11 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back.

1

-

-

... More
Erection of 9 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back.

1

-

-

... More
Erection of 9 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back.

1

-

-

... More
Painting of 16 mtr long Steel Tubular Pole including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint

1

-

-

... More
Painting of 13 mtr long Steel Tubular Pole including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint

1

-

-

... More
Painting of 11 mtr long Steel Tubular Pole including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint

1

-

-

... More
Painting of 09 mtr long Steel Tubular Pole including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint

1

-

-

... More
Cement Bottoming in 1:2:4 mix including excavation and form work as per REC Standards. (16/13/11/9 Mtr Long Poles (Complete Job)

1

-

-

... More
Fixing of Galvanised spiral Earthing of SWG No. 8, G.I wire of 115 turns confirming to REC-J1 construction standard, (J1)

1

-

-

... More
Fixing of 66/33KV Galvanised Guy Set (Guy wire, Guy Rods, Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof including digging of pits & refilling

1

-

-

... More
Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (100mm2 ACSR Conductor)

1

-

-

... More
Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (150mm2 ACSR Conductor)

1

-

-

... More
Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (200mm2 ACSR Conductor)

1

-

-

... More
Dismantling of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long ) up to distance of 50 mtr

1

-

-

... More
Dismantling of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long ) up to distance of 50 mtr

1

-

-

... More
Dismantling of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr

1

-

-

... More
Dismantling of PCC Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr

1

-

-

... More
Dismantling of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr

1

-

-

... More
Dismantling of PCC Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr

1

-

-

... More
Dismantling of Three/Four pole structure, opening of channels, crossarms, angles(Complete Job.)

1

-

-

... More
Dismantling of Two pole structure, opening of channels, crossarms, angles(Complete Job.)

1

-

-

... More
Straightening of tilted Steel Tubular Pole (16 mtr. Long )

1

-

-

... More
Straightening of tilted Steel Tubular Pole (13 mtr. Long )

1

-

-

... More
Straightening of tilted Steel Tubular Pole (11 mtr. Long )

1

-

-

... More
Straightening of tilted PCC Pole (11 mtr. Long )

1

-

-

... More
Straightening of tilted Steel Tubular Pole (9 mtr. Long )

1

-

-

... More
Straightening of tilted PCC Pole (9 mtr. Long )

1

-

-

... More
Unloading of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long )up to distance of 50 mtr

1

-

-

... More
Unloading of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long )up to distance of 50 mtr

1

-

-

... More
Unloading of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long )

1

-

-

... More
Unloading of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr

1

-

-

... More
Loading of Steel Tubular Poles including carriage up to dumping site, (16 mtr. Long )

1

-

-

... More
Loading of Steel Tubular Poles including carriage up to dumping site, (13 mtr. Long )

1

-

-

... More
Loading of Steel Tubular Poles including carriage up to dumping site, (11 mtr. Long )

1

-

-

... More
Loading of Steel Tubular Poles including carriage up to dumping site, (9 mtr. Long )

1

-

-

... More
Extra carriage from dumping site, (16 mtr. Long )up to site of work 1st 100 mtr

1

-

-

... More
Extra carriage from dumping site, (13 mtr. Long )up to site of work Ist 100 mtr

1

-

-

... More
Extra carriage from dumping site, (11 mtr. Long )up to site of work Ist 100 mtr

1

-

-

... More
Extra carriage from dumping site, (9 mtr. Long )up to site of work Ist 100 mtr

1

-

-

... More
Unloading of Steel of Sorts , (Steel)

1

-

-

... More
Loading of Steel of Sorts , (Steel)

1

-

-

... More
Unloading of Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor)

1

-

-

... More
Loading of Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor)

1

-

-

... More
Fixing of 66-33 kV Disc Insulator (70 KN) 2008 standards, (Porcelain )

1

-

-

... More
Fixing of 66-33 kV Disc fitting (70 KN) 2008 standards, (Polymer)

1

-

-

... More
Fixing of 66-33 kV Insulators (10 KN) standards, (Porcelain )

1

-

-

... More
Fixing of 66-33 kV Pin Insulators (10 KN) suitable for 100/150/200mm² ACSR Conductor.

1

-

-

... More
Replacement/Fixing of 66-33 kV Tension fittings (Socket & Ball type or T&C Type) for ACSR

1

-

-

... More
Replacement/Fixing of 66-33 kV Tension fittings (Socket & Ball type or T&C Type) for ACSR 150m²

1

-

-

... More
Replacement/Fixing of 66-33 kV Tension fittings (Socket & Ball type or T&C Type) for ACSR 200m²

1

-

-

... More
Straightening of X-arms of different sizes (100x50x50x6 mm channel Iron,50x50x6mm Angle Iron ) duly painted with one coat of red-oxide and two coats of silver paint fixing with different sizes and sorts of nuts,bolts and washers, (Channel Iron X-arms, Angle Iron-X-arms, Pole Tops)

1

-

-

... More
Straightening of angle iron of different sizes (65x65x6 mm channel Iron,50x50x6mm Angle Iron

1

-

-

... More
Repair and re-erection of Cradle for guard netting with GI wire 8no including wire binding, cutting /bending of GI Wire as per REC standards

1

-

-

... More
Branch cutting, 66- 33 kV lines

1

-

-

... More
Removing of wild climbers/vegetation around 66/33 kv Poles

1

-

-

... More
Removing of wild climbers/vegetation around 66/33 kV Tower

1

-

-

... More
Removing of wild climbers from top of 66-33 kV Lines.

1

-

-

... More
Removing of wild climbers from Peak, cage, cross arm of 66-33 kV old tower Line

1

-

-

... More
Patrolling of 66/33 kV Line(Routine/Under fault)

1

-

-

... More
Tightening of loose guys

1

-

-

... More
Dismantling & re-erection of damaged guys including digging of pit & refilling the same

1

-

-

... More
Replacement of damaged Disc insulator in tension string

1

-

-

... More
Replacement of cross arms of sizes 100x50x6

1

-

-

... More
Replacement of angle iron of sizes (65x65x6, 50x50x6)

1

-

-

... More
Replacement of Pin insulator on Four/Three/Double Pole Structure

1

-

-

... More
Replacement of Pin insulator on Single Pole Structure

1

-

-

... More
Replacement of Worn-out/Damaged Jumper of 66-33 kV Tower lines

1

-

-

... More
Replacement of Disc Insulator, Suspension Fitting of 66-33 kV Tower lines

1

-

-

... More
Replacement of worn-out/Loose/Damaged Jumper of 66-33 kV lines

1

-

-

... More
Local earthing of 66/33 kV Lines by way of using discharge/earth rods at faulty site to avoid accident due to any induction while working on Line.

1

-

-

... More
Tightening / restringing of loose ACSR Dog 100 mm2

1

-

-

... More
Tightening / restringing of loose ACSR Wolf 150 mm2

1

-

-

... More
Tightening / restringing of loose ACSR Panther 200 mm2

1

-

-

... More
Dismantling & Re-erection of ACSR Dog 100mm2 including collection of dismantled conductor , making of small bundles and its carriage

1

-

-

... More
Dismantling & Re-erection of ACSR Wolf 150mm2 including collection of dismantled conductor , making of small bundles and its carriage

1

-

-

... More
Dismantling & Re-erection of ACSR panther 200mm2 including collection of dismantled conductor , making of small bundles and its carriage

1

-

-

... More
Dismantling of stay sets complete

1

-

-

... More
Upkeep / Maintenance of 66-33/11 KV Receiving Sub Stations a) Routine maintenance of 66 KV outdoor SF6 by way of tightening of loose nuts and bolts, greasing/lubrication of movable parts, checking the movable alignment of different phases, cleaning of insulating chambers, etc

1

-

-

... More
33 KV VCB Repairs & Renovation by way of b) Setting of Mechanical Assembly / Replacement of damaged spring / Repair of locking & charging system

1

-

-

... More
c) Replacement of Tripping Coil/Closing coil

1

-

-

... More
d) Replacement of Damaged Vacuum Interrupter

1

-

-

... More
e) Replacement of Bushing including Clamps

1

-

-

... More
66 kV C&R Panel: Replacement of different equipment's a) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch ,Selector Switch Identification of Panel Wiring Faults & its rectification

1

-

-

... More
33 kV C&R Panel: Replacement of different equipment's a) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch ,Selector Switch Identification of Panel Wiring Faults & its rectification

1

-

-

... More
b) Replacement of Different Relays - MIT Numerical Relay / Electro-mechanical relay / Master Trip Relay/ Differential Relay/Auxiliary Relay etc.

1

-

-

... More
Installation, Testing, commissioning of 66-33 kV Control Relay Panels (Complete Job)

1

-

-

... More
Complete testing of Relays Setting of Testing Kit, Interconnection between various points of panel with respect to secondary injection key on various current taps, recording the observation thereof. All modifications necessary to achieve desired results.

1

-

-

... More
Control Cable Replacement of damaged Control Cables of all types including binding with PVC Belts/ Binding Wire, Peeling of insulation and fixing of proper size thimble connecting the cable after identification of each core to both ends i.e. Panel to CTs / panel to PTs /panel to Breaker and Making functional of 33 KV Outdoor Breakers, Protection , Alarms, Annunciation (complete Job)

1

-

-

... More
Upkeep of earthing of aux. transformer

1

-

-

... More
Upkeep of earthing of Power transformer

1

-

-

... More
Upkeep of earthing of 66/33/11 kV LA

1

-

-

... More
Providing of extra earthing for improvement purpose (complete job)

1

-

-

... More
Upkeep of earth mat of out door yard

1

-

-

... More
Replacement of damaged earth mesh in Sub-Station as per approved Map & Design.

1

-

-

... More
Excavation of trenches of 0.6 Mtr Depth and 2.0 Mtr wide mtr in normal soil / hard soil

1

-

-

... More
Repairing / Laying of MS Flat and MS Rod in deep excavated trench and welding of MS Flat & MS Rod with Mesh.

1

-

-

... More
Repairing of Earthing with Spikes of MS Rod 20mm, 3 Mtr in Length as per REC Drawing

1

-

-

... More
66-33/11 KV Power Transformer a) Opening of Transformer Tank Top Cover to prevent oil leakage from top (if required to facilitate maintenance of transformer after removing the required accessories), ,Draining/ Re-Filling of required Oil, Change of gaskets of valves/ radiators/ Buchholz's relay radiators valves of power transformer of capacity: 3.15 MVA to 20 MVA

1

-

-

... More
b) Replacement of silica gel

1

-

-

... More
c) General Inspection by through inspection of each individual parts, Ratio test by applying voltage on HV Side and measuring LV Voltage on various Tap Positions, checking of Buchholz relay, Surge relay conservator, sensors, measurement of 1R-Value dialectic strength of oil, cleaning of Power Transformer etc

1

-

-

... More
d) Replacement of any one of the following i.e. temperature indicators, gas operated Buchholz's relay, oil temperature indicator, winding temperature indicator etc

1

-

-

... More
e) Preventing of leakage by changing main gaskets after removing the old gasket

1

-

-

... More
f) Replacement of HV/LV Busing & Bush Rod, Ring and Rubber Washers

1

-

-

... More
g) Cleaning of Scale deposited over the body and radiators of the power transformer with thinner/ detergent and de-rusting in perfect manner.(routine work)

1

-

-

... More
h) Cleaning of LV/HV bushings of Power Transformer(routine work)

1

-

-

... More
i) Replacement of Bus Bars of Power Transformer

1

-

-

... More
j) Replacement of LV/HV clamps of Power Transformer

1

-

-

... More
Oil Topping of Power Transformer 10 MVA to 20 MVA

1

-

-

... More
Oil Topping of Power Transformer 4 MVA to 6.3 MVA

1

-

-

... More
Oil Topping of Power Transformer 3.15 MVA

1

-

-

... More
Recording of IR values of transformers

1

-

-

... More
Installation, Testing and Commissing of Power Transformer 66-33/11 KV Installation of LV/HV Bus Bars with proper care, of transformer for any leakage commissioning of Power of Transformers by applying low voltage approximately equal to impedance voltage on HV Side and short circuiting the LV terminals, Energizing the transformer by applying required primary voltage to it & keeping the transformer on no load to observe the behaviour of transformer, setting on 25% of the load on the transformer for a period of at test 6 hours and observation of oil including temperature, increase the transformer is fully loaded and topping of oil. a) 20 MVA

1

-

-

... More
b) 10 MVA

1

-

-

... More
c) 6.3 MVA

1

-

-

... More
d) upto 5 MVA

1

-

-

... More
Checking and tightening of Jumpers, Droppers in 66/33 KV Outdoor Yard

1

-

-

... More
Replacement of T/PG clamps

1

-

-

... More
Replacement of Disc insulators including its hardware.

1

-

-

... More
66/33 KV LA & 11 KV Stn. Type LA Replacement of 66 KV,33 KV & 11 KV Lightening Arrestor including jumpering and earth connecting in all respect. a) 66 KV LA

1

-

-

... More
b) 33 KV LA

1

-

-

... More
b) 11 KV LA

1

-

-

... More
Separate pipe Earthing / G.I Rod earthing as per REC Drawing

1

-

-

... More
Replacement of pipe earthing / Rod earthing with new one

1

-

-

... More
Installation, testing and Commissioning, replacement of 66 KV Isolators

1

-

-

... More
Installation, testing and Commissioning,replacement of 33 KV Isolators

1

-

-

... More
Replacement of 11 KV Isolators

1

-

-

... More
Repair & Renovation of 66/33 KV and 11 KV isolators including setting right its alignment for proper operation, lubrication/greasing of jaws, bearings operating's handle etc(complete job)

1

-

-

... More
Replacement of worn-out/heated Pad clamp/Isolator clamps of 66/33/11 kV Isolator by way of dismantling. Drilling of holes on new and fixing (complete job)

1

-

-

... More
Repair & Renovation of Isolator Jaws 66/33 KV and 11 KV isolators.(complete job)

1

-

-

... More
Replacement of post insulator / tendon pipes/ operating box by way of dimentalling, necessary fabrication where ever required for proper operation of 66/33/11 kv Isolators.

1

-

-

... More
66-33 KV CTs Installation, testing and Commissioning of 66-33 kV CTs ( of all ratios ) Complete Job

1

-

-

... More
66-33 KV CTs Repairs & Renovation of 66/33 KV CTs by way of replacing shorting strips, connecting rod, transformer oil, damaged insulator (CT's of all ratios)

1

-

-

... More
Replacement of 66 KV Outdoor Type CT of different ratio and dismantling of damaged CT(CT's of all ratios)

1

-

-

... More
Replacement of 33 KV Outdoor Type CT of different ratio and dismantling of damaged CT(CT's of all ratios)

1

-

-

... More
Oil Topping of 66/33 kV CT & PT by way of opening of top cover and refixing with new gaskets if necessary and preventing of oil leakages if any.(complete job)

1

-

-

... More
66-33 kV PTs Installation, testing and Commissioning of 66-33 kV PTs (complete job)

1

-

-

... More
66 kV PTs Replacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure.

1

-

-

... More
33 kV PTs Replacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure

1

-

-

... More
66 KV Post Insulator Replacement of 66 KV Post Insulator and dismantling of damaged PI, dragging to installation/loading site, lifting from ground to steel structure.

1

-

-

... More
33 KV Post Insulator Replacement of 33 KV Post Insulator and dismantling of damaged PI, dragging to installation/loading site, lifting from ground to steel structure.

1

-

-

... More
Cleaning of porcelain bushing, tightening of PT/CT clamps, derusting & painting of body of 66/33 kV PTs & CTs

1

-

-

... More
Tightening of nuts & bolts, replacement of oval thread bolts, chipping by way of welding to the bolts after tightening in a single bay

1

-

-

... More
Painting with mix red oxide paint two coats of approved make on steel works after cleaning with wire brush/ sand paper

1

-

-

... More
Painting of steel structure erected in outdoor yard with aluminium paint two coats with approved brand and fixture to given an even surface

1

-

-

... More
Battery Bank a) Repair & maintenance of battery set including maintaining specific gravity, electrolyte level, cleaning, checking, tightening of battery terminals in all respects it includes measuring voltage of each battery.

1

-

-

... More
b) Tightening of all nut and bolts, replacement of damaged battery cells

1

-

-

... More
c) Installation, testing and Commissioning of Battery Bank (complete Job)

1

-

-

... More
Battery Charger Repair/Renovation battery charger for proper functioning by way of replacement of rectifier unit, Ammeter, Voltmeter, MCB,Cooling fan, LED indications, buzzer alarms for OV/UV etc (Complete Job)

1

-

-

... More
Repair and maintenance of DC Board, identification of fault in respect of cable and its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job.

1

-

-

... More
Repair and maintenance of AC Board, identification of fault in respect of cable and its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job.

1

-

-

... More
Installation, testing and Commissioning of Battery Charger (complete Job)

1

-

-

... More
Deweeding of vegetation in outdoor yard Removing of stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation, levelling the area with existing stone metal

1

-

-

... More
Providing of additional stone metal and its carriage and laying in outdoor yard, this including breaking of stones complete job.

1

-

-

... More
Cleaning of Control Room, removing dirt & dust from the panels, walls, cleaning of fixtures (for one bank)

1

-

-

... More
Painting of internal/external walls and roof by approved brand of oil based distemper

1

-

-

... More
Painting of door and window panels of control room by approved brand of paint

1

-

-

... More
Repairs & Renovation of 11 KV VCB, by way of replacement of a) Grid-spout assembly

1

-

-

... More
b) Replacement of damaged CTs of different ratio Testing the CT with the help of primary injection set fixing in Panel, fixing the secondary connection after assessing the load (complete job)

1

-

-

... More
c) Thorough checking of control wiring circuits, replacement of damaged wire if any, replacement of terminal plates, tripping circuits, close/ trip switch, ammeter switch, replacement of voltmeter & ammeter .

1

-

-

... More
d) Replacement of 11 KV damaged PT

1

-

-

... More
e) Replacement of blown fuses, checking the PT terminal with respect of 11 KV bus bar complete job.

1

-

-

... More
f) Replacement of Trip/Close coil

1

-

-

... More
g) Replacement of Trivector meter on 11/33/66 kV Panels

1

-

-

... More
Installation, testing and Commissioning , replacement of LT cabele

1

-

-

... More
11 KV Power Cables / 33 KV Power cables/66 KV Power cables a) Identification of damaged portion of cable, tracing of cable, remove cable from trench, carriage and laying of cable (complete job) including cleaning of cable trenches.

1

-

-

... More
b) Replacement of damaged cable of sizes

1

-

-

... More
Replacement of termination kits of different sizes, connecting the cable with panel and outgoing structures after crimping of lugs fixing with nuts and bolts, checking of earth point, connecting the earthing point of cable with existing earthing system a) 11 KV Indoor Termination Kit (1-Phase/ 3 phase)

1

-

-

... More
b) 11 KV Outdoor Termination Kit (1-Phase/ 3 phase)

1

-

-

... More
c) 33 KV Indoor Termination Kit (Single Phase)

1

-

-

... More
d) 33 KV Outdoor Termination Kit (Three Phase)

1

-

-

... More
e) 33 KV Indoor Termination Kit (Three Phase)

1

-

-

... More
f) 33 KV Outdoor Termination Kit (Single Phase)

1

-

-

... More
g) 66 KV Indoor Termination Kit (Single Phase)

1

-

-

... More
h) 66 KV Outdoor Termination Kit (Single Phase)

1

-

-

... More
Improvement of earthing system in control room by way of replacement of earthing risers from earthing point to panel / checking of all welding points/ re-welding of lose connection, laying of fresh / additional earth-mat strip to improve the existing earthing system (Complete one Panel set)

1

-

-

... More
Checking of IR values

1

-

-

... More
De-watering of receiving station to avoid water logging.

1

-

-

... More
Repairing of electrical circuits for improvement of control room immunination, power points etc (Complete Job)

1

-

-

... More
Installation, Testing, commissiing for replacement of Aux. Transformer at receiving station

1

-

-

... More
On site repairing of aux transformer for missing phase, LT strip, LT bush rod, LT bush cup, HT bush rod etc (Complete job)

1

-

-

... More
Transport charges for carriage of T&P, men & material on urgent basis during power breakdown and restoration of system. (auto carrier) aditional 1km @ 90/per km

1

-

-

... More
Replacement of out door yard lights including wiring system and fixing of lamps on fixtures.

1

-

-

... More
Marking of equipment's, sign boards by way of painting/fixing of PVC plates for demarcation of different equipment to avoid mishandling.

1

-

-

... More
Replacement/repair/fixing of ceiling fans at Receiving station.

1

-

-

... More
Replacement/repair/fixing of cooling fans on radiators of power transformer to avoid heating.

1

-

-

... More
Flash in 66KV,33 KV & 11 KV Panels due to overloading moisture, Cleaning of carbonized panel by petrol / cotton cloth, replacement of damaged / worn-out lugs, post insulator, Bakelite sheet, arcing chamber panel heaters etc.

1

-

-

... More
Repair of plaster of thickness 12 mm to 20 mm in patches of areas 2.5 sqm meters and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete incl. disposal of rubbish to the dumping ground within 50 M lead a) with Cement mortar 1:4 (1 cement : 4 fine / coarse sand)

1

-

-

... More
Cutting of large tree branches falling over 66/33 lines and coming into the corridor to avoid damages/ faults/conductor snapping.

1

-

-

... More
Cleaning of cable duct, removing of duct covers and placing back after cleaning the duct including disposal of rubbish up to 50 Mtr lead

1

-

-

... More
Replacing sand store slabs in roofing, laid incement mortar 1:4 (1 cement : 4 coarse sand) including necessary repairs and cement painting with same mortar complete, including disposal of rubbish to dumping ground within 50 Meters of lead

1

-

-

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chow khats, holdfast etc. Complete and stacking with 50 Mtr lead

1

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel T-sections, joints mitred and welded, including fixing of necessary but hinges and screws and applying a priming coat of approved steel primer (CC 1:3:6)

1

-

-

... More
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 Mtr

1

-

-

... More
Cement concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 graded Stone aggregate) 62 mm thick

1

-

-

... More
Roof top treatment to prevent water leakage of control room

1

-

-

... More
Repairing of receiving station mesh fencing / Chain link mesh fencing height upto 8ft

1

-

-

... More
Watering of earth pits

1

-

-

... More
Cleaning of ACDC,DBDC Board, RTCC, Charger, Battery Bank, Solar batteries, other alike small equipments (complete Job)

1

-

-

... More
Cleaning of 66/33 kV CRP using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making 66/33 kV CRP Vermic Proof.

1

-

-

... More
Cleaning of 11 kV Panel using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making it Vermic Proof to avoid rodent faults.

1

-

-

... More
Erection of Channel cross arm of size 100X50X 6mm ,10 feet long and above including fixing of MS flat iron clamps with required size of bolts including punching of bolts complete

1

-

-

... More
Erection of Channel cross arm of size 100X50X 6mm up to 09 feet long including fixing of ms flat clamps with required size of bolts including punching of bolts complete

1

-

-

... More
Erection of Angle Iron Braces of size 65X65X6 mm ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type above up to 14' long complete

1

-

-

... More
Erection of Angle Iron Braces of size 65X65X6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type 6' and above upto 10' long complete

1

-

-

... More
Erection of Angle Iron belts of size 50X50X 6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type upto 10' long

1

-

-

... More
Erection of Angle Iron of size 65X65X6 mm fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in crossection type above 11' long complete for guardnetting.

1

-

-

... More
Flat iron ties 50x6 mm size 1 feet long along with fixing with cross arms

1

-

-

... More
Erection of 66 KV Disc insulator (polymer type ) with tension fittings including punching of locking pins complete

1

-

-

... More
Erection of 33 KV Disc insulator (polymer type ) with tension fittings including punching of locking pins complete

1

-

-

... More
Erection of 66 KV Pin insulator with pins 3 No. on top of cross arm including fixing of MS Flat Ties to rest it on , punching of base bolt /locking pin complete

1

-

-

... More
Erection of 33 KV Pin insulator with pins 3 No. on top of cross arm including fixing of MS Flat Ties to rest it on , punching of base bolt /locking pin complete

1

-

-

... More
Erection of Guy rod including digging of pit , Disposal of excavated soil ,refilling of excavated pits in layers of stone boulders and fine soil including fixing , adjusting properly Turn Buckle, Anchor Plate and staining screw complete

1

-

-

... More
Carriage at site , un-bundling , Laying and stringing of ACSR DOG Conductor including making of small bundles of conductor as per site requirement, cutting in required span lengths complete (AS PER REC STANDARD)

1

-

-

... More
Erection of anti climbing Devices at ST pole along with fixing /cutting /bending of Barbed wire, fixing with clamps

1

-

-

... More
Erection of Danger plates

1

-

-

... More
Route /temp path clearance by way of cleaning bushes and vegetation & making temp. path cutting & filling for carriage of line material ( 400 mx1mx0.2m)= 80 cum

1

-

-

... More
Sorting of material

1

-

-

... More
Route clearance for corridor of 5 m

1

-

-

... More
Installation, testing and Commissioning of 11kV Panel Board with VCB Incomer(one no.)

1

-

-

... More
Installation, testing and Commissioning of 11kV Panel Board with VCB outgoing(one no.)

1

-

-

... More
Setting of stubs with templates after positioning and leveling of templates excluding cost of foundations

1

-

-

... More
Handling and Fabrication of Material in Divisional Store, Fabrication of Angle iron braces/belts /guard netting angles ,fencing posts etc from angle iron of sizes

1

-

-

... More
Fabrication of guy rods complete including turn buckle, staining screw, anchor plate, thereading of guys and staining screw

1

-

-

... More
Fabrication of channel cross arms of sorts from MS channel of sizes , Making holes as per requirement,Punching of members and numbering on each member,Grinding of sharp edges and uneven surface of memebers and painting of members with red oxide paint.

1

-

-

... More
Fabrication of ties, clamps from MS flat ( suitable for 9 mts, 11mts, 13mts & 16 mts poles)

1

-

-

... More
Fabrication of earthing plates , cable duct covers from MS plate as per REC drawings

1

-

-

... More
Fabrication of earthing spikes from MS Tor steel of sorts as per REC drawings

1

-

-

... More
Fabrication of ST poles by way of drilling of extra holes

1

-

-

... More
Fabrication of foundation bolts from MS Tor steel of sorts including threading as per REC drawings

1

-

-

... More
Fabrication of earthing pipe from GI pipe and welding of earthing plate as per REC drawings

1

-

-

... More
Fabrication of column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures as per REC drawings

1

-

-

... More
Shifting of channel/Angle /Flat iron at and average distance of 50mtr from unloading site to site of stacking and stacked properly.

1

-

-

... More
Shifting of channel/Angle /Flat iron/fabricated material at and average distance of 50mtr for making space for other store material and its stacking .

1

-

-

... More
Unloading of PCC Poles 9/8 mts .

1

-

-

... More
Unloading of PCC Poles 11 mts .

1

-

-

... More
Unloading of PCC Poles 13 mts .

1

-

-

... More
Dragging/shifting of PCC/ST Pole at and average istance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking

1

-

-

... More
Shifting of Old/New ACSR Conductor at and average distance of 50mtr for unloading site to site of stacking and stacked properlyand also for making space for other store material and its stacking ..

1

-

-

... More
Unloading of 11KV VCB Panels (1+3)

1

-

-

... More
Unloading of 11KV VCB Panels (1+4) .

1

-

-

... More
Unloading of 11KV VCB Panels (1+5) .

1

-

-

... More
Unloading of 11KV VCB Panels OK/Damaged (1No) .

1

-

-

... More
Unloading ofAC Board/DC Board/Battery bank/ Battery charger

1

-

-

... More
Unloading of 33/ 66 KV VCB /C&R Panel .

1

-

-

... More
Shifting/ dragging of 11/33/66kv panel at an average distance of 50mtr for making space for other store material and its stacking also for making space for other store material and its stacking .

1

-

-

... More
Unloading of XLPE Cable 120/185 mm² .

1

-

-

... More
Unloading of XLPE Cable 240/300 mm² .

1

-

-

... More
Unloading of XLPE Cable 400/630 mm² .

1

-

-

... More
Shifting of XLPE Cable all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ...

1

-

-

... More
Unloading of 66/33/11 KV Cable kits of different sizes

1

-

-

... More
Shifting of 66/33/11 Cable kits of all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ...

1

-

-

... More
Unloading of Guy/GI wire/Barbed wire including carriage towards stacking site and stacked porperly.

1

-

-

... More
Unloading of 11KV New/damaged Distribution Transformer .

1

-

-

... More
Dragging of 11KV Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking

1

-

-

... More
Unloading of Transformer oil Barrels .

1

-

-

... More
Dragging of Transformer oil old/ new barrel at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking also for making space for other store material and its stacking ..

1

-

-

... More
Unloading of MS Angle, MS Channel, MS flate ,tar steel

1

-

-

... More
Unloading of hardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc .

1

-

-

... More
Shifting of hardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc at an average distance of 50mtr for making space for other store material and its stacking .

1

-

-

... More
Unloading of 33/11 KV Disc insulators .

1

-

-

... More
Unloading of 33 KV Disc fittings

1

-

-

... More
Shifting of 33/11 KV disc insulator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingalso for making space for other store material and its stacking .. .

1

-

-

... More
Unloading of 33/11 KV Pin insulators/Guy insulator /G.I Pin .

1

-

-

... More
Shifting of 33/11 KV pin insulator /guy/G.I Pins at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .

1

-

-

... More
Unloading of Cement .

1

-

-

... More
Shifting of cement/cement block at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. .

1

-

-

... More
Unloading of 33 KV CT/PT Unit .

1

-

-

... More
Shifting of 33 KV CT/PT at an average distance of 50mtr for making space for other store material and its stacking .

1

-

-

... More
Unloading of 11 KV CT/PT Unit including carriage towards stacking site and stacked porperly.

1

-

-

... More
Shifting of 11 KV CT/PT at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . .

1

-

-

... More
Unloading of 33 KV Isolators .

1

-

-

... More
Shifting of 33KV Isolators at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking and also for making space for other store material and its stacking . .

1

-

-

... More
Unloading of 33/66 KV LAs.

1

-

-

... More
Shifting of 33/66KV LAs at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .

1

-

-

... More
Unloading of 11 KV LAs/GO/HG/isolator .

1

-

-

... More
Shifting of 11 KV LAs/GO/HG/isolator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . .

1

-

-

... More
Unloading of PVC Cable /Control cable of different size including carriage towards stacking site and stacked porperly.

1

-

-

... More
Unloading of AL Paint /Red oxide paint/ Black paint including carriage towards stacking site and stacked porperly.

1

-

-

... More
Unloading of 66KV CT/PT/Isolator .

1

-

-

... More
Shifting of 66 KV CT/PT/Isolator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . .

1

-

-

... More
Unloading of T&P Items like Drilling machine,chainPully ,Pully lifting machine ,Hand drill machine,AL ladder,welding set,tool kit,crimping tool etc

1

-

-

... More
Dismantling of old 11KV Isolator including allied equipments

1

-

-

... More
Installation of 11KV Isolators

1

-

-

... More
Shifting of T&P /Testing / Safety equipments at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . .

1

-

-

... More
Unloading of Filter plant heavy duty

1

-

-

... More
Shifting of Filter plant at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .

1

-

-

... More
Loading of PCC Poles 9/8 mtr

1

-

-

... More
Loading of PCC Poles 11 mtr

1

-

-

... More
Loading of PCC Poles 13 mtr

1

-

-

... More
Loading of Cement

1

-

-

... More
Loading of 11 KV VCB 1+3 Panels

1

-

-

... More
Loading of 11 KV VCB 1+4 Panels

1

-

-

... More
Loading of 11 KV VCB 1+5 Panels

1

-

-

... More
Loading of 11 KV VCB 1 Panel OK/Damage

1

-

-

... More
Loading of AC Board/ DC Board/Battery charger /Battery bank

1

-

-

... More
Loading of 33KV VCB

1

-

-

... More
Loading of 33KV C&R Panels

1

-

-

... More
Loading of XLPE Cable 120/185 mm²

1

-

-

... More
Loading of XLPE Cable 240/300 mm²

1

-

-

... More
Loading of XLPE Cable 400/630 mm²

1

-

-

... More
Loading of Cable kits of different sizes

1

-

-

... More
Loading of Guy/GI wire/Barber wire

1

-

-

... More
Loading of 11 KV DistributionTransformer

1

-

-

... More
Loading of Transformer Oil barrels

1

-

-

... More
Loading of MS Angle iron braces, MS channel cross arms, Guy rod, Earthing spikes, MS Flate

1

-

-

... More
Loading of hardware items such as nuts and bolts, clamps of sorts,washers,welding rods,old sarees,chain link mesh,pipe

1

-

-

... More
Loading of 33 /11KV Disc insulator

1

-

-

... More
Loading of 33 KV Disc fitting

1

-

-

... More
Loading of 33/11 KV Pin insulator /Guy insulator /G.I Pin

1

-

-

... More
Loading of 33 KV isolator

1

-

-

... More
Loading of 33 KV LA

1

-

-

... More
Loading of 11KV Isolators

1

-

-

... More
Loading of PVC Cable /Control cable of different size including carriage from stacked site.

1

-

-

... More
Loading of AL Paint /Red oxide paint/ Black paint

1

-

-

... More
Loading of 66KV CT/PT/Isolator

1

-

-

... More
Loading of 66KV C&R Panel

1

-

-

... More
Loading of 66KV VCB Breaker SF6

1

-

-

... More
Loading of 66KV LA

1

-

-

... More
Loading of Filter plant heavy duty

1

-

-

... More
Carriage of Fabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etc towards stacking site and stacked properly

1

-

-

... More
Loading of Fabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etc including carriage from stacked site.

1

-

-

... More
Loading of 33 KV CT/PT units

1

-

-

... More
Loading of 11 KV CT/PT units

1

-

-

... More
Loading of T&P Items like Drilling machine,chainPully ,Pully lifting machine ,Hand drill machine,AL ladder,welding set,tool kit,crimping tool etc units

1

-

-

... More
Loading of Testing equipments like Meggar, Earth resitivity tester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc units

1

-

-

... More
Loading of Safety equipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etcunits

1

-

-

... More
Shifting of allied materials for making space for porper stacking of material

1

-

-

... More
Carriage of Fabrication material from fabrication site towards stacking site and proper stacking of material.

1

-

-

... More
Repair of store shed by way of replacement of damaged CGI sheets, repair of CGI sheets by way of welding, replacememt of hooks, nuts and bolts, tightening of nuts bolts and hooks and welding .

1

-

-

... More
Collection and carriage of T&P items to working site and back crriage of T&P after job

1

-

-

... More
Replacement of damaged glass panes

1

-

-

... More
Replacement of Damaged 66/33KV PI's

1

-

-

... More
Checking/Measuring/ Inspection/Meggering of XLPE Cable/Control cable by way of unreal and after work agian rereeling on drum

1

-

-

... More
Checking/Measuring/ Inspection of ACSR Conductor by way of unreal and after work agian re-reeling on drum

1

-

-

... More
Complete testing/inspection of Panels including relay testing , interconnection,charging polarity etc during issue/receipt/verification.

1

-

-

... More
Prototype Erection of Gantry /Beam/CT/PT/Isolator sturcture

1

-

-

... More
Plaster work in ratio 1:6 (Repair/New Work)

1

-

-

... More
Brick work in cement sand mix (Repair/New Work)

1

-

-

... More
Fixing of Taps (Repair/New Work)

1

-

-

... More
Fixing of urinal including allied fittings (Repair/New Work)

1

-

-

... More
Fixing/Repair of light point/Power Point, LED lights, etc including wiring (Repair/New Work)

1

-

-

... More
Fixing of yard light

1

-

-

... More
Fixing/Tightening of barbed fencing

1

-

-

... More
Fixing/Repair of main gate

1

-

-

... More
Repair of cable duct

1

-

-

... More
Installation of ceiling fan

1

-

-

... More
Fixing of window panes

1

-

-

... More
Charges for providing Highly Skilled Electrician/Fitter/Welder/Mason/Painter

1

-

-

... More
Charges for providing Highly Skilled Electrician/Fitter/Welder/Mason/Painter

1

-

-

... More
Charges for providing Skilled Electrician/Fitter/Welder/Mason/Painter

1

-

-

... More
Charges for providing Unskilled Labour

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.