Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Energy, Oil and Gas
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Oct 2024
Closing Date2 Dec 2024
Tender Amount₹ 29,86,00,000
Costs
EMD
₹ 59,72,000Document Cost
₹ 25,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDD_260877_1Tender No
CE/P/KPDCL/RDSS/03 of 2024-25Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ)
3
-
-
33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
3
-
-
33KV Isolator with Earthing Blade (36KV, 800A, Outdoor, 3 Poles,25KA)
16
-
-
33 kV Isolator without Earthing Blade (36KV,800A,Outdoor,3 poles,25 KA)
2
-
-
33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ)
6
-
-
33 kV 10kN Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m
6
-
-
33 KV C&R Panel along with O/C,E/F, REF and differrential relay (IEC61850) Mimic diagram, voltmeter, ammeter,Annunciation window with annunciation relay, 3-phase Tri-Vector Meter-5amp DLMS Compliant with RS-485V Port
3
-
-
a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant.
b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply .
1
-
-
Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
1
-
-
Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other
accessories
1
-
-
12 kV Capacitor Bank with VCB Panel with complete arrangement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories (2.4 M VAR).
1
-
-
750 mm Cable Trench
40
-
-
500 MM Cable Trench
15
-
-
Control Room Building (12m x10m)
120
-
-
Truss for Control Room Building 1.5xPlinth area (P/F of Steel Truss including provision of Colour Coated Roofing
180
-
-
Shift Quarters for JE and SBA (10m x9m)
90
-
-
Development of land by removing weeds, wild grass and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas and road sides and development of roads along with surface drains
1
-
-
Compound walling of identified land by way of Mass Concrete in Foundations and 228 mm Brick Wall of 2 M height
128
-
-
Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height
50
-
-
HDPE Pipe Outer Dia 160 mm Inner Dia 148 mm for laying of 11kV XLPE Cable from Power Transformer to Control Room including excavation and laying
25
-
-
33/11 kV Power Transformer Foundation (3mx2.5mx1.5m)
1
-
-
33 kV Equipment Foundation & Gantry foundation
1
-
-
33 kV Yard Concreting (24mx14mx0.1m)
33.6
-
-
200 mm² ACSR Conductor Panther
200
-
-
Galvanised Steel Structures (Pipe Structure)
13.5
-
-
Galvanized Nuts and Bolts
5614.6
-
-
Foundation for VCB
1
-
-
12 Core 2.5 Sqmm Control Cable Copper Armoured 1.1 KV Grade, ISI, FRLS
300
-
-
6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
420
-
-
4.5 Core 2.5 Sqmm Control Cable Copper Armoured 1.1 KV Grade, ISI, FRLS
300
-
-
4 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
300
-
-
2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
360
-
-
Lugs, Ferrules etc. (for PTR & Line Bays)
1
-
-
T Clamps
27
-
-
Single Tension Fittings 6 bolt
9
-
-
Earth wire 7/4.00 mm sq.
58
-
-
GI flat for earthing 50x6 mm
125
-
-
Telecommunication facilities
1
-
-
Rubber Mat 1mx2m 19mm thick
4
-
-
Fire Extingiusher Co₂ Type of 4.5 kg capacity for control room
6
-
-
3 Sand Bucket Fire Extingiusher
1
-
-
Helmet
4
-
-
Rubber Gloves for 33 kV level
2
-
-
Rubber Gloves for 11kV level
2
-
-
Safety Belt
4
-
-
Safety Shoes (Ankle Boot)
4
-
-
Earthing rod 5 mtr long with 25 sqmm cable 12 mtr
3
-
-
HV Detectors all voltages
1
-
-
Alumunium Ladder 2*20 ' , 3 mm Thick (extendable with rope and pully arrangement)
1
-
-
Earthing Mat (GI Flat 50mm x8 mm)
2486
-
-
Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip 50x6mm
38
-
-
Borewell of 5 " dia outer pipe and 1" dia for motor with submersible pump (1.5 HP) approx.60 mtr
1
-
-
Yard Lighting by way of Providing 12 Mtr motorised High Mast with 4 No.s of 200 W LED flood lights on each High Mast complete with earthing , and foundations
2
-
-
11 kV VCB Panel Board (12 kV, 1250A, 25 kA, indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port For 6.3 MVA (1+4)
1
-
-
11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets)
5
-
-
11 kV 3- Core XLPE 400 mm² armoured, FRLS
40
-
-
11 kV 3-Core XLPE 120 mm² armoured, FRLS
180
-
-
11kV Indoor Heat Shrinkable Cable Termination Kits incoming Cable (Single/Three core)
1
-
-
11kV Outdoor Heat Shrinkable Cable Termination Kits incoming Cable (Single/Three core)
1
-
-
11kV Indoor Heat Shrinkable Cable Termination Kits Outgoing Cable
4
-
-
11 kV Outdoor Heat Shrinkable Cable Termination Kits Outgoing Cable
4
-
-
11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch.
3
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp
1
-
-
100 kVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound)
1
-
-
120 mm² XLPE LT Cable 4 Core, armoured, FRLS
15
-
-
Earthing of 100 KVA SubStation--Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
1
-
-
MCCB ‐ 200 Amps , 36KA, 4P
1
-
-
9 M long Steel Tubular poles with welded steel base plate 300x300x8mm of Designation 410 SP 33 as per IS 2713 amended upto date along with 75x40x5mm GI channel for earthing arrangement & Pole marking
4400
-
-
11 M long Steel Tubular poles with welded steel base plate 300x300x8mm of Designation 410 SP -56 as per IS 2713 amended upto date along with 75x40x5mm GI channel for earthing arrangement & Pole marking
468
-
-
100 mm² ACSR Conductor
80.34
-
-
50 mm² ACSR Conductor
481.73
-
-
PG Clamps for 100 mm² ACSR Conductor
160
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
2418
-
-
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
486
-
-
Guard Netting of single span with GI Channel X-arm (40 KG)including clamps & brace, galvanized Nuts & bolts (3KG), GI Wire 6 SWG &8SWG (27 KG) and Eye Bolts (4 Nos)as per approved Drawing and specifications
10
-
-
PG Clamps for 50 mm² ACSR Conductor
1871
-
-
GI V cross-arm with top Bracket including clamp & GI Channel X-arm including clamps and braces
129814.5
-
-
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11225
-
-
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
2339
-
-
Danger Plates with Clamps
4859
-
-
Anti-Climbing Device with Clamps
4053
-
-
Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3 mm
4877
-
-
Red Oxide
4859
-
-
Aluminium Paint
4859
-
-
Cement Bottoming 1:2:4 mix as per REC standards including muffing, form work and allied job 0.5 cum/Pole for 9.0 mtr and 0.6 cum/Pole for 11.0 mtr (To be quoted in erection only)
4868
-
-
Aluminium Jointing Sleeves
468
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 ) mm, nut- bolts, 2 Nos turn-buckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete
300
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 )mm, nut-bolts, 2 Nos turn- buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
624
-
-
33 kV, Single core 185 mm2 Aluminium,round wire Armoured XLPE Cable,FRLS (One spare cable) (incliding 76mm I/D & 90mm O/D of HDPE Pipe : 32 mtr per CKM)
24.72
-
-
Straight Through Joints for cables for 33 kV, Single core 185 mm2
96
-
-
Route Marker
60
-
-
Warning Tap
6
-
-
Cable Termination Kits sutiable for 185 Sqmm(Outdoor)
48
-
-
Excavation in any type of soil including hard laterite soil
3510
-
-
Back filling of available excavated earth
3105
-
-
Sand for cushioning of HT underground cables
405
-
-
Mechanical transport 30kms of sand
405
-
-
Head load 100 mtrs of sand
405
-
-
GI Pipe 150 mm dia with required no of collars for road crossing including termination points
660
-
-
RCC protective cover of size 300 mm (width) x 300mm (Length) x 60 mm (Thickness) for underground cables
5400
-
-
Brick Masonary Chamber (900x900x1050)mm with RCC top slab, Cast Iron cover in CI Frame (38Kg) after 500 mtrs
12
-
-
Reinstatement of roads (100 m x .7 m x 0.2 m thick) = 14 cums
84
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%