Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Survey Works
Eprocure
Opening Date16 Sep 2020
Closing Date6 Oct 2020
Tender Amount₹ 33,62,000
Costs
EMD
₹ 67,240Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Survey Design Transportation Carriage Supply Installation Testing And Commissioning Of 2x100 Kva Sub Station (stages 0,1) Along With 11kv Ht Tapline On 9 Mtr St Poles With Acsr Weasel Conductor At Wss Batora In District Reasi Under Languish
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_PDD_104480_1Bid Award Id
ViewTender No
eNIT NO. 16 OF 2020-21 DATED 14.09.2020Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
GI Channel X Arm including clamps and braces
480
-
-
30sqmm ACSR Conductor
9.27
-
-
PG Clamp for 30sqmm ACSR Conductor
36
-
-
11kV Polymeric Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
171
-
-
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lighting Impulse 75kV positive and 80kV negative, creepage distance 320mm
36
-
-
Galvanised Nuts & Bolts
63
-
-
Danger Plates with clamps
63
-
-
Anti Climbing Device with Clamps
63
-
-
Earthing Complete by GI Pipe 40mm or GI Rod 20 mm 2.5 Meter long through GI Strip
63
-
-
Red Oxide
63
-
-
Aluminium Paint
63
-
-
Cement Bottoming 1:2:4 mix as per REC Standards .5CUM/Pole
63
-
-
Stone Pad (300mmX300mmX75mm)
63
-
-
Aluminium Jointing Sleeves
9
-
-
Link Set
2
-
-
Galvanised Stay setwith 50x8mm stay clamp, Guy Insulator (2 Nos), Anchor Plate (200x200x6mm) nuts and Bolts, 2Nos Turn Buckles, 1.8 long, 16mm diameter solid GS Stay rod & 7/3.15mm dia GI Standard wire complete
15
-
-
Creation of 2x100 KVA Sub Station (Stages 0,1)
-
-
-
11/0.433kV, 100KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
2
-
-
Gapless Surge Arrestor, 9kV, 10kA, LA with polymer housing, Station type
2
-
-
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type
2
-
-
11kV Horn Gap Fuse set 3-phase, 200 Amp
2
-
-
185sqmm(2ckt)cable 1.1 kv grade. PVC insulated standard conductor FRLS Type
88
-
-
9 Meter Long ST-410 SP33
4
-
-
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lighting Impulse 75kV positive and 80kV negative, creepage distance 320mm
6
-
-
GI Galvanised Channel/angle/flat of size including clamps
600
-
-
Galvanised Nuts and Bolts
16
-
-
Earthing of substation --Excavation of dia earth pit of 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. (Complete Job)
6
-
-
11kV Polymeric Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
6
-
-
LT Distribution Box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing Circuits
2
-
-
Galvanised Stay setwith 50x8mm stay clamp, Guy Insulator (2 Nos), Anchor Plate (200x200x6mm) nuts and Bolts, 2Nos Turn Buckles, 1.8 long, 16mm diameter solid GS Stay rod & 7/3.15mm dia GI Standard wire complete
4
-
-
Wedge Connectors/PG Clamps
12
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for anti climbing
30
-
-
3Ø, 4-Wire Trivector Meter with CT-PT Combo Unit
2
-
-
Cement Bottoming 1:2:4 mix as per REC Standards .5CUM/Pole
4
-
-
Painting of Poles Red Oxide
4
-
-
Painting of Poles Aluminium Paint
4
-
-
Sundary Items
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements