Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Eprocure
Opening Date14 Sep 2018
Closing Date2 Oct 2018
Tender Amount₹ 45,70,000
Costs
EMD
₹ 91,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_PDD_61674_1Bid Award Id
ViewTender No
EDB 69 of 2018-19Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete.
67
-
-
Supplying and erection of GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure.(Drawing enclosed)
61
-
-
Supplying and erection of GI 2200 mm long channel (75x40x6 mm) cross arms for H-frames,including back clamp/Collar clamp of 50x8 mm duly drilled with installtion of GI nuts & bolts,washers without making holes in the ST Pole as per REC standard.(Drawing enclosed)
6
-
-
Supplying and erection GI Angle 1700 mm long ( 50x50x6) cross braces for H-frames, including back clamp/Collar clamp of 50x8 mm duly drilled with installtion of GI nuts & bolts,washers without making holes in the ST Pole as per REC standard.(Drawing enclosed)
6
-
-
Supplying and erection GI Angle 2300 mm long ( 50x50x6) cross braces for H-frames, including back clamp/Collar clamp of 50x8 mm duly drilled with installtion of GI nuts & bolts,washers without making holes in the ST Pole as per REC standard.(Drawing enclosed)
6
-
-
Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN)
183
-
-
Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size.
18
-
-
Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard.
18
-
-
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection with
67
-
-
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
67
-
-
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 3.5 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose.
67
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of 30 mm2 ACSR ( Weasel) conductor including joints with PG clamps of required size (Note conductor to be provided by the Department)
10
-
-
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
67
-
-
Aluminium Jointing Sleeves
12
-
-
Guard Netting complete with earthing connection on both sides using Cradle guard wire 8 SWG GI wire and lashing of 10 SWG GI wire including GI x-arms with clamps and braces, threaded eye bolts, turn buckles and binding wire, nut bolts etc.,
6
-
-
Erection of 11/0.433 Distribution Transformer
-
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 63kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (Note: The transformer to be provided by JKPDD).
8
-
-
Supply and installation of LT bi-metalic connectors for making connection from DT bush rod to aluminium cables
32
-
-
Supply and fixing of LT Distribution Box for 63 KVA DTR with TPN MCCBs short ckt rating 16 KA for incomer 100 Amp and suitable MCCBs for outgoing circuits with terminal extensions.
8
-
-
Supply and installation of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN)
24
-
-
Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type
24
-
-
Supply and installation of 11 kV, G.O AB Switch , 3-phase, 200A
8
-
-
Supply and installation of 11 kV Horn, Gap Fuse 3-phase 100A
8
-
-
Supply and fixing of Un Armoured Single Core XPLE, 70 mm2 (2 Ckt) FRLS Cable
352
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site , and erection of 9 Mtr. Long ST Poles (ST-540, SP33) with pit excavation, refilling the pit with soil, boulders (Note: The poles shall be provided by JKPDD)
16
-
-
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole including muffing 20 cm above ground level, plaster and curing of concrete.
16
-
-
Supplying and erection of fabricated 9 feet long G.I channel X-arms of 100x50x6 mm including back clamp/Collar clamp of 50x8 mm duly drilled with installtion of GI nuts & bolts,washers without making holes in the ST Poles for installtion as per REC Standards. The Channels are to be bolted with 1.5 ft channel iron fitted with back to back with G.I nuts & Bolts for placement of transformer.
16
-
-
Supplying and erection of fabricated 9 feet long G.I channel X-arms of 75x40x6 mm including back clamp/Collar clamp of 50x8 mm duly drilled with installtion of GI nuts & bolts,washers without making holes in the ST Pole for installtion as per REC Standards.
64
-
-
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection with
16
-
-
Supplying and erection of fabricated 10 feet long G.I angle iron transformer belt of 50x50x6 mm including back clamp/Collar clamp of 50x8 mm duly drilled with installtion of GI nuts & bolts,washers without making holes in the ST Pole for installtion as per REC Standards.The angles are to be bolted with 1.5 ft angle iron with G.I nuts & Bolts for placement of transformer.
16
-
-
Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nutbolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard.
16
-
-
Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 for neutral earthing and 25X3 mm for 2 transformer body earth, 1 no. LA Earth and 1 no. GO handle earth. (Note: For LA Earth 1 pipe shall be kept separate)
40
-
-
Supplying and erection of 11kV Danger Plates with clamps with writing in English and Regional Language
8
-
-
Supply and painting 1 coat red oxide paint and 2 coats of al (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
16
-
-
Wedge Connectors/PG Clamps
48
-
-
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 3.5 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose.
16
-
-
Erection of LT Line
-
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site , and erection of 8 Mtr. Long ST Poles (540 SP15) with pit excavation, refilling the pit with soil, boulders (Note: The poles shall be provided by JKPDD)
230
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (540 SP 33) for road/line crossings, with pit excavation, refilling the pit with soil, boulders (Note: The poles shall be provided by JKPDD)
20
-
-
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole including muffing 20 cm above ground level plaster and curing of concrete.
250
-
-
Supply and fixing of clamps for LT Shackle insulators with GI back clamps to be fixed without drilling/punching of poles on ST poles including GI nuts & bolts,washers complete as per REC Standards.
1000
-
-
Supplying and fixing of Shackle Insulators (polymer) ( 16 KN)
1000
-
-
Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard.
20
-
-
Supplying and fixing of pole Earthing Complete by GI Spiral Earthing, 8 SWG 115 turn coil earthing as per REC J-1 drawing
250
-
-
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
250
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site ,Laying, stringing and binding of 50 mm2 ACSR ( Rabbit) conductor including joints with PG clamps of required size (Note conductor to be provided by the Department)
25
-
-
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
250
-
-
Aluminium Jointing Sleeves
20
-
-
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 3.5 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose.
250
-
-
Service Connection of Consumer Installation
-
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of Single Phase smart/pre-paid Energy Meter 5-30 Amp / 10-60 Amp, DLMS Compliant of accuracy class 1.0 in meter box with GI clamps on poles.(Note: The meters with meter box shall be provided by JKPDD)
279
-
-
Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 16 mm² Cable (2C) from LT Line to meter, 1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type
1395
-
-
Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 10 mm² Cable (2C) from meter to consumer cut out, 1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type
4185
-
-
T&P articles ( Wooden ladder,Safety Helmet,Pliers,Screw driver,Safety Gloves) as per the Specifications enclosed
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements