Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Energy, Oil and Gas
Eprocure
Opening Date22 Nov 2024
Closing Date14 Dec 2024
Tender Amount₹ 2,75,44,000
Costs
EMD
₹ 5,51,000Document Cost
₹ 4,000Tender Fee
Refer Documents
Summary
Providing Of 33 Kv Power Supply
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDD_265581_1Tender No
STD-II/2024-25/BPCL/10Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) alongwith clamps for Panther conductor
1
-
-
33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) alongwith clamps for Panther conductor
1
-
-
33 kV Current transformer(33 kV,1 phase , 400-200/5-5-5 A, 5P, 0.2s, PS,outdoor)(1 No per phase)
3
-
-
30 kV Lightening Arrestors (30kV,10 KA,Station Class ,ZnO, Polymer, Discharge class 3) gap less
3
-
-
33 kV Voltage Transformer ( 33kV, 1- Phase, Multi Ratio , 0.5-3P , Outdoor) ( 1 No. per Phase)
3
-
-
33 kV Post Insulator polymer 36 kV Impulse ,Creepage distance 1224 m.
3
-
-
Galvanised Nuts &Bolts
0.15
-
-
Galvanised steel structure
3.5
-
-
12 Core 2.5 mm2 Control Cable copper Armoured,1.1 kV Grade,ISI, FRLS.
60
-
-
4 Core 2.5 mm2 Control Cable copper Armoured,1.1 kV Grade,ISI, FRLS.
300
-
-
2 Core 2.5 mm2 Control Cable copper Armoured,1.1 kV Grade,ISI, FRLS.
60
-
-
Lugs,Ferrules etc
1
-
-
T Clamps panther
15
-
-
Single tension fittings
30
-
-
Polymeric composite Disc Insulator 36 kV ,Lightening Impulse 170 kV positive and 180kV negative ,creepage distance 900 mm,min failing load 70kN
5
-
-
Earth wire7/4.00 mm sq
5
-
-
GI flat for earthing 50X6mm
6
-
-
Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height
68
-
-
33 kV Equipment Foundation & Gantry foundation (for additional equipments )
2
-
-
Earthing Mat (GI Flat 50x8)
1
-
-
Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip.
32
-
-
33 kV Yard Concreting/Metalling
1
-
-
Yard Lighting
1
-
-
33 kV Electrical safety gloves gloves (meet or exceed ASTM D120 and IEC EN60903 Standards)
3
-
-
11 kV Electrical safety gloves gloves (meet or exceed ASTM D120 and IEC EN60903 Standards)
3
-
-
Non-contact High Voltage Detector (Wrist Type) 1kV to 500KV , IP54 Protection Level
10
-
-
FRP Telescopic Earth/Discharge rod for 11 to 33 kV system (Assemble Length:-20 feet)
2
-
-
Electrical Insulating Rubber Matting IEC/BS EN 61111:2009
6
-
-
33 KV BPCL LINE FROM BAJALTA R/STN TO BPCL SUB STATION
-
-
-
13Mtr. Long POLE (ST-410 SP 69)
102
-
-
G.I Steel of sorts (Channel 100x50x6 mm, Angle 65x65x6 mm & 50x50x6 mm, Flat 50x6 mm)
6800
-
-
100 sqmm ACSR Conductor
15.45
-
-
PG clamps for 100 sqmm ACSR conductor
60
-
-
33 KV Polymeric composite Pin Insulator 36 KV,10 KN, Lighting Impulse 170 KV Positive and 180 KV Negative, creepage distance 900 mm
285
-
-
33 KV Polymeric composite Disc Insulator 36 KV,min failing load 70 KN, Lighting Impulse 170 KV Positive and 180 KV Negative, creepage distance 900 mm
60
-
-
Galvanized Nuts and Bolts
95
-
-
Danger Plates with Clamps
95
-
-
Anti -Climbing Device with Clamps
95
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
95
-
-
Red Oxide
95
-
-
Aluminium Paint
95
-
-
Cement bottoming 1:2:4 mix as per REC standards ( 0.6 cum/pole) alongwith Stone pad (300 mm X 300 mm X 75 mm)
95
-
-
Aluminium Jointing Sleeves
15
-
-
Galvanised Stay Set with 50x8 mm Stay clamp,guy insulator (2Nos.),anchor plate (300x300x8 mm),nut-bolts,2 Nos turn-buckles,1.8m long,20 mm diameter solid GS Stay rod & 7/4.00 mm dia GI Stranded wire complete
25
-
-
33 kV Isolator without earthing blade ( 36kV, 1250A) outdoor, 3-Pole, 25 kA
3
-
-
Guard Netting (with GI wire 8 SWG, GI Channel X-arm including clamps and braces, Eye Bolts)
25
-
-
Renewing the road surface ( damage caused during execution of work)
60
-
-
THICKENING OF 4.5 KM ACSR CONDUCTOR FROM 100 SQ.MM(DOG) TO 200 SQ. MM (PANTHER) FOR BPCL LINE FROM SIDHRA GRID STATION TO BAJALTA R/STN
-
-
-
11Mtr. Long POLE (ST-410 SP 56)
22
-
-
GI V cross arm with top bracket including clamp
950
-
-
GI Channel X-arm including clamps and braces
415
-
-
200 sqmm ACSR Conductor
14
-
-
PG clamps for 200 sqmm ACSR conductor
54
-
-
33 KV Polymeric composite Pin Insulator 36 KV,10 KN, Lighting Impulse 170 KV Positive and 180 KV Negative, creepage distance 900 mm
99
-
-
33 KV Polymeric composite Disc Insulator 36 KV,min failing load 70 KN, Lighting Impulse 170 KV Positive and 180 KV Negative, creepage distance 900 mm
54
-
-
Galvanized Nuts and Bolts
135
-
-
Danger Plates with Clamps
135
-
-
Anti -Climbing Device with Clamps
135
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
135
-
-
Red Oxide
135
-
-
Aluminium Paint
135
-
-
Cement bottoming 1:2:4 mix as per REC standards .6cum/pole
44
-
-
Aluminium Jointing Sleeves
13.5
-
-
Galvanised Stay Set with 50x8 mm Stay clamp,guy insulator (2Nos.),anchor plate (300x300x8 mm),nut-bolts,2 Nos turn-buckles,1.8m long,20 mm diameter solid GS Stay rod & 7/4.00 mm dia GI Stranded wire complete.
22.5
-
-
33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) alongwith clamps for Panther conductor
2
-
-
Guard Netting (with GI wire 8 SWG, GI Channel X-arm including clamps and braces, Eye Bolts)
24
-
-
33KV CABLE XLPE FOR RAILWAY UNDER CROSSING ON TWO POLE STRUCTURE.
-
-
-
33 kV,Single core 630 sq.mm Aluminium round wire Armoured XLPE cable (as per SBD specifications)
0.4
-
-
33 kV, Single core 630 sq mm Cable termination kits (Raychem/Denson/3M)
8
-
-
Steel Tubular Poles 13 Mtr Long (ST-410 Sp-69)
4
-
-
G.I Channels X-arms including clamps, belts & Braces
650
-
-
33 kV Polymer Pin Insulators ( 36 KV, 10 KN)
6
-
-
33 kV Polymer composite Disc Insulators ( 36 KV, 70 KN)
8
-
-
Earthing complete G.I Pipe(40mm) or G.I rod (2.5)mm along with G.I strip
4
-
-
Guy set complete
4
-
-
Alumunium Jointing Sleeves
4
-
-
PG Clamps for 150 mmsq. ACSR Conductor
4
-
-
Nuts and Bolts Galvanised
25
-
-
Red Oxide
4
-
-
Alumunium Paint
4
-
-
Anti Climbing devices with clamps
4
-
-
Cement Bottoming 1:2:4 MIX as PER REC Standards (0.7 cum per pole)
4
-
-
POLE STRUCTURE, 33 kV ISOLATOR & 33 KV HT METERING CT PT OPERATED, AT BPCL SUB STATION
-
-
-
13 Mtr. Long poles (ST-410 SP 69)
4
-
-
33 KV Isolator without Earthing Blade(36 Kv,1250A,outdoor,3 poles,25kA with Dog ACSR clamps
1
-
-
30 KV Lightening Arrestors (30 kV,10 kA,Station Class ,ZnO, Polymer) gap less
3
-
-
33 Kv Post Insulator polymer 36kV Impulse ,Creepage distance 1224 m.
12
-
-
33 kV, 3CX400 sq mm , Touch proof kit, screen separable elbow termination connector/kit, confirming to EN 50180/EN 50181 (Raychem/Denson/3M)
2
-
-
G.I Steel of sorts (Channel 100x50x6 mm, Angle 65x65x6 mm & 50x50x6 mm, Flat 50x6 mm)
200
-
-
33kV CT/PT Combined Unit, 3-phase, 50 Hz, ONAN cooled, outdoor type. The combined unit, CTs and PTs shall be as per below specifications.
The CT ratio shall be as under:
1) 60/5 for 1.5 MVA, 33/11kV Transformer
The rated burden of CT shall be 7VA, Accuracy Class 0.2s
The PT shall be 33 kv/110 volts / √3, Three phase PT with rated burden 20VA per phase with proper colour coded identification. PTs shall be of uniform insulating and One minute power frequency dry withstand voltage 70KV
1
-
-
Metering cubicle for 3phase 4 wire metering system suitable for 3 phase,
HT, tri-vector meter with sealing and locking facility made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Provided with synthetic or semi synthetic gasket firmly glued to the surface,
Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangements. The panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening door. Including supply and fixing of 75mm GI pipe between CT/PT combined unit and metering cubicle for CT/PT wiring to tri-vector meter.
1
-
-
MS Channels for mounting CT PT Combined Units with nuts and bolts (size 100 x 50 x 5 mm)
54
-
-
3Ph4 Wire HT CT/PT operated Fully static Smart Tri-Vector Energy meters ( 0.2S 15min) DLMS Compliant Category 'C' with RS232 port . 33kV/√3 /110V/√3, Ph-N (3P, 4W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh),
Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure or ABB)
1
-
-
PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB).
1
-
-
Copper Lugs preferably ring type duly crimped for termination of wires and tapes
1
-
-
ACSR Jumpers with hardware fittings like ACSR to CT/PT unit bush clamp,
other hardwares as per site requirement
1
-
-
Providing standard C.I. Pipe Earth station, with 80 mm dia. 2000 mm long C.I. pipe spreading a homogeneous mixture of salt charcoal around the pipe etc, completely as per IS 3043, 1987 or latest revision.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%