Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date2 Jul 2024
Closing Date30 Jul 2024
Tender Amount₹ 13,81,000
Costs
EMD
₹ 28,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Ked 42 Of 2024 25 Dated 01 07 2024 For Creation Of 100 Kva Sub Station Alongwith Ht Line At Chainpura Jasrota In Respect Of Jpdcl Electric Sub Division Kathua Of Electric Division Kathua Under Jjm Scheme On Turnkey Basis
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDD_251824_1Tender No
KED 42 of 2024 25 Dated 01 07 2024Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
70mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
44
-
-
9 Mtr. Long pole (ST-410 SP 33)
2
-
-
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
3
-
-
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
300
-
-
Galvinized Nuts and Bolts.
8
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
3
-
-
LT Distribution box for 100 KVA DTR with MCCB for incommer & SFU's for outgoing ckt
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
Wedege connectors /PG clamps
6
-
-
Danger plate with clamps
1
-
-
GI Barbed wire for ani Clambing
15
-
-
3 Ph 4 Wire Trivector meter with CT
1
-
-
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole
2
-
-
Painting of poles Red oxide
2
-
-
Painting of poles Aluminum Paint
2
-
-
Erection of HT line on 9 Mtrs. PCC poles with ACSR Weasel Conductor at Chainpura (Jasrota) under JJM Scheme in respect JPDCL Electric Sub Division Kathua on Turnkey basis by way of supply erection/installation,testing Commissioning etc of following material.
-
-
-
9 Mtr. Long pole (ST-410 SP 33)
24
-
-
GI V cross-arm/Horizontal with top Bracket including clamp
336.96
-
-
GI Channel x-arm includingclaps and braces
188.4
-
-
30 mm² ACSR Weasel Conductor
3.81
-
-
PG Clamps for ACSR weasel conductor
15
-
-
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
72
-
-
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
15
-
-
Galvanized Nuts and Bolts
24
-
-
Danger Plates with Clamp
24
-
-
Anti Climbing Devices with clamps
24
-
-
Red oxcide Paint
24
-
-
Aluminium Paints
24
-
-
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole
24
-
-
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
24
-
-
Aluminium Jointing Sleeves
15
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
7
-
-
Erection of 11 KV Tapping point at Chainpura (Jasrota) under JJM Scheme in respect JPDCL Electric Sub Division Kathua on Turnkey basis by way of supply erection/installation,testing Commissioning etc of following material.
-
-
-
9 Mtr. Long Pole(ST-410 SP-33 )
2
-
-
GI V cross-arm/Horizontal with top Bracket including clamp
34
-
-
GI Channel/ angle iron including Clamps
52
-
-
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
1
-
-
30 mm² ACSR Weasel Conductor
15
-
-
PG Clamps for 30mm2 ACSR conductor
3
-
-
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
6
-
-
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
3
-
-
Galvanized Nuts and Bolts
1
-
-
Danger Plates with Clamps
2
-
-
Anti-Climbing Device with Clamps
2
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
3
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
Cement bottoming 1:2:4 Mix as per REC Standars
2
-
-
Aluminium Paint
2
-
-
Red oxide paint
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements