Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Nov 2024
Closing Date24 Dec 2024
Tender Amount₹ 1,41,00,000
Costs
EMD
₹ 2,82,000Document Cost
₹ 1,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDD_266200_1Tender No
EE/TLMDA/11 OF 2024Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Fabrication, galvanisation and supply of stub legs with requisite cleats.
1.25
-
-
Fabrication, galvinisation and supply of anti climbing devices, Bird guard, Danger plates, phase plates, number plates , circuit plates and other allied accessories for 04 No. Tower ( Complete 04 sets for 04 No. Towers which are to be inserted)
4
-
-
Supply of earthing material for Towers to be inserted including all accessories ( For 04 No. Towers either Normal/Pipe earthing or as per the directions of Engineer Incharge Complete Job)
4
-
-
CONDUCTOR AND HARDWARE FITTINGS SUITABLE FOR 0.2 ACSR CONDUCTOR
-
-
-
200 mm² ACSR Conductor,(a) Alumunium=30/3 mm(b) Steel=7/3 mm Overall dia. 21mm.Approximate Wt 976Kg/Km Ultimate breaking Load=89.67 KN;including 1.5%sag and jumpering
6
-
-
Supply of 4R stock bridge type vibration damper ( 02 No./Phase/Tower) suitable for ACSR Panther (of 30/7/3.18mm designation) of approved design. The clamps and keeper of the vibration damper shall be made to Al alloy so designed as to prevent any damage to or chafting of the conductor, during erection or continued operation. Clamping bolts, washers should of mild steel/HDG provided with self locking Nuts designed to prevent corrosion of the threads. All ferrous parts including the messenger cable shall be hot dip galvanized (IS 2633). The ends of messenger cable shall be effectively sealed to prevent corrosion. Spring washers should be electro galvanized dampers mass should be of cast Iron HDG conforming to IS 9708 of 1980
48
-
-
Supply of Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280 mm dia. Creepage total 430 mm and 260 mm protected.
664
-
-
Supply of Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255 mm dia. Creepage total 430 mm and 260 mm protected.
268
-
-
Supply of Single Suspension Fittings for panther shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 16 mm.
36
-
-
Supply of Single Tension Fittings for panther shall have minimum failing load of 100% ultimate strength of bundle conductor with comprehensive type tension clamps having slipping strength 95% of ultimate strength of conductor. The ball and socket designation must be 16 mm.
36
-
-
Supply of Compression type repair sleeve suitable for ACSR Panther conductor of 30/7/3.18mm designation with body and keeper made of Aluminum Alloy for providing reinforcement of conductor with broken/damaged aluminum strands. Repair sleeve should conform to IS: 2121/1981 (with latest amendments up to date) and should present a smooth surface after compression.
16
-
-
Supply of Mid span compression joint for ACSR Panther (of 30/7/3.18mm designation) suitable for making joints in the conductor so designed that on installation no air space is left within the finished joint. The Al sleeve used should be of extruded Al tube of purity not less than 95% while as steel sleeve should of high strength steel.
27
-
-
Double tension hardware fitting for Panther conductor conforming to IS 2486 (Part-I) ammended upto date and having tension clamp of Al alloy grade-A6(IS: 617-1975), ferrous parts hot dip galvanized (IS: 2633 1986 ) suitable for 20mm B&S 120KN Disc insulators., UTS of hardware = 9000Kg
UTS / Slip strength of Clamp = 95% UTS of conductor = 8550 kg
18
-
-
Double suspension hardware fitting for Panther conductor conforming to IS 2486 (Part-I) ammended upto date) and having suspension clamp of Al alloy grade-A6(IS: 617-1975), ferrous parts hot dip galvanized (IS: 2633 1986 ) suitable for 16mm B&S 70KN Disc insulators., UTS of hardware =7000Kg
12
-
-
OPGW,Dual window single-Mode with Mode field diameter 8.6-9.5 µm ,cladding diameter 125 µm ±1 µm,1.5% wastage included
0.2
-
-
OPGW ACCESSORIES
-
-
-
A) Tension Clamp set including Anchor Shackle, Twisted Shackle, Suspension Clamp, Inner and outer Armoured Protection Rods
4
-
-
B) MidSpan joint
4
-
-
C) Vibration Dampers
8
-
-
(B) LOADING/UNLOADING OF MATERIAL,MECHANICAL TRANSPORTATION,MANUAL CARRIAGE, HANDLING, STORAGE, PRESERVATION, WATCH AND WARD , ERECTION / INSTALLATION, TESTING AND COMMISSIONING OF ALL THE MATERIAL REQUIRED FOR JOB OF INSERTION OF 04 NO TOWERS AT VARIOUS LOCATIONS INCLUDING DISMANTLING OF EXISTING 0.2 ACSR OLD CONDUCTOR AND RESTRINGING OF THE SAME, ALSO LAYING AND STRINGING OF 0.2 ACSR NEW CONDUCTOR AFTER INSERTION OF TOWER ETC.
-
-
-
Erection of Lattice Type Hot Dip Galvanized Steel Towers ( Plain terrain/semi hilly terrain) including packing and forwarding, transportation charges etc for 132 KV D/C Transmission Line complete with all tower parts & Extensions including step bolts, tower nuts and bolts, hangers, D-shackles etc. complete in all respect as per scope & Technical specifications
31.2
-
-
Erection/fixing of anti climbing devices, Bird guards, Danger plates, phase plates, number plates, Circuit plates and other allied accessories for these 04 No. inserted towers.(Complete Job)
4
-
-
Placing/Fixing of earthing including excavation of earth for earthing for towers including all accessories ( For 04 No. Towers either Normal/Pipe earthing or as per the directions of Engineer Incharge) Complete Job.
4
-
-
Tag welding of towers 1st two stories/ sections including all the material required for the said Job ( Complete job)
4
-
-
DISMANTLING OF OLD PANTHER CONDUCTOR AND LAYING OF FRESH 0.2 ACSR PANTHER CONDUCTOR (06 KMS) & STRINGING OF OLD AND NEW PANTHER CONDUCTOR AT 04 (FOUR) TOWER INSERTION LOCATIONS OF DOUBLE CIRCUIT 132KV PATTAN-AMARGARH AND PATTAN-ZAINKOT TRANSMISSION LINES.
-
-
-
Dismantling/Lowering of existing conductor along with hardware fittings (From Plain terrain/semi hilly terrain) and placement of conductor on ground without damaging the trees and crops underneath including bundling/rolling , Loading/unloading, transportation( Manual and mechanical) upto Divisional Stores at Amargarh of 6km old panther conductor which is to be replaced with fresh 0.2 ACSR conductor etc ( Complete Job).
14.8
-
-
Laying of Fresh 0.2 ACSR conductor to string 1 KM+10% extra for uneven terrain( For Plain as well as semi hilly terrain) at various tower insertion locations or as per the directions of the Engineer Incharge ( Complete Job)
6
-
-
Stringing of panther conductor 1 Km + 1.5% for sag for 6 phase including errection of Disc insulator strings and errection of Hardware fittings( Suspension/Tension and Vibration dampers etc) and also repairing of conductor if required or as per directions of Engineer-incharge. (Complete Job)
14.8
-
-
Extra for laying / stringing of conductor through nallah P&T lines, LT/HT lines ( If applicable)
14.8
-
-
Making of Compression type repair sleeve joints suitable for ACSR Panther conductor.
14
-
-
Making of Mid span compression joint for ACSR Panther.
27
-
-
Erection of Jumpers at tension towers.
9
-
-
Dismantling/ Lowering of existing earthwire (if required) including laying of new OPGW earthwire (0.2 Kms) for plain and semi hilly terrains at various insertion locations or as per the directions of Engineer-incharge ( Complete Job)
1.6
-
-
Stringing of Earthwire 1 Km + 1.5% for sag including errection of Hardware fittings(Suspension/Tension and Vibration dampers etc) for plain as well as semi hilly terrains at various insertion locations or as per directions of Engineer Incharge.( Complete Job)
1.6
-
-
Anchoring of Towers including dismantling of arrangements or as per the directions of the Engineer Incharge.
8
-
-
Route Clerance/Branch Cutting of double circuit line with 25 Mtr wide corridor.
13300
-
-
(C) Civil Works including Design, Supply, Execution/Laying of Tower foundations.
-
-
-
Foundation work for 132 KV Tower structure foundation including Earthing of this tower structure etc. ( Complete Job)
-
-
-
Site clearance at tower foundation including removing of vegetation , thorns, shrubs , trees, Jungle clearance.
1600
-
-
Surveying the line portions for identification of exact position of towers for insertion, Detailed Survey including Check survey, GPS Positioning, Measurement of Land for towers, Tower spotting , tower profiling and scheduling , pit marking including checking of alignments, framing of drawings, framing and approval of tower schedules, fixing of stone burjees and other allied design works for such 04 No. Tower ( Complete Job for four no towers to be inserted at various locations) Complete Job.
1
-
-
Carrying out of Geological Investigation of earth ( Soil Bearing Capacity) and recording of earth resistivity including framing of reports and vetting of the same from the reputed Government /Govt. Accredited Houses etc Complete Job or as per the directions of Engineer Incharge.
4
-
-
Excavation in 30% dense/hard/muddy soil and 70% in diintegrated or soft rock for any section including all labour, POL, hire charges of equipments, dewatering of pits and T&Ps etc. including sheeting & shoring, dewatering, lifting, handling and stock piling of excavated materials, back filling with excavated or borrowed earth once foundation is laid and disposal of surplus excavated earth as directed for all leads & lifts complete as per specification, construction drawings and direction of Engineer-in-charge.
496.91
-
-
Stub setting for tower foundations using proper template as per approved design including its transportation and carriage.
4
-
-
Fixing and placing in position of stub legs including alignment of tower foundation.
4
-
-
High yield strength cold deformed steel reinforcement bars ( TMT Bars of Grade Fe-500 D or More)conforming to IS: 1786 for R.C.C. or any other work including the cost of all materials, carriage (Manual & Mechanical), binding wire, labour, hire charges of equipments and T&P, bending, binding, placing and tieing in position, POL etc. complete job as per specification, construction drawings and direction of Engineer-in-charges.
3.51
-
-
Plain cement concrete of specified grade and strength conforming to IS: 456 placed as sub-base under structural concrete or as shown in approved construction drawings at all levels including cost of all materials, labour, hire charges of equipments and T&P, POL, centering & Form work/shuttering etc complete for handling, transportation, batching, mixing, placing, vibrating, compacting, leveling, curing etc. as per specification, construction drawings and direction of Engineer-in-charge.
-
-
-
Concrete of M-10 grade having cube strength of 10 N / mm2 with 20/40 mm nominal size coarse aggregate for tower foundation.
8.15
-
-
Structural cement concrete ( plain/ reinforced) of specified 28 days strength (nominal size of coarse aggregate 20 mm) at all levels, including cost of all materials, labour, hire charges of equipments and T&P, POL, Centering and shuttering/form work, curing, etc complete for handling, transportation, batching, mixing, placing, vibrating, and rendering, cleaning and finishing /Coping the exposed over ground surfaces with cement mortar 1:3 (1 cement : 3 sand) to give smooth and even surface ( as applicable) but excluding the cost of reinforcement complete as per specification, construction drawings and direction of Engineer-in-charge.
-
-
-
Concrete of M-25 grade having cube strength of 25 N/mm2 with 20 mm nominal size coarse aggregate for Tower foundation
49.07
-
-
Benching of uneven foundation area including disposal of surplus soil.All kinds of soil
211
-
-
(D) DESIGN, MANUFACTURE, SUPPLY, PACKAGING, HANDLING, STORAGE, PRESERVATION, WATCH AND WARD , ERECTION / INSTALLATION, TESTING AND COMMISSIONING OF 132 KV SF6 BREAKER FOR 132 KV PATTAN-ZAINKOT TRANSMISSION LINE CIRCUIT 2ND AT 132/33 KV GSS PATTA INCLUDING DISMANTLING OF OLD BREAKER, THEIR TRANSPORTATION AND SAFE STOCKING OR AS PER THE DIRECTIONS OF ENGINEER INCHARGE.
-
-
-
Supply, Installation, testing and commissioninig of 3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries ,marshalling boxes/Kiosks and any sort of modifications to the existing breaker foundations etc, (145KV, 1250 Amps of 3 phase, 50 c/s and 31.5KA for 1 second) Complete job.
1
-
-
Dismantling of the old 132 KV Breaker ( 01 No) spared after erection and commissioning of new breaker, its safe handling, dragging, loading at site, its transportation, unloading either at divisional / site store including any sort of modifications to the existing breaker foundations (01 No) if required including Providing/fixing of 100X50X50x6mm MS Channels and M20 grade RCC wherever needed or as per the instructions of Engineer incharge.( Complete Job)
1
-
-
G) Supply, Fabrication, transportation, measurement and fixing of galvanised missing members of various sizes at various tower locations of 132kV Pattan-Amargarh and Pattan-Zainkot transmission lines.
-
-
-
Providing/Supply, fabricating,transportation, Loading,unloading, measurement and fixing/erection of galvanised iron missing members of various sizes at various tower locations of 132kV Pattan-Amargarh and Pattan-Zainkot transmission lines ( the missing members are to be fixed at different locations including fabricating, loading,unloading ,carriage and measurements at site). COMPLETE JOB
8
-
-
Providing/Supply, transportation,carriage and fixing of Hot Dip galvanised Nuts and Bolts of various sizes at various tower locations of 132kV Pattan-Amargarh and Pattan-Zainkot transmission lines including welding of these nuts and bolts after fixing missing members ( The Nuts & Bolts are to be fixed at different locations including its loading,unloading ,carriage). COMPLETE JOB
0.4
-
-
SUPPLY OF MANDATORY SPARES:- Supply, Packaging, galvanising & Forwarding, Transportation (Mechanical as well as Manual), Delivery at the Divisional Stores or site stores or as per the Directions of Engineer Incharge.
-
-
-
200 mm² ACSR Conductor,(a) Alumunium=30/3 mm(b) Steel=7/3 mm Overall dia. 21mm.Approximate Wt 976Kg/Km Ultimate breaking Load=89.67 KN;including 1.5%sag and jumpering
0.5
-
-
Supply of Mid span compression joint for ACSR Panther (of 30/7/3.18mm designation) suitable for making joints in the conductor so designed that on installation no air space is left within the finished joint. The Al sleeve used should be of extruded Al tube of purity not less than 95% while as steel sleeve should of high strength steel.
6
-
-
Supply of Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255 mm dia. Creepage total 430 mm and 260 mm protected.
15
-
-
Supply of Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280 mm dia. Creepage total 430 mm and 260 mm protected.
25
-
-
Supply of Single Suspension Fittings for panther shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 16 mm.
3
-
-
Supply of Single Tension Fittings for panther shall have minimum failing load of 100% ultimate strength of bundle conductor with comprehensive type tension clamps having slipping strength 95% of ultimate strength of conductor. The ball and socket designation must be 16 mm.
6
-
-
Double tension hardware fitting for Panther conductor conforming to IS 2486 (Part-I) ammended upto date and having tension clamp of Al alloy grade-A6(IS: 617-1975), ferrous parts hot dip galvanized (IS: 2633 1986 ) suitable for 20mm B&S 120KN Disc insulators., UTS of hardware = 9000Kg, UTS / Slip strength of Clamp = 95% UTS of conductor = 8550 kg
2
-
-
Double suspension hardware fitting for Panther conductor conforming to IS 2486 (Part-I) ammended upto date) and having suspension clamp of Al alloy grade-A6(IS: 617-1975), ferrous parts hot dip galvanized (IS: 2633 1986 ) suitable for 16mm B&S 70KN Disc insulators., UTS of hardware =7000Kg
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%