Power Development Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Power Development Department - PDD Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date22 Nov 2024
Closing Date14 Dec 2024
Tender Amount₹ 2,75,44,000 
Notes
Download

Costs

Summary

Providing Of 33 Kv Power Supply

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) alongwith clamps for Panther conductor

1

-

-

... More
33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) alongwith clamps for Panther conductor

1

-

-

... More
33 kV Current transformer(33 kV,1 phase , 400-200/5-5-5 A, 5P, 0.2s, PS,outdoor)(1 No per phase)

3

-

-

... More
30 kV Lightening Arrestors (30kV,10 KA,Station Class ,ZnO, Polymer, Discharge class 3) gap less

3

-

-

... More
33 kV Voltage Transformer ( 33kV, 1- Phase, Multi Ratio , 0.5-3P , Outdoor) ( 1 No. per Phase)

3

-

-

... More
33 kV Post Insulator polymer 36 kV Impulse ,Creepage distance 1224 m.

3

-

-

... More
Galvanised Nuts &Bolts

0.15

-

-

... More
Galvanised steel structure

3.5

-

-

... More
12 Core 2.5 mm2 Control Cable copper Armoured,1.1 kV Grade,ISI, FRLS.

60

-

-

... More
4 Core 2.5 mm2 Control Cable copper Armoured,1.1 kV Grade,ISI, FRLS.

300

-

-

... More
2 Core 2.5 mm2 Control Cable copper Armoured,1.1 kV Grade,ISI, FRLS.

60

-

-

... More
Lugs,Ferrules etc

1

-

-

... More
T Clamps panther

15

-

-

... More
Single tension fittings

30

-

-

... More
Polymeric composite Disc Insulator 36 kV ,Lightening Impulse 170 kV positive and 180kV negative ,creepage distance 900 mm,min failing load 70kN

5

-

-

... More
Earth wire7/4.00 mm sq

5

-

-

... More
GI flat for earthing 50X6mm

6

-

-

... More
Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height

68

-

-

... More
33 kV Equipment Foundation & Gantry foundation (for additional equipments )

2

-

-

... More
Earthing Mat (GI Flat 50x8)

1

-

-

... More
Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip.

32

-

-

... More
33 kV Yard Concreting/Metalling

1

-

-

... More
Yard Lighting

1

-

-

... More
33 kV Electrical safety gloves gloves (meet or exceed ASTM D120 and IEC EN60903 Standards)

3

-

-

... More
11 kV Electrical safety gloves gloves (meet or exceed ASTM D120 and IEC EN60903 Standards)

3

-

-

... More
Non-contact High Voltage Detector (Wrist Type) 1kV to 500KV , IP54 Protection Level

10

-

-

... More
FRP Telescopic Earth/Discharge rod for 11 to 33 kV system (Assemble Length:-20 feet)

2

-

-

... More
Electrical Insulating Rubber Matting IEC/BS EN 61111:2009

6

-

-

... More
33 KV BPCL LINE FROM BAJALTA R/STN TO BPCL SUB STATION

-

-

-

... More
13Mtr. Long POLE (ST-410 SP 69)

102

-

-

... More
G.I Steel of sorts (Channel 100x50x6 mm, Angle 65x65x6 mm & 50x50x6 mm, Flat 50x6 mm)

6800

-

-

... More
100 sqmm ACSR Conductor

15.45

-

-

... More
PG clamps for 100 sqmm ACSR conductor

60

-

-

... More
33 KV Polymeric composite Pin Insulator 36 KV,10 KN, Lighting Impulse 170 KV Positive and 180 KV Negative, creepage distance 900 mm

285

-

-

... More
33 KV Polymeric composite Disc Insulator 36 KV,min failing load 70 KN, Lighting Impulse 170 KV Positive and 180 KV Negative, creepage distance 900 mm

60

-

-

... More
Galvanized Nuts and Bolts

95

-

-

... More
Danger Plates with Clamps

95

-

-

... More
Anti -Climbing Device with Clamps

95

-

-

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.

95

-

-

... More
Red Oxide

95

-

-

... More
Aluminium Paint

95

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards ( 0.6 cum/pole) alongwith Stone pad (300 mm X 300 mm X 75 mm)

95

-

-

... More
Aluminium Jointing Sleeves

15

-

-

... More
Galvanised Stay Set with 50x8 mm Stay clamp,guy insulator (2Nos.),anchor plate (300x300x8 mm),nut-bolts,2 Nos turn-buckles,1.8m long,20 mm diameter solid GS Stay rod & 7/4.00 mm dia GI Stranded wire complete

25

-

-

... More
33 kV Isolator without earthing blade ( 36kV, 1250A) outdoor, 3-Pole, 25 kA

3

-

-

... More
Guard Netting (with GI wire 8 SWG, GI Channel X-arm including clamps and braces, Eye Bolts)

25

-

-

... More
Renewing the road surface ( damage caused during execution of work)

60

-

-

... More
THICKENING OF 4.5 KM ACSR CONDUCTOR FROM 100 SQ.MM(DOG) TO 200 SQ. MM (PANTHER) FOR BPCL LINE FROM SIDHRA GRID STATION TO BAJALTA R/STN

-

-

-

... More
11Mtr. Long POLE (ST-410 SP 56)

22

-

-

... More
GI V cross arm with top bracket including clamp

950

-

-

... More
GI Channel X-arm including clamps and braces

415

-

-

... More
200 sqmm ACSR Conductor

14

-

-

... More
PG clamps for 200 sqmm ACSR conductor

54

-

-

... More
33 KV Polymeric composite Pin Insulator 36 KV,10 KN, Lighting Impulse 170 KV Positive and 180 KV Negative, creepage distance 900 mm

99

-

-

... More
33 KV Polymeric composite Disc Insulator 36 KV,min failing load 70 KN, Lighting Impulse 170 KV Positive and 180 KV Negative, creepage distance 900 mm

54

-

-

... More
Galvanized Nuts and Bolts

135

-

-

... More
Danger Plates with Clamps

135

-

-

... More
Anti -Climbing Device with Clamps

135

-

-

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.

135

-

-

... More
Red Oxide

135

-

-

... More
Aluminium Paint

135

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards .6cum/pole

44

-

-

... More
Aluminium Jointing Sleeves

13.5

-

-

... More
Galvanised Stay Set with 50x8 mm Stay clamp,guy insulator (2Nos.),anchor plate (300x300x8 mm),nut-bolts,2 Nos turn-buckles,1.8m long,20 mm diameter solid GS Stay rod & 7/4.00 mm dia GI Stranded wire complete.

22.5

-

-

... More
33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) alongwith clamps for Panther conductor

2

-

-

... More
Guard Netting (with GI wire 8 SWG, GI Channel X-arm including clamps and braces, Eye Bolts)

24

-

-

... More
33KV CABLE XLPE FOR RAILWAY UNDER CROSSING ON TWO POLE STRUCTURE.

-

-

-

... More
33 kV,Single core 630 sq.mm Aluminium round wire Armoured XLPE cable (as per SBD specifications)

0.4

-

-

... More
33 kV, Single core 630 sq mm Cable termination kits (Raychem/Denson/3M)

8

-

-

... More
Steel Tubular Poles 13 Mtr Long (ST-410 Sp-69)

4

-

-

... More
G.I Channels X-arms including clamps, belts & Braces

650

-

-

... More
33 kV Polymer Pin Insulators ( 36 KV, 10 KN)

6

-

-

... More
33 kV Polymer composite Disc Insulators ( 36 KV, 70 KN)

8

-

-

... More
Earthing complete G.I Pipe(40mm) or G.I rod (2.5)mm along with G.I strip

4

-

-

... More
Guy set complete

4

-

-

... More
Alumunium Jointing Sleeves

4

-

-

... More
PG Clamps for 150 mmsq. ACSR Conductor

4

-

-

... More
Nuts and Bolts Galvanised

25

-

-

... More
Red Oxide

4

-

-

... More
Alumunium Paint

4

-

-

... More
Anti Climbing devices with clamps

4

-

-

... More
Cement Bottoming 1:2:4 MIX as PER REC Standards (0.7 cum per pole)

4

-

-

... More
POLE STRUCTURE, 33 kV ISOLATOR & 33 KV HT METERING CT PT OPERATED, AT BPCL SUB STATION

-

-

-

... More
13 Mtr. Long poles (ST-410 SP 69)

4

-

-

... More
33 KV Isolator without Earthing Blade(36 Kv,1250A,outdoor,3 poles,25kA with Dog ACSR clamps

1

-

-

... More
30 KV Lightening Arrestors (30 kV,10 kA,Station Class ,ZnO, Polymer) gap less

3

-

-

... More
33 Kv Post Insulator polymer 36kV Impulse ,Creepage distance 1224 m.

12

-

-

... More
33 kV, 3CX400 sq mm , Touch proof kit, screen separable elbow termination connector/kit, confirming to EN 50180/EN 50181 (Raychem/Denson/3M)

2

-

-

... More
G.I Steel of sorts (Channel 100x50x6 mm, Angle 65x65x6 mm & 50x50x6 mm, Flat 50x6 mm)

200

-

-

... More
33kV CT/PT Combined Unit, 3-phase, 50 Hz, ONAN cooled, outdoor type. The combined unit, CTs and PTs shall be as per below specifications. The CT ratio shall be as under: 1) 60/5 for 1.5 MVA, 33/11kV Transformer The rated burden of CT shall be 7VA, Accuracy Class 0.2s The PT shall be 33 kv/110 volts / √3, Three phase PT with rated burden 20VA per phase with proper colour coded identification. PTs shall be of uniform insulating and One minute power frequency dry withstand voltage 70KV

1

-

-

... More
Metering cubicle for 3phase 4 wire metering system suitable for 3 phase, HT, tri-vector meter with sealing and locking facility made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Provided with synthetic or semi synthetic gasket firmly glued to the surface, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangements. The panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening door. Including supply and fixing of 75mm GI pipe between CT/PT combined unit and metering cubicle for CT/PT wiring to tri-vector meter.

1

-

-

... More
MS Channels for mounting CT PT Combined Units with nuts and bolts (size 100 x 50 x 5 mm)

54

-

-

... More
3Ph4 Wire HT CT/PT operated Fully static Smart Tri-Vector Energy meters ( 0.2S 15min) DLMS Compliant Category 'C' with RS232 port . 33kV/√3 /110V/√3, Ph-N (3P, 4W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure or ABB)

1

-

-

... More
PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB).

1

-

-

... More
Copper Lugs preferably ring type duly crimped for termination of wires and tapes

1

-

-

... More
ACSR Jumpers with hardware fittings like ACSR to CT/PT unit bush clamp, other hardwares as per site requirement

1

-

-

... More
Providing standard C.I. Pipe Earth station, with 80 mm dia. 2000 mm long C.I. pipe spreading a homogeneous mixture of salt charcoal around the pipe etc, completely as per IS 3043, 1987 or latest revision.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.